• Title/Summary/Keyword: Optimum Efficiency

Search Result 2,726, Processing Time 0.027 seconds

Method of Optimum Efficiency to Coefficient of Utilization for Single Phase Induction Motor (단상 유도전동기의 이용률 변동에 대한 최적효율 산정기법)

  • Kim, Yang-Ho;Kim, Young-Sun
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.55 no.4
    • /
    • pp.155-160
    • /
    • 2006
  • In this paper, deduced suitable optimization to request output condition after taking closely characteristic data of single phase induction motor(SIM) which is the possibility becoming economic is coming to be demanded. Motor proper move connection data took advantage of result of existing data and iron loss and copper loss, mechanical loss took advantage of statistical data, and decide motor move laking advantage of saving data and secondary resistance and optimum purpose of method that is proposed through single phase induction motor and comparison performance evaluation having on the same output parameter. That decide material factor, electric power damage ratio, and coefficient of utilization for optimum function by method that search request output and optimum values of efficiency case by case and decided is proper that is saved after take magnetizing reactance relationship. This research result which it sees against a material expense with use coefficient of utilization which is included in loss expense decides the same plan variable back the place efficiency is useful and will be applied.

The Optimum Phosphor Thickness to Obtain the Highest Luminance and Luminous Efficiency in ac PDP

  • Heo, Jeong-Eun;Kim, Young-Kee;Park, Hun-Gun;Park, Chung-Hoo
    • Journal of Information Display
    • /
    • v.2 no.1
    • /
    • pp.14-19
    • /
    • 2001
  • Plasma display panel(PDP) have gained great attention due to their potential application to large-area display including HDTV. The luminance and luminous efficiency of PDP, however, should be improved to realize this goal. In this study, we examined experimentally the effects of phosphor thickness and discharge gap on the luminance and luminous efficiency of ac PDP. For the rib height of 110 ${\mu}m$, whereas the optimum phosphor thickness was about 30 ${\mu}m$. The optimum thickness of green phosphor was about 50 ${\mu}m$ for the rib height of $120{\sim}160\;{\mu}m$.

  • PDF

Analysis and Optimization based on the Fixed Fin Base Height for a Triangular Fin (삼각 핀의 해석과 고정된 핀 바닥 높이에 기준한 최적화)

  • Kang, Hyung-Suk
    • New & Renewable Energy
    • /
    • v.3 no.1 s.9
    • /
    • pp.13-19
    • /
    • 2007
  • A triangular fin with variable fin base thickness and base height is analyzed and optimized for the fixed fin base height using a two-dimensional analytical method. At the middle of the fin length, the variation of the temperature along the fin height is listed. The influences of the fin length, base thickness and base height on the heat loss and fin efficiency are analyzed, The optimum heat loss, corresponding optimum efficiency and optimum fin length as a function of the fin base thickness are presented. The optimum heat loss and optimum fin tip length as a function of the convection characteristic number are represented.

  • PDF

Reuse of the sewage from sea area using the Submerged Moving Media Complete Mixing Activated Sludge (SMMCMAS) (회전매체를 가진 완전혼합활성슬러지 공법을 이용한 온천지구 하수의 재이용)

  • 김홍태;김학석
    • Journal of Environmental Science International
    • /
    • v.11 no.1
    • /
    • pp.69-74
    • /
    • 2002
  • This study was performed to evaluate an applicability of the SMMCMAS system for reuse of the sewage from spa area and was operated to HLR(Hydraulic loading rate) of 211.3 to 126.8 $\ell$/㎥/d. The operating HRT(Hydraulic retention time) ranges were 2.5 to 1.5 hours. Conclusions are as follows; At the optimum HLR of 158.5 $\ell/\m^2$/d (HRT of 2.0 hours), the maximum BOD removal efficiency was 94% and the effluent BOD concentration was 1.1mg/$\ell$ in result. As the HLR was increased to 211.3 $\ell/\m^2$/d, BOD removal efficiency was decreased to 75% and BOD removal efficiency was also reduced to 74% at lower HLR of 126.8 $\ell/\m^2$/d. It shows that the maximum BOD removal efficiency occurs at an optimum HLR value and that the removal efficiency decreases when the HLR is either higher or lower than the optimum value. Sludge production rates were ranged 0.01 to 0.24gVSS/gBODrem/d and accomplished to 0.01gVSS/gBODrem/d at the optimum HLR of 158.5 $\ell/\m^2$/d.

Optimum Design of a Y-channel Microcmixer for Enhanced Mixing (혼합 개선을 위한 Y-채널 마이크로 믹서의 최적설계)

  • Shin Yong-Su;Choi Hyung-Il;Lee Dong-Ho;Lee Do-Hyung
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.30 no.3 s.246
    • /
    • pp.302-309
    • /
    • 2006
  • Effective mixing plays a crucial role in microfluidics for biochemical applications. Owing to the small device scale and its entailing the low Reynolds number, the mixing in microchannels proceeds very slowly. In this work, we optimize the configuration of obstacles in the Y-channel mixer in order to attain maximum mixing efficiency. Before the optimum design, mixing characteristics are investigated using unstructured grid CFD method. Then, the analysis method is employed to construct the approximate analysis model to be used in the optimization procedure. The main optimization tool in the present work is sequential quadratic programming method. Using this approximate optimization procedure, we may obtain the optimum layout of obstacles in the Y-channel mixer in an efficient manner, which gives the maximum mixing efficiency.

A STUDY ON THE PROTEIN AND ENERGY REQUIREMENTS OF MUSCOVY DUCKLINGS

  • Ali, M.A.;Sarker, G.A.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.5 no.1
    • /
    • pp.69-73
    • /
    • 1992
  • Two experiments were conducted with one-day-old straight run Muscovy ducklings to determine their protein and energy requirements. In the 1st experiment, isoenergetic diets (2800 kcal ME/kg) with three dietary proteins, 18, 20 and 22% in the starter period (1-28 days) and 16, 18 and 20% in the grower and finisher period (29-84 days) were used to determine the optimum protein requirement. While, in the 2nd experiment, isonitrogenous diets (20%, C.P.) with three dietary energy, 2700, 2800 and 2900 kcal ME/kg in the starter period (1-28 days) and (18% C.P.) with 2800, 2900 and 3000 kcal ME/kg in the grower-finisher period (29-84 days) were used to determine the optimum energy requirement. It was observed that 20% C.P. in the starter period and 18% C.P. in the grower and finisher period was adequate for optimum performance, while, 2900 kal ME/kg was sufficient to meet the optimum energy requirement in both the starter, grower-finisher period as regards body weight, feed efficiency, protein efficiency and caloric efficiency are concerned.

A Study on the Development of Analytical Method for Micro-odorous Compounds in Water (흡착제를 이용한 수중의 미량 이취물질 분석법 개발에 관한 연구)

  • Kim, Eun-Ho;Son, Hee-Jong;Kim, Yeong-Ung;Kim, Hyeong-Seok;Sung, Nak-Chang
    • Journal of Environmental Health Sciences
    • /
    • v.25 no.3
    • /
    • pp.103-107
    • /
    • 1999
  • Even if odorous compounds remain very low concentration in water, it cause strong odor. Because Geosmin and most of odorous compound had very low vaporization, those were difficult to analyze with GC/MSD and Purge & Trap. So, we needed pre-treatment method for decreasing amounts of extracting solvents, improving recovery efficiencies and increasing analytical efficiencies. This study developed efficient technology for analyzing odorous compounds, using various adsorbents and extracting solvents. The optimum adsorbent was XAD resins. Especially, XAD-2, XAD-7 and XAD-2010 were superior, but XAD-2 of these and the optimum extraction solvent is MTBE. Other extraction solvents' efficiency is in order of MTBE>Dichloromethane>n-Hexane>Diethylether. The optimum NaCl dosage for increasing efficiency is 5 g in liquid-liquid extraction method. The shaking time(0~24hr) has no concern with adsorption efficiency. The optimum adsorbent is XAD-2 resin and extraction solvent is MTBE. Dosing NaCl, adsorption efficiency is increased in liquid-liquid extraction method, but NaCl has no effect on liquid-solid extraction method. In this experimental results, this algae toxins(Mycrocystin, Anatoxin etc.).

  • PDF

A Study on the Development of Analytical Method for Micro-Odorous Compounds in Water (흡착제를 이용한 수중의 미량 이취물질 분석법 개발에 관한 연구)

  • 김은호;성낙창;최용락
    • Journal of Life Science
    • /
    • v.9 no.5
    • /
    • pp.575-580
    • /
    • 1999
  • Even if odorous compounds remained very low concentration in water, it caused strong odor. Because Geosmin and most of odorous compound had very vaporization, those were difficult to analyze with GC/MSD and Purge & Trap. So, we needed pre-treatment method for decreasing amounts of extracting solvents, improving recovery efficiencies and increasing analytical efficiencies. This study developed efficient technology for analyzing odorous compounds, using various adsorbents and extracting solvents. The optimum adsorbent was XAD resins. Especially, XAD-2, XAD-7 and XAD-2010 were superior, but XAD-2 of these and MTBE was the optimum extraction solvent. Other extraction solvent's efficiency was in order of MTBE>Dichloromethane>n-Hexane>Diethylether. The optimum NaCl dosage for increasing efficiency was 5g in liquid-liquid extraction method. The shaking time(0∼24hr) had no concern with adsorption efficiency. The optimum adsorbent was XAD-2 resin and extraction solvent was MTBE. Dosing NaCl, adsorption efficiency was increased in liquid-liquid extraction method, but NaCl has no effect on liquid-solid extraction method. In this experimental results, this method will apply to not only Geosmin but other well-known odorous compounds (2-MIB, IBMP, IPMP, TCA) and algae toxins (Mycrocystin, Anatoxin etc)

  • PDF

Investigation of Single-Input Multiple-Output Wireless Power Transfer Systems Based on Optimization of Receiver Loads for Maximum Efficiencies

  • Kim, Sejin;Hwang, Sungyoun;Kim, Sanghoek;Lee, Bomson
    • Journal of electromagnetic engineering and science
    • /
    • v.18 no.3
    • /
    • pp.145-153
    • /
    • 2018
  • In this paper, the efficiency of single-input multiple-output (SIMO) wireless power transfer systems is examined. Closed-form solutions for the receiver loads that maximize either the total efficiency or the efficiency for a specific receiver are derived. They are validated with the solutions obtained using genetic algorithm (GA) optimization. The optimum load values required to maximize the total efficiency are found to be identical for all the receivers. Alternatively, the loads of receivers can be adjusted to deliver power selectively to a receiver of interest. The total efficiency is not significantly affected by this selective power distribution. A SIMO system is fabricated and tested; the measured efficiency matches closely with the efficiency obtained from the theory.

A Fuzzy Logical Optimal Efficiency Control of Permanent Magnet Synchronous Motor (PMSM의 퍼지 로직 최적 효율 제어)

  • Zhou, Guang-Xu;Lee, Dong-Hee;Ahm, Jin-Woo
    • Proceedings of the KIEE Conference
    • /
    • 2007.04c
    • /
    • pp.97-99
    • /
    • 2007
  • This paper presents a fuzzy logical control method to implement an on-line optimum efficiency control for Permanent Magnet Synchronous Motor. This method real-timely adjusts the output voltage of the inverter system to achieve the optimum running efficiency of the whole system. At first, the input power is calculated during the steady state in the process of efficiency optimizing. To exactly estimate the steady state of the system, this section needs check up the speed setting on timely. The second section is to calculate input power of dc-bus. The exact measurement of the voltage and current is the vital point to acquire the input power. The third section is the fuzzy logic control unit, which is the key of the whole drive system. Based on the change of input power of dc-bus and output voltage, the variable of output voltage is gained by the fuzzy logical unit. With the on-line optimizing. the whole system call fulfill the minimum input power of dc-bus on the running state. The experimental result proves that the system applied the adjustable V/f control method and the efficiency-optimizing unit possesses optimum efficiency, and it is a better choice for simple variable speed applications such as fans and pump.

  • PDF