• Title/Summary/Keyword: Operation guideline

Search Result 409, Processing Time 0.039 seconds

A Study on Establishment of Technical Guideline of the Installation and Operation for the Biogas Utilization of Transportation and City Gas: Design and Operation Guideline (고품질화 바이오가스 이용 기술지침 마련을 위한 연구(III): 도시가스 및 수송용 - 기술지침(안) 중심으로)

  • Moon, HeeSung;Kwon, Junhwa;Park, Hoyeon;Jeon, Taewan;Shin, Sunkyung;Lee, Dongjin
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.27 no.2
    • /
    • pp.67-73
    • /
    • 2019
  • In this study, to optimize the production and utilization of biogas for organic waste resources, the precision monitoring of on-site facilities and the energy balance by facility were analyzed, and the solutions for field problems were investigated, and the design and operation guidelines for pretreatment facilities and generators were presented. Gas pre-treatment is required to solve frequent failures and efficiency degradation in operation of high quality refining facilities, and processing processes such as desulfurization, dehumidification, deoxidization, dust treatment, volatile organic compounds, etc. Since these processes are substances that are also eliminated from the high-quality process, quantitative guidelines are not presented in the gas pretreatment process, but are suggested to operate during the processing process as a qualitative guideline. In particular, dust, siloxane, and volatile organic compounds are the main cause of frequent failure of high-quality processes if they are not removed from the gas pretreatment process. Design of the biogas high-quality process. The operation guidelines provide quality standards [Methane content (including propane) of 95% or more] with 90% or more utilization of the total gas generation, two systems, and a margin of 10% or more. It also proposed installing gas equalization tank, installing thermal automatic control system for controlling equalization of auxiliary fuel, installing dehumidification device at the back of high quality for removing moisture generated in the process of gas compression, installing heat-resisting facilities to prevent freezing of facilities in winter and reducing efficiency, and installing membrane facilities in particular.

Review Guideline of Railway Standard Operation Procedures for Emergency Response (철도 비상대응절차서 검토기준)

  • Sim, Young-Rok;Suh, Sang-Moon;Park, Geun-Ok
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.551-558
    • /
    • 2007
  • This paper presents a review guideline for evaluating SERPs(standard emergency response procedure) in rail accidents. In order to develope it, design elements of the SERPs, that impact the performance of emergency responding personnel, were identified. Then several review guidelines and standards, being used in other industries including nuclear domain, were surveyed. Finally, the review guides and criteria corresponding to those elements were derived from the survey.

  • PDF

GOOD LABORATORY PRACTICE -PRINCIPLES AND PRESENT STATUS IN JAPAN

  • Omori, Yoshihito
    • Toxicological Research
    • /
    • v.1 no.1
    • /
    • pp.31-41
    • /
    • 1985
  • The Japanese Good Laboratory Practice (GLP) Standard on Drugs was finalized as a guideline and implemented in April, 1983. This standard is intended to ensure the quality and integrity of the data from nonclinical toxicity studies submitted to the Ministry of Health and Welfare in support of applications for approval to manufacture or import new drugs or to be used in the reevaluation of previously approved drugs. The standard includes a guideline for organizational matters, personnel, facility, equipment, testing operation, documentation and conduct of studies. Principles and influences of implementation of Japanese GLP will be discussed briefly in comparison with foreign GLPs.

  • PDF

A Study on Establishment of Technical Guideline of the Installation and Operation for the Efficient Bio-gasification Facility of Food Wastes (III) - Final Items of Technical Guideline of the Installation and Operation (음식물류폐기물의 고효율 바이오가스화를 위한 설계 및 운전기술지침 마련 연구(III) - 설계 및 운전 지침(안) 중심으로)

  • Lee, Dongjin;Gang, Junkyu;Lee, Suyoung;Kim, Kiheon;Bae, Jisu
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.23 no.3
    • /
    • pp.11-22
    • /
    • 2015

The 3rd National Conference Of Professional engineers - On The Problems and Guideline of The Air Quality Model Operation (제3회 전국기술사대회 특집(환경) - 대기모델 운영의 문제점 및 가이드라인 설정방향)

  • Park, Sun-Hwan
    • Journal of the Korean Professional Engineers Association
    • /
    • v.42 no.4
    • /
    • pp.40-44
    • /
    • 2009
  • The analysis of air quality model applied for EIA in Korea indicates that ISCST3 and CALINE3 dominate the model, and it causes the problem that regional and business characteristics are not taken into account. To solve this problem, it appears necessary to build guideline of the air quality model operation. First of all, to implement the above plan we need to categorize the site into simple and complex terrain, coast to consider regional characteristics, and the sources of pollutants into point/area/line as well. To make the procedure more efficient with reduced time and less cost, we are to apply screening model for prelimninary work of the suggested model.

  • PDF

Selection of Coupling Factor for Minimum Inductor Current Ripple in Multi-winding Coupled Inductor Used in Bidirectional DC-DC Converters

  • Kang, Taewon;Suh, Yongsug
    • Journal of Power Electronics
    • /
    • v.18 no.3
    • /
    • pp.879-891
    • /
    • 2018
  • A bidirectional dc-dc converter is used in battery energy storage systems owing to the growing requirements of a charging and discharging mode of battery. The magnetic coupling of output or input inductors in parallel-connected multi modules of a bidirectional dc-dc converter is often utilized to reduce the peak-to-peak ripple size of the inductor current. This study proposes a novel design guideline to achieve minimal ripple size of the inductor current under bidirectional power flow. The newly proposed design guideline of optimized coupling factor is applicable to the buck and boost operation modes of a bidirectional dc-dc converter. Therefore, the coupling factor value of the coupled inductor does not have to be optimized separately for buck and boost operation modes. This new observation is explained using the theoretical model of coupled inductor and confirmed through simulation and experimental test.

Guidelines on the Operation Phases of Manual Material Handling Tasks Through Literature Reviews

  • Lee, Kyung-Sun;Jung, Myung-Chul
    • Journal of the Ergonomics Society of Korea
    • /
    • v.36 no.4
    • /
    • pp.325-341
    • /
    • 2017
  • Objective: The purpose of this study is to suggest the guidelines of operation phases to minimize injuries and musculoskeletal disorders in manual material handling (MMH) tasks through literature reviews. The guidelines are presented as the preparing phase, lifting phase, carrying phase, and lowering phase. Also, we summarized the non-numerical general guidelines for MMH tasks. Background: Manual material handling is still a main cause to musculoskeletal disorders. Method: Procedures of a literature review are classified into database selection, keyword search, title review, abstract review related to literature selection, guideline review and arrangement. A total 48 papers and books were analyzed in detail by title and abstract reviews. Results: In the preparing phase, we suggested the basic conditions in MMH, preparing procedure, clothing and protective equipment, and education. In the lifting and carrying phases, we recommended maximal acceptable weight by frequency and body posture. In the lowering phase, we suggested the lowest weight and safety body postures. Finally, we recommended general guidelines and guideline items for MMH. General guidelines are presented to suggest worker selection, technical education, and work design parts. Conclusion: We suggested the guidelines on the four operation phases of MMH tasks such as preparing, lifting, carrying, and lowering phases. Application: The findings of this study can be utilized as guidelines for proactive recommendations according to workers in MMH tasks.

Analysis of Singapore's BIM tender documents for the development of infrastructure BIM guidelines in Korea (국외 BIM 발주지침 분석을 통한 국내 토목 분야 BIM 가이드라인 개발 방향 제시에 관한 연구 - 싱가폴 토목 사업 과업지시서를 중심으로-)

  • Koo, Bon-Sang;Ok, Hyun;Yu, Young-Su;Jung, Rae-Kyu
    • Journal of KIBIM
    • /
    • v.8 no.2
    • /
    • pp.19-28
    • /
    • 2018
  • Recent increase in the interest and adoption of BIM for infrastructure projects has created a need for formal BIM guidelines in the civil engineering domain. Currently a BIM guideline has been developed in Korea exclusively for the road sector. However, the guideline has gaps in the specification of how BIM models should be generated, managed and applied for maximum effect in projects. This study reviewed the guidelines and tender documents of Singapore to determine potential improvements to adopt in Korea. Results showed that Korea's guideline should focus more on process integration as to stipulating BIM deliverables, encourage a common data environment, clearly distinguish between compulsory and selective BIM applications, and require data and models that can be leveraged in the operation phase of the facility.

A Study on Developing the Guideline of Risk Management utilizing BCP technique for Airport Corporation (공항전문기업의 BCP기법을 활용한 위기대응 가이드라인 개발에 관한 연구)

  • Seo, Byung Seok;Shin, Do Hyoung
    • Journal of the Korea Safety Management & Science
    • /
    • v.17 no.2
    • /
    • pp.67-78
    • /
    • 2015
  • The purpose of the establishment of corporation's Business Continuity Plan(BCP) is to maintain corporations' own business and establish the response plan in order to resume operation in a short time period when crisis situations occur due to natural disaster and human error. This study has presented all types of procedures and criteria which are needed to establish the airport crisis response system in order to maintain the business continuity by utilizing BCP technique. Basically the risk response procedures must be established in the process of (1) preparation stage, (2) plan development stage, (3) documentation stage, (4) test & maintenance stage. The guideline has been suggested that each stage must be carried out in the sequence of Policy & Planning Responsibility, Business Impact Analysis, Recovery Strategy & Plans, Emergency Plan & SOP, Training Awareness and Maintenance & Review

Research on Risk-Based Piping Inspection Guideline System in the Petrochemical Industry

  • Tien, Shiaw-Wen;Hwang, Wen-Tsung;Tsai, Chih-Hung
    • International Journal of Quality Innovation
    • /
    • v.7 no.2
    • /
    • pp.97-124
    • /
    • 2006
  • The purpose of this research is to create an expert risk-based piping system inspection model. The proposed system includes a risk-based piping inspection system and a piping inspection guideline system. The research procedure consists of three parts: the risk-based inspection model, the risk-based piping inspection model, and the piping inspection guideline system model. In this research procedure, a field plant visit is conducted to collect the related domestic information (Taiwan) and foreign standards and regulations for creating a strategic risk-based piping inspection and analysis system in accordance with the piping damage characteristics in the petrochemical industry. In accordance with various piping damage models and damage positions, petrochemical plants provide the optimal piping inspection planning tool for efficient piping risk prediction for enhancing plant operation safety.