• Title/Summary/Keyword: Ophthalmic lens

Search Result 521, Processing Time 0.029 seconds

UV Absorbent-added Polymerization and its Application as Ophthalmological Material (자외선 흡수제를 첨가한 고분자 중합 및 안 의료용 소재로의 적용)

  • Sung, A-Young;Kim, Tae-Hun;Ye, Ki-Hun
    • Journal of the Korean Chemical Society
    • /
    • v.55 no.1
    • /
    • pp.98-103
    • /
    • 2011
  • This study was done for the preparation of macromolecular material with UV-blocking features by adding the benzophenone group that is commonly used as a UV-absorbent and $TiO_2$ which is known to be a very stable material in chemical and physical aspects. Also, we compared the level of UV absorbency of the polymer produced from polymerization with previous materials and measured basic properties such as water content, refractive index and optical transmittance of produced contact lenses. The results of the measurement showed that the refractive index and water content of the contact lens with added UV-absorbent was 1.430~1.440 and 35.0~45.0% respectively, which was similar to that of previous contact lenses. Also, for optical transmittances of each wave length, contact lenses without the UV-absorbent was 89%, 88% and 89% respectively for UV-A, UV-B and visible light, indicating that the UV transmittance is very high though contrary with cases of contact lenses with added 2-hydroxy-4-methoxy-benzophenone and 2,4-dihydroxy-benzophenone which showed transmittances of 0% and 6% respectively for UV-A and UV-B showing a UV-blocking effect. Meanwhile, contact lenses with added $TiO_2$ showed transmittance of 6% and 51% respectively for UV-A and UV-B also showing a UV-blocking effect. The visible transmittance was 77~89% showing that it satisfies the visible transmittance required for ophthalmological materials.

Relationship Between Vergence Facility and Fusional Vergence (버전스용이와 융합버전스의 관계)

  • Shin, Hoy-Sun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.3
    • /
    • pp.37-42
    • /
    • 2009
  • Purpose: There is uncertainty if the vergence facility would provide clinically significant supplementary information to the fusional vergence measurements. The purpose of this study was to determine the relationship between vergence facility and fusional vergence in a group of symptomatic subjects. Methods: A total of 114 symptomatic subjects aged 9 to 13 years, who passed the vision screening test, participated in this study. Vergence facility was measured with 8$\Delta$ BI/8$\Delta$ BO flipper lenses and a suppression control target, the 20/30 letter line on Vectogram 9 (Bernell, USA). Near fusional vergence was measured with a single 20/30 vertical line target by Von Graefe technique. In order to avoid excessive convergence stimulation, negative fusional vergence (NFV) range (blur, break and recovery) was measured followed by positive fusional vergence (PFV) ranges (blur, break and recovery). Results: Pearson correlations were calculated and showed no correlations between vergence facility and any of fusional vergence measurements (p>0.05). Also, there were no significant differences of vergence facility measurements on the compensating vergence that passed or failed Sheard and Morgan's criterion for comfortable vision (p>0.05). Conclusions: There was no correlation between vergence facility and fusional vergence among symptomatic subjects. Hence, both vergence facility and fusional vergence should be assessed for those with binocular dysfunction in order to make an accurate diagnosis and management plan.

  • PDF

Ophthalmic Application of Hydrogel Polymer Containing Carbon Nanomaterials

  • Seok, Jae-Wuk;Geum, Yong-Pil;Shin, Dong-Seok;Sung, A-Young
    • Journal of Integrative Natural Science
    • /
    • v.12 no.4
    • /
    • pp.116-121
    • /
    • 2019
  • This experiment is to evaluate the physical properties of the hydrogel lens with the addition of carbon-based nanomaterials, Graphene oxide and Carbon nanotube, and to confirm the improvement of strength. Hyaluronic acid, a hydrophilic substance, was used as an additive by using HEMA (2-hydroxyethyl methacrylate) and ethylene glycol dimethacrylate (EGDMA) as a base monomers. Graphene oxide and two types of Carbon nanotubes(Amide functionalized and Carboxilic acid functionalized) were added 0.1%, 0.3%, 0.5%, respectively, and the physical properties were analyzed by measuring water content, refractive index, breaking strength and SEM image. In the case of the sample added with each carbon nano material, the water content tended to increase for all three materials. The breaking strength tended to increase in Graphene oxide and Carbon nanotube; Carboxilic acid functionalized, but in the case of Carbon nanotube; amide fuctionalized, the breaking strength tended to decrease. However, Carbon nanotube; amide fuctionalized had the highest breaking strength among the three nano materials. Thus, the addition of certain carbon nanomaterials seems to be appropriate for improving the strength of hydrogel lenses.

A Study on the Change of Corneal Refractive Power before and after Wearing RGP Contact Lenses by Flat Fitting and Alingment Fitting with Diagnostic Method (RGP 콘택트렌즈의 진단적 피팅법에 의한 플랫한 피팅과 얼라인먼트 피팅 착용 전·후 각막 굴절력의 변화에 관한 연구)

  • Lee, Dae-Won;Kim, In-Suk
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.2
    • /
    • pp.163-169
    • /
    • 2014
  • Purpose: This study is for compared the change of corneal refractive power before and after wearing of rigid gas permeable contact lense with diagnostic method which is 1 D flatter than alignment fitting on right eye and alignment fitting on left eye for 2 months and investigate the preference. Methods: Twenty middle school and high school students (40 eyes) who had never worn a contact lense before for no corneal topographical change, no ocular disease, no experience of ophthalmic surgery and have normal tear amount were selected for this study and corneal refractive power were examined before wearing rigid gas permeable contact lense and adaptation status and corneal examination were performed after 10 days of wearing and after cheking up the continuation of wearing, all candidate wear contact lens 8 hours per day for 2 month and corneal refractive power were compared. Results: After 2 months of wearing with 1 D flatter than the alignment fitting on right eyes, there was significant difference in the central corneal refractive power was $43.84{\pm}1.33D$, flat K power was $43.05{\pm}1.29D$, and steep K power was $44.61{\pm}1.42D$ decreased than before wearing (p<0.001, 0.001, 0.047). The e-value of the principal meridians also shows statistically significant difference (p=0.037, 0.015). After 2 months of wearing with alignment fitting on left eyes, the central corneal refractive power was $44.40{\pm}1.26D$, flat K power was $43.57{\pm}1.23D$. and flat K e-value was $0.58{\pm}0.05$ which showed no statistically significant difference (p = 0.769, 0.614, 0.181). But steep K power was $45.25{\pm}1.36$, and steep K e-value was $0.45{\pm}0.18$ which shows statistically significant difference (p=0.018, 0.027). Conclusions: Consider the comfort, clear vision, dryness for preference fitting investment, 6 students (30%) prefer right eye which is 1 D flatter fitting, 14 students (70%) prefer left eye which is alignment fitting. For rigid gas permeable fitting needed for accurate examination and should prescribe the alignment fitting which is suitable for each cornea.

A Study on the Relationship between the Disc of Least Confusion and Corrected Vision of Astigmatism (난시안의 최소착락원과 교정시력과의 관계 연구)

  • Kim, Jung-Hee;Kim, In-Suk
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.2
    • /
    • pp.51-57
    • /
    • 2008
  • Purpose: This study has been conducted to know how the size and position of the circle of least confusion has an influence on the vision for minimization of asthenopia when astigmatism is corrected and appropriated prescription to provided clear vision life. Methods: The method of the study has been worked on 68 students (136 eyes) of man and woman enrolled in university of Gyeong-gi-do aged 20 to 40, who have myopic astigmatism in order to know how the corrected vision changes according to the size and position of the circle of least confusion of astigmatism, the vision has been tested by giving the vision whose astigmatic power of 0.25D and 0.50D was just reduced, low correcting the astigmatic power into 0.50D, and at the same time inserting additionally spherical power -0.25D, all under a condition that the corrected vision after completely corrected astigmatism, and the axis of astigmatism was not changed. Results: The average vision was 1.047 when the astigmatic power was fully corrected, and in low correction of 0.25D, it was 0.914, and in low correction of 0.50, it was 0.772. It has been learned that the bigger the circle of least confusion was the bigger the range of vision reduction and the corrected vision in astigmatism has correlation with the size of the circle of least confusion. It has been examined that the average vision according to position of the circle of least confusion in astigmatism was 1.047 when the astigmatic power was completely corrected and focused on the retina with state of point, and in case that the astigmatic power was 0.50D of state of low correction, that is, the circle of least confusion was focused before retina, it was 0.828, and it was also 0.826 when the astigmatic power is low corrected with 0.50D and the circle of least confusion was focused on the retina. Explained briefly, It has been examined that in case that the state of low correction of the astigmatic power was same, the vision reduction was less in the image of the circle of least confusion focused upon the retina than in the image of its being focused before the retina. Conclusions: In case that the refractive power of cylindrical lens is reduced in test of wearability in astigmatism, there needs surely an adjustment of spherical lens that can place the circle of least confusion on the retina.

  • PDF

Predicting Powers of Spherical Rigid Gas-permeable Lenses Prescription (구면 RGP 렌즈의 처방 굴절력 예측)

  • Yu, Dong-Sik;Yoo, Jong-Sook
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.3
    • /
    • pp.219-225
    • /
    • 2010
  • Purpose: Usefulness in predicting the power of spherical rigid gas-pearmeable (RGP) lenses prescription using dioptric power matrices and arithmetic calculations was evaluated in this study. Noncycloplegic refractive errors and over-refractions were performed on 110 eyes of 55 subjects (36 males and 19 females, aged $24.60{\pm}1.55$years) in twenties objectively with an auto-refractometer (with keratometer) and subjectively. Tear lenses were calculated from keratometric readings and base curves of RGP lenses, and the power of RGP lenses were computed by a dioptric power matrix and an arithmetic calculation from the manifest refraction and the tear lens, and were compared with those by over-refractions in terms of spherical (Sph), spherical quivalent (SE) and astigmatic power. Results: The mean difference (MD) and 95% limits of agreement (LOA=$MD{\pm}1.96SD$) were better for SE (0.26D, $0.26{\pm}0.70D$) than for Sph (0.61D, $0.61{\pm}0.86D$). The mean difference and agreement of the cylindrical power between matrix and arithmetic calculation (-0.13D, $-0.13{\pm}0.53D$) were better than between the others (-0.24D, $0.24{\pm}0.84D$ between matrix and over-refraction; -0.12D, $0.12{\pm}1.00D$ between arithmetic calculation and over-refraction). The fitness of spherical RGP lenses were 54.5% for matrix, 66.4% for arithmetic calculation and 91.8% for over-refraction. Arithmetic calculation was close to the over-refraction. Conclusions: In predicting indications and powers of spherical RGP lens fitting, although there are the differences of axis between total (spectacle) astigmatism and corneal astigmatism, Spherical equivalent using an arithmetic calculation provides a more useful application than using a dioptric power matrix.

Evaluation of Visual Performance for Implanted Aspheric Multifocal Intraocular Lens in the Cataract Patients (백내장 환자에서 비구면 다초점 인공수정체 삽입 후 시기능 평가)

  • Kim, Jae-Yoon;Lee, Koon-Ja
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.3
    • /
    • pp.347-356
    • /
    • 2013
  • Purpose: To evaluate the visual acuity and visual performance after implantation of a aspheric multifocal (ReSTOR$^{(R)}$ SN6AD3) intraocular lens (IOL). Methods: Nineteen cataract patients (30 eyes) implanted with an aspheric multifocal IOL (ReSTOR$^{(R)}$ SN6AD3) either unilaterally or bilaterally were participated. Visual acuity (VA) and objective optical performance were evaluated at the time of preoperation, 1 week, 1 month, and 3 month after operation. At 3 month of post-operation, objective visual performance were measured and compared with the 38 eyes of 20 age-matched normal control. Distance VA was measured by using the ETDRS LCD chart and intermediate and near visual acuity were measured using Jaeger chart. Objective visual performance was assessed preoperatively and 1 week, 1 month and 3 month postoperatively using a double-pass system (Optical Quality Analysis System) with a 4-mm pupil diameter, the OSI (objective scatter index), MTF (modulation transfer function) cut off and strehl ratio. At 3 month of post-operation, visual acuity and visual performance compared with age matched normal control. Results: The uncorrected distance VA, OSI, MTF cut off and strehl ratio were significantly improved (p<0.05) until 1 month postoperatively. Visual performance of MTF cut off and strehl ratio after 3 month of operation were significantly improved compared to the normal control (p=0.063, p=0.103 respectively), however, OSI was higher than normal control. Patients implanted with aspheric multifocal IOL were satisfied with distance and near VA however, were unsatisfied with intermediate VA and reported glare and halos. Conclusions: The visual performance reaches to a stable condition in 1 month of implantation of aspheric multifocal IOL and improved to the level of age-mated normal patients. Also patients were satisfied with their quality of vision, however, intermediate VA, glare and halos were reported as complications.

A Study on the Spectacles Wearing State of High School Students (고등학생들의 안경착용에 관한 연구)

  • Doo, Ha-Young;Sim, Sang-Hyun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.5 no.1
    • /
    • pp.107-116
    • /
    • 2000
  • This study is of investigation of refraction error, spectacles and contact lenses wearing state, visual acuity test, ophthalmologic common sense and vision care, using questionnaire study for 850 male and female high school students in Kunsan and Chongup City, Cheolla North Province. The results are as follows: 1. Among the 823 answerers, emmetropia is 18%, myopia is 55.1%, and hyperopia is 7%, respectively. 2. Among the 837 answerers, 381 students(45.5%) wear spectacles or contact lenses. Among the 381 students who wear spectacles or contact lenses, 78% wear only spectacles, 4% wear only contact lenses and 18% wears spectacles sometimes or contact lenses sometimes. 3. The places where the answerers had visual acuity test to wear spectacles or contact lenses are optical shop(64.7%), hospital(28.3%), unchecked(4.2%) and the others(2.7%). The places where the answerers had visual acuity test to change their spectacles or contact lenses are optical shop(82%), hospital(28.3%), unchecked(6.6%) and the others(1.9%). 4. As for the period of visual acuity test, from 6 months to one year is 54.1%, within 6 months is 9.2%, from one year to two years is 29.5%, and more than two years is 7.2%. 5. The contact lens wearers purchased their contact lenses at optical shops(94%) and at hospital(6%). 6. The reasons why they like wearing contact lenses are their appearance(51.2%), convenience in physical excercise(23.l%), lighter weight than spectacles(9.8%) and the others(15.7%). 7. As for the spectacles frame they like, plastic frame is 24.4%, gold or silver plated frame is 43.4%, coloured frame is 32.1%. 8. As for the considerations in choosing spectacles frame, their design is 37%, their quality is 36%, their price is 14.7% and their brand is 12.5%. 9. As for the period for changing spectacles, 10.5% is within 6 months, 57.3% is 6months to 1 year, 22.4% is 1 year to 2 months and 9.6% is more than 2 years. 10. There is a false fact, in Korea, that even though one has his poor eyesight, not wearing custom is helpful for the eyesight recovery. As for their conviction of the false fact, 10.5% of the answerers have 100% conviction, 22.5% of them have 22.5% conviction, 49.5% of them have 50% conviction and 17.5% of them don't have any conviction. 11. 48.5% of the answerers are interested in their vision care while 51.5% of them are not interested at all. As for the way of vision care, the vision-care way to keep enough distant when they are watching TV, when they are using computers and when they are reading, is 49% while the vision-care way such as hypogastric breathing or eye massage is 11%. And alimentotherapy is 4% and the rest who are not interested in vision care is 36%. 12. When they come to an age, the students who want vision correction operation are 45.9% while the students who do not want it are 27%. The students who do not have any idea about the operation are 27.1%

  • PDF

The Changes in Contrast Sensitivity and Glare Sensitivity when Wearing Circle Contact Lenses after the Refractive Surgery (시력교정술 후 써클콘택트렌즈 착용 시 대비감도 및 눈부심감도 변화)

  • Kwon, Ki Nam;Park, Sang Hee;Kim, So Ra;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.21 no.1
    • /
    • pp.23-34
    • /
    • 2016
  • Purpose: In the present study, the effect of circle contact lenses wear on contrast sensitivity and glare sensitivity in a refractive surgery group was investigated. Methods: The contrast sensitivity and glare sensitivity were evaluated using by CGT-1000 for a non-refractive surgery group as control group(40 eyes) and a refractive surgery group(30 eyes) applied plano circle contact lenses, and pupil size was also measured. The correlation between contrast/glare sensitivity and the pupil size was analyzed. Results: In the refractive surgery group, contrast sensitivity in the range of high spatial frequency decreased with wearing circle contact lenses, and amount of decrease for the refractive surgery group was larger than for the control group. The correlation between pupil size and the change of contrast sensitivity was decreased by wearing circle contact lenses, and the correlation was lower in the refractive surgery group than the control group. Furthermore, the wear of circle contact lenses affected on glare sensitivity. In analyzing the change of glare sensitivity by pupil size, the glare was larger in the refractive surgery group than control group. Circle contact lenses in refractive surgery group were not fitted on the center of cornea. Conclusions: In the present study, it is suggested that the sufficient understanding and consideration about the decrease of contrast sensitivity and the increase of glare by wearing circle contact lenses after the refractive surgery is necessary.

Changes in Visual Function After Viewing an Anaglyph 3D Image (Anaglyph 3D입체 영상 시청 후의 시기능 변화)

  • Lee, Wook-Jin;Kwak, Ho-Won;Son, Jeong-Sik;Kim, In-Su;Yu, Dong-Sik
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.2
    • /
    • pp.179-186
    • /
    • 2011
  • Purpose: This study aimed to compare and assess changes of visual functions in viewing an anaglyph 3D image. Methods: Visual functions were examined before and after viewing a 2D image and an anaglyph 3D image with red-green glasses on seventy college students (mean age = 22.29${\pm}$2.19 years). Visual function tests were carried out for von Graefe phoria test, accommodative amplitude test by (-) lens addition, negative relative accommodation (NRA) and positive relative accommodation (PRA) test, negative relative convergence (NRC) and positive relative convergence (PRC) test, accommodative facility, and vergence facility test. Results: Assessment of the visual functions indicated that near exophoria and accommodative amplitude were reduced after viewing a 3D image, and although there were small changes in relation to these findings, NRC and PRC showed tendencies to increase and decrease at near, respectively. There were no significant changes with NRA and PRA, and accommodative and vergence facility were shown to have improved. Conclusions: Changes of visual functions were more in the 3D image than the 2D image, especially at near than distance. Particularly, the improvement of accommodative and vergence facility could be related to an effect of subsequent accommodation and vergence shift to have stereopsis in the 3D image. These results indicate that an anaglyph 3D image may, to some extent, be the effect of vision training such as anaglyphs.