• Title/Summary/Keyword: Optical spectrum analyzer(OSA)

Search Result 9, Processing Time 0.019 seconds

Fiber Bragg grating sensor using a Mach-Zehnder interferometer and EDFA for EDFA for simultaneous measurement of strain and temperature. (마하젠더 간섭계와 EDFA를 이용한 온도와 스트레인을 동시에 측정하는 광섬유 브래그 격자 센서)

  • 최민호;김부균;정재훈;이병호
    • Korean Journal of Optics and Photonics
    • /
    • v.12 no.5
    • /
    • pp.371-375
    • /
    • 2001
  • We have implemented a sensor head which consists of erbium doped fiber pumped by 1480 nm LD and single fiber Bragg grating for simultaneous measurement of strain and temperature. The measurement precision and speed are improved by using Mach-Zehnder interferometer instead of optical spectrum analyzer (OSA) as a demodulator. The measurement precision of temperature measured by the amplitude variation of output signal is 0.05$^{\circ}C$ and that of strain measured by the phase variation of output signal is 0.1$\mu$strain. The measurement precision of temperature and strain are improved nearly 140 times and 700 times, respectively, compared to those using an OSA with wavelength resolution of 0.97 nm as d demodulator.

  • PDF

A Study on the Measurement System Design for the Resin Flow and Curing in the Vacuum Assisted Resin Transfer Molding(VARTM) Process Using the Long Period Fiber Bragg Grating (삽입된 장주기 광섬유 격자를 이용한 VARTM 공정에서의 수지이동 및 변형 과정 예측 시스템 설계에 관한 연구)

  • Yoon, Young-Ki;Chung, Seung-Hwan;Lee, Woo-Il;Lee, Byoung-Ho;Byun, Joon-Hyung
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.28 no.5
    • /
    • pp.489-494
    • /
    • 2004
  • Long Period Gratings (LPG) is currently receiving considerable attention because of their consistent measuring results fur pressure, temperature, strain and flow. LPG is easier to prepare and has a high sensitivity compared with Fiber Bragg Gratings (FBG). In addition, this kind of optical fiber sensors could be used for implementations in various structures. In this paper, LPG was used to monitor in situ the resin flow and the curing process in VARTM (Vacuum Assisted Resin Transfer. Molding). In order to demonstrate the effectiveness of the method, FBG is inserted into the glass mat to monitor the resin flow using optical spectrum analyzer (OSA). The curing reactions in VARTM are also observed using the same method. From the results, the attenuation wavelength shift and the loss change of attenuation band can be obtained from the status of the RTM (Resin Transfer Molding) sample owing to the internal variations of the .effective index, temperature, and pressure. It is shown that the proposed LPG is more effective in monitoring the curing reaction than FBG.

Effect of Soaking Temperature on Erbium Doping of Optical Fiber Core in MVCD Solution Doping Process

  • Han, Won-Taek;Kim, Yune-Hyoun;Paek, Un-Chul
    • Journal of the Optical Society of Korea
    • /
    • v.7 no.2
    • /
    • pp.47-52
    • /
    • 2003
  • Effect of soaking temperature on erbium doping of the optical fiber core during solution doping procedure, especially in the modified chemical vapor deposition (MCVD) process, was investigated. The concentration of dopants such as $Er^{3+} and Al^{3+}$ in the preforms and the optical fibers measured by the electron probe microanalysis (EPMA) and the optical spectrum analyzer (OSA) was found to increase with decreasing the soaking temperature. The increase in the concentration of the $Er^{3+}$ is attributed to the precipitation of the erbium due to the decrease in the solubility as well as the increase of capillary force and viscosity of the doping solution by decreasing the temperature.

Measurement of linear dispersion of optical fibers in zero-dispersion wavelength region (분산천이 광섬유의 영분산 파장영역에서 선형분산 곡선측정)

  • 김동환;김상혁;조재철;최상삼
    • Korean Journal of Optics and Photonics
    • /
    • v.9 no.1
    • /
    • pp.20-24
    • /
    • 1998
  • Fiber four-wave mixing(FWM) in zero-dispersion wavelength region is studied. FWM efficiency of -26 dBm and bandwidth of 2nm are measured. The linear dispersion slope in zero-dispersion wavelength region is calculated from the modulation behavior of FWM efficiency.

  • PDF

A Simple Optical Signal to Noise Ratio Monitoring Technique for OADM (광섬유 브래그 격자를 이용한 광 분기 결합기의 광신호 대 잡음비 측정방법)

  • Youn, Ji-Wook;Park, Heuk;Kim, Kwang-Joon
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.39 no.10
    • /
    • pp.43-47
    • /
    • 2002
  • A simple optical signal to noise ratio monitoring method using fiber Bragg grating is proposed for monitoring performance of OADM. OSNR of each channel is determined by monitoring the optical power transmitted and reflected from fiber Bragg gratings, simultaneously. We have obtained OSNR with accuracy better than 0.8㏈ compared with OSA of 0.1nm optical resolution in the wide input power range between -6 ㏈m and -23㏈m per channel.

Measurement of Hysteresis in PZT-Type Tunable Filters Utilizing OFDR (OFDR을 이용한 PZT형 파장가변 필터의 이력 측정)

  • Park, Do-Hyun;Yeh, Yun-Hae
    • Korean Journal of Optics and Photonics
    • /
    • v.19 no.1
    • /
    • pp.36-42
    • /
    • 2008
  • Implementation of a wavelength-swept source with constant tuning rate adopting a PZT-type tunable filter, requires the knowledge of hysteresis of the filter used. The hysteresis must be considered to avoid any degradation in resolution of the optical frequency domain reflectometry (OFDR) system. An optical spectrum analyzer (OSA) could be used to do the hysteresis measurement, but its measurement time is too long for the high-speed driving conditions for the filter. We proposed a new hysteresis measurement method based on OFDR, which could measure the hysteresis in a real driving condition. A hysteresis measurement apparatus consisted of wavelength-swept source, interferometer, signal processing unit, and PC program is built and used to do the measurement. It is concluded that the new method is useful in the measurement of hysteresis at real driving conditions by successfully implementing a swept-wavelength source whose wavelength change is linear in time.

Simple Spectral Calibration Method and Its Application Using an Index Array for Swept Source Optical Coherence Tomography

  • Jung, Un-Sang;Cho, Nam-Hyun;Kim, Su-Hwan;Jeong, Hyo-Sang;Kim, Jee-Hyun;Ahn, Yeh-Chan
    • Journal of the Optical Society of Korea
    • /
    • v.15 no.4
    • /
    • pp.386-393
    • /
    • 2011
  • In this study, we report an effective k-domain linearization method with a pre-calibrated indexed look-up table. The method minimizes k-domain nonlinear characteristics of a swept source optical coherence tomography (SS-OCT) system by using two arrays, a sample position shift index and an intensity compensation array. Two arrays are generated from an interference pattern acquired by connecting a Fabry-Perot interferometer (FPI) and an optical spectrum analyzer (OSA) to the system. At real time imaging, the sample position is modified by location movement and intensity compensation with two arrays for linearity of wavenumber. As a result of evaluating point spread functions (PSFs), the signal to noise ratio (SNR) is increased by 9.7 dB. When applied to infrared (IR) sensing card imaging, the SNR is increased by 1.29 dB and the contrast noise ratio (CNR) value is increased by 1.44. The time required for the linearization and intensity compensation is 30 ms for a multi thread method using a central processing unit (CPU) compared to 0.8 ms for compute unified device architecture (CUDA) processing using a graphics processing unit (GPU). We verified that our linearization method is appropriate for applying real time imaging of SS-OCT.

The polymer waveguide type SPR sensor using a multi-wavelength light source (다파장 광원을 이용한 폴리머 광도파로형 SPR 센서)

  • Park, Chang-Sub;Yeom, Se-Hyuk;Kim, Do-Eok;Kang, Byoung-Ho;Kim, Kyu-Jin;Kim, Hak-Rin;Kang, Shin-Won
    • Journal of Sensor Science and Technology
    • /
    • v.16 no.6
    • /
    • pp.401-406
    • /
    • 2007
  • In this paper, we fabricated the polymer waveguide type surface plasmon resonance (SPR) sensor using a white light source and optical spectrum analyzer (OSA). Fabricated sensor uses the principle of phase matching between evanescent wave and surface plasmon wave. According to the measuring result, the shift of resonance wavelength conducts the change of the refractive index. The proposed SPR sensor is expected to apply the integrated multichannel SPR sensor and the realtime monitoring system.

A Study on the Development of leisure boat's Hull Stress Monitoring System using AWG (광섬유센서를 이용한 레저선박의 선체구조모니터링시스템 개발에 관한 연구(I))

  • Kang, Nam-Seon;Kim, Hyen-Woo
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.17 no.3
    • /
    • pp.269-274
    • /
    • 2011
  • The purpose of hull stress monitoring system(HSMS) is to lead hull structure to be safer at lower cost. We proposed a hull stress monitoring system for leisure boats using fiber-optic bragg grating(FBG) strain sensor. Fiber optic sensors are well suited for structure monitoring system, due to their ability to withstand harsh environments, immunity to electromagnetic interference, and reduce cabling installation cost when employing wavelength multiplexing. This paper presents an overview of current research and design of hull stress monitoring system for leisure boats.