• 제목/요약/키워드: Optical Set-Up

검색결과 158건 처리시간 0.021초

Performance of Continuous-wave Coherent Doppler Lidar for Wind Measurement

  • Jiang, Shan;Sun, Dongsong;Han, Yuli;Han, Fei;Zhou, Anran;Zheng, Jun
    • Current Optics and Photonics
    • /
    • 제3권5호
    • /
    • pp.466-472
    • /
    • 2019
  • A system for continuous-wave coherent Doppler lidar (CW lidar), made up of all-fiber structures and a coaxial transmission telescope, was set up for wind measurement in Hefei (31.84 N, 117.27 E), Anhui province of China. The lidar uses a fiber laser as a light source at a wavelength of $1.55{\mu}m$, and focuses the laser beam on a location 80 m away from the telescope. Using the CW lidar, radial wind measurement was carried out. Subsequently, the spectra of the atmospheric backscattered signal were analyzed. We tested the noise and obtained the lower limit of wind velocity as 0.721 m/s, through the Rayleigh criterion. According to the number of Doppler peaks in the radial wind spectrum, a classification retrieval algorithm (CRA) combining a Gaussian fitting algorithm and a spectral centroid algorithm is designed to estimate wind velocity. Compared to calibrated pulsed coherent wind lidar, the correlation coefficient for the wind velocity is 0.979, with a standard deviation of 0.103 m/s. The results show that CW lidar offers satisfactory performance and the potential for application in wind measurement.

SCAE와 SCAD를 이용한 광 CDMA시스템에서 간섭패턴 분석 (Interference Pattern Analysis in the Optical CDMA system using the SCAE and SCAD)

  • 강태구;최재경;박찬영;최영완
    • 대한전자공학회논문지SD
    • /
    • 제37권1호
    • /
    • pp.44-51
    • /
    • 2000
  • Series Coupler Access Encodler(SCAE)와 Series Coupler Access Decoder(SCAD)를 이용한 광CDMA(Code Division Multiple Access)시스템에서 광정합필터 특성을 삼차신호까지 고려하여 분석하였다. 기존의 연구에서는 SCAE 및 ACAD를 평가할 때, 일차신호만을 고려하여 시스템의 성능을 분석하여 성능평가가 정확하지가 않았다. SCAE 및 SCAD는 커플러 수를 증가함에 따라 여러 형태의 간섭신호들을 가지므로, 이러한 신호들이 자기상관과 상호상관 세기를 변화시킨다. 그러므로 좀 더 정확한 시스템 성능을 분석하기 위해서는 간섭신호들의 특성을 연구할 필요성이 있다. 본 논문에서는 복호화 되는 광신호를 삼차신호까지 수학적으로 해석하였고, 시스템의 자기상관과 상호상관에 미치는 영향을 모의실험을 통해 분석하였다. 커플러 수 증가에 따라 나타나는 삼차신호들이 간섭신호 형태가 되어 peak to side-lobe ratio를 감소키기는 요인으로 작용됨을 정량적으로 확인하였다. 간섭신호들의 크기는 ${\alpha}$(coupling coefficient)값이 커질수록 증가하였으며, 커플러 개수(N)=5, ${\alpha}$=0.5인 조건에서 삼차신호까지 고려한 peak to side-lobe ratio는 3.75 dB까지 열화됨을 밝혔다. 또한, 일차신호의 main-lobe세기에 의해 수신기의 임계레벨을 결정한다면, 삼차신호에 의해 증가된 side-lobes세기 때문에 SCAE와 SCAD를 이용한 광 CDMA system에 다중 접속할 수 있는 사용자 수가 제한됨을 알 수 있었다.

  • PDF

광학 현미경을 이용한 산화 그래핀 이미지 분석 조건에 관한 연구 (A Study on Image Analysis of Graphene Oxide Using Optical Microscopy)

  • 이유진;김나리;윤상수;오영석;이제욱;이원오
    • Composites Research
    • /
    • 제27권5호
    • /
    • pp.183-189
    • /
    • 2014
  • 광학 현미경 관찰을 통해 산화 그래핀의 형상, 크기 및 두께를 쉽게 파악할 수 있는 광학 관찰을 위한 최적 조건을 확보하고자 하였다. 본 연구에서는 $SiO_2$ 절연막이 300 nm 두께로 도포된 실리콘 기판 위의 산화 그래핀을 하이드라진 증기 환원을 통하여 본래의 모폴로지를 유지한 채 환원된 산화 그래핀의 이미지의 선명도를 증가시켰고, 녹색 필터를 사용한 관찰을 통해 이미지의 대비값을 보다 증대시켰다. 추가적으로 얻어진 광학 이미지를 RGB 채널별로 분리하는 방법을 제안하고 이를 통해 이미지를 분석하였다. 그 결과 하이드라진 증기 환원 처리 및 녹색 파장에서의 광원 하에서 고대비의 이미지 확보가 가능하였으며, 더불어 광학 이미지의 RGB 채널 분리만으로도 선명한 그래핀 이미지를 얻을 수 있음을 알아내었다.

액정표시장치 백라이트용 집광필름의 광학특성 분석을 위한 시뮬레이션 기법 연구 (Optical Simulation Study on the Performances of Collimating Films for LCD Backlight Applications)

  • 박지희;이정호;정진하;남기봉;고재현;김중현
    • 한국광학회지
    • /
    • 제18권6호
    • /
    • pp.432-440
    • /
    • 2007
  • LCD 백라이트에 사용되는 집광필름의 광학적 성능을 예측하는 효율적인 방법으로 광선추적기법이 적용된 광학 시뮬레이션이 많이 사용되고 있다. 집광필름의 광특성을 정확히 예측하기 위해서는 시뮬레이션에 영향을 미치는 조건들을 세심하게 설정하여야 한다. 본 연구에서는 가장 대표적인 집광필름인 프리즘필름의 시야각 특성 및 휘도상승률에 중요한 영향을 미치는 시뮬레이션 조건을 분석하기 위해 반사필름, 가상의 평면광원, 프리즘필름으로 구성된 간단한 BLU 모델을 구성한 후 다양한 조건 하에서 체계적인 시뮬레이션을 수행하였다. 그 결과 (1) 집광필름의 구조 및 재질 변화에 따른 광학적 성능, 특히 휘도상승률의 상대적 변화는 위에서 기술한 간단한 모델로도 충분히 예측할 수 있음을 확인하였고, (2) 집광필름의 시야각 특성을 정확히 예측하기 위해서는 반사필름의 반사성격 및 집광필름에 입사되는 빛의 분포를 시뮬레이션에 정확히 반영해야만 함을 확인할 수 있었다. 확산판, 확산필름 및 프리즘필름이 적층된 직하형 BLU에서 얻어진 실험결과와 시뮬레이션 결과를 비교 분석한 결과, 상기의 시뮬레이션 모델에 반사필름이 보이는 양방향반사분포함수를 적용하고 확산필름 위의 출광분포를 광원으로 이용할 경우 실험에서 얻어진 프리즘필름 위의 출광분포를 정확히 재현할 수 있음을 확인하였다.

DWDM 기반 차세대 광 인터넷 망에서 VS기반의 차등화된 멀티캐스트 라우팅 및 파장할당 알고리즘 연구 (A Study on Virtual Source-based Differentiated Multicast Routing and Wavelength Assignment Algorithms in the Next Generation Optical Internet based on DWDM Technology)

  • 김성운;박선영
    • 한국멀티미디어학회논문지
    • /
    • 제14권5호
    • /
    • pp.658-668
    • /
    • 2011
  • 지난 수 십 년간 통신 기술의 발전과 웹 서비스의 팽창은 인터넷 사용자 수의 폭발적인 증가와 화상회의, 가상 증감 현실, 인터넷 게임 등 실시간 멀티미디어 멀티캐스트 서비스의 급격한 증가를 초래했다. 고밀도 파장분할다중화기술에 기반한 DWDM(Dense-Wavelength Division Multiplexing) 기술은 인터넷 사용자의 증가와 그에 따른 대역폭 요구를 수용하기 위한 방안으로 국가나 글로벌 영역 범위의 차세대 인터넷망 구현을 위한 백본망 기술로 여겨지며, 이러한 DWDM 전달망에서는 멀티캐스트 연결 요구에 대해 최적의 경로를 선택하고 선택된 경로에 효율적으로 파장을 할당하는 멀티캐스트 RWA(Routing and Wavelength Assignment) 문제가 파장 대역폭의 효율적인 활용 측면에서 매우 중요하게 다루어지고 있다. 주어진 파장 수 환경에서 최대한 많은 수의 멀티캐스트 연결을 달성하는 문제는 일반적으로 Non -deterministic Polynomial-time-complete 문제로 여겨지는 데, 본 논문에서는 가상소스를 기반으로 노드의 능력에 따른 차등화로 우선 순위를 적용하여 휴리스틱하게 멀티캐스트 라우팅 경로를 효율적으로 선정하는 DVS-PMIPMR (Differentiated Virtual Source-based Priority Minimum Interference Path Multicast Routing) 알고리즘을 제안한다. 마지막으로 같은 조건에서 더 많은 수의 멀티캐스트 라우팅 패스의 연결이 가능함을 시뮬레이션 및 성능분석 증명한다.

The New X-ray Induced Electron Emission Spectrometer

  • Yu.N.Yuryev;Park, Hyun-Min;Lee, Hwack-Ju;Kim, Ju-Hwnag;Cho, Yang-Ku;K.Yu.Pogrebitsky
    • 한국결정학회:학술대회논문집
    • /
    • 한국결정학회 2002년도 정기총회 및 추계학술연구발표회
    • /
    • pp.5-6
    • /
    • 2002
  • The new spectrometer for X-ray Induced Electron Emission Spectroscopy (XIEES) .has been recently developed in KRISS in collaboration with PTI (Russia). The spectrometer allows to perform research using the XAFS, SXAFS, XANES techniques (D.C.Koningsberger and R.Prins, 1988) as well as the number of techniques from XIEES field(L.A.Bakaleinikov et all, 1992). The experiments may be carried out with registration of transmitted through the sample x-rays (to investigate bulk samples) or/and total electron yield (TEY) from the sample surface that gives the high (down to several atomic mono-layers in soft x-ray region) near surface sensitivity. The combination of these methods together give the possibility to obtain a quantitative information on elemental composition, chemical state, atomic structure for powder samples and solids, including non-crystalline materials (the long range order is not required). The optical design of spectrometer is made according to Johannesson true focusing schematics and presented on the Fig.1. Five stepping motors are used to maintain the focusing condition during the photon energy scan (crystal angle, crystal position along rail, sample goniometer rail angle, sample goniometer position along rail and sample goniometer angle relatively of rail). All movements can be done independently and simultaneously that speeds up the setting of photon energy and allows the using of crystals with different Rowland radil. At present six curved crystals with different d-values and one flat synthetic multilayer are installed on revolver-type monochromator. This arrangement allows the wide range of x-rays from 100 eV up to 25 keV to be obtained. Another 4 stepping motors set exit slit width, sample angle, channeltron position and x-ray detector position. The differential pumping allows to unite vacuum chambers of spectrometer and x-ray generator avoiding the absorption of soft x-rays on Be foil of a window and in atmosphere. Another feature of vacuum system is separation of walls of vacuum chamber (which are deformed by the atmospheric pressure) from optical elements of spectrometer. This warrantees that the optical elements are precisely positioned. The detecting system of the spectrometer consists of two proportional counters, one scintillating detector and one channeltron detector. First proportional counter can be used as I/sub 0/-detector in transmission mode or by measuring the fluorescence from exit slit edge. The last installation can be used to measure the reference data (that is necessary in XANES measurements), in this case the reference sample is installed on slit knife edge. The second proportional counter measures the intensity of x-rays transmitted through the sample. The scintillating detector is used in the same way but on the air for the hard x-rays and for alignment purposes. Total electron yield from the sample is measured by channeltron. The spectrometer is fully controlled by special software that gives the high flexibility and reliability in carrying out of the experiments. Fig.2 and fig.3 present the typical XAFS spectra measured with spectrometer.

  • PDF

산소포화도 측정을 위한 신호처리방법 및 계산 알고리즘 (Signl processing method and diagnostic algorithm for arterial oxygen-saturation measument)

  • 김수진;황돈연;전계진;이종연;정성규;윤길원
    • 한국광학회지
    • /
    • 제11권6호
    • /
    • pp.452-456
    • /
    • 2000
  • 동맥혈의 맥동성분에 의한 파장별 광흡수도를 측정하여 비침습적으로 산소포화도 값을 알수 있는 펄스옥시미터 장치와 신호처리방법을 개발하고 예측 알고리즘을 적용하였다. 본 장치는 광원 및 검출기로 구성된 프로브와 광신호 처리부, LED 구동회로 PC 인터페이스부로 구성되었고 데이터의 수집을 위한 구동소프트웨어 및 데이터 처리 소프트웨어를 개발하였다. 개발된 산소포화도 측정장치의 성능을 평가하는데에는 Bio-Tek 사의 펄스 옥시미터 시뮬레이터를 사용하여 다양한 알고리즘 및 데이터처리 방법들을 비교분석한 결과 맥동파형의 $In(I_p/I_v) 값을 I_{avr}$값으로 보정하는 계산 알고리즘의 방법과 진폭비보다 면적비를 이용한 계산방법이 산소포화도와의 상관관계가 우수한 것으로 나타났다. 정확한 신호 획득을 위해 개발된 맥동의 기저선 보상처리 프로그램을 inv-vivo 테스트의 데이터 처리방법에 적용하여 결과가 향상되는 것을 확인하였고 광원으로 660nm(Red)와 805nm(IR)파장을 이용한 경우보다 660nm(Red)와 940nm(IR) 파장을 이용했을 때 산소포화도와의 상관관계 및 정밀도에서 더 우수한 결과를 얻을 수 있었다.

  • PDF

전열화학포용 2.4MJ 펄스 파워 전원의 제어기 설계 (The Controller Design of a 2.4MJ Pulse Power Supply for a Electro-Thermal-Chemical Gun)

  • 김종수;진윤식;이홍식;임근희;김진성
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제55권12호
    • /
    • pp.511-517
    • /
    • 2006
  • The key issues in high power, high energy applications such as electromagnetic launchers include safety, reliability, flexibility, efficiency, compactness, and cost. To explore some of the issues, a control scheme for a large current wave-forming was designed, built and experimentally verified using a 2.4MJ pulse power system (PPS). The PPS was made up of eight capacitors bank unit, each containing six capacitors connected in parallel. Therefore there were 48 capacitors in total, with ratings of 22kV and 50kJ each. Each unit is charged through a charging switch that is operated by air pressure. For discharging each unit has a triggered vacuum switch (TVS) with ratings of 200kA and 250kV. Hence, flexibility of a large current wave-forming can be obtained by controlling the charging voltage and the discharging times. The whole control system includes a personal computer(PC), RS232 and RS485 pseudo converter, electric/optical signal converters and eight 80C196KC micro-controller based capacitor-bank module(CBM) controllers. Hence, the PC based controller can set the capacitor charging voltages and the TVS trigger timings of each CBM controller for the current wave-forming. It also monitors and records the system status data. We illustrated that our control scheme was able to generate the large current pulse flexibly and safely by experiments. The our control scheme minimize the use of optical cables without reducing EMI noise immunity and reliability, this is resulting in cost reduction. Also, the reliability was increased by isolating ground doubly, it reduced drastically the interference of the large voltage pulse induced by the large current pulse. This paper contains the complete control scheme and details of each subsystem unit.

665nm와 805nm의 파장을 이용한 인공심장용 혈중 산소포화도의 광학적 측정 (Optical Measurement of Blood Oxygen Saturation for Artificial Heart Using Wavelength of 665nm and 805nm)

  • 박세광;권기진
    • 센서학회지
    • /
    • 제2권1호
    • /
    • pp.75-80
    • /
    • 1993
  • 본 논문에서는 혈액의 산소포화도를 비추출식으로 측정하기 위한 광 센서와 센서 시스템을 나타내었다. 광센서의 광원으로는 665nm와 805nm의 파장을 가지는 LED를 사용하여 구성하였고, 감지기로는 PIN 포토다이오드를 이용하여 각 센서부를 구성하였다. 이들 광원과 감지기를 이용하여 Flat Pack에 광 센서를 제작하였다. 혈액의 산소포화도를 측정하기 위한 센서 시스템을 신호 증폭기, 필터, 디스 플레이 장치, A/D 컨버터, 마이크로프로세서와 메모리 등으로 설계, 제작하였다. 그리고, 비추출식으로 산소포화도를 측정하기 위한 모의 실험 장치를 구성하여 모의 실험을 행하였다. 실험 결과, 산소포화도의 변화에 따른 각 파장의 출력치 변화를 비교하여 보면 665nm의 파장에서의 출력 변화가 805nm의 파장에서의 출력 변화보다 5배 정도 크게 변화하였다. 그리고, 산소포화도가 100%에서 60%로 변화할 때, 각 파장의 비(R805/R665)는 선형적으로 변화하였다. 그러므로, 100%에서 60%까지의 산소포화도 범위에서, 개발된 센서는 산소포화도의 변화를 5% 정도의 해상도로서 측정가능하였다. 따라서, 개발된 광센서가 인공 심장의 대동맥과 대정맥에 연결된다면 정확하고 신속하게 인공 심장을 제어할 수 있을 것이다.

  • PDF

표정과 동작 데이터의 자동 동기화 기술 (Automatic Synchronization of Separately-Captured Facial Expression and Motion Data)

  • 정태완;박상일
    • 한국컴퓨터그래픽스학회논문지
    • /
    • 제18권1호
    • /
    • pp.23-28
    • /
    • 2012
  • 본 논문은 동작 포착 장비를 통해 각각 따로 포착된 얼굴과 동작 데이터의 자동 동기화 기술에 대해 다룬다. 광학식 동작 포착 기기를 사용할 때 얼굴 표정과 동작의 포착은 별도로 이루어지는 경우가 많으며, 이 경우 두 데이터 간의 동기화 수행하여야 자연스러운 애니메이션을 만들 수 있다. 본 연구에서는 두 데이터 간의 공통 부분인 목 및 얼굴의 전체적인 움직임 데이터를 기준으로 비선형 시간 변형을 통해 동기화를 수행하는 기법을 제안한다. 연구 결과를 간단한 실험 시나리오에 적용하여 기술의 효과성 여부를 검증하였다.