Method of Optimum Efficiency to Coefficient of Utilization for Single Phase Induction Motor (단상 유도전동기의 이용률 변동에 대한 최적효율 산정기법)

  • Kim, Yang-Ho;Kim, Young-Sun
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.55 no.4
    • /
    • pp.155-160
    • /
    • 2006
  • In this paper, deduced suitable optimization to request output condition after taking closely characteristic data of single phase induction motor(SIM) which is the possibility becoming economic is coming to be demanded. Motor proper move connection data took advantage of result of existing data and iron loss and copper loss, mechanical loss took advantage of statistical data, and decide motor move laking advantage of saving data and secondary resistance and optimum purpose of method that is proposed through single phase induction motor and comparison performance evaluation having on the same output parameter. That decide material factor, electric power damage ratio, and coefficient of utilization for optimum function by method that search request output and optimum values of efficiency case by case and decided is proper that is saved after take magnetizing reactance relationship. This research result which it sees against a material expense with use coefficient of utilization which is included in loss expense decides the same plan variable back the place efficiency is useful and will be applied.

Optimum Design Condition of the Collins Cryocooler (Collins 내동기의 최적 설계조건)

  • Lee, S.W.;Kim, S.Y.;Jung, P.S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.4 no.3
    • /
    • pp.183-190
    • /
    • 1992
  • The Collins cryocooler is numerically analysed with the optimization technique, and the optimum operating and design conditions are searched. This paper shows that liquefied helium quantity has an external maximum w.r.t. the total mass flow rate, the mass flow rates through expander and the capacities of heat exchangers. The liquefied helium quantity increases as the compressor exit pressure of the cryocooler does. The maximum quantity of liquefied helium and the maximum coefficient of performance have been found to exist in extremum, depending on the ratios of each heat exchanger capicities to the total one. At the optimum condition, the capacity of heat exchanger in high temperature region is larger than that in low temperature region.

  • PDF

Study on Two-Coil and Four-Coil Wireless Power Transfer Systems Using Z-Parameter Approach

  • Seo, Dong-Wook;Lee, Jae-Ho;Lee, Hyung Soo
    • ETRI Journal
    • /
    • v.38 no.3
    • /
    • pp.568-578
    • /
    • 2016
  • A wireless power transfer (WPT) system is usually classified as being of either a two-coil or four-coil type. It is known that two-coil WPT systems are suitable for short-range transmissions, whereas four-coil WPT systems are suitable for mid-range transmissions. However, this paper reveals that the two aforementioned types of WPT system are alike in terms of their performance and characteristics, differing only when it comes to their matching-network configurations. In this paper, we first find the optimum load and source conditions using Z-parameters. Then, we estimate the maximum power transfer efficiency under the optimum load and source conditions, and we describe how to configure the matching networks pertaining to both types of WPT system for the given optimum load and source conditions. The two types of WPT system show the same performance with respect to the coupling coefficient and load impedance. Further, they also demonstrate an identical performance in the two cases considered in this paper, that is, a strong-coupled case and a weak-coupled case.

Effects of Nafion Contents on the Performance of MEAs Prepared by Decal-Transfer Method (Nafion 함량이 데칼전사기법을 통해 제작된 고분자 전해질 연료전지의 MEA 성능에 미치는 영향)

  • Kim, Gyeong-Hee;Cho, Eun-Ae;Han, Jong-Hee;Kim, Sung-Hyun;Eom, Kwang-Sup
    • Journal of Hydrogen and New Energy
    • /
    • v.23 no.2
    • /
    • pp.125-133
    • /
    • 2012
  • Nafion ionomer located in electrode helps to increase the platinum utilization and proton conductivity. To achieve higher performance in PEMFCs, it is important an optimum Nafion content in the electrode. As the platinum loading and fabricated method depend on the optimum Nafion content. In this study, we have examined the interrelationship between platinum loading and Nafion content fabricated by decal transfer method. For electrodes with 0.25 and 0.4 mg/$cm^2$ Pt loading, best performance was obtained at 25 wt.% Nafion ionomer loading. It is also found that MEA with 0.25 mg/$cm^2$ Pt, the optimum Nafion content appears differently at low and high current density.

A Study on the Fabrication and Performance Evaluation of Worm Gear Reducer (웜기어 감속기 제작 및 성능평가에 관한 연구)

  • Lee, Dong Gyu;Zhen, Qin;Jeon, Min Hyong;Kim, Lae Sung;Lyu, Sung-Ki
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.17 no.1
    • /
    • pp.1-7
    • /
    • 2018
  • We aimed to develop a high quality 3.5 ton class swing reducer by studying the efficiency improvement of the reducer through the optimum design and performance evaluation of the assembled, high efficiency, lightweight 3.5 ton swing reducer. Based on the optimal design of the worm and worm wheel, the optimal manufacturing method of the worm wheel, the optimized casing design, and the optimum design of the output pinion, Respectively. Therefore, in this paper, to improve the efficiency of the worm gear reducer system, we will develop the manufacturing technology and verify the mass production by combining the manufacturing process design, processing and assembling technology according to the optimization design. We have conducted research to realize mass production by product verification such as product efficiency, reliability and durability according to optimal design of worm gear reducer.

Near-Optimum Blind Decision Feedback Equalization for ATSC Digital Television Receivers

  • Kim, Hyoung-Nam;Park, Sung-Ik;Kim, Seung-Won;Kim, Jae-Moung
    • ETRI Journal
    • /
    • v.26 no.2
    • /
    • pp.101-111
    • /
    • 2004
  • This paper presents a near-optimum blind decision feedback equalizer (DFE) for the receivers of Advanced Television Systems Committee (ATSC) digital television. By adopting a modified trellis decoder (MTD) with a trace- back depth of 1 for the decision device in the DFE, we obtain a hardware-efficient, blind DFE approaching the performance of an optimum DFE which has no error propagation. In the MTD, the absolute distance is used rather than the squared Euclidean distance for the computation of the branch metrics. This results in a reduction of the computational complexity over the original trellis decoding scheme. Compared to the conventional slicer, the MTD shows an outstanding performance improvement in decision error probability and is comparable to the original trellis decoder using the Euclidean distance. Reducing error propagation by use of the MTD in the DFE leads to the improvement of convergence performance in terms of convergence speed and residual error. Simulation results show that the proposed blind DFE performs much better than the blind DFE with the slicer, and the difference is prominent at the trellis decoder following the blind DFE.

  • PDF

Optimum Collector Area and Economic Evaluation for the Greenhouse Heating (태양열 온실 난방에 대한 최척 집열 면적과 경제성 평가)

  • Pak, Ee-Tong;Kim, Kyu-In
    • Solar Energy
    • /
    • v.2 no.1
    • /
    • pp.49-58
    • /
    • 1982
  • Aim of this study was to obtain the heating performance and the economic evaluation on solar heating system for greenhouse which area of floor was $90m^2$. For heating performance effective solar energy for the greenhouse was compared with overall heating loads including coefficient of heat transfer and conduction. And the economic evaluation solar heating system was evaluated by comparison its initial investiment costing with oil saving cost. Initial investiment costing included collector cost, storage cost, piping cost, control system cost and miscellaneous costs which included pumps, motors etc. The contents of this study included the survey of climate conditions for solar heating, long-term collector performance and optimum collector area of solar heating system in existing greenhouse. The results are follows: 1. Average horizontal radiation during winter was $2,434Kcal/m^2$ day which was the highest value in this country, so the climate conditions of Suwon was suitable for solar heating. 2. Resulting calculation of the optimum collector area was $30m^2$ and the solar energy accounted for 30% of the overall heating load. 3. The capacity of storage tank required 60 liter per unit area ($m^2$) of solar collector.

  • PDF

Optimum MPPT Control Period for Actual Insolation Condition (실제 일사량 조건에서의 최적 MPPT 제어주기)

  • Ryu, Danbi;Kim, Yong-Jung;Kim, Hyosung
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.24 no.2
    • /
    • pp.99-104
    • /
    • 2019
  • Solar power generation systems require maximum power point tracking (MPPT) control to acquire maximum power using inefficient and high-cost PV modules. Most conventional MPPT algorithms are based on the slope-tracking concept. The perturb and observe (P&O) algorithm is a typical slope-tracking method. The two factors that determine the MPPT performance of P&O algorithm are the MPPT control period and the magnitude of the perturbation voltage. The MPPT controller quickly moves to the new maximum power point at insolation change when the perturbation voltage is set to large, and the error of output power will be huge in the steady state even when insolation is not changing. The dynamics of the MPPT controller can be accelerated even though the perturbation voltage is set to small when the MPPT control period is set to short. However, too short MPPT control period does not improve MPPT performance but consumes the MPPT controller resources. Therefore, analyzing the performance of the MPPT controller is necessary for actual insolation conditions in real weather environment to determine the optimum MPPT control period and the magnitude of the perturbation voltage. This study proposes an optimum MPPT control period that maximizes MPPT efficiency by measuring and analyzing actual insolation profiles in typical clear and cloudy weather in central Korea.

A Study on Super Resolution Optimum Beam Steering Pattern for Improvement Moving Target Estimation Accuracy (이동 목표물 추정 정확도를 향상시키기 위한 고 분해능 최적 빔 지향 패턴에 관한 연구)

  • Cho, Sung Kuk;Jeon, Byung Kook;Yang, Gill Mo
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.10 no.4
    • /
    • pp.71-78
    • /
    • 2014
  • Method a target estimation in spatial are mobile wireless communication using network cell and GPS. It have much error that mobile wireless communication depend on cell size. GPS method can't find a target in shadow and inner area. In this paper, we estimate a target as direction of arrival method using adaptive array antenna system. Adaptive array antenna system can obtain desired signal to remove other signal This paper studied digital beamforming method in order to estimation a target. Proposed method is modified optimum weight and antenna error correction to estimation an optimal receive signal. Digital beamforming method decided a signal phase and amplitude from received signal on array antenna element. But if it is not to do error correction of received signal, system performance have decreased. Firstly, we proposed modified optimum weight in order to finding desired target. Secondly, we are error correction of antenna incident signals by optimal weight before digital beamforming method. Thirdly, throughly simulation, we showed that system performance of proposed method compare proposal method with general method. It have improved resolution of estimation target to good performance more proposed method than general method.

Evaluation of Warm-Recycled Asphalt Mixtures using Polyethylene Wax-Based Additive (중온화 첨가제를 사용한 중온 재생 아스팔트 혼합물 평가)

  • Lee, Jin Wook;Lee, Moon Sup;Kim, Yong Joo;Cho, Dong Woo;Kwon, Soo Ahn
    • International Journal of Highway Engineering
    • /
    • v.15 no.4
    • /
    • pp.43-51
    • /
    • 2013
  • PURPOSES : The main purposes of this study are to examine the influences of polyethylene wax-based WMA additive on the optimum asphalt content of warm-recycled asphalt mixture based on the Marshall mix design and to evaluate performance of warm-recycled asphalt mixture containing 30% RAP with polyethylene wax-based WMA additive. METHODS: Physical and rheological properties of the residual asphalt were evaluated in terms of penetration, softening point, ductility and performance grade (PG) in order to examine the effects of polyethylene wax-based WMA additive on the residual asphalt. Also, To evaluate performance characteristics of the warm-recycled asphalt mixtures using polyethylene wax-based WMA additive along with a control hot-recycled asphalt mixture, indirect tensile strength test, modified Lottman test, dynamic immersion test, wheel tracking test and dynamic modulus test were conduced in the laboratory. RESULTS : Based on the limited laboratory test results, polyethylene wax-based WMA additive is effective to decrease mixing and compacting temperatures without compromising the volumetric characteristics of warm-recycled asphalt mixtures compared to hot-recycled asphalt mixture. Also, it doesn't affect the optimum asphalt content on recycled-asphalt mixture. All performance test results show that the performance of warm-recycled asphalt mixture using polyethylene wax-based WMA additive is similar to that of a control hot-recycled asphalt mixture. CONCLUSIONS: Overall, the performance of warm-recycled asphalt mixture using polyethylene wax-based WMA additive is comparable to hot-recycled asphalt mixture.