• 제목/요약/키워드: Optimal Dose

검색결과 572건 처리시간 0.028초

체적조절호형방사선치료 시 갠트리 회전과 다엽콜리메이터의 이동 속도에 따른 선량분포 평가 (The Effect of MLC Leaf Motion Constraints on Plan Quality and Delivery Accuracy in VMAT)

  • 김연래;정진범;이정우;신영주;강동진;정재용
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제42권3호
    • /
    • pp.217-222
    • /
    • 2019
  • The purpose of this study is to evaluate the dose distribution by gantry rotation and MLC moving speed on treatment planning system(TPS) and linear accelerator. The dose analyzer phantom(Delta 4) was scanned by CT simulator for treatment planning. The planning target volumes(PTVs) of prostate and pancreas was prescribed 6,500 cGy, 5,000 cGy on VMAT(Volumetric Modulated Arc Therapy) by TPS while MLC speed changed. The analyzer phantom was irradiated linear accelerator using by planned parameters. Dose distribution of PTVs were evaluated by the homogeneity index, conformity index, dose volume histogram of organ at risk(rectum, bladder, spinal cord, kidney). And irradiated dose analysis were evaluated dose distribution and conformity by gamma index. The PTV dose of pancreas was 4,993 cGy during 0.1 cm/deg leaf and gantry that was the most closest prescribed dose(5,000 cGy). The dose of spinal cord, left kidney, and right kidney were accessed the lowest during 0.1 cm/deg, 1.5 cm/deg, 0.3 cm/deg. The PTV dose of prostate was 6,466 cGy during 0.1 cm/deg leaf and gantry that was the most closest prescribed dose(6,500 cGy). The dose of bladder and rectum were accessed the lowest during 0.3 cm/deg, 2.0 cm/deg. For gamma index, pancreas and prostate were analyzed the lowest error 100% at 0.8, 1.0 cm/deg and 99.6% at 0.3, 0.5 cm/deg. We should used the optimal leaf speed according to the gantry rotation if the treatment cases are performed VMAT.

Increasing injection frequency enhances the survival of injected bone marrow derived mesenchymal stem cells in a critical limb ischemia animal model

  • Kang, Woong Chol;Oh, Pyung Chun;Lee, Kyounghoon;Ahn, Taehoon;Byun, Kyunghee
    • The Korean Journal of Physiology and Pharmacology
    • /
    • 제20권6호
    • /
    • pp.657-667
    • /
    • 2016
  • Critical limb ischemia (CLI) is one of the most severe forms of peripheral artery diseases, but current treatment strategies do not guarantee complete recovery of vascular blood flow or reduce the risk of mortality. Recently, human bone marrow derived mesenchymal stem cells (MSCs) have been reported to have a paracrine influence on angiogenesis in several ischemic diseases. However, little evidence is available regarding optimal cell doses and injection frequencies. Thus, the authors undertook this study to investigate the effects of cell dose and injection frequency on cell survival and paracrine effects. MSCs were injected at $10^6$ or $10^5$ per injection (high and low doses) either once (single injection) or once in two consecutive weeks (double injection) into ischemic legs. Mice were sacrificed 4 weeks after first injection. Angiogenic effects were confirmed in vitro and in vivo, and M2 macrophage infiltration into ischemic tissues and rates of limb salvage were documented. MSCs were found to induce angiogenesis through a paracrine effect in vitro, and were found to survive in ischemic muscle for up to 4 weeks dependent on cell dose and injection frequency. In addition, double high dose and low dose of MSC injections increased vessel formation, and decreased fibrosis volumes and apoptotic cell numbers, whereas a single high dose did not. Our results showed MSCs protect against ischemic injury in a paracrine manner, and suggest that increasing injection frequency is more important than MSC dosage for the treatment CLI.

국내 흉부 X-선 검사에 따른 유효선량 계산 (Calculation of Effective Dose on Domestic Chest PA X-ray Examinations)

  • 최석윤
    • 한국방사선학회논문지
    • /
    • 제12권7호
    • /
    • pp.827-832
    • /
    • 2018
  • 대규모 데이터에 기반한 실제 사용 조건의 장기유효선량 분석 연구는 부족하다. 본 연구에서는 국내 324개 의료기관에서 사용하는 흉부 X건 검사의 노출조건에 대해 전산모사를 이용한 장기선량을 계산하고 평가하였다. 실험결과, 저에너지 파라미터 대역에서 유효선량은 0.024 mSv이고 비장, 부신, 폐 순으로 높았다. 고에너지 노출파라미터 대역에서 유효선량은 0.123 mSv이고 신장, 비장, 부신 순으로 높게 나왔다. Park의 연구에서 제안한 화질과 피폭을 고려한 최적의 조건을 사용했을 때 유효선량은 0.017 mSv 로 나타났다. 사용 에너지가 높아질수록 장기 전체의 유효선량이 높아지고 그 중 신장이 가장 크게 증가하였다. 연구결과는 흉부X선 검사 시 참고자료가 되고 환자 피폭저감에 도움을 줄 것이다.

진단참고수준 기반 두부 방사선검사의 최적 목표노출지수 설정에 관한 연구 (A Study on Establishment of the Optimal Target Exposure Index for Skull Radiography Based on Diagnostic Reference Level)

  • 박혜민;윤용수;김은혜;정회원;김정수
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제44권6호
    • /
    • pp.599-605
    • /
    • 2021
  • The International Electrotechnical Commission (IEC) 62494-1 has defined the exposure index (EI) that have a proportional relationship with the dose incident on the image receptor, and target exposure index (EIT), deviation index (DI). In this study, an appropriate EIT for skull radiography was established through the diagnostic reference level (DRL) and changes in DI were confirmed. Entrance surface dose (ESD) and EI were obtained using the computed radiography system displayed the EI as per IEC on console and skull phantom by experiment based on the national average exposure conditions announced in 2012 and 2019. And appropriate EIT was established by applying the DRL in 2012 and 2019. As a results, the EIT is changed according to the change in the DRL, and the exposure condition that becomes the ideal DI according to the change in the EIT also has a difference of about 1.41 times. DRL is recommended to optimize the patient dose, however it is difficult to measure in real time at medical institutions whereas EI and DI are displayed on the console at the same time as exposure. When the EIT is set based on the DRL and the DI is closed to an ideal value, it is useful as a patient dose management tool. Therefore, when the EIT is periodically managed along with the revision of the DRLs, the patient dose can be optimized through the EI, EIT and DI.

Feasibility Test of Flat-Type Faraday Cup for Ultrahigh-Dose-Rate Transmission Proton Beam Therapy

  • Sang-il Pak;Sungkoo Cho;Seohyeon An;Seonghoon Jeong;Dongho Shin;Youngkyung Lim;Jong Hwi Jeong;Haksoo Kim;Se Byeong Lee
    • 한국의학물리학회지:의학물리
    • /
    • 제33권4호
    • /
    • pp.108-113
    • /
    • 2022
  • Purpose: Proton therapy has been used for optimal cancer treatment by adapting its Bragg-peak characteristics. Recently, a tissue-sparing effect was introduced in ultrahigh-dose-rate (FLASH) radiation; the high-energy transmission proton beam is considered in proton FLASH therapy. In measuring high-energy/ultrahigh-dose-rate proton beam, Faraday Cup is considered as a dose-rate-independent measurement device, which has been widely studied. In this paper, the feasibility of the simply designed Faraday Cup (Poor Man's Faraday Cup, PMFC) for transmission proton FLASH therapy is investigated. Methods: In general, Faraday cups were used in the measurement of charged particles. The simply designed Faraday Cup and Advanced Markus ion chamber were used for high-energy proton beam measurement in this study. Results: The PMFC shows an acceptable performance, including accuracy in general dosimetric tests. The PMFC has a linear response to the dose and dose rate. The proton fluence was decreased with the increase of depth until the depth was near the proton beam range. Regarding secondary particles backscatter from PMFC, the effect was negligible. Conclusions: In this study, we performed an experiment to investigate the feasibility of PMFC for measuring high-energy proton beams. The PMFC can be used as a beam stopper and secondary monitoring system for transmission proton beam FLASH therapy.

생쥐 Preantral 난포의 체외배양: FSH의 종류와 농도 및 초자화 냉동보존의 영향 (In Vitro Culture of the Isolated Mouse Preantral Follicles: Effect of Different Types of FSH and Vitrification)

  • 이숙현;신창숙;정형민;고정재;차광렬;이경아
    • Clinical and Experimental Reproductive Medicine
    • /
    • 제27권4호
    • /
    • pp.387-392
    • /
    • 2000
  • Objectives: 1) To compare the efficacy of urofollitropin (Follimon) to that of recombinant human FSH (rhFSH) on the growth and maturation of mouse early preantral follicles in vitro, and 2) effect of vitrification on the growth and maturation of preantral follicles and oocytes . Methods: Isolated early preantra1 follicles (100-130 ${\mu}m$ diameter) were cultured for 12 days in 20 ${\mu}l$ ${\alpha}$-MEM media drop under the mineral oil. Follimon or rhFSH was added to the culture medium at various concentrations (0, 10, 100, and 1000 mIU/ml). Results: With Follimon, the dose of 10 mIU/ml showed the best follicle survival, growth, and MIl rate of oocyte than the other concentrations. Whereas the optimal dose of rhFSH was 100 mIU/ml. Despite the different optimal doses, the efficacy of two different FSHs on the follicle growth and maturation was similar. Isolated mouse preantral follicles were cryopreserved by vitrification and cultured in vitro for 12 days with 100 mIU/ml rhFSH. Despite the decreased follicular survival rate after thawing, the follicular growth and maturation rate of its oocyte were comparable to those of the fresh follicle. Conclusion: Results from the present study revealed that 1) the optimal doses of Follimon and rhFSH for in-vitro culture of mouse follicles are different, and 2) the frozen-thawed follicles develop normally after vitrification.

  • PDF

Fibrinolysis with Lower Dose Urokinase in Patients with Complicated Parapneumonic Effusion

  • Lee, Seul;Lee, Heock;Lee, Dong Hyun;Kang, Bo Hyoung;Roh, Mee Sook;Son, Choohee;Kim, Sung Hyun;Lee, Hyun-Kyung;Um, Soo-Jung
    • Tuberculosis and Respiratory Diseases
    • /
    • 제84권2호
    • /
    • pp.134-139
    • /
    • 2021
  • Background: Intrapleural urokinase is one of the most widely used fibrinolytic agents in the treatment of complicated parapneumonic effusion (CPPE). However, little research has been performed on the optimal urokinase dosage. The aim of this study was to evaluate the treatment efficacy of half dose urokinase compared with conventional dose urokinase. Methods: We retrospectively enrolled 92 patients with CPPE or empyema who underwent intrapleural urokinase treatment at two tertiary hospitals. Patients received antibiotics, chest tube drainage, and other treatments as part of routine care. The primary outcome was the treatment success rate in the half dose urokinase group (50,000 IU daily for maximal 6 days) and the conventional dose urokinase group (100,000 IU daily). Treatment success was defined as clinical and radiological improvements without surgical treatment or re-admission within one month. Results: Forty-four patients received half dose urokinase, whereas 48 patients were treated with conventional dose urokinase. Both groups were relatively well matched at baseline, excluding higher serum white blood cell count and higher empyema prevalence in the half dose urokinase group. The treatment success rate was not different between the two groups (p=0.048). There were no differences in the rate of in-hospital death and surgical treatment, hospitalization duration, and indwelling catheter duration. In the multivariate analysis, urokinase dose was not a predictor of treatment success. Conclusion: Half dose intrapleural urokinase is equally effective conventional dose urokinase in treating patients with CPPE or empyema.

구내 촬영용 엑스선 장치의 관전류에 따른 영상 평가 (Image Evaluation according to Tube Current of X-ray Device for Intraoral Imaging)

  • 김아연;조병두;이승재
    • 한국방사선학회논문지
    • /
    • 제17권4호
    • /
    • pp.515-521
    • /
    • 2023
  • 치과 구내 촬영 시 사용하는 관전류 및 시간에 따라 환자가 받는 피폭선량은 달라진다. 영상의 질을 위해서는 많은 양의 관전류가 필요하지만, 환자에게 부여되는 방사선량은 그만큼 높아진다. 이에 본 연구에서는 시뮬레이션을 통한 치과 구내 촬영 시 사용하는 관전류에 따른 영상의 질 평가를 통해 영상의 질을 확보하면서 환자가 받는 피폭선량은 감소시킬 수 있는 최적의 관전류 양을 산출하였다. 치과 구내 촬영의 진단참고수준 가이드라인에 제시된 평균 관전류와 시간 및 관전압을 기본 촬영 조건으로 사용하고, 관전류만 변화시켰을 때 영상을 획득한 후 기본 영상과의 영상의 질 비교·분석을 통해 최적의 관전류 양을 산출하였다. 기본 조건은 63 kV, 6 mA, 0.29 s로 하고 관전류를 0.1, 0.5, 1, 2, 3, 4, 5 mA로 변경시켜 영상을 획득하였다. 획득한 영상은 ICY 프로그램을 사용하여 6 mA의 조건으로 촬영한 영상과 구조적 유사지수를 평가하였다. 그 결과 0.5 mA의 관전류 조건에서도 6 mA의 영상과 구조적 유사지수가 높은 것으로 평가되었다. 이러한 결과를 바탕으로 치과 구내 촬영 시 6 mA가 아닌 0.5 mA로 촬영한다면 환자에게 부여되는 피폭선량을 매우 감소시킬 수 있을 것으로 판단된다.

두경부 세기견조방사선치료계획 최적화 조건에서 주요 인자들의 영향 분석 (Analysis of the major factors of influence on the conditions of the Intensity Modulated Radiation Therapy planning optimization in Head and Neck)

  • 김대섭;이우석;윤인하;백금문
    • 대한방사선치료학회지
    • /
    • 제26권1호
    • /
    • pp.11-19
    • /
    • 2014
  • 목 적 : 최적화 알고리즘에 적용되는 최적화 인자들의 영향을 고려하여, 가장 적합한 인자 값을 도출함으로써 이상적인 치료계획을 쉽게 설계할 수 있도록 하고자 한다. 대상 및 방법 : 본 연구의 세기조절방사선치료에서 선량계산 알고리즘은 PBC(Pencil Beam Convolution)이고, 최적화 알고리즘은 DVO(Dose Volume Optimizer 10.0.28)이다. 두경부 환자의 세기조절방사선치료에서 치료계획용적의 처방선량은 동시에 2.2 Gy와 2.0 Gy가 될 수 있도록 하였다. 치료계획은 6 MV, 7개의 조사야로 역선량계산방법으로 수립하였다. 최적화 알고리즘 인자는 용적선량-조건강도(Priority, Constrain), 선량부 드럼강도(Smooth)로 선정하고, 각 인자들의 변화량에 따른 치료계획의 영향을 분석하였다. 용적선량-조건강도는 기준 조건강도를 정하고, 비율은 같지만 절대 값은 다른 최적화 과정을 실시하였다. 또한 조건강도의 절대 값에 변화에 따른 치료용적과 주변 정상장기들을 평가하였다. 선량부드럼강도는 기준 조건의 단순 변화와 용적선량-조건강도와 관련시킨 변화를 치료계획에 반영시켰다. 치료계획은 처방선량지수(Conformal Index, CI), 처방선량포함지수(Paddick's Conformal Index, PCI), 선량균질지수(Homogeneity Index, HI)와 각 장기의 평균선량으로 평가하였다. 결 과 : 용적선량-조건강도의 비율을 동일하게 하고 절대 값을 변화 시켰을 때 CI값은 다르지만, PCI는 $1.299{\pm}0.006$, HI는 $1.095{\pm}0.004$, D5%/D95%는 $1.090{\pm}1.011$으로 처방선량에 대한 영향은 유사하였다. 이하선의 평균선량은 용적선량-조건강도의 절대 값이 40, 60, 70, 90으로 증가될 때, 67.4, 50.3, 51.2, 47.1 Gy로 감소하였다. 각각의 치료계획에서 선량부드럼강도를 증가시켰을 때, PCI는 $1.338{\pm}0.006$로 증가된 값을 보였다. 결 론 : 용적선량-조건강도는 절대적인 값보다 각 조건의 비율에 따라 최적화 알고리즘에 영향을 주었다. 절대 값이 다르더라도 같은 비율을 유지하면 유사한 치료계획이 수립되었다. 성공적인 치료계획을 수립하기 위해 특히 보호해야할 정상장기의 용적선량-조건강도는 치료용적의 용적선량-조건강도의 50%이상 되어야한다. 선량부드럼강도는 용적선량-조건강도에 따라 비례하여 증가하거나 감소하여야 한다. 단순히 절대 값으로 적용하면 용적선량-조건강도는 그 조건을 충분히 만족시키지 못한다.

토모테라피를 이용한 폐종양 방사선수술 계획 시 선량 분석 (Analysis on the Calculated Dose in the Lung Radiation Surgery Planning Using TomoTherpay)

  • 송주영;정재욱;윤미선;안성자;정웅기;나병식;남택근
    • 한국의학물리학회지:의학물리
    • /
    • 제22권4호
    • /
    • pp.178-183
    • /
    • 2011
  • 본 연구에서는 토모테라피를 이용한 폐종양의 방사선수술 치료계획을 수립한 후 기존의 선형가속기를 사용하였을 경우와 비교, 분석하여 선량분포 측면에서 유효성 및 타당성을 살펴보았다. 종양의 움직임이 5 mm 이하인 10명의 환자 CT 영상을 대상으로 기존의 선형가속기를 이용한 세기조절방사선수술에서와 동일한 처방선량과 동일한 조건의 중요장기 선량제한치로 토모테라피 치료계획을 수립한 후 선량분포를 비교하였다. 토모테라피를 이용한 결과에서도 기존의 선형가속기를 이용한 세기조절방사선수술과 동일하게 중요장기의 선량제한치를 충족시키면서 GTV에 처방선량을 부여할 수있음을 확인하였다. 방사선조사로 인한 폐의 정상조직합병증확률과 종양 반대편 폐의 등가균일선량 측면에서는 토모테라피가 기존 선형가속기보다 상대적으로 더 우수한 결과를 보였으나, 종양 내 치료선량 분포의 균일도에서는 기존 선형 가속기가 더 양호한 결과를 보였다. 치료 빔 전달 시간측면에서는 토모테라피가 기존 선형가속기 경우보다 2배 이상의 시간이 소요되었다. 이와 같은 본 연구의 결과 분석을 통해 폐종양 부위의 움직임이 적은 경우, 환자의 상태와 선량분포의 적합성 등을 고려한 최적의 치료계획을 세운다면 토모테라피를 사용하는 방사선 수술이 유효성 및 타당성이 있음을 확인할 수 있었다.