• 제목/요약/키워드: Optimal power flow

검색결과 545건 처리시간 0.027초

Optimal Voltage and Reactive Power Scheduling for Saving Electric Charges using Dynamic Programming with a Heuristic Search Approach

  • Jeong, Ki-Seok;Chung, Jong-Duk
    • Journal of Electrical Engineering and Technology
    • /
    • 제11권2호
    • /
    • pp.329-337
    • /
    • 2016
  • With the increasing deployment of distributed generators in the distribution system, a very large search space is required when dynamic programming (DP) is applied for the optimized dispatch schedules of voltage and reactive power controllers such as on-load tap changers, distributed generators, and shunt capacitors. This study proposes a new optimal voltage and reactive power scheduling method based on dynamic programming with a heuristic searching space reduction approach to reduce the computational burden. This algorithm is designed to determine optimum dispatch schedules based on power system day-ahead scheduling, with new control objectives that consider the reduction of active power losses and maintain the receiving power factor. In this work, to reduce the computational burden, an advanced voltage sensitivity index (AVSI) is adopted to reduce the number of load-flow calculations by estimating bus voltages. Moreover, the accumulated switching operation number up to the current stage is applied prior to the load-flow calculation module. The computational burden can be greatly reduced by using dynamic programming. Case studies were conducted using the IEEE 30-bus test systems and the simulation results indicate that the proposed method is more effective in terms of saving electric charges and improving the voltage profile than loss minimization.

Optimization of Peltier Current Leads Cooled by Two-Stage Refrigerators

  • Jeong, Eun-Soo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제14권3호
    • /
    • pp.94-101
    • /
    • 2006
  • A theoretical investigation to find thermodynamically optimum design conditions of conduction-cooled Peltier current leads is performed. A Peltier current lead (PCL) is composed of a thermoelectric element (TE), a metallic lead and a high temperature superconductor (HTS) lead in the order of decreasing temperature. Mathematical expressions for the minimum heat flow per unit current crossing the TE-metal interface and the minimum heat flow per unit current from the metal lead to the joint of the metal and the HTS leads are obtained. It is shown that the temperature at the TE -metal interface possesses a unique optimal value that minimizes the heat flow to the joint and that this optimal value depends on the material properties of the TE and the metallic lead but not the joint temperature nor electric current. It is also shown that there exists a unique optimal value for the joint temperature between the metal and the HTS leads that minimizes the sum of the power dissipated by ohmic heating in the current leads and the refrigerator power consumed to cool the lead, for a given length of the HTS.

Aerodynamic design and optimization of a multi-stage axial flow turbine using a one-dimensional method

  • Xinyang Yin;Hanqiong Wang;Jinguang Yang;Yan Liu;Yang Zhao;Jinhu Yang
    • Advances in aircraft and spacecraft science
    • /
    • 제10권3호
    • /
    • pp.245-256
    • /
    • 2023
  • In order to improve aerodynamic performance of multi-stage axial flow turbines used in aircraft engines, a one-dimensional aerodynamic design and optimization framework is constructed. In the method, flow path is generated by solving mass continuation and energy conservation with loss computed by the Craig & Cox model; Also real gas properties has been taken into consideration. To obtain an optimal result, a multi-objective genetic algorithm is used to optimize the efficiencies and determine values of various design variables; Final design can be selected from obtained Pareto optimal solution sets. A three-stage axial turbine is used to verify the effectiveness of the developed optimization framework, and designs are checked by three-dimensional CFD simulation. Results show that the aerodynamic performance of the optimized turbine has been significantly improved at design point, with the total-to-total efficiency increased by 1.17% and the total-to-static efficiency increased by 1.48%. As for the off-design performance, the optimized one is improved at all working points except those at small mass flow.

공조장치내의 직렬-직렬 대향류 냉각기에서 최적 변수 (The optimal parameters in series-series counterflow chillers system within air conditioning)

  • 웬민푸;뷔옥훙;이근식
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.1332-1336
    • /
    • 2009
  • If water-chillers are arranged in series-series counterflow, compressor lift of each chiller will be decreased in comparison with water-chillers in parallel. That means that compressor power of the chillers in series will be lower than that of chillers in parallel. However, the pressure drop of the water flow through the chillers in series will increase, and thus increase the power of water pumps. This disadvantage will be made good by increasing the temperature difference of water flow through evaporator and condenser, but the water flow rates will decrease. This paper explores the optimal parameters in system of series-series counterflow for central chilled water plants such as the leaving chilled water temperature, the leaving condenser water temperature, condenser water flow rate and number of chillers in series.

  • PDF

기어펌프.모터 이끝 틈새의 영향에 관한 연구 (A Study on the Effect of Gear Teeth End-Gaps for Hydraulic Gear Pumps and Motors)

  • 정헌술;풍려려;오석형
    • 유공압시스템학회논문집
    • /
    • 제2권4호
    • /
    • pp.23-29
    • /
    • 2005
  • In order to improve the efficiency of hydraulic gear pumps or motors especially for high operating pressure, power losses due to viscous friction and leak flow through gear teeth end-gaps are considered in this paper. Optimal gaps minimizing the power loss for pumps and motors with uniform heights of gaps are analysed first. And the effect of the shapes of gaps with unequal heights on the power loss are studied and discussed by simulation. Considering that the outer shell lacing gear teeth may expand due to high internal pressure or thermal stress, the results drawn in this paper can be used for the design of high efficiency pumps and motors.

  • PDF

지역가격체계의 전력시장에 최적 한계손실계수 적용에 관한 연구 (A Study of applying Optimal MLF for Zonal Pricing Electricity market)

  • 신동준;고용준;김진오;이효상
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 A
    • /
    • pp.13-15
    • /
    • 2000
  • This paper suggests the optimal dispatch method by MLF, that gives the appropriate price signal considering power flow and system losses under zonal pricing market. This price signal with MLF effects to dispatch merit order and customer price in the short term, and to connection point of new plant in the long term. In the case study, optimal MLF dispatch method applied to simplified Korean power system. The result shows reduction of loss and northward flow.

  • PDF

The Power Flow Control of UPFC for Cost Minimization

  • Lim, Jung-Uk;Moon, Seung-Il
    • KIEE International Transactions on Power Engineering
    • /
    • 제12A권1호
    • /
    • pp.31-35
    • /
    • 2002
  • This paper presents a new operation scheme of UPFC to minimize both generation costs and active power losses in a normal operation state of power system. In a normal operation, cost minimization is a matter of primary concern among operating objectives. This paper considers two kinds of costs, generation costs and transmission losses. The total generation cost of active powers can be minimized by optimal power flow, and active power losses in the transmission system can be also minimized by power flow control of UPFC incorporated with minimization of generation costs. In order to determine amounts of active power reference of each UPFC required for the cost minimization, an iterative optimization algorithm based on the power flow calculation using the decoupled UPFC model is proposed. For verification of the proposed method, intensive studies have been performed on a 3-unit 6-bus system equipped with a UPFC.

전압안정도 및 과도 안정도틀 고려한 모선가격 산정 (Nodal price of the power system considering voltage and transient stability)

  • 김용하;이범;최상규;조성린;정현성;오석현;김동근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 A
    • /
    • pp.129-130
    • /
    • 2006
  • This paper presents a optimal power flow calculation algorithm considering voltage and transient stability. In this method, voltage stability margin and transient stability constraints is incorporated into a optimal power flow calculation formulation to guarantee adequate voltage and transient security levels in power system. In addition, this paper provides the Effect of Nodal Price and decomposed Element in Power System Operation. This Effect can be applied in the Estimation of Electric rates because the Electric market will be Competitive Market. The proposed method is applied to IEEE-24 Reliability Test System and the results shows the effectiveness of the method.

  • PDF

상정사고를 고려하는 최적 조류 계산의 분산 병렬 처리 기법에 관한 연구 (An Efficient Distributed Parallel Processing Method in Security Constrained Optimal Power Flow)

  • 김진호;허돈;박종근;김발호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 C
    • /
    • pp.997-999
    • /
    • 1998
  • An operationally secure power system is one low probability of blackout or equipment damage. The power system is needed to maintain a designated security level at minimum operating cost. The inclusions of security make power system problem complex. But, because security and optimality are normally conflicting requirement, the separate treatments of both are inappropriate. So, a unified hierarchical formulation is needed. In this paper, the overview of security constrained optimal power flow (SCOPF) is presented and an introduction of parallel distributed formulation to SCOPF is also presented.

  • PDF

전력시스템 경제부하배분의 단발적 해법 (A Single Step Solution of Economic Load Dispatch in Power System)

  • 이봉용;심건보
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 추계학술대회 논문집 학회본부
    • /
    • pp.15-17
    • /
    • 1994
  • The economic operation in power systems has long been in keen interests for power system engineers. The classical equal incremental fuel cost rule is still the basis for it, even though more elaborate tools such as optimal power flow have been developed already. The classical method requires usually many iterations, while the optimal power flow shows often some difficulties. This paper suggests a single step solution based on the classical method revisited. The concept is shown graphically. Three sample systems are compared. The proposed approach has shown a single step solution regardless system sizes, while the conventional methods require many iterations.

  • PDF