• Title/Summary/Keyword: Opposite discharge

검색결과 49건 처리시간 0.028초

아크의 방전에 따른 전기안전에 미치는 영향 (Interruption Controller Design of Arc current With Custom Electric Source)

  • 반기종;임승하;원영진
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2005년도 추계종합학술대회
    • /
    • pp.1283-1286
    • /
    • 2005
  • Arc Fault Current is an electric discharge which is occurred in two opposite electrode. In this paper, arc current control algorithm is designed for the interruption of arc fault current which is occurred in the local electric network. This arc is one of the main causes of electric fire. Arc fault in electrical network has the characteristics of low current, high impedance and high frequency. Conventional arc current controller does not have the arc current interrupt function. Hence, Controller of arc current is designed for the interruption of arc fault current which has the modified arc characteristics.

  • PDF

선회실속하의 원심 임펠러 출구 유동 특성 (Flow Characteristics of Centrifugal Impeller Exit under Rotating Stall)

  • 신유환;김광호
    • 한국유체기계학회 논문집
    • /
    • 제2권2호
    • /
    • pp.5-12
    • /
    • 1999
  • This study presents the measured unsteady flctuation of impeller discharge flow for a centrifugal compressor in an unstable operating region. The characteristics of the blade-to-blade flow at rotating stall onset were investigated by measuring unsteady velocity fluctuations at several different diffuser axial distances using a hot wire anemometer. The flow characteristics in terms of the radial and tangential velocity components and the flow angle distribution at the impeller exit were analyzed using phase-locked ensemble averaging techniques. As a result, increase or decrease of the radial velocity component during the rotating stall is dominated by that of the suction side. The radial velocity distributions show the opposite trends in the regions where the radial velocity during rotating stall onset increases and decreases.

  • PDF

선회실속하의 원심 임펠러 출구 유동 특성 (Flow Characteristics of centrifugal Impeller Exit Under Rotating Stall)

  • 신유환;김광호
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 1998년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.129-134
    • /
    • 1998
  • This study presents the measured unsteady fluctuation of impeller discharge flow for a centrifugal compressor in unstable operating region. The characteristics of the blade-to-blade flow at rotating stall onset were investigated by measuring unsteady velocity fluctuations at several different diffuser axial distances using a hot wire anemometer. The flow characteristics in terms of the radial and tangential velocity components and the flow angle distribution at the impeller exit were analyzed using phase-locked ensemble averaging techniques. As a result, increase or decrease of the radial velocity component during the rotating stall is dominated by that on the suction side. The radial velocity distributions show the opposite trends in the regions where the radial velocity during rotating stall onset increases and decreases.

  • PDF

전기화재 방지를 위한 아크고장전류 차단기 설계 (Arc Fault Circuit Interrupter Design for Electrical Fire Protection)

  • 반기종;김낙교
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제55권5호
    • /
    • pp.220-225
    • /
    • 2006
  • Arc Fault Current is an electric discharge which is occurred in two opposite electrode. In this paper, AFCI(arc fault circuit interrupter) is designed for the interruption of arc fault current which is occurred in the local electric network. This arc is one of the main causes of electric fire. Arc fault in electrical network has the characteristics of low current, high impedance and high frequency. Conventional arc fault circuit interrupter does not have the arc current interrupt function. Hence, Arc current controller is designed for the interruption of arc fault current which has the modified arc characteristics.

전기화재 방지를 위한 AFCI 알고리즘 설계 (AFCI algorithm design for electrical fire protection)

  • 반기종;최성대;남문현;김낙교
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 D
    • /
    • pp.1769-1770
    • /
    • 2006
  • Arc Fault is an electric discharge which is occurred in two opposite electrode. In this paper, AFCI(arc fault circuit interrupter) is designed for the interruption of arc fault current which is occurred in the local electric network. This arc is one of the main causes of electric fire. Arc fault in electrical network has the characteristics of low current, high impedance and high frequency. Conventional interrupter does not have the arc current interrupt function. Hence, Arc fault circuit interrupter controller is designed for the interruption of arc fault current which has the modified arc characteristics.

  • PDF

DC Arc 검출장치에 대한 연구 (A Study of DC Arc Detection Device)

  • 반기종;남문현;김낙교
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 심포지엄 논문집 정보 및 제어부문
    • /
    • pp.98-100
    • /
    • 2007
  • DC Arc Fault Current is an electric discharge which is occurred in two opposite electrode. In this paper, DC arc detection device is designed for the display of DC arc fault current which is occurred in the local electric network with DC Power. This DC arc is one of the main causes of electric fire. Arc fault in electrical network has the characteristics of low current, high impedance and low frequency. DC Arc current detection device is designed for the display of arc fault current which has the modified arc characteristics.

  • PDF

센서없는 아크고장전류 제어 알고리즘 설계 (Design of Control a Algorithm for Arc Fault Current without Current Sensor)

  • 반기종;김낙교
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제55권6호
    • /
    • pp.255-260
    • /
    • 2006
  • Arc Fault Current is an which occurrs in two opposite electrode. In this paper, arc current control algorithm is designed for the interruption of arc fault current which is occurred in the low voltage network. This arc is one of the main causes of electric fire. General arc current sensor has troubles for detecting arc currents, thus we would like to propose the arc current detection method without current sensor. In this parer, arc discharge currents within power lines are being detected through the arc current control algorithm.

제뇌(除腦) 고양이의 경부(頸部) 회전자극에 대한 상완근(上腕筋)의 반응 (Response of Brachial Muscles to Neck Rotation in the Decerebrate Cat)

  • 이동선;박병림;김상수
    • The Korean Journal of Physiology
    • /
    • 제24권1호
    • /
    • pp.103-113
    • /
    • 1990
  • The role of cervical proprioceptors in the control of body posture was studied in bilaterally labyrinth-ectomized, decerebrate cats. The animals were suspended on hip pins with the neck extended horizontally. With this placement the EMG activities of extensor and flexor muscles of the upper extremities were observed by means of sinusoidal head rotator. The rotator can induce two kinds of neck movement: The one is 'pitch' which describes a rotatory neck motion to transverse axis of the body and mainly occurs at skull-C1 (atlantooccipital) joint and the other is 'roll', side-to-side relation of the neck to longitudinal axis, whose center is C1-C2 (atlanto-axial) joint. The following results were obtained. 1) Responses of EMG activity were closely dependent on the rotatory range of the neck. And the EMG activity was not changed during sustained neck torsion, eliciting a typical tonic neck reflex. 2) On pitching movement, the head-up rotation produced the excitation of bilateral triceps muscles, whereas the head-down rotation produced the inhibition. And the response of bilateral biceps muscles was the opposite to that of triceps. 3) On rolling movement, the side-up rotation of the head produced the excitation of ipsilateral triceps muscles and the inhibition of contralateral ones. And the response of biceps muscles was the opposite to that of triceps. 4) The minimum requirement of motion to evoke EMG activities in the upper extremities was $3.2^{\circ}{\sim}12.5^{\circ}$. These results have shown that the cervical proprioceptors produce tonic discharge on the upper brachial muscles, regulate the EMG activities of those muscles, and are very sensitive to neck rotation. And it can be stated that the cervical proprioceptors may play an important role in the control of body posture and movement.

  • PDF

SCR 기반 양방향성 ESD보호회로의 설계 변수 변화에 따른 전기적 특성의 관한 연구 (A Study on the Electrical Characteristic of SCR-based Dual-Directional ESD Protection Circuit According to Change of Design Parameters)

  • 김현영;이충광;남종호;곽재창;구용서
    • 전기전자학회논문지
    • /
    • 제19권2호
    • /
    • pp.265-270
    • /
    • 2015
  • 본 논문에서는 높은 홀딩 전압을 갖는 SCR(silicon-controlled rectifier)기반 양 방향성 ESD 보호회로를 제안하였다. 일반적인 ESD 보호회로와 달리 양방향의 ESD Stress mode의 방전경로를 제공하며 높은 홀딩전압으로 latch-up면역 특성을 갖어 효과적인 ESD보호를 제공한다. 또한, 높은 홀딩전압을 위한 설계변수인 Gate Length와 N+bridge Length의 길이 변화에 따른 시뮬레이션을 Synopsys사의 TCAD 시뮬레이터를 사용하여 확인 하였다. 시뮬레이션 결과 2.1V에서 6.5V까지 홀딩 전압의 증가로 latch-up 면역 특성을 개선 하였으며, 기존 SCR보다 6.5V의 낮은 트리거 전압특성을 갖고 있어 제안된 ESD 보호 회로는 5V 이상의 공급전압을 갖는 application에 적용 가능하다.

Climatological variability of surface particulate organic carbon (POC) and physical processes based on ocean color data in the Gulf of Mexico

  • Son, Young-Baek;Gardner, Wilford D.
    • 대한원격탐사학회지
    • /
    • 제27권3호
    • /
    • pp.235-258
    • /
    • 2011
  • The purpose of this study is to investigate climatological variations from the temporal and spatial surface particulate organic carbon (POC) estimates based on SeaWiFS spectral radiance, and to determine the physical mechanisms that affect the distribution of pac in the Gulf of Mexico. 7-year monthly mean values of surface pac concentration (Sept. 1997 - Dec. 2004) were estimated from Maximum Normalized Difference Carbon Index (MNDCI) algorithm using SeaWiFS data. Synchronous 7-year monthly mean values of remote sensing data (sea surface temperature (SST), sea surface wind (SSW), sea surface height anomaly (SSHA), precipitation rate (PR)) and recorded river discharge data were used to determine physical forcing factors. The spatial pattern of POC was related to one or more factors such as river runoff, wind-derived current, and stratification of the water column, the energetic Loop Current/Eddies, and buoyancy forcing. The observed seasonal change in the POC plume's response to wind speed in the western delta region resulted from seasonal changes in the upper ocean stratification. During late spring and summer, the low-density river water is heated rapidly at the surface by incoming solar radiation. This lowers the density of the fresh-water plume and increases the near-surface stratification of the water column. In the absence of significant wind forcing, the plume undergoes buoyant spreading and the sediment is maintained at the surface by the shallow pycnocline. However, when the wind speed increases substantially, wind-wave action increases vertical motion, reducing stratification, and the sediment were mixed downward rather than spreading laterally. Maximum particle concentrations over the outer shelf and the upper slope during lower runoff seasons were related to the Loop Current/eddies and buoyancy forcing. Inter-annual differences of POC concentration were related to ENSO cycles. During the El Nino events (1997-1998 and 2002-2004), the higher pac concentrations existed and were related to high runoffs in the eastern Gulf of Mexico, but the opposite conditions in the western Gulf of Mexico. During La Nina conditions (1999-2001), low Poe concentration was related to normal or low river discharge, and low PM/nutrient waters in the eastern Gulf of Mexico, but the opposite conditions in the western Gulf of Mexico.