• Title/Summary/Keyword: Optimized injection protocol

Search Result 5, Processing Time 0.02 seconds

Optimization of Protocol for Injection of Iodinated Contrast Medium in Pediatric Thoracic CT Examination (소아 흉부 CT검사에서 조영제 주입에 관한 프로토콜의 최적화)

  • Kim, Yung-Kyoon;Kim, Yon-Min
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.6
    • /
    • pp.879-887
    • /
    • 2019
  • The purpose of this study is to establish a physiological injection protocol according to body weight, in order to minimize amount of contrast medium and optimize contrast enhancement in pediatric patients performing thoracic CT examinations. The 80 pediatric patients under the age of 10 were studied. Intravenous contrast material containing 300 mgI/ml was used. The group A injected with a capacity of 1.5 times its weight, and groups B, C and D added 5 to 15 ml of normal saline with a 10% decrease in each. The physiologic model which can be calculated by weight about amount of injection of contrast medium and normal saline, flow rate and delay time were applied. To assess image quality, measured average HU value and SNR of superior vena cava, pulmonary artery, ascending and descending aorta, right and left atrium, right and left ventricle. CT numbers of subclavian vein and superior vena cava were compared to identify the effects of reducing artifacts due to normal saline. Comparing SNR according to the contrast medium injection protocol, significant differences were found in superior vena cava and pulmonary artery, descending aorta, right and left ventricle, and CT numbers showed significant differences in all organs. In particular, B group with a 10% decrease in contrast medium and an additional injection of saline showed a low degree of contrast enhancement in groups with a decrease of more than 20%. In addition, the group injected with normal saline greatly reduced contrast enhancement of subclavian vein and superior vena cava, and the beam hardening artifact by contrast medium was significantly attenuated. In conclusion, the application of physiological protocol for injection of contrast medium in pediatric thoracic CT examinations was able to reduce artifacts by contrast medium, prevent unnecessary use of contrast medium and improve the effect of contrast enhancement.

Automated radiosynthesis for the routine production of [18F]FPEB for imaging metabotropic glutamate receptor 5 (mGluRS)

  • Kyung Rok Nam;Sang Jin Han;Kyo Chul Lee;Jae Yong Choi
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.8 no.1
    • /
    • pp.3-8
    • /
    • 2022
  • Alteration of the mGluR5 density is closely related to various brain diseases including schizophrenia, depression, Parkinson's disease, and Alzheimer's disease. Therefore, mGluR5 is considered as a valuable imaging biomarker for brain disease and many radiopharmaceuticals have been developed so far. Among them, [18F]FPEB has favorable pharmacokinetic characteristics, and this is the most frequently used radiopharmaceutical for preclinical and clinical studies. In the present study, we want to introduce the optimized radiosynthetic method for the routine production of [18F]FPEB using a GE TRACERlabTM FXFN pro module. In addition, the entire process was monitored with a webcam to solve the problems arising from the synthetic process. As a result, [18F]FPEB was prepared by nucleophilic substitution from its nitro- precursor at 120℃ for 20 min in dimethyl sulfoxide. Radiochemical yield was 13.7 ± 5.1% (decay-corrected, n = 91) with the molar activity of 84 ± 17 GBq/µmol at the end of synthesis. The radiochemical purity was determined to be above 96%. The manufactured [18F]FPEB injection for quality controls were carried out in accordance with an KIRAMS approved protocol, as per ICH and USP guidelines.

Analysis of Vitellogenin Gene Expression by RT-PCR in Hemibarbus labeo (Cyprinidae) for the Analysis of Estrogenic Activity in Aquatic Environment (수환경 내 Estrogen 에스트로젠 활성 검출을 위한 누치 난황전구단백질 유전자 발현의 RT-PCR시험법)

  • Gye, Myung-Chan
    • Korean Journal of Ecology and Environment
    • /
    • v.37 no.1 s.106
    • /
    • pp.122-129
    • /
    • 2004
  • In an effort to develop the biomarker for monitoring the contamination of xenoestrogen in the freshwater environment of Korea, reverse transcription-polymerasechain reaction (RT-PCR) analysis of vitellogenin (VTG) gene expression was optimized in Hearisarsus Iaseo, Based on the homology of the VTG cDNA sequences between the common carp and zebra fish, a set of PCR primers for VTG mRNA amplification for H; labo was designed. VTG mRNA level in livers from female and male fishes was analyzed by RT-PCR following single injection of 17 beta estradiol($E_2$ 10 mg $kg^{-1}$ B.W.). As an internal control, beta actin mRNA was amplified. One us of total liver RNA was subjected to RT-PCR. In female the amount of PCR productof VfC gradually increased in the range from 16 to 34 cycles of amplification. On the contrary, in control male, PCR product first detected at 32 cycles of amplification and linearly increased up to 40 cycles of amplification. In $E_2$ injected male liver, the VTC mRNA level was similar to that in the female. Taken together, this result suggests that liver of male H. labo expresses minute amount of VTG mRNA which are2-l6 equivalent of female and that induction of VTG mRNA occurs in male liver after estrogen treatment. In conclusion, the optimized protocol for RT-PCR analysis of VTG mRNA expression in liver of male H. labo will provide the environmental monitoring method for the xenoestrogen contamination in the rivers in Korea.

Implementation of ECO Driving Assistance System based on IoT (IoT기반 ECO 운전보조 시스템 구현)

  • Song, Hyun-Hwa;Choi, Jin-ku
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.20 no.2
    • /
    • pp.157-163
    • /
    • 2020
  • Recently, fine dust has been known to cause cardiovascular diseases here, raising interest in ways to reduce emissions by efficiently using fuel from cars that cause air pollution. Accordingly, a driving assistance system was developed to save fuel by eco-driving and improve the driver's bad driving habits. The system was developed using raspberry pi, arduino and Android. Using RPM, speed, fuel injection information obtained from OBD-II, and gyro-sensor values, Fuel-Cut is induced to create an optimal inertial driving environment. It also provides various information system such as weather, driving environment, and preventing drowsy driving through GUI and voice recognition functions. It is possible to check driving records and vehicle fault information using Android application and has low overhead for message transmission using MQTT protocol optimized for IoT environment.

The Variation of Scan Time According to Patient's Breast Size and Body Mass Index in Breast Sentinel lymphangiography (유방암의 감시림프절 검사에서 유방크기와 체질량지수에 따른 검사시간 변화)

  • Lee, Da-Young;Nam-Koong, Hyuk;Cho, Seok-Won;Oh, Shin-Hyun;Im, Han-Sang;Kim, Jae-Sam;Lee, Chang-Ho;Park, Hoon-Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.62-67
    • /
    • 2012
  • Purpose : At this time, the sentinel lymph node mapping using radioisotope and blue dye is preceded for breast cancer patient's sentinel lymph node biopsy. But all patients were applied the same protocol without consideration of physical specific character like the breast sizes and body mass indexes. The purpose of this study is search the optimized scan time in breast sentinel lymphangiography by observing how much the body mass index and breast size influence speed of lymphatic flow. Materials and Methods : The Object of this study was 100 breast cancer patients(Female, 100 persons, average age $50.34{\pm}10.26$ years old)at Severance hospital from October 2011 to December 2011. They were scanned breast sentinel lymphangiography before operation. This study was performed on Forte dual heads gamma camera (Philips Medical Systems, Nederland B.V.). All patients were intra-dermal injected $^{99m}Tc$-Phytate 18.5 MBq, 0.5 ml. For 80 patients, we have scanned without limitation of scan time until the lymphatic flow from the lymph node since injection. We measured how long the lymphatic flow time between departures from injects site and arrival to lymph node using stopwatch. After we calculated patient's Body mass Index and classified as 4 groups. And we measured patient's breast size and classified 3 groups. The modified breast lymphangiography that changing scan time according to comparison study's result was performed on 20 patients and was estimated. Results : The mean scan time as breast size was A group 2.48 minutes, B group 7.69 minutes, C group 10.43 minutes. The mean scan time as body mass index was under weight 1.35 minutes, normal weight 2.56 minutes, slightly over 5.62 minutes, over weighted 5.62 minutes. The success rate of modified breast lymphangiography was 85%. Conclusion : As the Body mass index became higher and breast size became bigger, the total scan time is increased. Based on the obtained information, we designed modified breast lymphangiography protocol. At the cases applying that protocol, most of sentinel lymph nodes were visualized as lymphatic pool. In conclusion, we found that the more success rate in modified protocol considering physical individuality than study carrying out in the same protocol.

  • PDF