• 제목/요약/키워드: Optical Signal Processing

검색결과 326건 처리시간 0.021초

Background-noise Reduction for Fourier Ptychographic Microscopy Based on an Improved Thresholding Method

  • Hou, Lexin;Wang, Hexin;Wang, Junhua;Xu, Min
    • Current Optics and Photonics
    • /
    • 제2권2호
    • /
    • pp.165-171
    • /
    • 2018
  • Fourier ptychographic microscopy (FPM) is a recently proposed computational imaging method that achieves both high resolution (HR) and wide field of view. In the FPM framework, a series of low-resolution (LR) images at different illumination angles is used for high-resolution image reconstruction. On the basis of previous research, image noise can significantly degrade the FPM reconstruction result. Since the captured LR images contain a lot of dark-field images with low signal-to-noise ratio, it is very important to apply a noise-reduction process to the FPM raw dataset. However, the thresholding method commonly used for the FPM data preprocessing cannot separate signals from background noise effectively. In this work, we propose an improved thresholding method that provides a reliable background-noise threshold for noise reduction. Experimental results show that the proposed method is more efficient and robust than the conventional thresholding method.

Cascaded Volume Holographic Gratings for expanding the Channel Number of a Optical Demultiplexer

  • Lee, Kwon-Yeon;Jeung, Sang-Huek;Do, Duc-Dung;An, Jun-Won;Kim, Nam
    • 융합신호처리학회논문지
    • /
    • 제8권2호
    • /
    • pp.84-90
    • /
    • 2007
  • 캐스케이드 홀로그래픽 부피격자를 이용한 130채널 광 역다중화기를 제안하고 실험적으로 입증하였다. 첫 번째 격자와는 서로 다른 격자주기, 경사각, 중심파장 등은 갖는 두 번째 홀로그래픽 격자를 첫 번째 격자에 직렬로 부가함으로써 역 다중화기의 동작파장범위를 늘릴 수 있으며, 결국 홀로그래픽 역다중화기의 채널수는 두 배 증가하게 된다. 본 논문에서는 채널 균일도가 3.5dB, 3dB 대역폭이 0.12nm, 채널누화가 -20dB인 0.4nm 채널간격을 갖는 역다중화기를 실험적으로 구현하였다.

  • PDF

SLD 동조 광원을 이용한 브라그 파장 측정 LPG 센서의 신호처리 시스템 (Long-period grating sensor signal processing system by Bragg wavelength measurement using SLD tunable light source)

  • 이호준;배윤경
    • 한국광학회지
    • /
    • 제15권5호
    • /
    • pp.409-414
    • /
    • 2004
  • 본 논문에서는 광섬유 장주기 격자를 이용한 센서 신호처리 시스템을 구현하였다. SLD와 Fabry-Perot 필터를 이용한 동조 반도체 광원과 Fabry-Perot 필터내의 PZT의 히스테리시스 특성을 보상하기 위한 에탈론 필터를 사용하였으며, 절대적인 기준 파장을 제공하기 위하여 온도 안정화된 광섬유 브래그 격자를 사용하였다. 시스템에서 검출된 신호를 A/D 변환하여 컴퓨터로 입력하고 신호 처리하여 결과를 모니터상에 표시하였다.

Fast Noise Reduction Approach in Multifocal Multiphoton Microscopy Based on Monte-Carlo Simulation

  • Kim, Dongmok;Shin, Younghoon;Kwon, Hyuk-Sang
    • Current Optics and Photonics
    • /
    • 제5권4호
    • /
    • pp.421-430
    • /
    • 2021
  • The multifocal multiphoton microscopy (MMM) enables high-speed imaging by the concurrent scanning and detection of multiple foci generated by lenslet array or diffractive optical element. The MMM system mainly suffers from crosstalk generated by scattered emission photons that form ghost images among adjacent channels. The ghost image which is a duplicate of the image acquired in sub-images significantly degrades overall image quality. To eliminate the ghost image, the photon reassignment method was established using maximum likelihood estimation. However, this post-processing method generally takes a longer time than image acquisition. In this regard, we propose a novel strategy for rapid noise reduction in the MMM system based upon Monte-Carlo (MC) simulation. Ballistic signal, scattering signal, and scattering noise of each channel are quantified in terms of photon distribution launched in tissue model based on MC simulation. From the analysis of photon distribution, we successfully eliminated the ghost images in the MMM sub-images. If the priori MC simulation under a certain optical condition is established at once, our simple, but robust post-processing technique will continuously provide the noise-reduced images, while significantly reducing the computational cost.

Current-induced Phase Demodulation Using a PWM Sampling for a Fiber-optic CT

  • Park, Hyoung-Jun;Lee, June-Ho;Kim, Hyun-Jin;Song, Min-Ho
    • Journal of the Optical Society of Korea
    • /
    • 제14권3호
    • /
    • pp.240-244
    • /
    • 2010
  • In this work, we used PWM sampling for demodulation of a fiber-optic interferometric current transformer. The interference signal from a fiber-optic CT is sampled with PWM triggers that produce a 90-degree phase difference between two consecutively sampled signals. The current-induced phase is extracted by applying an arctangent demodulation and a phase unwrapping algorithm to the sampled signals. From experiments using the proposed demodulation, we obtained phase measurement accuracy and a linearity error, in AC current measurements, of ~2.35 mrad and 0.18%, respectively. The accuracy of the proposed method was compared with that of a lock-in amplifier demodulation, which showed only 0.36% difference. To compare the birefringence effects of different fiber-optic sensor coils, a flint glass fiber and a standard single-mode fiber were used under the same conditions. The flint glass fiber coil with a Faraday rotator mirror showed the best performance. Because of the simple hardware structure and signal processing, the proposed demodulation would be suitable for low-cost over-current monitoring in high voltage power systems.

광 PCB의 광 회로층 제작 및 패키징 기술 (Fabrication for Optical Layer and Packaging Technology of Optical PCB)

  • 김태훈;허석환;정명영
    • 마이크로전자및패키징학회지
    • /
    • 제22권1호
    • /
    • pp.1-5
    • /
    • 2015
  • Recently, data throughput of smart electric devices increases dramatically. There is a great interest in a new technology which exceeds the limit of electrical transmission method. Optical PCB can supplement the weakness of electrical signal processing, the research for optical PCB is very active. In this paper, we propose the thermal imprint lithography process to fabrication optical layer of optical PCB and experiment to optimize the process conditions. We confirm process time, pressure, process temperature, demolding temperature and fabricate optical interconnection structure which has $45^{\circ}$ tilted mirror surface for confirm the interconnection efficiency.

산소포화도 측정을 위한 모듈형 펄스 옥시메터 개발 (A Development of Pulse Oximeter module for Measurement of $SpO_2$)

  • 이한욱;이주원;이종회;조원래;이건기
    • 한국정보통신학회논문지
    • /
    • 제4권3호
    • /
    • pp.575-583
    • /
    • 2000
  • 펄스 옥시메터는 수술실, 회복실, 집중 치료실 등에서 사용되는 산소포화도($SpO_2$)를 측정하는 방법 중 광흡수도를 이용하여 비관혈적인 방법으로 산소포화도륵 측정하는 장비이다. 펄스 옥시메터는 동맥혈의 광흡수도를 측정함으로써 혈액의 산소포화도를 나타낼 수 있다. 산소포화도를 측정하는 기존의 방법은 잡음을 제거하는 필터링 기술과 복잡한 처리 알고리즘, 그리고 많은 연산 수행 시간을 필요로 한다. 본 연구에서는 신호 검출 단계에서 적색광과 적외선광 각각의 AC 성분과 DC 성분을 분리하여 처리함으로써, 연산 알고리즘을 단순화 할 수 있었다. 그리고 시스템을 구현한 결과 기존의 방법(로그연산법, 미분법) 보다 속도향상과 0.3% 이상의 성능개선을 보였다.

  • PDF

레이저를 이용한 인공망막에서의 영상 신호 전달방법 (Image Signal Transfer Method in Artificial Retina using Laser)

  • 윤일용;이병호;김성준
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제51권5호
    • /
    • pp.222-227
    • /
    • 2002
  • Recently, the research on artificial retina for the blind is active. In this paper a new optical link method for the retinal prosthesis is proposed. Laser diode system was chosen to transfer image into the eye in this project and the new optical system was designed and evaluated. The use of laser diode array in artificial retina system makes system simple for lack of signal processing part inside of the eyeball. Designed optical system is enough to focus laser diode array on photodiode array in 20$\times$20 application.

격자형 구조물의 외부 진동 주파수 탐지를 위한 분포형 광섬유 센서 설계 및 실험 (Detection of Excited Vibration frequency on the Latticed Fence Structure Using a Distributed Fiber Optic Sensor)

  • 이종길
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문집
    • /
    • pp.234-237
    • /
    • 2002
  • To detect external vibration signals on the latticed fence structure, distributed fiber optic sensor using Sagnac interferometer was fabricated and tested. The latticed structure fabricated with dimension of 170cm in width and 180cm in height, the optical fiber, 50m in length, distributed and fixed on the latticed structure. It was verified the sensitivity of the Sagnac interferometer using the PZT phase modulator. Fiber optic external vibration signal spplied to the latticed fence structure from 100Hz to several kHz. The interferometeric fiber optic sensor detected the excited vibration signal very effectively without any signal processing. The detected optical signals were compared and analyzed to the detected acclerometer signals.

  • PDF

Amplitude Control of Phase Modulation for Dithered Closed-loop Fiber Optic Gyroscope

  • Chong, Kyoung-Ho;Chong, Kil-To;Kim, Young-Chul
    • Journal of the Optical Society of Korea
    • /
    • 제16권4호
    • /
    • pp.401-408
    • /
    • 2012
  • The amplitude error of phase modulator used in closed-loop fiber optic gyroscope has occurred by the temperature dependency of the electro-optic coefficient, and also can be due to the square-wave dither signal which is generally applied for eliminating the deadzone. This error can cause bias drift and scale factor error. This paper analyzes the temperature dependency of the modulation amplitude and the relationship with the scale factor of the gyroscope, and deals with an amplitude control method. The error calculation logic considering the dither signal is implemented on the signal processing module. The result of experiments from a prototype gyroscope shows the effect of the modulation amplitude control and a considerable improvement on performances.