• Title/Summary/Keyword: Optical data processing

Search Result 362, Processing Time 0.025 seconds

Comparative Analysis of NDWI and Soil Moisture Map Using Sentinel-1 SAR and KOMPSAT-3 Images (KOMPSAT-3와 Sentinel-1 SAR 영상을 적용한 토양 수분도와 NDWI 결과 비교 분석)

  • Lee, Jihyun;Kim, Kwangseob;Lee, Kiwon
    • Korean Journal of Remote Sensing
    • /
    • v.38 no.6_4
    • /
    • pp.1935-1943
    • /
    • 2022
  • The development and application of a high-resolution soil moisture mapping method using satellite imagery has been considered one of the major research themes in remote sensing. In this study, soil moisture mapping in the test area of Jeju Island was performed. The soil moisture was calculated with optical images using linearly adjusted Synthetic Aperture Radar (SAR) polarization images and incident angle. SAR Backscatter data, Analysis Ready Data (ARD) provided by Google Earth Engine (GEE), was used. In the soil moisture processing process, the optical image was applied to normalized difference vegetation index (NDVI) by surface reflectance of KOMPSAT-3 satellite images and the land cover map of Environmental Systems Research Institute (ESRI). When the SAR image and the optical images are fused, the reliability of the soil moisture product can be improved. To validate the soil moisture mapping product, a comparative analysis was conducted with normalized difference water index (NDWI) products by the KOMPSAT-3 image and those of the Landsat-8 satellite. As a result, it was shown that the soil moisture map and NDWI of the study area were slightly negative correlated, whereas NDWI using the KOMPSAT-3 images and the Landsat-8 satellite showed a highly correlated trend. Finally, it will be possible to produce precise soil moisture using KOMPSAT optical images and KOMPSAT SAR images without other external remotely sensed images, if the soil moisture calculation algorithm used in this study is further developed for the KOMPSAT-5 image.

Phase-based virtual image encryption and decryption system using Joint Transform Correlator

  • Seo, Dong-Hoan;Cho, Kyu-Bo;Park, Se-Joon;Cho, Woong-Ho;Noh, Duck-Soo;Kim, Soo-Joong
    • Proceedings of the IEEK Conference
    • /
    • 2002.07a
    • /
    • pp.450-453
    • /
    • 2002
  • In this paper a Phase-based virtual image encryption and decryption techniques based on a joint transform correlator (JTC) are proposed. In this method, an encrypted image is obtained by multiplying a phase-encoded virtual image that contains no information from the decrypted image with a random phase. Even if this encryption process converts a virtual image into a white-noise-like image, the unauthorized users can permit a counterfeiting of the encrypted image by analyzing the random phase mask using some phase-contrast technique. However, they cannot reconstruct the required image because the virtual image protects the original image from counterfeiting and unauthorized access. The proposed encryption technique does not suffer from strong auto-correlation terms appearing in the output plane. In addition, the reconstructed data can be directly transmitted to a digital system for real-time processing. Based on computer simulations, the proposed encryption technique and decoding system were demonstrated as adequate for optical security applications.

  • PDF

Fine Digital Sun Sensor(FDSS) Design and Analysis for STSAT-2

  • Rhee, Sung-Ho;Jang, Tae-Seong;Ryu, Chang-Wan;Nam, Myeong-Ryong;Lyou, Joon
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.1787-1790
    • /
    • 2005
  • We have developed satellite devices for fine attitude control of the Science & Technology Satellite-2 (STSAT-2) scheduled to be launched in 2007. The analog sun sensors which have been continuously developed since the 1990s are not adequate for satellites which require fine attitude control system. From the mission requirements of STSAT-2, a compact, fast and fine digital sensor was proposed. The test of the fine attitude determination for the pitch and roll axis, though the main mission of STSAT-2, will be performed by the newly developed FDSS. The FDSS use a CMOS image sensor and has an accuracy of less than 0.01degrees, an update rate of 20Hz and a weight of less than 800g. A pinhole-type aperture is substituted for the optical lens to minimize the weight while maintaining sensor accuracy by a rigorous centroid algorithm. The target process speed is obtained by utilizing the Field Programmable Gate Array (FPGA) in acquiring images from the CMOS sensor, and storing and processing the data. This paper also describes the analysis of the optical performance for the proper aperture selection and the most effective centroid algorithm.

  • PDF

Development of Hybrid Image Stabilization System for a Mobile Robot (이동 로봇을 위한 하이브리드 이미지 안정화 시스템의 개발)

  • Choi, Yun-Won;Kang, Tae-Hun;Saitov, Dilshat;Lee, Dong-Chun;Lee, Suk-Gyu
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.17 no.2
    • /
    • pp.157-163
    • /
    • 2011
  • This paper proposes a hybrid image stabilizing system which uses both optical image stabilizing system based on EKF (Extended Kalman Filter) and digital image stabilization based on SURF (Speeded Up Robust Feature). Though image information is one of the most efficient data for object recognition, it is susceptible to noise which results from internal vibration as well as external factors. The blurred image obtained by the camera mounted on a robot makes it difficult for the robot to recognize its environment. The proposed system estimates shaking angle through EKF based on the information from inclinometer and gyro sensor to stabilize the image. In addition, extracting the feature points around rotation axis using SURF which is robust to change in scale or rotation enhances processing speed by removing unnecessary operations using Hessian matrix. The experimental results using the proposed hybrid system shows its effectiveness in extended frequency range.

Theoretical analysis on the maximum volume ablation rate for copper ablation with a 515nm picosecond laser (515nm 피코초 레이저를 이용한 구리 어블레이션 공정의 최대 가공율에 대한 이론적 분석)

  • Shin, Dongsig;Cho, Yongkwon;Sohn, Hyonkee;Suh, Jeong
    • Laser Solutions
    • /
    • v.16 no.2
    • /
    • pp.1-6
    • /
    • 2013
  • Picosecond lasers are a very effective tool for micromachining metals, especially when high accuracy, high surface roughness and no heat affected zone are required. However, low productivity has been a limit to broadening the spectrum of their industrial applications. Recently it was reported that in the micromachining of copper with a 1064nm picosecond laser, there exist the optimal pulse energy and repetition rate to achieve the maximum volume ablation rate. In this paper, we used a 515nm picosecond laser, which is more efficient for micromachining copper in terms of laser energy absorption, to obtain its optimal pulse energy and repetition rate. Theoretical analysis based on the experimental data on copper ablation showed that using a 515nm picosecond laser instead of a 1064nm picosecond laser is more favorable in that the calculated threshold fluence is 75% lower and optical penetration depth is 50% deeper.

  • PDF

Improvement of Optical 3D Scanner Performance Using Atomization-Based Spray Coating

  • Valinasab, Behzad;Rukosuyev, Maxym;Lee, Jason;Ko, Junghyuk;Jun, Martin B.G.
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.24 no.1
    • /
    • pp.23-30
    • /
    • 2015
  • The scanning quality can be influenced by reflective abilities of a surface. Transparency and glossiness of a surface can highly limit the scanning results. Various techniques have been developed to solve problems of reflective and transparent surfaces. As one of the most feasible and convenient solutions, a thin layer of coating with proper specifications is sprayed on surface for eliminating the problems of the surfaces. As the main goal is to keep the object geometry unchanged, then it is important to coat the surface with layers less than one micrometer in thickness. For this purpose, a newly designed atomization-based spray system has been developed and tested in sets of experiments to study its efficiency on scanning results while objects with the surface are in use. This paper presents the spray design process and then studies and compares the 3D scanning results of the surfaces coated with atomization-based and aerosol sprays.

In-cylinder Flame Visualization and Flame Propagation Characteristics of SI Engine by using Optimal Threshold Method (Optimal Threshold 법을 이용한 가솔린 기관의 실린더 내화염 가시화 및 화염 전파 특성에 관한 연구)

  • 김진수;전문수;윤정의
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.8 no.5
    • /
    • pp.96-104
    • /
    • 2000
  • It is well known that combustion stability under idle and part-load conditions directly affect fuel economy and exhaust emission. In practice, there have been a lot of studies so that a significant improvement in combustion stability has been achieved in this research field. However, applying published results to the development process of mass production engine, there are still many problems which are solved previously. In this study, initial flame behavior and flame propagation characteristic were investigated statistically in order to optimize combustion chamber shapes in the development stage of mass production S.I. engine. To the purpose, the authors applied the flame image capturing system to single cylinder optical engine. The captured flame images were effectively analyzed by using the image processing program which was developed by the authors and adopted new threshold algorithm instead of conventional histogram analysis. In addition, the cylinder pressure was also measured simultaneously to compare evaluated flame results with cylinder pressure data in terms of the combustion characteristics, combustion stability, and cycle-to-cycle combustion variability.

  • PDF

Compensation Design to Reduce Springback in Sheet Metal Forming of 1.2GPa Ultra High Strength Steel (1.2GPa급 강판 판재 성형에서 스프링백 감소를 위한 금형 보상 설계)

  • Kwon, S.H.;Lee, H.S.;Lee, Y.S.;Kim, S.W.;Jung, C.Y.;Hong, S.
    • Transactions of Materials Processing
    • /
    • v.25 no.5
    • /
    • pp.301-305
    • /
    • 2016
  • The manual modification of stamping die has widely been used in order to reduce springback after sheet metal forming. When UHSS (Ultra High Strength Steel) is used in sheet metal forming, the die design considering springback compensation is more difficult because higher strength sheet has more springback. In this study, the optimization method was used in order to design die geometry considering springback compensation after forming of 1.2GPa UHSS. Die geometries were defined as design variables and the springback distance from the die surface was conducted as object function in optimization process. The optimized die geometry considering springback compensation was performed using finite element and optimization analysis. The simulation results such as thickness distribution and springback amount were compared with measured data using 3D optical measurement system (GOM ARGUS, ATOS). And the prediction of springback amount showed a good agreement within test results.

Validation of chlorophyll algorithm in Ulleung Basin, East/Japan Sea

  • Yoo, Sin-Jae;Kim, Hyun-Cheol;Lee, Jeong-ah;Park, Mi-Ok
    • Korean Journal of Remote Sensing
    • /
    • v.18 no.1
    • /
    • pp.35-42
    • /
    • 2002
  • The results of our observation in May 2000 indicated that the SeaWiFS algorithm (O'Reilley et al., 1998), which was adopted for OSMI data processing, overestimated the actual chlorophyll values. This was rather unexpected in that there were good reasons to expect that the bio-optical properties of East/Japan Sea belonged to Case 1 water and in such case, the OC2 algorithm would give unbiased estimates of actual chlorophyll a values. In November 2000, a cruise conducted bio-optical surveys in the same area. This time we added HPLC (High Performance Liquid Chromatography) method for measuring chlorophyll a concentration to the standard fluorometric method, which we hale been using during the past Fluorometric method with acidification is known to result in under/overestimation of chlorophyll values in many parts of the world oceans, while it is easier and cheaper than HPLC method. To our surprise, the comparison of HPLC chlorophyll and fluorometric chlorophyll values show that fluorometric values gave an underestimation up to 50%. This error was due to the presence of accessory pigments such as chlorophyll b. Considering this error, our precious result of May 2000(Yoo et al., 2000) might have to be reinterpreted. Calculation of reflectance at 490 and 555nm, however, indicated that this is not still enough to explain the discrepancies.

Characteristics of the Electro-Optical Camera(EOC)

  • Lee, Seung-Hoon;Shim, Hyung-Sik;Paik, Hong-Yul
    • Proceedings of the KSRS Conference
    • /
    • 1998.09a
    • /
    • pp.313-318
    • /
    • 1998
  • Electro-Optical Camera(EOC) is the main payload of Korea Multi-Purpose SATellite(KOMPSAT) with the mission of cartography to build up a digital map of Korean territory including Digital Terrain Elevation Map(DTEM). This instrument which comprises EOC Sensor Assembly and EOC Electronics Assembly produces the panchromatic images of 6.6 m GSD with a swath wider than 17 km by push-broom scanning and spacecraft body pointing in a visible range of wavelength, 510 ~ 730 nm. The high resolution panchromatic image is to be collected for 2 minutes during 98 minutes of orbit cycle covering about 800 km along ground track, over the mission lifetime of 3 years with the functions of programmable rain/offset and on-board image data storage. The image of 8 bit digitization, which is collected by a full reflective type F8.3 triplet without obscuration, is to be transmitted to Ground Station at a rate less than 25 Mbps. EOC was elaborated to have the performance which meets or surpasses its requirements of design phase. The spectral response the modulation transfer function, and the uniformity of all the 2592 pixel of CCD of EOC are illustrated as they were measured for the convenience of end-user. The spectral response was measured with respect to each gain setup of EOC and this is expected to give the capability of generating more accurate panchromatic image to the EOC data users. The modulation transfer function of EOC was measured as greater than 16% at Nyquist frequency over the entire field of view which exceeds its requirement of larger than 10%, The uniformity that shows the relative response of each pixel of CCD was measured at every pixel of the Focal Plane Array of EOC and is illustrated for the data processing.

  • PDF