• Title/Summary/Keyword: Optical Zoom

Search Result 127, Processing Time 0.023 seconds

DLC Coating Effect of WC Core Surface for Glass Molding Lens (비구면 Glass 렌즈 성형용 초경합금(WC) 코어의 DLC 코팅 효과)

  • Kim, Hyun-Uk;Jeong, Sang-Hwa;Park, Yong-Pil;Kim, Sang-Suk;Kim, Hye-Jeong;Kim, Jeong-Ho
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.19 no.11
    • /
    • pp.1050-1054
    • /
    • 2006
  • There have been intensive and continuous efforts in the field of DLC coating process because of their feature, like high hardness, high elasticity, abrasion resistance and chemical stability and have been applied widely the industrial areas. In this research, optimal grinding condition was investigated using Microlens Process Machine for the development of aspheric glass lens which is to be used for mobile phone module with 3 mega pixel and 2.5X optical zoom, and tungsten carbide(WC) mold cote was manufactured using high performance ultra precision machining and the effects of DLC coating on the form accuracy(PV) and surface roughness(Ra) of WC mold core was evaluated.

Design of Two Zoom Infrared Camels using Noise Uniformity Correction by Shutter Lens (셔터렌즈에 의한 검출기 불균일 보정을 적용한 이중배율 적외선 카메라 설계)

  • Ahn, Gyou-Bong;Kim, Seo-Hyun;Jung, Jae-Chul;Jo, Mun-Shin;Kim, Chang-Woo;Kim, Hyun-Sook
    • Korean Journal of Optics and Photonics
    • /
    • v.18 no.2
    • /
    • pp.135-141
    • /
    • 2007
  • This paper describes the design technology for a third generation thermal imaging system, which is more compact than before, using a $320\times240$ mid-IR focal plane detector. The third generation non-scanning thermal imaging system was constructed as a compact thermal imaging module as a reconnaissance, surveillance and navigation sensor for helicopter and infantry vehicles in the $1980's\sim1990's$ and now, we designed a new compact infrared camera and studied a new type of non-uniformity correction lens fer this camera.

On the Design of LED Dimming Control System for Optical Zoom Lens (광학 줌렌즈를 위한 LED 조명 제어 시스템 설계)

  • Min, Jun Hong;Kim, Min Ho;Yang, Oh
    • Journal of the Semiconductor & Display Technology
    • /
    • v.13 no.4
    • /
    • pp.65-70
    • /
    • 2014
  • This paper is to improve the problem of the LED dimming control system using the conventional PWM and DAC method. The conventional PWM method controls the average current to switch dimming signal. This method generates the flicker when controlling at a low current. In order to solve the problem, this system prevents the flicker with the DAC method. The LED is lit at micro-current flowing in the LED. And offset voltage is generated in the output of the DAC when the DAC output is very low voltage as 0V. This was resolved by the voltage drop of the output voltage to construct a negative offset circuit. In addition, the LED current can't flow as set values because of overheating of FET. In order to solve the problem, the 16 bits ADC in the microprocessor is a more accurate current control receives the LED current in comparison with the set value. Therefore, the LED dimming control system proposed in this paper showed the accurate and reliable more than conventional systems.

The Electro-Mechanical Properties of Disk-Type Stator for Ultrasonic Motor (초음파 모터용 디스크형 고정자의 전기기계적 특성)

  • Lee, J.S.;Kim, B.W.;Lee, S.H.;Shin, S.I.;Nam, K.D.;Oh, H.K.;Jang, Y.J.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.339-340
    • /
    • 2006
  • In this paper, disk-type ultrasonic motor using radial and bending vibration modes is newly designed and fabricated to measure its characteristics. As the diameter of elastic body increases, the resonant frequency decreases and its resonant frequency is about 92kHz when the physical dimensions of piezoelectric ceramic and elastic body are 28mm of diameter and 2mm of thickness, and 32mm of diameter and 2mm of thickness, respectively. When the applied voltage is 20Vpp. its speed and torque are 200rpm and 1N, respectively.

  • PDF

Statistical Analysis of Focus Adjustment Method for a Floating Imaging System with Symmetric Error Factors (대칭형 공차를 갖는 플로팅 광학계의 상면 변화 보정 방법에 대한 통계적 해석)

  • Ryu, Jae Myung;Kim, Yong Su;Jo, Jae Heung;Kang, Geon Mo;Lee, Hae Jin;Lee, Hyuck Ki
    • Korean Journal of Optics and Photonics
    • /
    • v.23 no.5
    • /
    • pp.189-196
    • /
    • 2012
  • A floating optical system is a system that moves more than 2 groups to focus at the camera lens. At the camera optics, the floating system that is mainly used is an optical system such as a macro lens which changes magnification very much. When the floating system is assembled and fabricated in the factory, there are differences between the image plane of the sensor and the focal plane of the infinity or macro state. Therefore, in a considerable proportion of cases, the focus adjustment to minimize the difference of BWD(Back Working Distance) is carried out in the process of manufacturing. In this paper, in order to decide the movement of each group in a floating system, we evaluated the rotation angle of CAM for the focus adjustment. We know that the maximum magnification of macro state is corrected by this numerical method for the focus adjustment, too. We investigated the limit of CAM rotation angle of the system by using statistical analysis for CAM rotation angle, which uses the focus adjustment of the floating system with symmetric error factors.

A Study on The Tracking and Analysis of Moving Object in MPEG Compressed domain (MPEG 압축 영역에서의 움직이는 객체 추적 및 해석)

  • 문수정;이준환;박동선
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2001.11b
    • /
    • pp.103-106
    • /
    • 2001
  • 본 논문에서는 MPEG2비디오 스트림에서 직접 얻을 수 있는 정보들을 활용하여 카메라의 움직임을 추정하여 이를 기반으로 하여 움직이는 객체를 추정하고자 한다. 이를 위해, 먼저 MPEG2의 움직임 벡터는 압축의 효율성 때문에 움직임의 예측이 순서적이지 못한데, 예측 프레임들의 속성을 이용하여 이를 광 플로우(Optical Flow)를 갖는 움직임 벡터(Motion Vector)로 변환하였다. 그리고 이러한 벡터들을 이용하여 카메라의 기본적인 움직임인 팬(Fan), 틸트(Tilt). 줌(Zoom) 등을 정의하였다. 이를 위하여 팬, 틸트-줌 카메라 모델의 매개변수와 같은 의미의 $\Delta$x, $\Delta$y, $\alpha$값을 정의하고자 움직임 벡터 성분의 Hough변환을 이용하여 $\Delta$x, $\Delta$y, $\alpha$값들을 구하였다. 또한 이러한 카메라 움직임(Camera Operation)은 시간적으로 연속적으로 발생하는 특징을 이용하여 각 프레임마다 구한 카메라의 움직임을 보정하였다. 마지막으로 움직이는 객체의 추정은 우선 사용자가 원하는 객체를 바운딩박스 형태로 정의한 후 카메라 움직임이 보정된 객체의 움직임 벡터를 한 GOF(Group of Pictures) 단위로 면적 기여도에 따라 누적하여 객체를 추적하고 해석하였으며 DCT 질감 정보를 이용하여 객체의 영역을 재설정 하였다. 물론 압축된 MFEG2비디오에서 얻을 수 있는 정보들은 최대 블록 단위이므로 객체의 정의도 블록단위 이상의 객체로 제한하였다. 제안된 방법은 비디오 스트림에서 직접 정보를 얻음으로써 계산속도의 향상은 물론 카메라의 움직임특성과 움직이는 객체의 추적들을 활용하여 기존의 내용기반의 검색 및 분석에도 많이 응용될 수 있다. 이러한 개발 기술들은 압축된 데이터의 검색 및 분석에 유용하게 사용되리라고 기대되며 , 특히 검색 툴이나 비디오 편집 툴 또는 교통량 감시 시스템, 혹은 무인 감시시스템 등에서 압축된 영상의 저장과 빠른 분석을 요구시 필요하리라고 기대된다.

  • PDF

Changes in the Titer of Tooth Root Antibodies Accompanying Root Resorption Associated with Orthodontic Tooth Movement (치아이동시 치근 흡수에 따른 치근항체의 역가 변화)

  • Park, Soo-Byung;Son, Woo-Sung
    • The korean journal of orthodontics
    • /
    • v.24 no.2
    • /
    • pp.303-317
    • /
    • 1994
  • This study was designed to measure the changes in the titer of tooth root antibodies accompanying root resorption associated with orthodontic tooth movement in dogs to explore a role of the specific immune response in root resorption during orthodontic tooth movement. Five adult mongrel dogs, 2 years of age, were used in the study. Six lower incisors were extracted as sources of homologous antigen in the dogs. Tooth root antigen preparations were made from a 6M Guanidine-HCl-10% EDTA(pH5.0) extract of these root dentins. Root resorption was elicited by intrusion of six maxillary incisors with 200-250gm intrusive force. In 9th week, resorbing six maxillary anterior teeth were extracted. Serum samples were taken from each dog prior to intrusion and weekly for 11 consecutive weeks. Serum autoantibody titers were determined with an enzyme-linked immunosorbent assay. As controls for antibody specificity, sera which were previously incubated with tooth root antigen as well as sera to an unrelated bacterial antigen (Porphyromonas gingivalis 33277) for 3 hours at 25 were measured in all runs. Root resorption was monitored monthly using occlusal radiographs. And then root resorption patterns were observed with a zoom stereo microscope (Model SZH-121, Olympus optical Co. Ltd.). Incisors did not show clear radiographic evidence of significant and progressive root resorption, but periodontal ligament space had widened. But root resorption was observed on the apical regions of the maxillary incisors with a zoom stereo microscope. Teeth showed the shallow depression generally accompanying deep resorption. These demonstrate a slight tendency for an immediate decrease followed by rebound to levels above the pre-treatment baseline. A peak titer of autoantibody to dentin antigen occurred on day 28, then steadily decreased during the 9th week period as the roots resorbed and then rapidly spiked in animals when the resorbing teeth were extracted. When sera is incubated with tooth root antigen, serum activity in the ELISA was almost absent. This is because serum activity in the ELISA could be removed by absorption of the serum with dog dentin antigen. Serum ELISA activity to the unrelated bacterial antigen remained essentially unchanged in all animals throughout the experimental period. When the time course of changes in autoantibody to homologous tooth root antigen prepatration and unrelated bacterial antigen was compared, no significant differences were found(${\alpha}=0.05$). In general, the overall pattern of changes in autoantibody was similar to the two antigens. These findings suggest the possibility that these immunologic changes precede a significant development of root resorption lesions rather than merely reflecting their presence. Therefore, this suggests that the changes of antibody levels may have some predictive value for root resorption.

  • PDF