• Title/Summary/Keyword: Operation range

Search Result 3,336, Processing Time 0.034 seconds

Performance Assessment and Design Evaluation of Bioretention Planter Boxes Treating Urban Stormwater Runoff (도심지역 강우유출수 처리목적 식물재배화분의 성능 및 설계인자 분석)

  • Guerra, Heidi B.;Park, Kisoo;Kim, Youngchul
    • Journal of Wetlands Research
    • /
    • v.20 no.1
    • /
    • pp.72-79
    • /
    • 2018
  • Two planter boxes were monitored during their initial year of operation to be able to assess their stormwater runoff and pollutant reduction capabilities and investigate on the design factors affecting their performance. One of the planter boxes provided 85-100% runoff volume reduction for rainfall less than 15 mm and rainfall intensities lower than 5 mm/hr. This reduced to 50-64% during higher rainfall intensities and depths of up to 50 mm. Suspended solids, organics, nutrients, and heavy metals were satisfactorily removed at a range of 40-95%. The other planter box, however, did not produce outflow in all the events and allowed total capture of stormwater. The uncertainty regarding the fate of the runoff in that case required an investigation of the planter box's actual drainage and underground conditions which was deemed outside the scope of the study. Nonetheless, several design improvements and retrofits were suggested based on the provisions of current design guidelines to ensure that the hydraulic and water quality goals are achieved without potential damage to nearby structures. Moreover, continuous monitoring data is required to provide more accurate design evaluation and can serve as a guide in the construction of similar facilities in the future.

Equilibrium, Kinetics and Thermodynamic Parameters Studies on Metanil Yellow Dye Adsorption by Granular Activated Carbon (입상활성탄에 의한 메타닐 옐로우 염료의 흡착에 대한 평형, 동력학 및 열역학 파라미터에 관한 연구)

  • Lee, Jong-Jib
    • Applied Chemistry for Engineering
    • /
    • v.25 no.1
    • /
    • pp.96-102
    • /
    • 2014
  • Adsorption of metanil yellow onto granular activated carbon were studied in a batch system. Various operation parameters such as adsorbent dosage, pH, initial concentration, contact time and temperature were optimized. Experimental equilibrium adsorption data were analyzed by Langmuir and Freundlich adsorption isotherm. The equilibrium process was described well by Freundlich isotherm model. From determined separation factor (1/n), adsorption of metanil yellow by granular activated carbon could be employed as effective treatment method. By analysis of kinetic experimental data, the adsorption process were found to confirm to the pseudo second order model with good correlation and the adsorption rate constant ($k^2$) decreased with increasing initial concentration. Thermodynamic parameters like activation energy, change of free energy, enthalpy, and entropy were also calculated to predict the nature adsorption in the temperature range of 298~318 K. The activation energy was determined as 23.90 kJ/mol. It was found that the adsortpion of metanil yellow on the granular activated carbon was physical process. The negative Gibbs free energy change (${\Delta}G=-2.16{\sim}-6.55kJ/mol$) and the positive enthalpy change (${\Delta}H=+23.29kJ/mol$) indicated the spontaneous and endothermic nature of the adsorption process, respectively.

Characteristics on the Permeation of Protein Through Membrane of Ultrafiltration Reactor (한외여과막 반응기에서 단백질의 막 투과특성)

  • 변희국;전유진;김세권
    • Membrane Journal
    • /
    • v.8 no.1
    • /
    • pp.42-49
    • /
    • 1998
  • Effects of operating time, pH, temperature, concentration and addition of proteolytic enzyme on permeate flux for the ultrafiltration of gelatin and bovine serum albumin(BSA) solutions were studied. The results showed that permeate flux of gelatin solution was maintained almost constant during the operating time, and that of BSA solution was decreased to 66% of the initial value after 40 min operation. The permeate flux of gelatin solution was increased by increasing temperature. The permeate flux of BSA solution was constant in the temperature range of 30~$50{\circ}C$, but increased at $60{\circ}C.$. The permeate fluxes of gelatin and BSA solution showed minimum values near the isoelectric point of pH 5.0. The permeate fluxes of 1%(w/v) and 6% gelatin solution were $43.0l/m^2\cdot hr$ and $13.5l/m^2\cdot hr$, respectively. Those of 1% and 4% BSA solution were $33.0l/m^2\cdot hr$ and $14.0l/m^2\cdot hr$, respectively. The permeate fluxes of gelatin and BSA solutions were decreased to 68.6% and 57.6% of their initial values by increasing their concentration, respectively. The permeate fluxes of gelatin and BSA solutions were enhanced by 30% with the addition of proteolytic enzyme.

  • PDF

Ocean Surface Winds Over the Seas Around Korea Measured by the NSCAT(NASA Scatterometer) (NSCAT (NASA Scatterometer)에 의한 한국근해의 해상풍)

  • 이동규
    • Korean Journal of Remote Sensing
    • /
    • v.14 no.1
    • /
    • pp.37-52
    • /
    • 1998
  • The NSCAT(NASA Scatterometer) carried by the japanese Advanced Earth Observing Satellite(ADEOS) was the first high resolution(25 km) device for the direct wind measurement over the ocean. Even it was ceased to operate in lune of 1977 because of the power failure, it gave the first opportunity to the marine meteorologists to study the direct measured ocean wind during its 9 months of operation, especially around Korea. This study is to show monthly mean ocean wind and wind stress curl fields around Korea from January, 1997 to June, 1997. Mean ocean winds in January are predominantly northwesterly and the strongest wind(12 m/s) is found near Vladivostok. The winds in the western East Sea are strongly inf1uenced by the mountain range in Korea and these topographically influenced winds make about five times larger wind stress curl fields than previous estimates based on the weather maps. The calculation of Sverdrup transport in the East Sea shows the possibility of the directional change of the East Korean Cold Current from southward to northward direction caused by the winter wind. The downwelling area near North Korea has maximum estimated speed of 45 m in january and this wind induced downwelling makes good condition for the formation of Intermediate East Sea Water together with vigorous mixing by the strong wind.

Characteristics of Ocean Scanning Multi-spectral Imager(OSMI) (Ocean Scanning Multi-spectral Imager (OSMI) 특성)

  • Young Min Cho;Sang-Soon Yong;Sun Hee Woo;Sang-Gyu Lee;Kyoung-Hwan Oh;Hong-Yul Paik
    • Korean Journal of Remote Sensing
    • /
    • v.14 no.3
    • /
    • pp.223-231
    • /
    • 1998
  • Ocean Scanning Multispectral Imager (OSMI) is a payload on the Korean Multi-Purpose SATellite (KOMPSAT) to perform worldwide ocean color monitoring for the study of biological oceanography. The instrument images the ocean surface using a whisk-broom motion with a swath width of 800 km and a ground sample distance (GSD) of less than 1 km over the entire field-of-view (FOV). The instrument is designed to have an on-orbit operation duty cycle of 20% over the mission lifetime of 3 years with the functions of programmable gain/offset and on-orbit image data storage. The instrument also performs sun calibration and dark calibration for on-orbit instalment calibration. The OSMI instrument is a multi-spectral imager covering the spectral range from 400 nm to 900 nm using a Charge Coupled Device (CCD) Focal Plane Array (FPA). The ocean colors are monitored using 6 spectral channels that can be selected via ground commands after launch. The instrument performances are fully measured for 8 basic spectral bands centered at 412, 443, 490, 510, 555, 670, 765 and 865 nm during ground characterization of instalment. In addition to the ground calibration, the on-orbit calibration will also be used for the on-orbit band selection. The on-orbit band selection capability can provide great flexibility in ocean color monitoring.

A Study on the Implementation of an All-IP Train Communication Network Using Plastic Optical Fiber (플라스틱 광섬유를 이용한 All-IP 열차통신네트워크 구현에 관한 연구)

  • Kim, Dongha;Lee, Soyoung;Choi, Kyuhyong
    • Journal of the Korean Society for Railway
    • /
    • v.16 no.3
    • /
    • pp.189-195
    • /
    • 2013
  • Recent trains have broadband train communication networks to improve train operation safety and to provide passengers with multimedia services. Compared to glass optical fiber, plastic optical fiber (POF) has a large diameter; it also provides the good durability and maintainability necessary to railway applications. This paper suggests an All-IP broadband train communication network that connects all devices in the train through a POF interface. Performance tests according to Korean railroad standards shows that this POF interface is usable in the range of vibration and temperature conditions encountered in trains. A dedicated Layer-2 switch with the POF interface is developed for the construction of the All-IP train communication network. A prototype 1Gbps train communication network was set up in a trial-run of train on a metro line using the developed Layer-2 switch and POF. On-track tests indicated the feasibility of the POF train communication network. POF has an additional advantage of economic feasibility, and it is expected to start a trend toward broadband train communication networks using POF.

Evaluation of the Large Scale Petroleum-Contaminated Site for the Remediation of Landfarming (대규모 유류오염부지에 적용된 토양경작법의 정화효율 평가)

  • Ju, Weon-Ha;Choi, Sang-Il;Kim, Jong-Min;Kim, Bo-Kyung;Kim, Sung-Gyoo;Park, Sang-Hean
    • Journal of Soil and Groundwater Environment
    • /
    • v.14 no.4
    • /
    • pp.15-22
    • /
    • 2009
  • The remediation efficiency for a large scale petroleum-contaminated site was evaluated by using the Engineered Land-farming system which was consists of the following parameters; moisture & nutrient injector data, blower system, HDPE sheet and sump system. To enhance the degradation ability in the early stage, main nutrients such as nitrogen (N) and phosphorus (P) were adjusted for the site condition. As a result of the periodic tilling process, the concentration of contaminated soil was decreased to 348 mg/kg, which was lower than 500 mg/kg (regal standards) while satisfying remediation Efficiency of 82% (the maximum concentration of 1,893 mg/kg). The appropriate temperature range for an active operation was investigated between $28.9{\sim}35.6^{\circ}C$. For the contaminated soils having different initial concentration, the TPH (Total Petroleum Hydrocarbons) concentration was decreased evenly along with the CFU (Colony Forming Unit), moisture content and contaminant concentration after 38days of gratifying the legal standards of under 500 mg/kg.

Temporomandibular joint disc plication with MITEK mini anchors: surgical outcome of 65 consecutive joint cases using a minimally invasive approach

  • Lee, Bu-Kyu;Hong, Jun Hee
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.42
    • /
    • pp.14.1-14.11
    • /
    • 2020
  • Background: The purpose of this study is to introduce our modified disc plication technique using MITEK mini anchors and to evaluate the clinical outcome for patients with internal derangement (ID) of the temporomandibular joint (TMJ). Patients and methods: We evaluated 65 joints in 46 patients, comprised 32 women and 14 men, who first visited the Asan Medical Center from December 2012 to December 2016. The age of the patients ranged from 14 to 79 years, with a mean age of 36.6 years. The patients presented with joint problems including pain, joint noise, and mouth opening limitation (MOL). Patients who met our inclusion criteria underwent unilateral or bilateral disc repositioning surgery with our minimally invasive disc plication technique using MITEK mini anchors and No. 2-0 Ethibond® braided polyester sutures. The variables taken into account in this study were the range of maximum mouth opening (MMO), painful symptoms (evaluated with the visual analog scale, VAS), and the type of noise (click, popping, crepitus) in the TMJ. Results: Preoperative examination revealed painful symptoms in 50.7% (n = 35) of the operated joints (n = 69) and the presence of clicks in 56.5% (n = 39). Postoperative examination revealed that 4.3% (n = 3) of the operated joints had painful symptoms with lower intensity than that in the preoperative condition. Additionally, 17.4% (n = 12) had residual noise in the TMJ, among which two were clicking and the other 10 had mild crepitus. The intensity of the postoperative residual noise was significantly decreased in all cases compared to that in the preoperative condition. Among patients with MOL below 38 mm (n = 18), the mean MMO was 31.4 mm preoperatively and 44.2 mm at 6 months postoperatively, with a mean increase of 13.8 mm. A barely visible scar at the operation site was noted during the postoperative observation period, with no significant complications such as facial palsy or permanent occlusal disharmony. Conclusion: Subjective symptoms in all patients improved following the surgery. TMJ disc plication using MITEK mini anchors with our minimally invasive approach may be a feasible and effective surgical option for treating TMJ ID patients who are not responsive to conservative treatment.

Electromagnetic Wave and EMF Attenuation by Shielding Materials in home appliances (가전제품 전자파 현황 및 차폐재에 의한 감쇄 효과)

  • Cho, Jae-Cheol;Park, Jae-Hwan
    • Asia-pacific Journal of Multimedia Services Convergent with Art, Humanities, and Sociology
    • /
    • v.9 no.6
    • /
    • pp.711-718
    • /
    • 2019
  • Spectrum analyzer and electromagnetic field meter were used to investigate the EM generation behaviour in different types of home electrical appliances. During microwave oven operation, the EM power measured at a point 30cm apart was measured in the range of 8~11mW/㎡, the strength of the low frequency magnetic field was 60~80mG and the electric field strength was measured at 150~160V/m. For smart phone wireless charging pad, it was measured at an electromagnetic power of 0.4mW/㎡, an electric field of 160 V/m and a magnetic field of 1mG at a point 10cm away. For microwave oven and wireless charging pad, if used within 10cm, the size of the electric field has been measured at a large value that exceeds the human body protection standard and may be hazardous to humans. On the other hand, home appliances such as TVs, hairdryers and refrigerators all showed very low levels of electromagnetic waves, electric fields and magnetic fields, with no harmful effects seen. For electromagnetic shielding, the metal Cu fabric and metal foil had a high level of EM shielding, while polymer films had a low EM shielding characteristic.

Preparation of Seaweed Calcium Microparticles by Wet-grinding Process and their Particle Size Distribution Analysis (초미세습식분쇄공정의 공정변수에 따른 해조칼슘의 입자크기 분석)

  • Han, Min-Woo;Youn, Kwang-Sup
    • Food Engineering Progress
    • /
    • v.13 no.4
    • /
    • pp.269-274
    • /
    • 2009
  • The main objective of this study was to establish optimum condition of wet grinding process for manufacturing microparticulated seaweed calcium. Process parameters such as concentration of forming agent, rotor speed, bead size, feed rate, and grinding time were adapted during wet-grinding of seaweed calcium. The particle size range of the raw seaweed calcium was 10-20 $\mu$m. The calcium particles were reduced to under 1 $\mu$m as nano scale after grinding. Gum arabic was suitable for forming agent and 5%(w/v) concentration was the most effective in grinding efficiency. A wet-grinding process operated at 4,000 rpm rotor speed, 0,4 mm bead size, and 0.4 L/hr feeding rate, respectively, produced less than 600 mm(>>90%)-sized particles. In batch systems, 8 cycles of grinding showed higher efficiency, but 20 min of grinding time in continuous processing was more efficient to reduce particle size than the batch processing. Based on the result, the optimum conditions of the wet grinding process were established: operation time of 20 minutes, rotor speed of 4,000 rpm, bead size of 0.4 mm, feed rate of 40 mL/min and 30% mixing ration with water. The size of the resulting ultra fine calcium particles ranged between 40 and 660 mm.