• 제목/요약/키워드: Optimal Order Point

Search Result 427, Processing Time 0.03 seconds

Strategies about Optimal Measurement Matrix of Environment Factors Inside Plastic Greenhouse (플라스틱온실 내부 환경 인자 다중센서 설치 위치 최적화 전략)

  • Lee, JungKyu;Kang, DongHyun;Oh, SangHoon;Lee, DongHoon
    • Journal of Bio-Environment Control
    • /
    • v.29 no.2
    • /
    • pp.161-170
    • /
    • 2020
  • There is systematic spatial variations in environmental properties due to sensitive reaction to external conditions at plastic greenhouse occupied 99.2% of domestic agricultural facilities. In order to construct 3 dimensional distribution of temperature, relative humidity, CO2 and illuminance, measurement matrix as 3 by 3 by 5 in direction of width, height and length, respectively, dividing indoor space of greenhouse was designed and tested at experimental site. Linear regression analysis was conducted to evaluate optimal estimation method in terms with horizontal and vertical variations. Even though sole measurement point for temperature and relative humidity could be feasible to assess indoor condition, multiple measurement matrix is inevitably required to improve spatial precision at certain time domain such as period of sunrise and sunset. In case with CO2, multiple measurement matrix could not successfully improve the spatial predictability during a whole experimental period. In case with illuminance, prediction performance was getting smaller after a time period of sunrise due to systematic interference such as indoor structure. Thus, multiple sensing methodology was proposed in direction of length at higher height than growing bed, which could compensate estimation error in spatial domain. Appropriate measurement matrix could be constructed considering the transition of stability in indoor environmental properties due to external variations. As a result, optimal measurement matrix should be carefully designed considering flexibility of construction relevant with the type of property, indoor structure, the purpose of crop and the period of growth. For an instance, partial cooling and heating system to save a consumption of energy supplement could be successfully accomplished by the deployment of multiple measurement matrix.

Development of a Failure Probability Model based on Operation Data of Thermal Piping Network in District Heating System (지역난방 열배관망 운영데이터 기반의 파손확률 모델 개발)

  • Kim, Hyoung Seok;Kim, Gye Beom;Kim, Lae Hyun
    • Korean Chemical Engineering Research
    • /
    • v.55 no.3
    • /
    • pp.322-331
    • /
    • 2017
  • District heating was first introduced in Korea in 1985. As the service life of the underground thermal piping network has increased for more than 30 years, the maintenance of the underground thermal pipe has become an important issue. A variety of complex technologies are required for periodic inspection and operation management for the maintenance of the aged thermal piping network. Especially, it is required to develop a model that can be used for decision making in order to derive optimal maintenance and replacement point from the economic viewpoint in the field. In this study, the analysis was carried out based on the repair history and accident data at the operation of the thermal pipe network of five districts in the Korea District Heating Corporation. A failure probability model was developed by introducing statistical techniques of qualitative analysis and binomial logistic regression analysis. As a result of qualitative analysis of maintenance history and accident data, the most important cause of pipeline damage was construction erosion, corrosion of pipe and bad material accounted for about 82%. In the statistical model analysis, by setting the separation point of the classification to 0.25, the accuracy of the thermal pipe breakage and non-breakage classification improved to 73.5%. In order to establish the failure probability model, the fitness of the model was verified through the Hosmer and Lemeshow test, the independent test of the independent variables, and the Chi-Square test of the model. According to the results of analysis of the risk of thermal pipe network damage, the highest probability of failure was analyzed as the thermal pipeline constructed by the F construction company in the reducer pipe of less than 250mm, which is more than 10 years on the Seoul area motorway in winter. The results of this study can be used to prioritize maintenance, preventive inspection, and replacement of thermal piping systems. In addition, it will be possible to reduce the frequency of thermal pipeline damage and to use it more aggressively to manage thermal piping network by establishing and coping with accident prevention plan in advance such as inspection and maintenance.

Consideration of the Structural Response of High Speed Aluminum Planning Boat Stiffened Plate Member subjected to the Simplified Equivalent Dynamic Design Pressure (동하중 등가 설계압을 받는 고속 경구조선 알루미늄 보강판부재의 구조응답 고찰)

  • HAM JUH-HYEOK;KANG BYUNG-YOON;CHOO KYUNG-HOON
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.408-413
    • /
    • 2004
  • High speed planning boats also have been required more and more the rational strength analysis and evaluation for the optimal structural design in respect of the structural lightness according to the high speed trend. Even though the suggestion of the simple type equation for the equivalent dynamic pressure is reasonable to design the scantling of ship structure conveniently, many research activities for more reasonable improvement of the simple design pressure, have been continued to suggest the more accurate equivalent static description of tire structural response such as the deflection and stress of hull structure. In this research, we focus on the aluminum bottom stiffened plate structure in which structural scantling is mainly depend on the local loads such as dynamic or impact pressure without other load effects and structural response for the simple dynamic equivalent pressure was investigated through the structural analysis. In order to investigate the structural response of the bottom stiffened plate structure subjected to the dynamic equivalent design pressure, linear and nonlinear structural analysis of the bottom stiffened plate structure of 4.3 ton aluminum planning boat was performed based on the equivalent static applied loads which were derived from the KR regulation and representative one among various dynamic equivalent pressure equations. From above analysis results, we found that the response such as deflection and stress of plate member was similar with the response results of one plate member model with fixed boundary, which was published previous paper and in case of KR design loading, all response of stiffened plate structure were within elastic limit. Through the nonlinear analysis, nearly elastic behavior including the slight geometrical nonlinear response was dominant but plastic local zone was appeared at $85\%$ limit load. Therefore, we can say that through tire linear and nonlinear analysis, this stiffened plate member has no structural strength problem based on the yield criteria in case within $60\%$ limit load except the other strength point of view such as the fatigue and buckling problem.

  • PDF

An Experimental Study on the Bonding Shear Performance Evaluation of the UHPC According to an Bonding Interface Treatment of the Construction Joint (시공이음부 계면처리방법에 따른 초고성능 콘크리트의 전단부착성능 평가에 관한 실험적 연구)

  • Jang, Hyun-O;Kim, Bo-Seok;Lee, Han-Seung
    • Journal of the Korea Institute of Building Construction
    • /
    • v.16 no.3
    • /
    • pp.237-245
    • /
    • 2016
  • Structural performance and durability of ultra high performance concrete could demonstrate optimal performance when unity was kept. Accordingly, it is necessary to involve the characteristics and quantitative surface treatment at the same time in order to retain oneness of Ultra-High-Performance Concrete(UHPC) according to construction joint occurrence. Therefore, this study derives a reasonable surface treatment method in a material's point of view through the shear adhesion performance evaluation according to the construction joints surface processing method as a part for securing the adhesion performance of the construction joints when casting UHPC. 180 MPa of required average strength was used for mix of UHPC and surface treatment method was set to totally 7 level that MN, GR-10-0, GR-20-0, GR-30-0, SH-30-5, SH-30-10. After the specimen were manufactured to a size of $150{\times}150{\times}150mm$, Direct shear test was performed to evaluate the shear adhesion strength. As a result, it was confirmed that the adhesion performance was improved when executing a surface treatment for the construction joint interface and standard of failure mode of specimen was over Type C. Also, It was considered that interface of cross section and depth of concavo-convex should be concerned.

Change of Fibrinolytic and Antioxidative Activities of Codonopsis lanceolata According to Various Storage Conditions, and Heat or Salt Treatments

  • Oh Hae-Sook;Choi Moo Young;Kim Jun-Ho
    • Biomedical Science Letters
    • /
    • v.11 no.1
    • /
    • pp.63-69
    • /
    • 2005
  • We investigated the changes of fibrinolytic and antioxidative activities of wild or cultivated Codonopsis lanceolata, which were packed in woven polypropylene (WP) film or low density polyethylene (LDPE) film and stored for 0, 15, and 30 days at refrigerated $(2\~4^{\circ}C)$ or room $(l8\~20^{\circ}C)$ temperature (So we have 16 samples, and wrote them as the abbreviated words such as W-WP-RE-15, W-WP-RO-15, W-LDPE-RE-15, W-LDPE-RO-15, W-WP-RE-30, W-WP-RO-30, W-LDPE-RE-30, W-LDPE-RO-30, C-WP-RE-15, C-WP-RO-15, C-LDPE-RE-15, C-LDPE-RO-15, C-WP-RE-30, C-WP-RO-30, C-LDPE-RE-30, C-LDPE-RO-30). Fibrinolytic activity of fresh Codonopsis lanceolata cultivated in the mountain or field were 0.8 unit (plasmin unit/ml) or 7.3 units, respectively. In descending order, the activities of wild Codonopsis lanceolata stored for 15 days were as followed; LDPE-RE (0.70 unit), WP-RO (0.52 unit), WP-RE (0.45 unit), and LDPE-RO (0.30 unit). After 30 days, fibrinolytic activities of them decreased to 0.47 unit (LDPE-RE), 0.28 unit (WP-RO), 0.21 unit (WP-RE), and 0.30 unit (LDPE-RO). Considering from the point of fibrinolytic activity, the optimal storage condition of wild Codonopsis lanceolata was packing with LDPE film and storing at $4^{\circ}C$. The change of fibrinolytic activities of Codonopsis lanceolata cultivated in the field revealed the similar trend as wild samples, but the fibrinolytic activities of 30 days-stored samples were maintained better than the wild Codonopsis lanceolata. Fibinolytic activity of wild Codonopsis lancealata was increased by heating for 5 min at $100^{\circ}C$ and decreased by addition of NaCl. Antioxidative activities of Codonopsis lanceolata were also compared from the electron donating activity. Fresh Codonopsis lanceolata had about $70\%$ of electron donating activity. Independent of cultivation area, electron donating activity dropped to $19\~74\%$ (wild Codonopsis lanceolata) and $27\~59\%$ (cultivated Codonopsis lanceolata) during 15 days storage. But after 30 days storage, we obtained the unexpected results, which meant that the activities were higher activities than 15 days-stored samples or even though the fresh samples. In general, Codonopsis lanceolata could maintain antioxidative activities most strongly with LDPE film and chilled condition.

  • PDF

Comparison of Environmental Conditions and Insulation Effect between Air Inflated and Conventional Double Layer Greenhouse (공기주입 및 관행 이중피복온실의 재배환경 및 단열성능 비교)

  • Jayasekara, Shanika N.;Na, Wook H.;Owolabi, Abdulhameed B.;Lee, Jong W.;Rasheed, Adnan;Kim, Hyeon T.;Lee, Hyun W.
    • Journal of Bio-Environment Control
    • /
    • v.27 no.1
    • /
    • pp.46-53
    • /
    • 2018
  • This study was conducted to determine which greenhouse provided good environmental conditions for strawberry production, and performed better at conserving energy. Temperature, RH, VPD, $CO_2$, solar radiation, yield, and fuel consumption were the parameters analyzed. The temperatures of both greenhouses were well controlled in order to provide optimal day and night temperatures for strawberry production. The air inflated double layer greenhouse had higher RH values (more than 90% at night), which led to higher disease occurrence, in comparison to the conventional double layer greenhouse. Furthermore, the air inflated double layer greenhouse had lower VPD values than the conventional double layer greenhouse. Therefore, better RH and VPD were observed in the conventional double layer greenhouse. Higher $CO_2$ concentration was observed in the air inflated double layer greenhouse while the conventional double layer greenhouse ventilated better than the air inflated greenhouse, because of its side ventilators. Moreover, higher solar radiation in the conventional double layer greenhouse resulted in higher yield, in comparison to the air inflated double layer greenhouse. Thus, we can conclude that the conventional double layer greenhouse provided a better environment for crop growth, in comparison to the air inflated double layer greenhouse. Regarding fuel consumption, the air inflated double layer greenhouse had lower fuel consumption than the conventional double layer greenhouse. Therefore, from an energy consumption point of view, we can conclude that the air inflated double layer greenhouse performed better than the conventional double layer greenhouse.

Development of Smart Switchgear for Versatile Ventilation Garments: Optimum Diameter and Voltage Application Unit Time of One-way Shape Memory Alloy Wire for a Bi-directional Actuator (가변 통기성 의복을 위한 스마트 개폐장치 개발: 양방향 작동 액추에이터 제작을 위한 일방향 형상기억합금 와이어의 최적 직경 및 전압인가 단위시간의 도출)

  • Kim, Sanggu;Kim, Minsung;Yoo, Shinjung
    • Science of Emotion and Sensibility
    • /
    • v.21 no.2
    • /
    • pp.137-144
    • /
    • 2018
  • The study figured out the operational conditions of a two-way movement actuator made of one-way shape memory alloy (OWSMA) for versatile ventilation intelligent garments. To develop a low-power actuator that consumes energy only when a garment changes its form such as opening and closing, multiple channels of OWSMA were used, and optimum diameter of the wires was examined. For the switch device, optimum voltage application unit time was determined. Optimum diameter of OWSMA wire was determined by applying 3.7V to the pre-determined candidate diameters, which demonstrated two-way operation in previous studies. In order to evaluate the optimum voltage application time, the internal diameter of the actuator was measured while increasing and decreasing by 50 ms from the unit time of voltage application. Delay time under two-way operation of the actuator was measured to minimize interference caused by heat between channels. Power of 3.7V was applied to OWSMA for assessment of optimal time, and the whole process from heating to cooling was video-recorded with a thermal image camera to determine the point of time at which the temperature of OWSMA wire dropped below the phase transformation temperature. The results showed that $0.4{\Phi}$ was the most suitable diameter, and the optimum unit time of voltage applied to open and close the actuator was 4100ms. It was also shown that the delay time should be more than 1.8 seconds between two-way operations of the actuator.

Separations and Feature Extractions for Image Signals Using Independent Component Analysis Based on Neural Networks of Efficient Learning Rule (효율적인 학습규칙의 신경망 기반 독립성분분석을 이용한 영상신호의 분리 및 특징추출)

  • Cho, Yong-Hyun
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.13 no.2
    • /
    • pp.200-208
    • /
    • 2003
  • This paper proposes a separation and feature extraction of image signals using the independent component analysis(ICA) based on neural networks of efficient learning rule. The proposed learning rule is a hybrid fixed-point(FP) algorithm based on secant method and momentum. Secant method is applied to improve the performance by simplifying the 1st-order derivative computation for optimizing the objective function, which is to minimize the mutual informations of the independent components. The momentum is applied for high-speed convergence by restraining the oscillation in the process of converging to the optimal solution. The proposed algorithm has been applied to the composite images generated by random mixing matrix from the 10 images of $512\times512$-pixel. The simulation results show that the proposed algorithm has better performances of the separation speed and rate than those using the FP algorithm based on Newton and secant method. The proposed algorithm has been also applied to extract the features using a 3 set of 10,000 image patches from the 10 fingerprints of $256\times256$-pixel and the front and the rear paper money of $480\times225$-pixel, respectively, The simulation results show that the proposed algorithm has also better extraction speed than those using the another methods. Especially, the 160 basis vectors(features) of $16\times16$-pixel show the local features which have the characteristics of spatial frequency and oriented edges in the images.

Synthesis of C9-Alcohol through C9-Aldehyde Hydrogenation over Copper Catalysts (구리 촉매 상에서 C9-알데히드의 수소화 반응에 의한 C9-알코올 합성)

  • Park, Young-Kwon;Noh, Sang Gyun;Cho, Kyu Sang;Jeon, Jong-Ki
    • Korean Chemical Engineering Research
    • /
    • v.44 no.4
    • /
    • pp.363-368
    • /
    • 2006
  • This study selected the optimal catalyst for the process of producing $C_9$-alcohol by hydrogenating $C_9$-aldehyde, and carried out an experiment in order to establish the operating condition for maximizing the yield of $C_9$-alcohol. The BET surface area and the specific area of copper were most excellent in $CuO/ZnO/Al_2O_3$ (60:30:10 wt%) catalyst produced using acetate as a precursor of copper and $Na_2CO_3$ as a precipitant, and the catalyst also showed the highest performance in $C_9$-aldehyde hydrogenation. Using a trickle bed reactor loaded with optimized catalyst, we attained 94.1 wt% yield of $C_9$-alcohol under the condition of $175^{\circ}C$, 800 psi and $WHSV=3hr^{-1}$. According to the result of comparing with other catalysts used in the hydrogenation of aldehyde, the catalyst showed similar performance to that of Ni/kieselghur and higher than that of $Cu-Ni-Cr-Na/Al_2O_3$ and $Ni-Mo/Al_2O_3$. According to the result of examining the stability of the catalyst through a long-term catalysis test, the yield of $C_9$-alcohol decreased slowly after around 72 hours due to the increasing production of high boiling-point byproducts.

A Shared Electronic Medical Record for Lung Cancer Clinic (폐암 클리닉을 위한 공유 전자의무기록)

  • Kim, Kyu-Sik;Park, Eun-Sun;Kim, Seung-Seok;Kim, Hyung-Woo;Kim, Young-Chul;Bom, Hee-Seung;Ahn, Sung-Ja;Na, Kook-Joo;Kim, Yun-Hyeon;Kim, Yu-Il;Lim, Sung-Chul;Moon, Jai-Dong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.59 no.5
    • /
    • pp.480-486
    • /
    • 2005
  • Since the year 2000, lung cancer has become the leading cause of cancer death in South Korea as in many other parts of the world. The current multidisciplinary approach for lung cancer includes a wide range of modalities, not only surgery, radiotherapy, medical drug therapy but also pain control, as well as social and psychological support. Therefore, thoracic surgeons, radiologists, nuclear medicine specialists, anesthetists, psychologist, nurses and social workers as well as medical doctors care for lung cancer patients. Sharing a common treatment protocol and optimal communication are vital aspects of shared care both from a medical and cost-effectiveness point of view. We developed a shared electronic medical record (SEMR) for treating patients with lung cancer in a university hospital to facilitate the sharing protocols and communications between doctors involved in a lung cancer clinic. A SEMR system was developed within a order communication system(OCS) for a lung cancer clinic. The records of radiological, laboratory and pathological studies as well as the records of surgery, chemotherapy, and radiotherapy were stored and presented to all doctors who treat the same patient. Every doctor was allowed to change his/her own records. They could review other doctor s records but could not alter them. With the SEMR, it was expected that the time to complete the medical records for one patient could be reduced because it was easy to review all the data from the other doctors who share the same patient. In addition, the confidence of the doctors who share a common treatment protocol would be higher. Therefore, a shared electronic medical record is expected to improve the quality of patient care.