• Title/Summary/Keyword: Optimum operating condition

Search Result 299, Processing Time 0.024 seconds

A Study on the Welding Conditions of Weldability of Team Welding for Galvanized Steel Sheets of Automotive (자동차용 아연도금강판의 심 용접조건과 용접성에 관한 연구)

  • 임재규;정균호;국중하
    • Journal of Welding and Joining
    • /
    • v.19 no.1
    • /
    • pp.27-32
    • /
    • 2001
  • This paper is studied about welding conditions and weldability of seam welding for galvanized steel sheet of automotive. The fuel tank of automobile is made by seam welding to be required of airtight or oiltight. This method have required a short time for welding, simplicity operation progress and little HAZ. Especially, it has more less residual stress and transformation than different welding progress. So, this study is for decreasing the leakage occurrence rate and to make standard operating condition table anyone can operate easily. Therefore, this study is analyzed the optimum conditions of seam welding for making the automobile with galvanized steel sheets by means of observing the microstructure and configuration back projection, RT, tensile-shear strengths test and SEM. Optimum conditions of seam welding obtained as follows, current 17.2-17.6kA speed 1.0m/min weld time 4:10:6 and current 16.5-17.4kA, speed 0.83m/min, weld time 4:10:4 at t1.0, and current, 18.5-18.9kA, speed 0.8m/min, weld time 4:10:4 and current 16.5-17.4kA, speed 0.68m/mi, weld time 4:10:2 at t1.6.

  • PDF

Architectural and Interior Design of Chosun University Hospital Medical Center (조선대학교 병원 전문진료센타 설계)

  • Park, Young-Ho
    • Proceedings of the Korean Institute of Interior Design Conference
    • /
    • 2005.10a
    • /
    • pp.191-192
    • /
    • 2005
  • This project is to establish an annex clinic center under 5 floors with gross floor area of 3,000 Pyeong behind existing Chosun university Hospital main building with 600 beds. The goal of the design is connecting the new clinic center with the existing main building and completing a combined hospital that has synergy effects. Given the old condition of the hospital and characteristics of the ground, I tried to embody the image of Medical Pulse, which is very alive with strong pulse, and suggest vision of 21st century hospital. First, one main entrance as a combined hospital. For optimum access and functions, I used the entrance of existing building as the only main entrance of new combined hospital, rearrange the road in front of the main building and improve traffic system, and upgrade the image and function of combined main entrance by planning new atrium united robby that makes link to the main building easier. Second, section planning considering the optimum functions and convenience. I established 4 floors linking functionally with the existing building, minimized vertical traffic line, and enhanced convenience through barrier free environment, which is a horizontal traffic line without barriers, crucial to hospital. Third, combined zoning generating synergy effects. I linked sterilizing room with logistics center by operating room and service bridge, and arranged central treatment department horizontally, Also, by horizontally arranging cancer center and department of nuclear medicine close with PET and cyclotron center, I established identity of specialized departments.

  • PDF

Determination of Optimum Operational Parameters on Early Warning Device for Early Detection of Taste and Odor in Drinking Water Supplies (상수원수 내 이취미 조기감지를 위한 조기경보장치의 최적운전인자 도출)

  • Kim, Young-Il;Bae, Byung-Uk;Ju, Dae-Sung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.20 no.6
    • /
    • pp.849-855
    • /
    • 2006
  • Taste and odor (T&O) problems in drinking water supplies caused by eutrophication have become increasingly important because aesthetic qualities are the primary measures by which consumers estimate the quality of their drinking water. In order to overcome T&O problem, it is necessary to early detection method for T&O compounds before these compounds enter to water treatment plant. In this background, a early waming device for T&O compounds was developed and its performance tested under different operating condition. According to the experimental results on the adsorption efficiency of T&O compounds, when the raw water flowrate was 5 mL/min, the optimum stripping time and air flowrate were 5 hrs and 0.5 L/min, respectively. Comparison of activated carbon showed that foreign activated carbon was better than domestic activated carbon in terms of adsorption efficiency.

Reaction Characteristics of WGS Catalyst with Fraction of Catalyst in a Batch Type Fluidized Bed Reactor (회분식 유동층 반응기에서 촉매함량 변화에 따른 WGS 촉매의 반응특성)

  • Ryu, Ho-Jung;Hyun, Ju-Soo;Kim, Ha-Na;Hwang, Taek-Sung
    • Journal of Hydrogen and New Energy
    • /
    • v.22 no.4
    • /
    • pp.465-473
    • /
    • 2011
  • To find the optimum mixing ratio of WGS catalyst with $CO_2$ absorbent for SEWGS process, water gas shift reaction tests were carried out in a fluidized bed reactor using commercial WGS catalyst and sand (as a substitute for $CO_2$ absorbent). WGS catalyst content, gas velocity, and steam/CO ratio were considered as experimental variables. CO conversion increased as the catalyst content increased during water gas shift reaction. Variations of the CO conversion with the catalyst content were small at low gas velocity. However, those variations increased at higher gas velocity. Within experimental range of this study, the optimum operating condition(steam/CO ratio=3, gas velocity = 0.03 m/s, catalyst content=10 wt.%) to get high CO conversion and $CO_2$ capture efficiency was confirmed. Moreover, long time water gas shift reaction tests up to 20 hours were carried out for two cases (catalyst content = 10 and 20 wt.%) and we could conclude that the WGS reactivity at those conditions was maintained up to 20 hours.

Optimization of operating parameters to remove and recover crude oil from contaminated soil using subcritical water extraction process

  • Taki, Golam;Islam, Mohammad Nazrul;Park, Seong-Jae;Park, Jeong-Hun
    • Environmental Engineering Research
    • /
    • v.23 no.2
    • /
    • pp.175-180
    • /
    • 2018
  • Box-Behnken Design (BBD) under response surface methodology (RSM) was implemented to optimization the operating parameters and assess the removal and recovery efficiencies of crude oil from contaminated soil using subcritical water extraction. The effects of temperature, extraction time and water flow rate were explored, and the results indicate that temperature has a great impact on crude oil removal and recovery. The correlation coefficients for oil removal ($R^2=0.74$) and recovery ($R^2=0.98$) suggest that the proposed quadratic model is useful. When setting the target removal and recovery (>99%), BBD-RSM determined the optimum condition to be a temperature of $250^{\circ}C$, extraction time of 120 min, and water flow rate of 1 mL/min. An experiment was carried out to confirm the results, with removal and recovery efficiencies of 99.69% and 87.33%, respectively. This result indicates that BBD is a suitable method to optimize the process variables for crude oil removal and recovery from contaminated soil.

The Study on denitrification of low organic loading sewage by pre-denitrification process (유기물부하가 낮은 하수의 전달탈질공법에 의한 탈질방안)

  • Lee, Cheol Seung;Seo, Jong Hwan;Kim, Jin U
    • Journal of Environmental Science International
    • /
    • v.13 no.9
    • /
    • pp.779-878
    • /
    • 2004
  • This study was conducted to analyze the operating conditions of predenitrification process to improve the treatment efficiency in low organic loading sewage plant in use today, and to investigate the treatment efficiency of pilot plant added night soil as well as the nitrogen removal characteristics of pilot plant added carbon sources. In the operation under the condition of $BOD_{5}$ sludge load 0.03-0.28kg $BOD_{5}$/kg VSS/d and oxic ammoniac nitrogen sludge load 0.02-0.24 $kgNH_{4}^{+}$-N/kg MLVSS/d, nitrification efficiency is higher than 95%. In order to achieve 70% nitrogen removal at the T-N sludge loading 0.06kg T-N/kg VSSㆍd and the SRT 6~11 days, optimum operating factors were revealed to $CODc_{r}$/T-N ratio 9, recycle ratio 2.6, and denitrification volume ratio 0.33. At this time, denitrification capacity was approximately 0.09 kg $NO_{3}^{-}$-N/kg $CODc_{r}$; specific nitrification rate was 3.4mg $NH_{4}^{+}$-N/g MLVSS/hr; and specific denitrification rate was 4.8mg $NO_{3}^{-}$-N/g MLVSS/hr.

Performance Prediction of Heat Exchanger for Waste Heat Recovery from Humid Flue Gases (습증기를 포함한 연소가스의 폐열회수를 위한 열교환기 성능 예측)

  • Jeong, Dong-Woon;Lee, Sang-Yong;Lee, Han-Ju
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.276-281
    • /
    • 2000
  • A simulation program using the mass transfer correlation was constructed to analyze 1-D simplified condensing flow across the tube bank. Higher efficiency was anticipated by reducing the flue gas temperature down below the dew point where the water vapor in the flue gas is condensed at the surface of the heat exchanger; that is, the heat transfer by the latent heat is added to that by the sensible heat. Thus, there can be an optimum operating condition to maximize the heat recovery from the flue gas. The temperature rises of the flue gas and the cooling water between the inlet and the outlet of the tube bank were compared with the experimental data reported previously. The predicted results agree well with the experimental data. Using this simulation program, the parametric studies have been conducted fur various operating conditions, such as the velocities and temperatures of the vapor/gas mixture and the cooling water, the number of the rows, and the conductivity of the wall material.

  • PDF

Effects of Particle Concentrations on Friction Factors and Pressure Drops in a Horizontal Pipe (수평 관에서 고체입자 농도가 압력강하 및 마찰계수에 미치는 효과)

  • Ahn, S.W.;Lee, B.C.;Kang, H.K.
    • Journal of Power System Engineering
    • /
    • v.11 no.4
    • /
    • pp.44-49
    • /
    • 2007
  • Generally, the economic concept of optimized design and operating conditions in fluidized bed heat exchangers can hardly be realized. Because the lack of fundamental knowledge about the particle flows, the optimum design of the fluidized bed heat exchanger is rather limited. In the present work, measurements are made on pressure drops and friction factors in the horizontal circular tube with solid particles in the circulating water. Two different solid particles of diameters of 3mm and 4mm are covered. The Reynolds numbers are ranged from 10,000 to 45,000. It is concluded that the friction factors for the particles of 4mm diameter are much higher than those for the particles of 3mm diameter. And at the lower particle concentration, the friction factors are strongly influenced by the fluid velocity rather than the particle concentration; However, the effect of the particle concentration on friction factors is also significantly higher at a higher particle concentration operating condition.

  • PDF

4:2:1 compromise plans using Min-Max method (Min-Max 방법을 적용한 4:2:1 절충적 계획)

  • 최재혁;강창욱
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.21 no.47
    • /
    • pp.1-10
    • /
    • 1998
  • Testing high reliability devices under nomal operating condition is difficult, because the devices are not likely to fail in the relatively short time available for tests. For most applications it is necessary to accelerate the causes of failure by increasing a stress above its nomal value. Previous accelerated life test(ALT) plans have shown how to find optimum allocation, lowest stress and sample size subject to minimizing the variance of mean life estimator. In these ALT plans, the highest acceptable test-stress was assumed to be specified in advance by the experimenter but there is no guidance for selecting it. This assumption is, however, inappropriate for many applications. Testing devices at too-high stress levels can invalidate the extrapolation model, or introduce failure mechanisms that are not anticipated under nomal operating conditions. In this paper, we propose new 4:2:1 compromise plans using Min-Max method to minimize this risk and present minimized test-stress levels(max, middle, min), and find sample allocation based on Min-Max 4:2:1 compromise plans. In result, we compare previous 4:2:1 compromise plans specified maximum test-stress with Min-Max 4:2:1 compromise plans minimized maximum test-stress.

  • PDF

The Effect of Exhaust Gas Recirculation (EGR) on Combustion Stability, Engine Performance and Exhaust Emissions In a Gasoline Engine

  • Jinyoung Cha;Junhong Kwon;Youngjin Cho;Park, Simsoo
    • Journal of Mechanical Science and Technology
    • /
    • v.15 no.10
    • /
    • pp.1442-1450
    • /
    • 2001
  • The EGR system has been widely used to reduce nitrogen oxides (NO$\_$x/) emission, to improve fuel economy and suppress knock by using the characteristics of charge dilution. However, as the EGR rate at a given engine operating condition increases, the combustion instability increases. The combustion instability increases cyclic variations resulting in the deterioration of engine performance and emissions. Therefore, the optimum EGR rate should be carefully determined in order to obtain the better engine performance and emissions. An experimental study has been performed to investigate the effects of EGR on combustion stability, engine performance,70x and the other exhaust emissions from 1.5 liter gasoline engine. Operating conditions are selected from the test result of the high speed and high acceleration region of SFTP mode which generates more NO$\_$x/ and needs higher engine speed compared to FTP-75 (Federal Test Procedure) mode. Engine power, fuel consumption and exhaust emissions are measured with various EGR rate. Combustion stability is analyzed by examining the variation of indicated mean effective pressure (COV$\_$imep/) and the timings of maximum pressure (P$\_$max/) location using pressure sensor. Engine performance is analyzed by investigating engine power and maximum cylinder pressure and brake specific fuel consumption (BSFC)

  • PDF