• 제목/요약/키워드: Optimum Load

검색결과 983건 처리시간 0.031초

유로코드를 이용한 주름웨브보의 최적설계 연구 (A Study on Optimum design of Corrugated web girder using Eurocode)

  • 손수덕;유미나;이승재
    • 한국공간구조학회논문집
    • /
    • 제12권4호
    • /
    • pp.47-56
    • /
    • 2012
  • This paper describes the structural design and optimization of sinusoidally corrugated web girder by using EUROCODE (EN 1993-1-5). The optimum design methodology and characteristics of the optimal cross-section are discussed. We investigate a shear buckling and the concerned standards for corrugated web and explain the equations to obtain a critical stress according to buckling type. In order to perform optimization, we consider an objective function as minimum weight of the girder and use the constraint functions as slenderness ratio and stresses of flanges as well as corrugated web and deflection. Genetic Algorithm is adopted to search a global optimum solution for this mathematical model. For numerical example, the clamped girder under the concentrated load is considered, while the optimum cross-sectional area and design variables are analyzed. From the results of the adopted example, the optimum design program of the sinusoidally corrugated web girder is able to find the suitable solution which satisfied a condition subject to constraint functions. The optimum design shows the tendency to decrease the cross-sectional area with the yielding strength increase and increase the areas with load increase. Moreover, the corrugated web thickness shows a stable increase concerning the load.

강제 송풍 증발기에 의한 자동제상장치의 최적제상시기에 관한 연구 (A Study on the Period of Optimum Defrost of Auto Defrost Unit by the Forced Fan Evaporator)

  • 구남열;이윤경;하옥남
    • 설비공학논문집
    • /
    • 제15권4호
    • /
    • pp.329-335
    • /
    • 2003
  • This study is on a experiment which shows to defrost automatically on the optimum time regardless of defrosting method. The result shows that the more defrost layers increase in fin tubes of evaporation, the less the section of the circulating air reduce. Thickness of the frost formation increases, so a pressure difference of ventilation increase, as a result automatic defrosting system sets the time COP drops suddenly up optimum time. Automatical defrosting system can find out the initial related current of evaporator fan motor and the value of load current in the optimum time. And it sets defrosting time, evaporating temperature, and temperature in refrigerator up system requiring value. Consequence of this experiment is that energy consumption with defrost load gets effect of reduction of eleven percent per 25.4 hours compared with common defrosting.

최적신뢰성에 의한 P.S.C Box Girder교의 연구 (A Study on Optimum Reliability of P.S.C Box Girder Bridge)

  • 정철원;유한신;나기현
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제3권4호
    • /
    • pp.139-144
    • /
    • 1999
  • Based on the recent developments of the reliability-based structural analysis and design as well as the extending knowledge on the probabiliistic characteristics of load and resistances, the probability based design criteria have been successfully developed for many standards. Since the probabilistic characteristics depend highly on the local load and resistances, it is recognized to develop the design criterion compatible with domestic requirements. The existing optimum design methods, which are generally based on the structural theory and certain engineering experience, do not realistically consider the uncertainties of load and resistances and the basic reliability concepts. This study is directed to propose a optimum design based Expected Total Cost Minimization on P.S.C Box Girder Bridge system which could possibly replace optimum design based traditional provisions of the current code, based on the Neldel-Mead Method reliability theory.

  • PDF

한국형 고속전철용 견인전동기의 포화현상에 따른 특성연구 (A Study on The characteristics based on the stauration effects of traction motor for korea High Speed Train)

  • 이상우;김근웅;윤종학;한성수
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 1999년도 추계학술대회 논문집
    • /
    • pp.360-367
    • /
    • 1999
  • An inverter-driven induction motor is used as the traction motor for a high speed drive system that required safety, reliabillity, performance, compact size owing to the space and weight alloted for attaching to train, etc. particularly it is possible to happen the saturation effects of flux density at constant voltage-frequency region and then increase very higher than the at lowed capacity of no-load current and temperature in any case. therefore the optimum design of core, optimum voltage-frequency ratio, adoption of high grade magnetic core have been developed and researched for preventing these problems. this paper show the saturation effects of traction rotor by measuring the induced voltage of search coil at stator teeth and presents optimum voltage-frequency ratio as well as optimum core design through the comparison with efficiency, power factor, load current and no-load current for korea high speed train.

  • PDF

확률론적인 신뢰도기준에 의한 적정설비예비율의 결정에 관한 연구 (A Study on Decision of Optimum Installed Reserve Rate using Probabilistic Reliability Criterion)

  • 박정제;최재석;윤용범;정영범
    • 전기학회논문지
    • /
    • 제57권8호
    • /
    • pp.1318-1326
    • /
    • 2008
  • This paper proposes an alternative methodology for deciding an optimum deterministic reliability level (IRR; Installed Reserve Rate) by using probabilistic reliability criterion (LOLE; Loss of Load Expectation). Additionally, case studies using the proposed method induce the characteristics of relationship between the probabilistic reliability index (LOLE) and deterministic reliability index (IRR) for 2008 and 2010 years in Korea power system. The case study presents a possibility that an optimum IRR level in Korea can be assessed using the proposed method. Korea power system has been using the LOLE criterion to determine the adequacy of installed capacity (ICAP) requirement. The criterion in Korea is that the loss of load expectation shall not exceed the available capacity more than five day in ten years (=0.5[days/year]), The probabilistic reliability evaluation and production cost simulation program which is called PRASim is used in order to evaluate the relationship and optimum IRR in this paper.

보강된 복합적층 패널의 좌굴 및 좌굴후 거동의 형상 최적설계에 관한 연구 (A Study on Shape Optimization for Buckling and Postbuckling Behavior of Stiffened Laminated Composite Panels)

  • 이광록;정기현;허성필;양원호;조명래
    • 대한기계학회논문집A
    • /
    • 제25권1호
    • /
    • pp.106-114
    • /
    • 2001
  • In this study, a shape optimization of stiffener was conducted to increase buckling load or failure load in each case with a different design value and a different objective function for stiffened laminated composite panel of I-type under compression loading. Regarding each of buckling load or failure load as objective function, optimum design was carried out. In respect of optimum design, the effects of relative length of web and cab of stiffener on buckling load or failure load of postbuckling were investigated.

Optimum Shape for Buckling and Post-Buckling Behavior of a Laminated Composite Panel with I-type Stiffeners

  • Lee, Gwang-Rog;Yang, Won-Ho;Sub, Myung-Won
    • Journal of Mechanical Science and Technology
    • /
    • 제16권10호
    • /
    • pp.1211-1221
    • /
    • 2002
  • A shape optimization of stiffener was conducted to increase buckling load or failure load with stiffened laminated composite panel of I-type under compression loading. Design variables are cap length, web length, and/or thickness under the constraint of volume constancy. The objective function is buckling load and failure load of post-buckling based on Tsai-Hill theory using ABAQUS 5.8 for analysis and Optimizer on Broydon-Fletcher Goldfarb-Sharno Method and Augmented Lagrange Multiplier Method. The effects of relative length of a web and a cap of stiffener on buckling load and failure load of post-buckling were investigated with the results of optimum design.

최적 열원용량 산정을 위한 모델건물 공조부하 시뮬레이션 분석 (Thermal Load Simulation Analysis on Model Building Estimating Optimum Heat Source Capacity)

  • 박종일;김세환;이성
    • 설비공학논문집
    • /
    • 제19권6호
    • /
    • pp.427-433
    • /
    • 2007
  • Generally, H.V.A.C load capacity in early planning phase can presume with maximum thermal load. Basic data can prove by air conditioning equipment system data analysis at existing building. There are poor and not reliable alternative presentation. In this paper, measured data after use H.V.A.C load calculation K-load program reply choosing standard building and variables simulation. And I founded peak load correlation graph and mode for several kinds of variable and contents of size. I wish that equipment designer is beaconed to produce optimum capacity at building as quantitative through this result.

다중균열 구조물의 소성붕괴거동 평가 (Evaluation of Plastic Collapse Behavior for Multiple Cracked Structures)

  • 문성인;장윤석;김영진;이진호;송명호;최영환;황성식
    • 대한기계학회논문집A
    • /
    • 제28권11호
    • /
    • pp.1813-1821
    • /
    • 2004
  • Until now, the 40% of wall thickness criterion, which is generally used for the plugging of steam generator tubes, has been applied only to a single cracked geometry. In the previous study by the authors, a total number of 9 local failure prediction models were introduced to estimate the coalescence load of two collinear through-wall cracks and, then, the reaction force model and plastic zone contact model were selected as the optimum ones. The objective of this study is to estimate the coalescence load of two collinear through-wall cracks in steam generator tube by using the optimum local failure prediction models. In order to investigate the applicability of the optimum local failure prediction models, a series of plastic collapse tests and corresponding finite element analyses for two collinear through-wall cracks in steam generator tube were carried out. Thereby, the applicability of the optimum local failure prediction models was verified and, finally, a coalescence evaluation diagram which can be used to determine whether the adjacent cracks detected by NDE coalesce or not has been developed.

로드-풀을 이용한 X-Band GaN HEMT의 최적 임피던스 분석 (Analysis of Optimum Impedance for X-Band GaN HEMT using Load-Pull)

  • 김민수;이영철
    • 한국전자통신학회논문지
    • /
    • 제6권5호
    • /
    • pp.621-627
    • /
    • 2011
  • 본 논문에서는 로드-풀을 이용하여 X-band에서 on-Wafer 상태의 GaN HEMT 소자에 대한 성능을 분석하고 분석한 결과를 바탕으로 최적의 임피던스 점을 분석하였다. 패키징 하기 전 on-Wafer 상태에 있는 반도체 소자의 최적의 임피던스 분석을 통해 소자 자체에서 최적의 성능을 내는 방안을 제안하였다. Gate length가 0.25um이고 Gate Width가 각각 400um, 800um인 소자에 대한 최적의 임피던스를 선정하여 성능을 분석한 결과, 400um는 $P_{sat}$=33.16dBm(2.06W), PAE=67.36%, Gain=15.16dBm의 성능을 가지며, 800um는 $P_{sat}$=35.9 dBm(3.9W), PAE=69.23%, Gain=14.87dB의 성능을 보였다.