• 제목/요약/키워드: Optimal Model

검색결과 8,396건 처리시간 0.036초

최적 신호주기의 결정을 위한 컴퓨터 시뮤레이션 모델 (A Computer Simulation Model for the Determination of Optimal Cycle Time of Traffic Signal)

  • 권영식;박영택
    • 산업경영시스템학회지
    • /
    • 제5권6호
    • /
    • pp.63-68
    • /
    • 1982
  • We can reduce delays and number of stops in the traffic area by means of optimal design of traffic signal system. A computer simulation model to simulate and predict the traffic signal system of Jong-Ro 4-th street was developed for determination of optimal cycle time. This simulation model was developed in relation to Jong-Ro 4-th street, but this model can be applied for other places with small modification.

  • PDF

Optimal fiber volume fraction prediction of layered composite using frequency constraints- A hybrid FEM approach

  • Anil, K. Lalepalli;Panda, Subrata K.;Sharma, Nitin;Hirwani, Chetan K.;Topal, Umut
    • Computers and Concrete
    • /
    • 제25권4호
    • /
    • pp.303-310
    • /
    • 2020
  • In this research, a hybrid mathematical model is derived using the higher-order polynomial kinematic model in association with soft computing technique for the prediction of best fiber volume fractions and the minimal mass of the layered composite structure. The optimal values are predicted further by taking the frequency parameter as the constraint and the projected values utilized for the computation of the eigenvalue and deflections. The optimal mass of the total layered composite and the corresponding optimal volume fractions are evaluated using the particle swarm optimization by constraining the arbitrary frequency value as mass/volume minimization functions. The degree of accuracy of the optimal model has been proven through the comparison study with published well-known research data. Further, the predicted values of volume fractions are incurred for the evaluation of the eigenvalue and the deflection data of the composite structure. To obtain the structural responses i.e. vibrational frequency and the central deflections the proposed higher-order polynomial FE model adopted. Finally, a series of numerical experimentations are carried out using the optimal fibre volume fraction for the prediction of the optimal frequencies and deflections including associated structural parameter.

ARIMA 모델을 이용한 수막재배지역 지하수위 시계열 분석 및 미래추세 예측 (Time-series Analysis and Prediction of Future Trends of Groundwater Level in Water Curtain Cultivation Areas Using the ARIMA Model)

  • 백미경;김상민
    • 한국농공학회논문집
    • /
    • 제65권2호
    • /
    • pp.1-11
    • /
    • 2023
  • This study analyzed the impact of greenhouse cultivation area and groundwater level changes due to the water curtain cultivation in the greenhouse complexes. The groundwater observation data in the Miryang study area were used and classified into greenhouse and field cultivation areas to compare the groundwater impact of water curtain cultivation in the greenhouse complex. We identified the characteristics of the groundwater time series data by the terrain of the study area and selected the optimal model through time series analysis. We analyzed the time series data for each terrain's two representative groundwater observation wells. The Seasonal ARIMA model was chosen as the optimal model for riverside well, and for plain and mountain well, the ARIMA model and Seasonal ARIMA model were selected as the optimal model. A suitable prediction model is not limited to one model due to a change in a groundwater level fluctuation pattern caused by a surrounding environment change but may change over time. Therefore, it is necessary to periodically check and revise the optimal model rather than continuously applying one selected ARIMA model. Groundwater forecasting results through time series analysis can be used for sustainable groundwater resource management.

강우특성별 최적 우수관망에서의 유출 변화 분석 (Analysis of flow change in optimal sewer networks for rainfall characteristics)

  • 이정호
    • 한국산학기술학회논문지
    • /
    • 제12권4호
    • /
    • pp.1976-1981
    • /
    • 2011
  • 본 연구에서는 도시유역 우수관거 시스템의 근본적인 목적인 내수침수 방재 효과를 최대화하기 위하여 첨두유출량 최소화를 목적으로 하여 개발된 우수관망 최적설계 모형(이정호, 2010)[1]을 이용하여 실제 도시유역에 대하여 다양한 인공적인 강우 사상들을 적용하여 실제 강우 발생 시 첨두유출량 저감의 효과가 발생할 수 있을 것인가에 대하여 분석하였다. 분석에 적용된 강우사상은 첫째, 설계빈도에 해당하는 강우사상에 대하여 강우의 첨두치가 일정한 시간 간격을 두고 연속되어 발생하는 강우사상들에 대하여 모의하였다. 둘째, 일정한 강도의 강우가 연속적으로 발생하는 연속강우사상에 대하여 모의하였다. 분석 결과 강우의 첨두치가 연속되는 경우 또는 일정한 강도의 연속강우에 대해서도 최적 우수관망에서 첨두유출량이 저감되는 것으로 분석되었으며, 이것은 최적화된 우수관망이 시스템 내의 지체 현상에 따른 첨두유출량 감소가 아닌 관망 전체에서의 유입량의 적정 분배에 따른 것임을 나타낸다.

다수원 상수도시스템 연계운영을 위한 최적 네트워크 모형 구축 (Development of Optimal Network Model for Conjunctive Operation of Water Supply System with Multiple Sources)

  • 유태상;하성룡;정태성
    • 한국수자원학회논문집
    • /
    • 제44권12호
    • /
    • pp.1001-1013
    • /
    • 2011
  • 이웃한 상수도시스템의 공급 가능지역이 중첩될 경우, 이들 시스템을 연계함으로써 경제성과 수질 조건을 만족시키는 조건별 용수공급체계를 구축하는 것이 필요하다. 용수수요 조건별 경제적 급수구역과 최적 펌프운영율을 산정하기 위하여 관망수리해석 모형(EPAnet)과 네트워크 최적화모형(KModSim)을 연계 하는 최적 네트워크모형을 개발하였다. 개발된 최적 네트워크 모형을 사등가압장, 구천댐 그리고 연초댐의 3개 상수원이 존재하는 거제지역 상수도시스템에 적용하고 2007년 운영 결과와 비교하는 방법으로 모형을 검정하였다. 최적 네트워크 모형의 적용성을 검토하기 위하여, 2011년 용수자료를 이용하여경제적급수구역변경에따른펌프운영및 수질의 적정성을평가 하였다. 평가결과본 모형은 수량, 경제성 그리고 수질을 모두 만족하는 최적해를 구하는 것으로 나타나 송배수계통간의 최적 설계 혹은 최적연계운영율을 구하기 위한 모형으로 활용이 가능하다.

주파수 응답함수를 이용한 구조물 고유진동수 극대화를 위한 최적 지지점 선정 (Selection of Optimal Supporting Position to Maximize Natural Frequency of the Structure Using Frequency Response Function)

  • 박용화;정완섭;박윤식
    • 소음진동
    • /
    • 제10권4호
    • /
    • pp.648-654
    • /
    • 2000
  • A procedure to determine the realizable optimal positions of rigid supports is suggested to get a maximum fundamental natural frequency. a measured frequency response function based substructure-coupling technique is used to model the supported structure. The optimization procedure carries out the eigenvalue sensitivity analysis with respect to the stiffness of supports. As a result of such stiffness optimization, the optimal rigid-support positions are shown to be determined by choosing the position of the largest stiffness. The optimally determined support conditions are verified to satisfy the eigenvalue limit theorem. To demonstrate the effectiveness of the proposed method, the optimal support positions of a plate model are investigated. Experimental results indicate that the proposed method can effectively find out the optimal support conditions of the structure just based on the measured frequency response functions without any use of numerical model of the structure.

  • PDF

ATM망의 체증을 해결하기 위한 최적 제어기 설계 (Design of Optimal Controller for the Congestion in ATM Networks)

  • 정우채;김영중;임묘택
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제54권6호
    • /
    • pp.359-365
    • /
    • 2005
  • This paper presents an reduced-order near-optimal controller for the congestion control of Available Bit Rate (ABR) service in Asynchronous Transfer Mode (ATM) networks. We introduce the model, of a class of ABR traffic, that can be controlled using a Explicit Rate feedback for congestion control in ATM networks. Since there are great computational complexities in the class of optimal control problem for the ABR model, the near-optimal controller via reduced-order technique is applied to this model. It is implemented by the help of weakly coupling and singular perturbation theory, and we use bilinear transformation because of its computational convenience. Since the bilinear transformation can convert discrete Riccati equation into continuous Riccati equation, the design problems of optimal congestion control can be reduced. Using weakly coupling and singular perturbation theory, the computation time of Riccati equations can be saved, moreover the real-time congestion control for ATM networks can be possible.

Optimal Excitation Angles of a Switched Reluctance Generator for Maximum Output Power

  • Thongprasri, Pairote;Kittiratsatcha, Supat
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권5호
    • /
    • pp.1527-1536
    • /
    • 2014
  • This paper investigates the optimal values of turn-on and turn-off angles, and ratio of flux linkage at turn-off angle and peak phase current positions of optimal control for accomplishing maximum output power in an 8/6 Switched Reluctance Generator (8/6 SRG). Phase current waveform is analyzed to determine optimal excitation angles (optimal turn-on and turn-off angles) of the SRG for maximum output power which is applied from a nonlinear magnetization curve in terms of control variables (dc bus voltage, shaft speed, and excitation angles). The optimal excitation angles in single pulse mode of operation are proposed via the analytical model. Simulated and experimental results have verified the accuracy of the analytical model.

상수관로의 노후도 예측에 근거한 최적 개량 모형의 개발 (II) - 적용 및 분석 - (Development of Optimal Rehabilitation Model for Water Distribution System Based on Prediction of Pipe Deterioration (II) - Application and Analysis -)

  • 김응석;박무종;김중훈
    • 한국수자원학회논문집
    • /
    • 제36권1호
    • /
    • pp.61-74
    • /
    • 2003
  • 본 연구(II)는 연구(I)에서 제안한 상수관로의 노후도 예측에 근거한 최적 개량 모형을 A시를 대상으로 이를 적용하였다. 노후도 예측 모형은 굴착 및 실험이 필요한 14개 항목과 굴착 및 실험이 필요하지 않은 9개 항목을 구분하여 각각 관의 노후도 등급을 산정하였다. 노후도 예측 모형 적용 결과 항목개수에 따른 등급의 차는 l~2% 이내로 굴착 및 실험을 하지 않고도 노후도 예측이 가능한 것으로 나타났다. 최적 개량 모형은 노후도 항목별 최대 잔존수명과 제약조건 유무로 구분하여 적용하였다. 적용결과 항목별 최대 잔존수명의 증가에 따라 개량 시기 및 비용이 증가하였다. 또한 예산제약을 제외한 모형과 비교해서 예산제약을 고려한 모형이 모든 항목에서 비용이 증가되었다. 이는 예산제약을 고려할 경우 실제 주어진 최대 잔존수명 기간이내 매년 발생하는 예산의 최대 금액을 넘지 않은 대신에 매년 비슷한 비용으로 개량을 실시하기 때문인 것으로 판단되었다.

하수처리장 운영의 최적화를 위한 ASM, PHOENICS의 적용 (Application of ASM and PHOENICS for Optimal Operation of Wastewater Treatment Plant)

  • 김준현;한미덕;한영한
    • 산업기술연구
    • /
    • 제20권A호
    • /
    • pp.73-82
    • /
    • 2000
  • This study was implemented to find an optimal model for wastewater treatment processes using PHOENICS(Parabolic, hyperbolic or Elliptic Numerical Integration Code Series) and ASM(Activated Sludge Model). PHOENICS is a general software based upon the laws of physics and chemistry which govern the motion of fluids, the stresses and strains in solids, heat flow, diffusion, and chemical reaction. The wastewater flow and removal efficiency of particle in two phase system of a grit chamber in wastewater treatment plant were analyzed to inquire the predictive aspect of the operational model. ASM was developed for a biokinetic model based upon material balance in complex activated sludge systems, which can demonstrate dynamic and spatial behavior of biological treatment system. This model was applied to aeration tank and settling chamber in Choonchun city, and the modeling result shows dynamic transport in aeration tank. PHOENCS and ASM could be contributed for the optimal operation of wastewater treatment plant.

  • PDF