• 제목/요약/키워드: Optimized Location

검색결과 265건 처리시간 0.043초

정보 입자화와 유전자 알고리즘에 기반한 자기구성 퍼지 다항식 뉴럴네트워크의 새로운 접근 (A New Approach of Self-Organizing Fuzzy Polynomial Neural Networks Based on Information Granulation and Genetic Algorithms)

  • 박호성;오성권;김현기
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제55권2호
    • /
    • pp.45-51
    • /
    • 2006
  • In this paper, we propose a new architecture of Information Granulation based genetically optimized Self-Organizing Fuzzy Polynomial Neural Networks (IG_gSOFPNN) that is based on a genetically optimized multilayer perceptron with fuzzy polynomial neurons (FPNs) and discuss its comprehensive design methodology involving mechanisms of genetic optimization, especially information granulation and genetic algorithms. The proposed IG_gSOFPNN gives rise to a structurally optimized structure and comes with a substantial level of flexibility in comparison to the one we encounter in conventional SOFPNNs. The design procedure applied in the construction of each layer of a SOFPNN deals with its structural optimization involving the selection of preferred nodes (or FPNs) with specific local characteristics (such as the number of input variables, the order of the polynomial of the consequent part of fuzzy rules, and a collection of the specific subset of input variables) and addresses specific aspects of parametric optimization. In addition, the fuzzy rules used in the networks exploit the notion of information granules defined over system's variables and formed through the process of information granulation. That is, we determine the initial location (apexes) of membership functions and initial values of polynomial function being used in the premised and consequence part of the fuzzy rules respectively. This granulation is realized with the aid of the hard c-menas clustering method (HCM). To evaluate the performance of the IG_gSOFPNN, the model is experimented with using two time series data(gas furnace process and NOx process data).

음원을 둘러싼 인클로저 개구부를 통해 전파되는 소음의 능동 제어 (Active Control of Propagated Noise through Opening of Enclosures Surrounding a Noise Source)

  • 이한울;홍진숙;정의봉
    • 한국소음진동공학회논문집
    • /
    • 제25권4호
    • /
    • pp.223-231
    • /
    • 2015
  • Enclosures are widely used to alleviate the contribution of machinery noise. It has been long concerned with the noise transmission through the access openings of the enclosures. In this study, we investigate active noise control technology for reduction of the transmission. A numerical model based on the acoustic boundary element method is first established. Using the numerical model, the acoustic transfer functions of the field points over the opening to the primary source at arbitrary locations are estimated. The feedforward control to minimize the acoustic power through the opening is then numerically implemented. The controller drives the secondary source to destructively interfere the noise transmission through the opening. Finally, a parametric study is conducted to evaluate the effects of the location and the number of the microphones on the control performance. Furthermore, the effects of the location of the secondary source on the performance of active noise control are investigated. It is followed that the control system implemented in this study leads to a significant reduction of about 31.5 dB in the sound power through the opening using only one secondary source located at the optimized position.

LBS를 활용한 문화유산 체험학습 스마트폰 APP (Cultural Heritage Experiential Learning Smart-Phone APP Using LBS)

  • 김용호;김형균
    • 디지털융복합연구
    • /
    • 제11권12호
    • /
    • pp.821-828
    • /
    • 2013
  • 본 논문에서 제안한 문화유산 체험학습에 최적화된 스마트폰 APP인 CHELS-App은 단순한 관광지안내 서비스를 벗어나 스마트폰을 활용하여 문화유산을 체험하고 제시되는 퀘스트를 통하여 미션을 즐기면서 학습과 관광을 동시에 체험할 수 있도록 구성하였다. CHELS-App은 세계문화유산으로 지정되어 있는 종묘를 대상으로 위치기반 서비스를 이용한 안내지도와 이벤트 푸쉬기능을 이용한 현장에서의 다양한 문화해설(해설, 사진, 퀴즈, 게임, 카툰)을 제공하고 이러한 체험을 통한 발도장 기능, 체험일지 작성 기능을 구성하였다.

철도 터널구간 애자류 오염도 분석에 관한 연구 (A research on the tunnel insulator pollution characteristic in Korea Railroad)

  • 전용주;이태훈;최경일;이시빈;한상길
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.1169_1170
    • /
    • 2009
  • This paper introduces insulator pollutant accumulate pattern in the tunnel of korea railroad. To accomplish this goal, effective sample collecting method was proposed for the first step. Dust at the surface was collected directly. Distilled water and brush was used while collecting. Through this method dust is easily and accurately collected. The second step is pollutant analysis. Several analyze item is selected such as quantity, conductivity, contact angle, Optical Microscope(OM), IR, Equivalent Salt Deposit Density(ESDD), and ICP-AES. The third step, best represent tunnel was selected considering location, length and natural surroundings. Also to consider the difference at inside the tunnel, several bracket insulators were selected along to the location. To make the result precise, above procedure was repeated several times at the same target. Finally relation among type of train, numbers of movement, surroundings, length will be considered in combination with the pollution. With this result pollute map for KORAIL could be accomplished and inspect period will be optimized case by case.

  • PDF

Congestion Management in Deregulated Power System by Optimal Choice and Allocation of FACTS Controllers Using Multi-Objective Genetic Algorithm

  • Reddy, S. Surender;Kumari, M. Sailaja;Sydulu, M.
    • Journal of Electrical Engineering and Technology
    • /
    • 제4권4호
    • /
    • pp.467-475
    • /
    • 2009
  • Congestion management is one of the technical challenges in power system deregulation. This paper presents single objective and multi-objective optimization approaches for optimal choice, location and size of Static Var Compensators (SVC) and Thyristor Controlled Series Capacitors (TCSC) in deregulated power system to improve branch loading (minimize congestion), improve voltage stability and reduce line losses. Though FACTS controllers offer many advantages, their installation cost is very high. Hence Independent System Operator (ISO) has to locate them optimally to satisfy a desired objective. This paper presents optimal location of FACTS controllers considering branch loading (BL), voltage stability (VS) and loss minimization (LM) as objectives at once using GA. It is observed that the locations that are most favorable with respect to one objective are not suitable locations with respect to other two objectives. Later these competing objectives are optimized simultaneously considering two and three objectives at a time using multi-objective Strength Pareto Evolutionary Algorithms (SPEA). The developed algorithms are tested on IEEE 30 bus system. Various cases like i) uniform line loading ii) line outage iii) bilateral and multilateral transactions between source and sink nodes have been considered to create congestion in the system. The developed algorithms show effective locations for all the cases considered for both single and multiobjective optimization studies.

태양광어레이 최적화에 의한 단위 부지면적당 발전량 개선 (Improvement of generation capacity per unit site area by the optimization of photovoltaic array)

  • 김의환
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2011년도 춘계학술대회 초록집
    • /
    • pp.109.2-109.2
    • /
    • 2011
  • A photovoltaic system is getting the spotlight for a environment-friendly energy source. But its location is limited because a lot of land is necessary for photovoltaic arrays. Nevertheless, its dissemination is rapidly increasing more than 40 % every year and exceeded about 400 MW in 2009. The radical growth of a photovoltaic system aggravated a lack of sites, so that forests and farmland were destroyed. It is demanded to make use of a vacant lot or little piece of land for the way to solve the lack of sites and improve the location requirements for a photovoltaic system. General photovoltaic arrays are consist of a single layer structure and needs enough separation distances to maximize the amount of solar radiation and to eliminate influences by the shadow of other arrays. So that a large amount of land is required for the site. The solar cell arrays with long separation distances can not be placed in a small vacant lot and its site application efficiency is low. This study optimized photovoltaic arrays as multilayered structure with movable sleeves for the efficient photovoltaic in a small site. The existing photovoltaic arrays with a single layer structure were fixed or tracking systems. In this experimental equipment, photovoltaic arrays attached to the multilayers have rectilinear movement and rotary motion using sleeves. Therefore, shadow influences were removed and the generation capacity was improved. On the simulation result, generation increased by about 30% in the same site considering shadow influences and so on.

  • PDF

Adaptive location of repaired blade for multi-axis milling

  • Wu, Baohai;Wang, Jian;Zhang, Ying;Luo, Ming
    • Journal of Computational Design and Engineering
    • /
    • 제2권4호
    • /
    • pp.261-267
    • /
    • 2015
  • Free-form blades are widely used in different industries, such as aero-engine and steam turbine. Blades that are damaged during service or have production deficiencies are usually replaced with new ones. This leads to the waste of expensive material and is not sustainable. However, material and costs can be saved by repairing of locally damaged blades or blades with localized production deficiencies. The blade needs to be further machined after welding process to reach the aerodynamic performance requirements. This paper outlines an adaptive location approach of repaired blade for model reconstruction and NC machining. Firstly, a mathematical model is established to describe the localization problem under constraints. Secondly, by solving the mathematical model, localization of repaired blade for NC machining can be obtained. Furthermore, a more flexible method based on the proposed mathematical model and the continuity of the deformation process is developed to realize a better localization. Thirdly, by rebuilding the model of the repaired blade and extracting repair error, optimized tool paths for NC machining is generated adaptively for each individual part. Finally, three examples are given to validate the proposed method.

마이크로 가스터빈을 위한 하이브리드/이중 선회제트 연소기의 개발 (Part II: 비반응 유동구조에 관한 수치해석) (Development of a Hybrid/Dual Swirl Jet Combustor for a Micro-Gas Turbine (Part II: Numerical Analysis on Isothermal Flow Structure))

  • 문선여;황해주;황철홍;이기만
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2012년도 제44회 KOSCO SYMPOSIUM 초록집
    • /
    • pp.201-202
    • /
    • 2012
  • The isothermal flow structure and mixing characteristics of a hybrid/dual swirl jet combustor for micro-gas turbine were numerically investigated. Location of pilot nozzle, angle and direction of swirl vane were varied as main parameters with constant fuel flow rates for each nozzle. As a result, the variation in location of pilot nozzle resulted in significant change in turbulent flow field near burner exit, in particular, center toroidal recirculation zone (CTRZ) as well as turbulent intensity, and thus flame stability and emission characteristics might be significantly changed. The swirl angle of $45^{\circ}$ provided similar recirculating flow patterns in a wide range of equivalence ratio (0.5~1.0). Compared to the co-swirl flow, the counter-swirl flow leaded to the reduction in CTRZ and fuel-air mixing near the burner exit and a weak interaction between the pilot partially premixed flame and the lean premixed flame. With the comparison of experimental results, it was confirmed that the case of co-swirl flow and swirl $angle=45^{\circ}$ would provided an optimized combustor performance in terms of flame stability and pollutant emissions.

  • PDF

음원을 둘러싼 인클로저 개구부를 통해 투과되는 소음의 능동 제어 (Active Control of Transmitted Noise through Opening of Enclosures Surrounding a Noise Source)

  • 이한울;홍진숙;정의봉
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2013년도 춘계학술대회 논문집
    • /
    • pp.796-802
    • /
    • 2013
  • In this study, we investigates active control technology to reduce the noise transmitted to the outside through the opening of enclosures. A numerical model based on acoustic boundary element method is first established. Using the numerical model, the acoustic transfer functions of the field points over the opening to the primary source at arbitrary locations are estimated. The feedforward control to minimize the acoustic power through the opening is then numerically implemented. The controller generates the secondary source to destructively interfere the noise transmission through the opening. Finally, a parametric study is conducted to evaluate the effects of the location and the number of the microphones on the control performance. Furthermore, the effects of the location of the secondary source on the performance of active noise control are investigated. It is followed that the control system implemented in this study leads to a significant reduction of about 35dB in sound power through the open using only on secondary source located at the optimized position.

  • PDF

민감도가 고려된 유전 알고리듬을 이용한 보 구조물의 지지점 최적화에 관한 연구 (A Study on the Support location Optimizations of the Beams using the Genetic Algorithm and the Sensitivity Analysis.)

  • 이재관;신효철
    • 소음진동
    • /
    • 제10권5호
    • /
    • pp.783-791
    • /
    • 2000
  • This describes a study on the support location optimizations of the beams using the genetic algorithm and the sensitivity analysis. The genetic algorithm is a probabilistic method searching the optimum at several points simultaneously and requiring only the values of the object and constraint functions. It has therefore more chances to find the global solution and can be applied to the various problems. Nevertheless, it has such a shortcoming that it takes too many calculations, because it is ineffective in local search. While the traditional method using sensitivity analysis is of great advantage in searching the near optimum. thus the combination of the two techniques will make use of the individual advantages, that is, the superiority in global searching form the genetic algorithm and that in local searching form the sensitivity analysis. In this thesis, for the practical applications, the analysis is conducted by FEB ; and as the shapes of structures are taken as the design variation, it requires re-meshing for every analysis. So if it is not properly controlled, the result of the analysis is affected and the optimized solution amy not be the real one. the method is efficiently applied to the problems which the traditional methods are not working properly.

  • PDF