• Title/Summary/Keyword: Optimum installation height

Search Result 14, Processing Time 0.032 seconds

Optimum Locations of Passe Conductor Loops for Magnetic Field Mitigation of Transmission Line using GA (유전 알고리듬을 이용한 송전선로 자계 저감용 도체루프의 최적 위치 선정)

  • Shin Myong-Chul;Kim Jong-Hyung
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.54 no.5
    • /
    • pp.234-241
    • /
    • 2005
  • The performance of passive conductor loop (hereinafter 'loop') method which is used to mitigate the magnetic field around overhead power transmission line is dependent on its configuration and installed location, which are affected by installation conditions of the loops such as objective areas and levels of magnetic field mitigation. Thus, because the design problem of loops is difficult and cumbersome by variety of their configuration and complexity of magnetic coupling mechanism, it is need to be formulated as a computer-based optimum problem to determine the most effective and reasonable loop model satisfying the installation conditions. In this paper, the optimum locations of the multi-wired multiple loops including series reactance compensations are searched by using the genetic algorithm (GA) to mitigate effectively the magnetic fields of relatively near points or far points from transmission line at Am height, and the magnetic fields mitigation characteristics of each loop are analyzed in the view of magnitude, direction and phase of cancellation fields by polarized vector concept to identify their adequacy and rationality for the installation objectives.

Optimum Wattage and Installation Height of Nano-Carbon Fiber Infrared Heating Lamp for Heating Energy Saving in Plug Seedling Production Greenhouse in Winter Season (동절기 공정육묘장의 난방 에너지 절감을 위한 나노탄소섬유적외선 난방등의 적정 전력과 설치 높이)

  • Kim, Hye Min;Kim, Young Jin;Hwang, Seung Jae
    • Journal of Bio-Environment Control
    • /
    • v.25 no.4
    • /
    • pp.302-307
    • /
    • 2016
  • The aim of this study was to examine the optimum wattage and installation height using nano-carbon fiber infrared heating lamp (NCFIHL) for heating energy saving and plug seedling production in plug seedling production greenhouse in winter season. NCFIHL of 700 and 900 W was installed over the bed ($1.2{\times}2.4m$) as 0.7, 1.0, and 1.3 m height, respectively, for the production of grafted watermelon seedling in venlo-type glasshouse. Watermelon (Citrullus lanatus (Thunb.) Manst.) 'Jijonggul' and gourd (Lagenaria leucantha Rusby.) 'Sunbongjang' were used as scions and rootstocks, respectively. The scions and rootstocks were grafted by single cotyledon ordinary splice grafting. Light intensity of NCFIHL was below the $1{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$ in all treatment. Spectral distributions of NCFIHL presented mostly infrared area. When outside air temperature was below $10^{\circ}C$, 700 and 900 W NCFIHL installed with 0.7 m height treatment and 900 W NCFIHL installed with 1.0 m height treatment maintained the setting air temperature ($20^{\circ}C$) at night. In the result of taking thermal imaging, the grafted watermelons were getting warm fast in 900 W NCFIHL installed with 0.7 m height treatment at night. Compactness of the grafted watermelons was the greatest in 700 W NCFIHL installed with 1.3 m height treatment. The results indicate that NCFIHL installed above 1.0 m height using 700 W was suitable for production of plug seedling.

Differential temperature fire detector analysis of comparative study based on sensor installation (차동식 열감지기 설치기준 비교분석에 관한 연구)

  • Hwang, Dong-Hwan;Yang, Kwang Mo;Kang, Kyung-Sik
    • Journal of the Korea Safety Management & Science
    • /
    • v.16 no.4
    • /
    • pp.379-389
    • /
    • 2014
  • Fire detectors are designed to minimize loss of life from a fire alarm system as an alarm to help evacuate more quickly until the completion of the evacuation alarm should be continued. the purpose of such alarms in order to achieve the characteristic fire heat release rate reaches a certain level, or when a certain time has elapsed, when the heat detector is to be alarms to answer. Requires a quick response, it is desirable to install the sensor as much as possible, but taking into account the cost of installation problems by engineering approach to minimize the quantity and rapidity of detection capability should be increased. In order to increase the rapidity of fire detectors in a room according to the height of the sensing period is to be maintained the optimum distance of the fire detector detects characteristics should be considered. Differential spot-type heat detectors installed domestic basis, depending on the type of sensor that can detect one sensor area is limited and less than 4m ceiling height regulations and simply double the number in excess of 4m and intended to be installed.

Optimal height of installing sticky traps for monitoring fungus gnats (버섯파리류 예찰을 위한 끈끈이트랩의 최적 설치위치)

  • Yoon, Jung-Beom;Kim, Hyeong-Hwan;Kim, Dong-Hwan;Yang, Chang-Yeol;Seo, Mi-Hey
    • Journal of Mushroom
    • /
    • v.16 no.1
    • /
    • pp.57-60
    • /
    • 2018
  • Agricultural sticky traps are used for forecasting flying insects, including fungus gnat adults. Forecasting using sticky trap is an important measure to determine pesticides or environmentally friendly control means. Sticky traps of various colors can be installed easily and quickly. The yellow sticky trap is most effective for forecasting fungus gnat adults. In addition, they are used for control purposes by mass trapping. We tested the optimum installation height of yellow sticky traps to forecast and control the fungus gnat adults effectively in the cultivation of mushroom and horticultural plants. The number of captured fungus gnat adults was highest on the second floor for button mushroom and oyster mushroom, 100 cm above the floor for sawdust shiitake mushroom, 20 cm under the floor for hydroponic strawberry, and 20 cm above the floor for hydroponic tomato. This suggests that sticky trap height should be installed differently depending on the cultivation type or environment for effective forecasting and control of fungus gnat adults.

A Study of the Roundabout Hump type Crosswalks Installation Criteria That Takes Into Account the Safety of Pedestrian Traffic (보행자 통행안전성을 고려한 회전교차로의 고원식횡단보도 설치기준 연구)

  • Lim, Chang-Sik;Choi, Yang-Won
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.36 no.6
    • /
    • pp.1075-1082
    • /
    • 2016
  • In order to calculate the optimum installation interval between a speed hump and hump type crosswalk that are installed continuously in succession, this study examined the speed of a vehicle that passes different intervals between speed humps and hump type crosswalks from the approach section of a roundabout having a maximum speed limit of 30km/h; analyzed the effects of speed humps and hump type crosswalks installed continuously in succession on vehicle driving speed; and simulated the optimum installation height of hump type crosswalk. As a result, the following conclusion was drawn. First, it was found that the optimum interval between a speed hump and hump type crosswalk, which are the representative traffic calming techniques for reducing vehicle speed, to control vehicle speed under 30km/h is 30m. Second, as a result of comparing the deceleration of a vehicle that pass hump type crosswalks, it was found that if the installation interval is 65 m and above, a speed hump and hump type crosswalk had no effect. Therefore, it is desirable that the maximum installation interval between a speed hump and hump type crosswalk for controlling vehicle speed within a fixed road section should not exceed 65m. Third, the analysis showed that the optimum installation height of hump type crosswalk is 6-8cm in case vehicle speed at the approach section is 20km/h or lower, 8-10cm in case of 30km/h, and 10cm in case of 30km/h or higher, respectively. Fourth, even at a road section on which a speed hump and hump type crosswalk are installed, speed reduction effects may sometimes be insignificant due to a driver's studying effect, traffic conditions and so on. Thus, it is judged that speed reduction effects will be greater if several traffic calming techniques such as speed hump, chicane, and choker are applied at the same time. Therefore, in case of applying traffic calming techniques for the purpose of reducing vehicle speed in order to promote pedestrian safety, the composite application of several techniques should be considered.

Design of a Vertical Lathe for the Improved Stability at High Speed Machining (고속가공의 안정성 향상을 위한 수직선반의 설계)

  • Ro, Seung-Hoon;Shon, Jae-Yul;Ro, Kyung-Ho;Kim, Sung-Chul
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.27 no.10
    • /
    • pp.1728-1737
    • /
    • 2003
  • The vertical lathe is a very popular machine tool in modem manufacturing industries because of its small area of installation. The small installation area is highly desirable for the flexibility improvement of the manufacturing systems such as FMS, CIM, and IMS. The vertical lathe, however, has much taller height compared to the traditional horizontal lathe, and consequently more severe vibrations. In this study, the structure of a vertical lathe is analyzed to investigate the dynamic properties and further to establish some ideas of the design alteration for the improved dynamic stability even at the higher operating speed. The simulation model is implemented to apply those design alterations for the optimization. The result of this study is not only prosperous but also ready to be applied to the optimum design of various machine tool structures for the improved stability.

Simulation of Pipe Network for Optimum Heat Supply in the Hot Water Heating System of Apartment House (공동주택 온수난방 시스템의 적정 열공급을 위한 배관망 시뮬레이션)

  • Kim, J.Y.;Mim, M.K.;Choi, Y.D.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.5 no.3
    • /
    • pp.157-168
    • /
    • 1993
  • Pipe network of hot water heat supply system in an apartment house was analyzed. Flowrate and supply heat capacity of each household in which constant flowrate balancing valve is installed in a single zone system were calculated and the results were investigated. In the existing piping system, the non-uniformity of heat supply with floors due to the static pressure and temperature difference between supply main and return main can not be avoided and this tendency get intense with the increase of the height of building. The non-uniformity of heat supply can be prevented by the installation of balancing valve at each household, however if the performance of supply pump is not sufficient to overcome the energy loss due to the installation of balancing valve for constant flow rate or if the selection of the valve capacity is not adequate, the valves will may lose their controllability.

  • PDF

Effect of different plant densities on growth and yield of sorghum(Sorghum bicolor L. Moench.)

  • Cho, Young Dae;Jung, Ki Yuol;Chun, Hyun Chung;Lee, Sang Hun;Kang, Hang Won
    • Proceedings of the Korean Society of Crop Science Conference
    • /
    • 2017.06a
    • /
    • pp.206-206
    • /
    • 2017
  • Sorghum is a crop with a various plant height depending on the planting density. If the height exceeds 1.8m, which is the harvestable height of the combine, loss is caused by clogging of the installation, entrance of the threshing section and the threshing section. The purpose of this study is to set the planting distance and number of plants per hill suitable for combine harvesting as the plant length does not exceed 1.8m. The experimental variety was Nampungchal. The experiment design was a split-plot design with three replications. The treatments were as follow: Main-plot were 1 and 2 plants as number of plants per hill and sub-plots were $60{\times}20cm$ (practice), $70{\times}15$, 20, 25, 30 cm as planting distance. The amount of nitrogen, phosphate and potassium fertilization were 100, 70, $80kg\;ha^{-1}$. Data were collected: (1) grain yield: weight of grain in $kg\;ha^{-1}$, (2) 1000 grain weight: average weight of 1000 grain, (3) plant height: distance from soil to top of panicle, (4) ear length: distance from top of stem to top of ear in cm, (5) stem diameter: diameter of second internode, (6) tiller number per hill. Analyses of variance were performed using R version 3.3.1(https://www. r- project. org). The Duncan's multiple range test(DMR) was used to separate treatment means at P < 0.05. As number of plants per hill increased, plant height and yield increased and tiller number decreased. As planting distance increased, plant height and yield decreased and tiller number increased. At 1 plant per hill, the plant height did not exceed 1.8m at all planting distance. At 2 plants per hill, the plant height did not exceed 1.8m from the planting distance of $70{\times}25cm$. At 1 plant per hill, the tiller number increased to 0.23, 0.27, 0.60 and 0.70 as the planting distance increased to $70{\times}15$, 20, 25 and 30 cm, respectively. At 2 plants per hill, the tiller number increased to 0.03, 0.03, 0.14 and 0.40 as the planting distance increased to $70{\times}15$, 20, 25 and 30 cm, respectively. At 1 plant per hill, the yield decreased to 6030, 4280, 3400 and $3230kg\;ha^{-1}$ as the planting distance increased. At 2 plant per hill, the yield decreased to 7850, 5770, 5720 and $4960kg\;ha^{-1}$ as the planting distance increased. We recommend that the optimum number of plants per hill and planting distance is 2 and $70{\times}25cm$ suitable for combine harvesting.

  • PDF

A study on the determination of shear strength and the support design of pre-failed rock slope (일차파괴된 암반사면의 전단강도 및 보강설계법 고찰)

  • 조태진;김영호
    • Tunnel and Underground Space
    • /
    • v.5 no.2
    • /
    • pp.104-113
    • /
    • 1995
  • Shear strength of the discontinuity on which the pre-failure of rock slope was occurred during surface excavation was measured through the direct shear test using core samples obtained in-situ. Internal friction angle was increased as the roughness of discontinuity surface(JRC) was increased. Results of the tilt test using core samples of higher JRC also showed very similar trend as those of the direct shear test. When the samples replicated from natural cores were used int he tilt test, results of friction angles showed almost perfect continuation of the residual friction angles from the direct shear test. However, when the gouge material existed in the discontinuity the internal friction angle strongly depended upon the rate of filling thickness to the height of asperity irrespective of the JRC. Based on the results of both direct shear test and tilt test internal friction angle and cohesion of discontinuity, which reflect the in-situ conditions fo pre-sliding failure and also can be used for the optimum design of support system, were assessed. Two kinds of support measures which were expected to increase the stability of rock slope were considered; lowering of slope face angle and installation of rock cable. But, it was found that the first method might lead to more unstable conditions of rock slope when the cohesion of discontinuity plane was negligibly low and in that case the support systems of any kind which could exert actual resisting force were needed to ensure the permanent stability of rock slope.

  • PDF

Model Test Study on the Reinforcing Effect of Inclined System Bolting (경사볼트의 보강효과에 대한 모형시험 연구)

  • Lee, Jea-Dug;Kim, Byoung-Il;Piao, Ming-Shan;Yoo, Wan-Kyu
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.32 no.5C
    • /
    • pp.231-238
    • /
    • 2012
  • The rockbolt functions as a main support, which restricts enlargement of the plasticity area and increases stability in the original ground around tunnels, and prevents a second deformation of an excavated surface by supplementing vulnerability arising from opening of the excavated surface. System bolting is generally applied if ground conditions are bad. System bolting is generally installed perpendicular to the excavation direction in every span. If a place is narrow, or it is difficult to insert bolts due to construction conditions, it may be connected and used with short bolts, or installed obliquely. In this study, laboratory model tests were performed to analyze the effect of the ground being reinforced by inclined bolts, based on a bending theory that assumes that the reinforced ground is a simple beam. In all test cases, deflections and vertical earth pressures induced by overburden soil pressure were measured. Total of 99 model tests were carried out, by changing the installation angle of bolts, lateral and longitudinal distance of bolts, and soil height. The model test results indicated that when the installation angle of bolts was less than $75^{\circ}$, deflections of model beams tended to increase rapidly. Also, the relaxed load that was calculated by earth pressure was rapidly increased when the installation angle of bolts was less than $75^{\circ}$. However, the optimum installation angle of inclined bolts was judged to be in the range of $90^{\circ}{\sim}75^{\circ}$. Also, as might be expected, the reinforcement effect of bolts was increased when the longitudinal and lateral distance of bolts was decreased.