• Title/Summary/Keyword: Optical quenching

Search Result 109, Processing Time 0.036 seconds

A Theoretical and Experimental Investigation into Pair-induced Quenching in Bismuth Oxide-based Erbium-doped Fiber Amplifiers

  • Jung, Min-Wan;Shin, Jae-Hyun;Jhon, Young-Min;Lee, Ju-Han
    • Journal of the Optical Society of Korea
    • /
    • v.14 no.4
    • /
    • pp.298-304
    • /
    • 2010
  • The pair-induced quenching (PIQ) effect in a highly doped bismuth oxide-based erbium-doped fiber amplifier (EDFA) was theoretically and experimentally investigated. In the theoretical investigation, the bismuth oxide-based EDFA was modeled as a 6-level amplifier system that incorporated clustering-induced concentration quenching, cooperative up-conversion, pump excited state absorption (ESA), and signal ESA. The relative number of paired ions in a highly doped bismuth oxide EDF was estimated to be ~6.02%, determined by a comparison between the theoretical and the experimentally measured gain values. The impacts of the PIQ on the gain and the noise figure were also investigated.

Quenching Effect in an Optical Fiber Type Small Size Dosimeter Irradiated with 290 MeV·u-1 Carbon Ions

  • Hirata, Yuho;Watanabe, Kenichi;Uritani, Akira;Yamazaki, Atsushi;Koba, Yusuke;Matsufuji, Naruhiro
    • Journal of Radiation Protection and Research
    • /
    • v.41 no.3
    • /
    • pp.222-228
    • /
    • 2016
  • Background: We are developing a small size dosimeter for dose estimation in particle therapies. The developed dosimeter is an optical fiber based dosimeter mounting an radiation induced luminescence material, such as an OSL or a scintillator, at a tip. These materials generally suffer from the quenching effect under high LET particle irradiation. Materials and Methods: We fabricated two types of the small size dosimeters. They used an OSL material Eu:BaFBr and a BGO scintillator. Carbon ions were irradiated into the fabricated dosimeters at Heavy Ion Medical Accelerator in Chiba (HIMAC). The small size dosimeters were set behind the water equivalent acrylic phantom. Bragg peak was observed by changing the phantom thickness. An ion chamber was also placed near the small size dosimeters as a reference. Results and Discussion: Eu:BaFBr and BGO dosimeters showed a Bragg peak at the same thickness as the ion chamber. Under high LET particle irradiation, the response of the luminescence-based small size dosimeters deteriorated compared with that of the ion chamber due to the quenching effect. We confirmed the luminescence efficiency of Eu:BaFBr and BGO decrease with the LET. The reduction coefficient of luminescence efficiency was different between the BGO and the Eu:BaFBr. The LET can be determined from the luminescence ratio between Eu:BaFBr and BGO, and the dosimeter response can be corrected. Conclusion: We evaluated the LET dependence of the luminescence efficiency of the BGO and Eu:BaFBr as the quenching effect. We propose and discuss the correction of the quenching effect using the signal intensity ratio of the both materials. Although the correction precision is not sufficient, feasibility of the proposed correction method is proved through basic experiments.

An Optical Quenching and Efficiency of Laser for the Virtual Display System (허상 디스플레이에 적용되는 레이저 다이오드의 출력 효율과 파장 변이에 대한 연구)

  • Chi, Yongseok
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.9
    • /
    • pp.129-134
    • /
    • 2016
  • This paper studies the high frequency PWM (pulse width modulation) driving technique to increase an optical efficiency and to prevent an optical color quenching of blue laser for head up display on vehicles using digital micro mirror device (DMD) panel and yellow phosphor wheel. The proposed approach adaptively drives the current pulse width modulated signals of high optical power of blue laser to increase the lifetime and to decrease the stem temperature of laser. This method stabilizes the temperature of laser according to the driving environment and the forward current capacity. By the proposed method, the brightness of blue laser is improved by about 37% compared to the continuous waveform current driving method.

A Study on the critical cooling rate to avoid carbide precipitation in austenitic manganese steels during quenching (고망간 주강품의 열처리시 탄화물 석출방지를 위한 임계 냉각속도에 관한 연구)

  • Kim, Jeong-Tae;Kwahk, Si-Young;Choi, Jeong-Kil;Hong, Chun-Pyo
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.12 no.3
    • /
    • pp.206-214
    • /
    • 1999
  • The effect of cooling rate on carbide precipitation during quenching of austenitic manganese steel was investigated by optical microscopy, image analyzer and numerical analysis. A computer program based on the finite difference method for analyzing heat treatment processes was developed in order to evaluate cooling rates and the possibility of carbide precipitation during quenching. The area ratio of carbide precipitated in the austenite matrix was measured by the image analyzer, and used to determine the critical point of carbide precipitation. Temperature-dependent critical cooling rates at the critical points were calculated using the present simulation program, The calculated results showed a good agreement with the experimental ones.

  • PDF

Improved Circuits for Single-photon Avalanche Photodiode Detectors

  • Kim, Kyunghoon;Lee, Junan;Song, Bongsub;Burm, Jinwook
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.14 no.6
    • /
    • pp.789-796
    • /
    • 2014
  • A CMOS photo detection bias quenching circuit is developed to be used with single photon avalanche photodiodes (SPADs) operating in Geiger mode for the detection of weak optical signals. The proposed bias quenching circuits for the performance improvement reduce the circuit size as well as improve the performance of the quenching operation. They are fabricated in a $0.18-{\mu}m$ standard CMOS technology to verify the effectiveness of this technique with the chip area of only $300{\mu}m^2$, which is about 60 % of the previous reported circuit. Two types of proposed circuits with resistive and capacitive load demonstrated improved performance of reduced quenching time. With a commercial APD by HAMAMATSU, the dead time can be adjusted as small as 50 ns.

Fabrication and Characterization of an optical oxygen gas sensor formed on the planar optical waveguide prepared by ion exchang method (이온 교환법으로 제조된 평판형 광도파로의 산소광센서의 제작 및 특성평가)

  • 정채환;김재성;김원효;이병택;문종하;김진혁
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2002.07a
    • /
    • pp.178-179
    • /
    • 2002
  • 최근에 화학, 임상병리, 환경 감시 등의 분야에서 산소센서의 수요가 점차 증가하고 있다. 이러한 산소 센서 중에 가장 많이 쓰이는 방식은 산화물 전극을 사용하는 amperometric 방법이지만 이 방법들은 장기간에 걸쳐 볼 때 산화물 전극의 오염, 외부 자기장의 간섭 등의 제점 때문에 산소를 측정하는데 많은 어려움이 있다. (1) 따라서 최근에는 빛과 유기염료를 통하여 산소의 농도가 증가할수록 세기가 quenching이 되는 원리를 이용한 산소센서의 연구가 이루어졌다. (중략)

  • PDF

Optical Sensitivity of TL Glow Peaks Separated Using Computerized Glow Curve Deconvolution for RTL Quartz

  • Kim, Myung-Jin;Kim, Ki-Bum;Hong, Duk-Geun
    • Journal of Radiation Protection and Research
    • /
    • v.43 no.3
    • /
    • pp.114-119
    • /
    • 2018
  • Background: The retrospective dosimetry using RTL quartz can be improved by information for an optical sensitivity of sample connected with the equivalent dose determination. Materials and Methods: The quartz sample from a volcanic rock of Japan was used. After correcting the thermal quenching effect, RTL peaks of quartz were separated by the CGCD method cooperated with the general order kinetics. The number of overlapped glow peaks were ascertained by the $T_m-T_{stop}$ method. The optical sensitivity was examined by comparing the change of intensity on RTL glow peaks measured after exposure to light from a solar simulator with various illumination times. Results and Discussion: Seven glow peaks appeared to be overlapped on the RTL glow curve. The general order kinetics model was appropriate to separate glow peaks. After exposure to light from a solar simulator from a few minutes to 416 hr, the signals for peaks P4 and P5 decayed following the form of $f(t)=a_1e^{-{\lambda}1t}$, while the signals for peaks P6 and P7 decayed by the form of $f(t) = a_1e^{-{\lambda}1t}+a_2e^{-{\lambda}2t}+a_3e^{-{\lambda}3t}$. Conclusion: For dosimetric peaks, the times taken to reduce the RTL signal to half of its initial value were 70 sec for the peak P4, 54 s for the peak P5, 9,840 sec for the peak P6 and 26,580 sec for the peak P7, respectively. We conclude that the optical sensitivity of peaks P4, and P5 gives much higher than that of peaks P6 and P7.