Fire Detection Signal Processing Method Using an Optical Fiber Linear Detector and the Development of an Optical Signal Processing Test Module (광섬유선형감지기를 이용한 화재감지 신호처리방법 및 광신호처리 시험모듈 개발에 관한 연구)

  • Kim, Si-Kuk;Lee, Young-Sin;Kim, Dong-Eun;Lim, Woo-Sub;Lee, Chun-Ha
    • Fire Science and Engineering
    • /
    • v.30 no.2
    • /
    • pp.27-34
    • /
    • 2016
  • This paper studies a fire detection system using an optical fiber linear detector which can minimize damage from a fire by the most adaptable even in poor environmental conditions such as a tunnel or utility-pipe conduit vulnerable to fire. Using a strand of optical fiber, temperature can be displayed in intervals of meters and a fire can be detected remotely from a distance of several kilometers. Thanks to its strengths such as high reliability and long life, it is widely applied in harsh environments in the overseas. Therefore demands are expected to grow greatly in Korea as well. However, all optical signal drive and analysis module except for the optical fiber linear detector, tend to rely on import. Firstly this study deduced the location and the method of processing signals measuring temperature by using the optical fiber linear detector in order to develop a technology for a domestic model of fire detection system. Secondly this study designed and manufactured the optical analysis test module, and then we checked its performance.

Optical Fiber Atmospheric Ozone Monitor (광섬유 대기오존 모니터)

  • 정완영
    • Proceedings of the IEEK Conference
    • /
    • 2002.06e
    • /
    • pp.201-204
    • /
    • 2002
  • A high accuracy ozone monitor using UV absorption method was developed for ambient ozone monitoring. The system was mainly composed of a high power pulsed xenon lamp as UV source, an optical spectrometer with a high sensitivity linear CCD array as UV detector and signal processing unit. The optical signal from the CCD array that provides unusually high response and excellent optical resolution for ozone concentration was converted to digital signal and the digital signal was displayed on screen using PC interface. The optical signal was propagated using optic fiber to reduce optical loss to increase the accuracy of the measuring system. This paper has been studied a interworking signalling protocol between two hybrid networks by analyzing Satellite B-ISDN architecture, DSS2 Layer 3 Signalling protocol, B-ISUP protocol, S-BISUP protocol stack and so on. Also in the paper, messages and primitives have been defined for B-ISDN's Connection Type, Ownership and each protocol in order to connect point-to-multipoint. The ozone sensing properties of the CCD ozone monitor was compared with those of the photo multiplier ozone monitor.

  • PDF

Opto-Mechanical Detailed Design of the G-CLEF Flexure Control Camera

  • Jae Sok Oh;Chan Park;Kang-Min Kim;Heeyoung Oh;UeeJeong Jeong;Moo-Young Chun;Young Sam Yu;Sungho Lee;Jeong-Gyun Jang;Bi-Ho Jang;Sung-Joon Park;Jihun Kim;Yunjong Kim;Andrew Szentgyorgyi;Stuart McMuldroch;William Podgorski;Ian Evans;Mark Mueller;Alan Uomoto;Jeffrey Crane;Tyson Hare
    • Journal of The Korean Astronomical Society
    • /
    • v.56 no.2
    • /
    • pp.169-185
    • /
    • 2023
  • The GMT-Consortium Large Earth Finder (G-CLEF) is the first instrument for the Giant Magellan Telescope (GMT). G-CLEF is a fiber feed, optical band echelle spectrograph that is capable of extremely precise radial velocity measurement. G-CLEF Flexure Control Camera (FCC) is included as a part in G-CLEF Front End Assembly (GCFEA), which monitors the field images focused on a fiber mirror to control the flexure and the focus errors within GCFEA. FCC consists of an optical bench on which five optical components are installed. The order of the optical train is: a collimator, neutral density filters, a focus analyzer, a reimager and a detector (Andor iKon-L 936 CCD camera). The collimator consists of a triplet lens and receives the beam reflected by a fiber mirror. The neutral density filters make it possible a broad range star brightness as a target or a guide. The focus analyzer is used to measure a focus offset. The reimager focuses the beam from the collimator onto the CCD detector focal plane. The detector module includes a linear translator and a field de-rotator. We performed thermoelastic stress analysis for lenses and their mounts to confirm the physical safety of the lens materials. We also conducted the global structure analysis for various gravitational orientations to verify the image stability requirement during the operation of the telescope and the instrument. In this article, we present the opto-mechanical detailed design of G-CLEF FCC and describe the consequence of the numerical finite element analyses for the design.

Study on the Development of Optical Sensor Linear Fire Detection System Using Raman Scattering (라만산란을 이용한 광센서 선형 화재감지시스템 개발에 관한 연구)

  • Lee, Gun-Ho;Lim, Woo-Sub;Kim, Si-Kuk
    • Fire Science and Engineering
    • /
    • v.30 no.4
    • /
    • pp.27-38
    • /
    • 2016
  • The paper reports the development of a distributed temperature sensing (DTS) system, which is a fire detection system using optical sensor linear detectors that depends on foreign and domestic technologies. This study accordingly analyzed the electrical signal patterns of Raman scattering light mainly used for temperature sensing among back-scattered light generated in optical fiber by using an oscilloscope. Through the measurement results, it could be verified that the Stokes signal patterns had little change by the temperature increase, but the temperature-sensitive anti-Stokes patterns had relative increase of the changes. This study developed a K-DTS system, which is an optical sensor linear fire detection system composed of an optical repeater and a receiver that can detect fires using Raman scattering light. It could be verified that the developed K-DTS system satisfied the type approval standards through the sensitivity tests using the rate of rise type and fixed temperature type sensitivity testers. In addition, performance experiments have been performed for performance evaluation of the K-DTS system developed in comparison with S-DTS system which has been imported from abroad and widely used in Korea. It can be confirmed from the results of the performance experiments using model tunnels that comparable performances can be obtained in fire detection locations and the measurements of fire temperatures.