• 제목/요약/키워드: Optical fiber sensing

검색결과 211건 처리시간 0.026초

Temperature Compensation of a Strain Sensing Signal from a Fiber Optic Brillouin Optical Time Domain Analysis Sensor

  • Kwon, Il-Bum;Kim, Chi-Yeop;Cho, Seok-Beom;Lee, Jung-Ju
    • Journal of the Optical Society of Korea
    • /
    • 제7권2호
    • /
    • pp.106-112
    • /
    • 2003
  • In order to do continuous health monitoring of large structures, it is necessary that the distributed sensing of strain and temperature of the structures be measured. So, we present the temperature compensation of a signal from a fiber optic BOTDA (Brillouin Optical Time Domain Analysis) sensor. A fiber optic BOTDA sensor has good performance of strain measurement. However, the signal of a fiber optic BOTDA sensor is influenced by strain and temperature. Therefore, we applied an optical fiber on the beam as follows: one part of the fiber, which is sensitive to the strain and the temperature, is bonded on the surface of the beam and another part of the fiber, which is only sensitive to the temperature, is located nearby the strain sensing fiber. Therefore, the strains can be determined from the strain sensing fiber while compensating for the temperature from the temperature sensing fiber. These measured strains were compared with the strains from electrical strain gages. After temperature compensation, it was concluded that the strains from the fiber optic BOTDA sensor had good coincidence with those values of the conventional electrical strain gages.

광섬유를 이용한 고감도 압력센서 개발 (Development of high sensitivity pressure sensor using optical fiber)

  • 이권형;조경재;김현철
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1995년도 추계학술대회 논문집
    • /
    • pp.478-481
    • /
    • 1995
  • This paper presents the system demonstrator for an optical fiber sensor system developed as a technological evaluator suitable for generic sensric sensing applications. The new type of fiber-optic sensor employed a diaphragm displacement transforms pressure into optical intensity. Form this sensing technique, we can know the variation of source intensity, the loss of a optical fiber, and the reflectivity of the diaphragm surface. Experimental results are applied to the low-pressure transducer suitable for measuring miniature pressure.

  • PDF

Sensing properties of optical fiber sensor to ultrasonic guided waves

  • Zhou, Wensong;Li, Hui;Dong, Yongkang;Wang, Anbang
    • Smart Structures and Systems
    • /
    • 제18권3호
    • /
    • pp.471-484
    • /
    • 2016
  • Optical fiber sensors have been proven that they have the potential to detect high-frequency ultrasonic signals, in structural health monitoring field which generally refers to acoustic emission signals from active structural damages and guided waves excited by ultrasonic actuators and propagating in waveguide. In this work, the sensing properties of optical fiber sensors based on Mach-Zehnder interferometer were investigated in the metal plate. Analytical formulas were conducted first to explore the parameters affecting its sensing performances. Due to the simple and definable frequency component, the Lamb wave excited by the piezoelectric wafer was employed to study the sensitivity of the proposed optical fiber sensors with respect to the frequency, rather than the acoustic emission signals. In the experiments, according to above investigations, spiral shape optical fiber sensors with different size were selected to increase their sensitivity. Lamb waves were excited by a circular piezoelectric wafer, while another piezoelectric wafer was used to compare their voltage responses. Furthermore, by changing the excitation frequency, the tuning frequency characteristic of the proposed optical fiber sensor was also investigated experimentally.

광시스템에서 maximum 신호 Sensing을 위한 Algorithm 설계 (Design of Algorithm for maximum Signal Sensing by Optical System)

  • 최도순
    • 한국정보전자통신기술학회논문지
    • /
    • 제3권4호
    • /
    • pp.70-75
    • /
    • 2010
  • 이 논문은 광케이블인 optical fiber를 통해 의료용 signal을 전송 할 때 porarization obtain fiber 에서 mono mode fiber로 교체되는 지점에 integrated optic인 wave conductor를 사용하여, optical signal intensity의 maximum를 sensing 하기 위한 Algorithm Brent을 설계하고 이를 검토하였다.

  • PDF

광강도형 광섬유센서를 이용한 피로손상 및 진동감지 (Fatigue Damage Detection and Vibration Sensing Using Intensity-Based Optical Fiber Sensors)

  • 양유창;전호찬;한경섭
    • Composites Research
    • /
    • 제13권1호
    • /
    • pp.89-97
    • /
    • 2000
  • 광섬유센서를 이용한 복합적층판의 피로손상 감지 및 진동측정, 그리고 스틸 보에 대한 충격위치 검출에 관한 연구가 수행되었다. 피로과정중의 신호는 복합재료 내에 삽입된 광섬유와 표면에 부착한 광강도형 광섬유센서, 그리고 스트레인게이지로부터 동시에 측정되었다. 진동감지 실험은 복합재료 보의 표면에 광섬유센서를 부착하여 자유진동 및 강제진동 신호를 취득하였다. 충격위치 검출에 관한 실험에서 충격위치는 충격에 의해 발생된 구조물의 진동이 두 센서에 도달하는 시간의 차를 이용하여 구할 수 있다. 광강도형 광섬유센서를 이용하여 반복 피로 신호를 잘 취득할 수 있었으며 스트레인게이지에 비하여 피로저항성이 우수함이 확인되었다. 광섬유센서는 갭센서와 동일하게 진동신호를 감지하였고 구조물에 가해진 충격위치를 비교적 정확히 검출할 수 있었다.

  • PDF

감법을 이용한 실리콘 오일 기반의 2채널 광섬유 온도 센서 (Silicon Oil-Based 2-Channel Fiber-Optic Temperature Sensor Using a Subtraction Method)

  • 이동은;유욱재;신상훈;김민건;송영범;김혜진;장경원;탁계래;이봉수
    • 센서학회지
    • /
    • 제25권5호
    • /
    • pp.344-348
    • /
    • 2016
  • We developed a 2-channel fiber-optic temperature sensor (FOTS) using a temperature sensing probe, a fiber-optic coupler, transmitting optical fiber, and an optical time domain reflectometer (OTDR). The temperature sensing probe is divided into a sensing probe and a reference probe for accurate thermometry. A sensing probe is composed of a silicon oil, a FC terminator, a brass pipe, and a singlemode optical fiber and the structure of a reference probe is identical with that of the sensing probe excluding a silicon oil. In this study, we measured the modified optical powers of the light signals reflected from the temperature sensing probe placed inside of the water with a thermal variation from 5 to $70^{\circ}C$. Although the optical power of the reference probe was constant regardless of the temperature change, the optical power of the sensing probe decreased linearly as the temperature increased. As experimental results, the FOTS using a subtraction method showed a small difference (i.e., hysteresis) in its response due to heating and cooling. The reversibility and reproducibility of the FOTS were also evaluated.

Magnetic Resonance Imaging Meets Fiber Optics: a Brief Investigation of Multimodal Studies on Fiber Optics-Based Diagnostic / Therapeutic Techniques and Magnetic Resonance Imaging

  • Choi, Jong-ryul;Oh, Sung Suk
    • Investigative Magnetic Resonance Imaging
    • /
    • 제25권4호
    • /
    • pp.218-228
    • /
    • 2021
  • Due to their high degree of freedom to transfer and acquire light, fiber optics can be used in the presence of strong magnetic fields. Hence, optical sensing and imaging based on fiber optics can be integrated with magnetic resonance imaging (MRI) diagnostic systems to acquire valuable information on biological tissues and organs based on a magnetic field. In this article, we explored the combination of MRI and optical sensing/imaging techniques by classifying them into the following topics: 1) functional near-infrared spectroscopy with functional MRI for brain studies and brain disease diagnoses, 2) integration of fiber-optic molecular imaging and optogenetic stimulation with MRI, and 3) optical therapeutic applications with an MRI guidance system. Through these investigations, we believe that a combination of MRI and optical sensing/imaging techniques can be employed as both research methods for multidisciplinary studies and clinical diagnostic/therapeutic devices.

Characterizing the strain transfer on the sensing cable-soil interface based on triaxial testing

  • Wu, Guan-Zhong;Zhang, Dan;Shan, Tai-Song;Shi, Bin;Fang, Yuan-Jiang;Ren, Kang
    • Smart Structures and Systems
    • /
    • 제30권1호
    • /
    • pp.63-74
    • /
    • 2022
  • The deformation coordination between a rock/soil mass and an optical sensing cable is an important issue for accurate deformation monitoring. A stress-controlled triaxial apparatus was retrofitted by introducing an optical fiber into the soil specimen. High spatial resolution optical frequency domain reflectometry (OFDR) was used for monitoring the strain distribution along the axial direction of the specimen. The results were compared with those measured by a displacement meter. The strain measured by the optical sensing cable has a good linear relationship with the strain calculated by the displacement meter for different confining pressures, which indicates that distributed optical fiber sensing technology is feasible for soil deformation monitoring. The performance of deformation coordination between the sensing cable and the soil during unloading is higher than that during loading based on the strain transfer coefficients. Three hypothetical strain distributions of the triaxial specimen are proposed, based on which theoretical models of the strain transfer coefficients are established. It appears that the parabolic distribution of specimen strain should be more reasonable by comparison. Nevertheless, the strain transfer coefficients obtained by the theoretical models are higher than the measured coefficients. On this basis, a strain transfer model considering slippage at the interface of the sensing cable and the soil is discussed.

A Fiber Optic Sensor for Determination of 2,4-Dichlorophenol Based on Oxygen Oxidation Catalyzed by Iron(III) Tetrasulfophthalocyanine

  • Tong, Yilin;Li, Dapeng;Huang, Jun;Zhang, Cong;Li, Kun;Ding, Liyun
    • Bulletin of the Korean Chemical Society
    • /
    • 제34권11호
    • /
    • pp.3307-3311
    • /
    • 2013
  • A new fiber optical sensor was developed for the determination of 2,4-dichlorophenol (DCP). The sensor was based on DCP oxidation by oxygen with the catalysis of iron(III) tetrasulfophthalocyanine (Fe(III)PcTs). The optical oxygen sensing film with $Ru(bpy)_3Cl_2$ as the fluorescence indicator was used to determine the consumption of oxygen in solution. A lock-in amplifier was used for detecting the lifetime of the oxygen sensing film by measuring the phase delay change of the sensor head. The different variables affecting the sensor performance were evaluated and optimized. Under the optimal conditions (i.e. pH 6.0, $25^{\circ}C$, Fe(III)PcTs concentration of 0.62 mg/mL), the linear detection range and response time of the sensor are $1.0{\times}10^{-6}-9.0{\times}10^{-6}$ mol/L and 250 s, respectively. The sensor displays high selectivity, good repeatability and stability, and can be used as an effective tool in analyzing DCP concentration in practical samples.

Remote Monitoring of Abrupt Overflowing in Common Utility Duct Using Reflective Side-Polished Optical Fiber Submersion Sensor

  • Lee, Cherl-Hee;Kim, Cheol;Kang, Shin-Won;Song, Jae-Won
    • Journal of the Optical Society of Korea
    • /
    • 제12권3호
    • /
    • pp.166-169
    • /
    • 2008
  • The submersion monitoring system based on a reflective side-polished optical fiber submersion sensor with an optical fiber mirror was shown to be an effective alarm system with remote monitoringwhen the drainage capacity of a common utility duct is exceeded due to heavy rainfall. The proposed sensor was connected to an existing installed optical fiber network at a height of 250mm in a common utility duct, and then tested under sample materials(distilled water, river water, sea water, foul water, muddy water, petroleum, edible oil) at a distance of 1km from the sensor for remote sensing. In experiments, the proposed real-time sensor system reduced maintenance cost and improved monitoring efficiency by using a reflection-type side-polished optical fiber submersion sensor efficient for remote monitoring of a common utility duct.