• Title/Summary/Keyword: Operation data

Search Result 9,753, Processing Time 0.04 seconds

Analysis of Fluidization in a Fluidized Bed External Heat Exchanger using Barracuda Simulation (바라쿠다 시뮬레이션을 이용한 유동층 외부 열교환기의 유동해석)

  • Lee, Jongmin;Kim, Dongwon;Park, Kyoungil;Lee, Gyuhwa
    • Korean Chemical Engineering Research
    • /
    • v.58 no.4
    • /
    • pp.642-650
    • /
    • 2020
  • In general, the circulation path of the fluidized particles in a CFB (Circulating Fluidized Bed) boiler is such that the particles entrained from a combustor are collected by a cyclone and recirculated to the combustor via a sealpot which is one of non-mechanical valves. However, when a fluidized bed heat exchanger (FBHE) is installed to additionally absorb heat from the fluidized particles, some particles in the sealpot pass through the FBHE and then flow into the combustor. At this time, in the FBHE operated in the bubbling fluidization regime, if the heat flow is not evenly distributed by poor mixing of the hot particles (800~950 ℃) flowing in from the sealpot, the heat exchanger tubes would be locally heated and then damaged, and the agglomeration of particles could also occur by formation of hot spot. This may affect the stable operation of the circulating fluidized bed. In this study, the unevenness of heat flow arising from structural problems of the FBHE of the domestic D-CFB boiler was found through the operating data analysis and the CPFD (Computational Particle Fluid Dynamics) simulation using Barracuda VR. Actually, the temperature of the heat exchanger tubes in the FBHE showed the closest correlation with the change in particle temperature of the sealpot. It was also found that the non-uniformity of the heat flow was caused by channeling of hot particles flowing in from the sealpot. However, it was difficult to eliminate the non-uniformity even though the fluidizing velocity of the FBHE was increased enough to fluidize hot particles vigorously. When the premixing zone for hot particles flowing in from the sealpot is installed and when the structure is changed through the symmetrization of the FBHE discharge line for particles reflowing into the combustor, the particle mixing and the uniformity of heat flow were found to be increased considerably. Therefore, it could be suggested that the structural modification of the FBHE, related to premixing and symmetric flow of hot particles, is an alternative to reduce the non-uniformity of the heat flow and to minimize the poor particle mixing.

The Long-term Results of a Modified Maze Procedure with Using Cryoablation (냉동 절제를 이용한 변형된 Maze술 식의 중장기 결과)

  • Park, Kwon-Jae;Woo, Jong-Soo;Bang, Jung-Hee
    • Journal of Chest Surgery
    • /
    • v.41 no.6
    • /
    • pp.710-717
    • /
    • 2008
  • Background: Atrial fibrillation is associated with several complications such as cerebro-vascular accidents and peripheral arterial embolism. Most of the patients who have this arrhythmia chronically feel their heart beating and so they are frightened; therefore, the quality of a patient's life is decreased. The purpose of this article is to determine the long term results of a modified Maze procedure and the factors that influence the success of the procedure. Material and Method: This study enrolled 88 patients who underwent the modified Maze with using cryoablation between June, 2001 and February, 2007. The 88 consecutive patients were divided into two groups ac cording to how the pulmonary veins were isolated, that is, with or without cryoablation. There were 58 patients who were isolated by cutting and sewing in the right pulmonary veins and by cyroablation in the left pulmonary veins in group 1 (group 1, n=58), and 30 patients who underwent isolation by cryoablation in the right & left pulmonary veins were placed in group 2 (group 2, n=30). The ECG was checked at discharge to determine the sinus conversion rate and we followed up the patients to determine whether or not the patients maintained sinus rhythm. We also checked the ECG at the last visit to determine the patients' heart rhythm. Result: The mean follow up time was $44.3{\pm}19.2$ months. At discharge, 72.4% of the patients in group 1 were in proper sinus rhythm and 66.7% of the patients in group 2 were in proper sinus rhythm. At the last follow up, 81% of the patients in group 1 were in normal sinus rhythm and 60% of the patients in group 2 were in normal sinus rhythm. When we analyzed the data via the Kaplan-Meier method, 86.5% of the patients were free from atrial fibrillation (% free from AF) at 1 year, 80% of the patients were free from atrial fibrillation at 5 year in group 1 and 70% of the patients were free from atrial fibrillation at 1 year and 51 % of the patients in group 2 were free from atrial fibrillation at 5 year. Conclusion: The modified Maze technique using cryoablation was a simple and effective procedure. But the success rate of the Maze technique using cryoblation is lower than that of the standard Maze III. The method using cryoablation shorten the operation time, but we must conduct more studies to get a better result of the modified Maze technique with using cryoablation.

The Effects of Additional Tetracycline Pleurodesis during Thoracoscopic Procedures for Treating Primary Spontaneous Pneumothorax (일차성 자연 기흉의 흉강경 수술 시 추가로 시행한 Textracycline 흉막 유착술의 효용)

  • Lee, Hyeon-Woong;Lee, Jae-Ik;Kim, Keun-Woo;Park, Kook-Yang;Park, Chul-Hyun;Hyun, Sung-Youl;Jeon, Yang-Bin;Choi, Chang-Hyu
    • Journal of Chest Surgery
    • /
    • v.41 no.6
    • /
    • pp.729-735
    • /
    • 2008
  • Background: This study was performed to evaluate the safety and efficacy of performing additional tetracycline pleurodesis during the thoracoscopic treatment of primary spontaneous pneumothorax. Material and Method: Between March 2004 and December 2007, 91 cases of primary spontaneous pneumothorax were treated by video-assisted thoracoscopic surgery. The thoracoscopic procedures included resection of the blebs and mechanical pleurodesis by scrubbing the parietal pleura. For 27 cases (Tetracycline group, group I), 20 mg/kg tetracycline was instilled into the pleural space through a trocar before closing the chest. The control group (group II) consisted of 64 cases of primary spontaneous pneumothorax for which the same thoracoscopic procedures alone were performed during the same study period. Result: There was no significant difference between the two groups in terms of the demographic data, the operative findings and the operation time. The percentage of cases that needed intravenous analgesics and the duration of intravenous analgesics were comparable in both groups. There was no significant difference in the duration of air leaks and complications between the two groups. The patients treated with tetracycline pleurodesis had a longer period of postoperative chest drainage (4.2 days vs 3.5 days, respectively, p=0.03) and hospitalization (5.0 days vs 4.0 days, respectively, p=0.006). During the follow up period, the ipsilateral recurrence rate was much lower for the patients who were treated with tetracycline pleurodesis (0% vs 10.9%, respectively, p=0.099), and freedom from recurrence tended to be more favorable for group I (p=0.077), although this was not statistically significant. Conclusion: Additional tetracycline pleurodesis during thoracoscopic treatment for primary spontaneous pneumothorax caused prolongation of chest drainage and a prolonged hospital stay. However, further investigations are needed because tetracycline pleurodesis can be performed safely without serious complications and it showed a distinct tendency to reduce the rate of recurrence.

Analysis of Long-Term Variation in Marine Traffic Volume and Characteristics of Ship Traffic Routes in Yeosu Gwangyang Port (여수광양항 해상교통량의 장기변동 및 통항 특성)

  • Kim, Dae-Jin;Shin, Hyeong-Ho;Jang, Duck-Jong
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.26 no.1
    • /
    • pp.31-38
    • /
    • 2020
  • The characteristics of ship traffic routes and the long term fluctuation in marine traf ic volume of the incoming and outgoing routes of the Yeosu Gwangyang Port were analyzed using vessel traffic data from the past 22 years and a real-time vessel traffic volume survey performed for 72 hours per year, for three years, between 2015 and 2017. As of 2017, the number of vessels passing through Yeosu Gwangyang Port was about 66,000 and the total tonnage of these ships was about 804,564 thousand tons, which is a 400 % increase from the 189,906 thousand tons shipped in 1996. Specifically, the dangerous cargo volume was 140,000 thousand tons, which is a 250 % increase compared to 1996. According to the real-time vessel traffic volume survey, the average daily number of vessels was 357, and traf ic route utilization rates were 28.1 % in the Nakpo sea area, 43.8 % in the specified sea area, and the coastal area traf ic route, Dolsan coastal area, and Kumhodo sea area showed the same rate of 6.8 %. Many routes meet in the Nakpo sea area and, parallel and cross passing were frequent. Many small work vessels entered the specific sea area from the neighboring coastal area traffic route and frequently intersected the path of larger vessels. The anchorage waiting rate for cargo ships was about 24 %, and the nightly passing rate for dangerous cargo ships such as chemical vessels and tankers was about 20 %. Although the vessel traffic volume of Yeosu Gwangyang Port increases every year, the vessel traffic routes remain the same. Therefore, the risk of accidents is constantly increasing. The route conditions must be improved by dredging and expanding the available routes to reduce the high risk of ship accidents due to overlapping routes, by removing reefs, and by reinforcing navigational aids. In addition, the entry and exit time for dangerous cargo ships at high-risk ports must be strictly regulated. Advancements in the VTS system can help to actively manage the traffic of small vessels using the coastal area traffic route.

The Relationship with Electronic Trust, Web Site Commitment and Service Transaction Intention in Public Shipping B2B e-marketplace (해운 B2B e-marketplace의 전자적 신뢰, 사이트몰입 및 서비스 거래의도와의 관계성)

  • Kim, Yong-Man;Kim, Seog-Yong;Lee, Jong-Hwan;Shim, Gyu-Yeol
    • Journal of Global Scholars of Marketing Science
    • /
    • v.17 no.4
    • /
    • pp.113-139
    • /
    • 2007
  • This study aims to, looking from a standpoint of network, has investigated the shipping industry's B2B e-marketplace, the characteristics that can earn electronic trust from the users, and characteristics of the web-site. It has examined the mechanism whereby electronic trust be earned and how it affects web-site involvement and service transaction intention. Ultimately, The study attempts to make proposals whereby such trust can lead for a cooperative trading community in the shipping industry's B2B e-marketplace The Covalence structural equation modeling was designed and empirically tested for the shipping industry's B2B e-marketplace. The shipping industry employees were given questionnaires and data were analyzed. Except for perceived security of the three characteristic factors on the web-site, the perceived site quality and characteristics factors in operation only affected co-variables. Transaction Fairness was determined to be the most important factor among exogenous factors increasing electronic trust. With regards to transaction rules, if a transaction is beneficial only to one side, then no long term transaction will not take place. If the concerned parties properly recognize that transaction fairness is crucial to electronic transaction, then it will enormously contribute to successful operations of shipping e-marketplace. Also, Perceived efficiency in transaction also affects electronic trust. This reduces transaction costs and speeds up and simplifies the transaction process. It has reduced greater time and costs than existing off-line transaction, and would positively affect electronic trust. By making an open forum for participants to obtain information for transaction, they can gather useful information, and at the same time, the web-site operator can provide information, which, in turn, will increase electronic trust in electronic transaction. Furthermore, such formation of trust in electronic transaction influences shipping companies in such a way that they will want to continuously participate in the transaction, raising web-site involvement. The result of increased trust is that shipping companies in the future will do business with each other and form a foundation for continuous transactions amongst themselves. Consequently, the formation of trust in electronic transaction greatly influences web-site involvement and service transaction intention. The results of the study have again proved that in order to maintain continuous business relationship with the current clients, electronic trust in virtual space, which operates the shipping industry's B2B e-marketplace, is important for the interested parties.

  • PDF

Surgical Treatment of Pulmonary Atresia with Intact Ventricular Septum -Effect of the size of tricuspid valve annulus on the surgical outcome- (영아기에 발견된 심실중격이 온전한 폐동맥 폐쇄증의 외과적 수술요법 술전 삼첨판륜 크기 가 수술 결과에 미치는 영향)

  • 이정렬;윤태진
    • Journal of Chest Surgery
    • /
    • v.29 no.10
    • /
    • pp.1081-1089
    • /
    • 1996
  • Pulmonary atresia with intact ventricular septum has continued to have a high surgical mortality and morbidity. This mAy attribute to the non-uniformity of the anomaly. We reviewed a total of 34 infants with pulmonary atresla and intact ventricular septum managed in this hospital between 1987 and 1995. Mean age and body weight were 57.2 (range, 3-208) days and 4.1 (range, B.3∼6.8) kg. The preoperative Z-value of the diameter of the tricuspid valve was less than -2 in 85.2% of patients and less than -4 in 33. 3% . It is well correlated w th right ventricular cavity size (n=27. r10.68, p< 0.05). Coronary artery-right ventricular fistulas were identified in 3 patients, and right ventricular dependency was suspected in 1 Over All hospital mortality was 23.5%(8/34), although it decreased to 16.6%(4124) in 1990s. Subsequent procedures were performed in 6 patients between 3 days and 58 months after Initial palliation : one bidirectional cavopulmonary shunt and 1 Fontan operation after systemic-pulmonary shunt, 3 transannular patch + atrial septal defect closure and 1 additional systemic-pulmonary shunt after polmonary valvectomy or valvotomy. Changes of Z-values of the diameter of tricuspid valve have been followed up in 11 patients between 1 and 66 months postoperatively. Z-values were increased In 5 out of 8 transannular right ventriculAr outflow tract enlargement group and in 1 out of 3 pulmonary valvectomy or valvotomy group. Our data suggest that tailoring a treatment to right ventricular cavity size and coronary anom lies may improve the surgical outcome. A Z-value of the tricuspid valve diameter could be used.

  • PDF

Functional Result of Limb Salvage Surgery with Tumor Prosthesis for Osteosarcoma of Proximal Tibia (근위 경골 골육종의 종양대치물을 이용한 사지 구제술 후의 기능 평가)

  • Bahk, Won-Jong;Sohn, Jong-Min;Chung, Yang-Guk;Kang, Yong-Koo
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.7 no.4
    • /
    • pp.139-143
    • /
    • 2001
  • Purpose : Limb salvage for osteosarcoma of proximal tibia is challenging problem due to difficulties in mobilizing or retracting the main neurovascular structure, inadequate soft tissue coverage, and unsolved problem of patellar tendon reattachment to endoprosthesis. The authors analyzed the functional result of limb salvage using tumor prosthesis with medial gastrocnemius rotation plasty for osteosarcama of the proximal tibia. Materials and Methods : Eleven patients with histologically proven osteosarcoma of the proximal tibia, treated with adjuvant and neoadjuvant chemotherapy and limb salvage operation with tumor prosthesis between January 1992 and December 1998 at our Medical Center, were selected. There were 6 male and 5 female. Age ranged from 15 years to 23.7 years with an average of 23.7 years. Follow-up period ranged from 1 year to 4.5 years with an average of 2.5 years. The final functional result was evaluated using the method by ISOLS, 1993. The factors include pain, functional activities, emotional acceptance, use of external supports, walking ability and gait. Each of the factors has been scored from 0 to 5 depending on the appropriate description or data. The rating score is determined by dividing the individual factor scores into the total score and indicates percentage of normal function. Results : The overall functional result ranged from 53,3% to 86.7% with an average of 68.3% of normal function. In details, the averages were 82.5% for pain, 62.5% for functional activities, 67.5% for emotional acceptance, 77.5% for use of external supports, 62.5% for walking ability, and 57.5% for gait. The average range of motion of the knee joint was $5^{\circ}$ extension and $85^{\circ}$ flexion. Five patients have extension lag ranged from $5^{\circ}$ to $15^{\circ}$ with an average of $10^{\circ}$. Two patients suffered postoperative infection. One was treated with antibiotics injection only, but the other needed removal of the prosthesis and knee fusion. Both of them showed unsatisfactory result. C o n c l u s i o n : The overall functional result after limb salvage using tumor prosthesis with medial gastrocnemius rotational flap for osteosarcoma of the proximal tibia was relatively satisfactory in case of no postoperative infection. The patients were less satisfactory in functional activities, emotional acceptance and gait than pain, use of external supports due to limitation of motion and extension lag. More aggressive postoperative physical therapy and protection with brace for 6~9 months as well as surgical technique is mandatory for more satisfactory result.

  • PDF

Clinical Significance of MR Imaging for the Diagnosis and Treatment of Subungual Glomus Tumor in the Fingers (수지 조갑하 사구종의 진단 및 치료에서 자기 공명 영상의 임상적 의미)

  • Kim, Byoung-Suck;Kim, Woo-Sig;Han, Kyoung-Jin;Cho, Jae-Hyun;Lee, Kyi-Beom;Ha, Heon-Kyo;Kang, Shin-Young
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.7 no.1
    • /
    • pp.28-35
    • /
    • 2001
  • Purpose : Authors investigated the efficiency of preoperative MRI in suspicious glomus tumor and the clinical outcomes after marginal excision. Materials and Methods : In 10 cases of glomus tumors in the fingers, authors retrospectively analyzed the clinical data, including previous trauma, treatment history, preoperative symptoms, physical examination, plain radiography, MRI (9 cases), pathological findings and postoperative complications. Results : The patients had pain in 10 cases, tenderness in 9 cases, cold sensitivity in 3 cases and edema in one case. MRI showed low signal (3 cases) or iso-signal (5) intensity on T1 weighted image, high signal intensity (8) on T2 weighted image, and all the lesions were enhanced in gadolinium enhancement images. The exact locations of glomus tumors were median in 6 cases, lateral in 5, lateral fold in 2 and pulp in 3 in transverse section and nail bed in 5 cases and nail matrix in 5 in sagittal section. Marginal excision was performed by lateral approach in one case and transungual in 9 cases. Histologically, all 10 cases were composed of solid sheets of round cells interrupted by thin-walled blood vessels. Most of clinical symptoms were disappeared in all cases after operation. Nail deformity was found in one case, which was originated from nail matrix, however, there was no recurrence. Summary : Clinical symptom was the most impotant factor in diagnosis of glomus tumor in the fingers. However, preoperative MRIs were helpful in patients, who had obscure pain or prolonged clinical symptoms with suspicious glomus tumors. Preoperative MRI might be one of the most useful tools for establishing the exact diagnosis and detecting the location of glomus tumors, in spite of the relatively high expenses.

  • PDF

Study of Hydrodynamics and Reaction Characteristics of K-based Solid Sorbents for CO2 Capture in a Continuous System Composed of Two Bubbling Fluidized-bed Reactors (두 개의 기포유동층으로 구성된 연속장치에서 CO2 회수를 위한 K-계열 고체흡수제의 수력학적 특성 및 반응특성)

  • Kim, Ki-Chan;Kim, Kwang-Yul;Park, Young Cheol;Jo, Sung-Ho;Ryu, Ho-Jung;Yi, Chang-Keun
    • Korean Chemical Engineering Research
    • /
    • v.48 no.4
    • /
    • pp.499-505
    • /
    • 2010
  • In this study, hydrodynamics and reaction characteristic of K-based solid sorbents for $CO_2$ capture were investigated using a continuous system composed of two bubbling fluidized-bed reactors(1.2 m tall bed with 0.11 m i.d.). Potassium-based dry sorbents manufactured by the Korea Electric Power Research Institute were used, which were composed of $K_2CO_3$ of 35% for $CO_2$ absorption and supporters of 65% for mechanical strength. The continuous system consists of two bubbling fluidized-bed reactors, solid injection nozzle, riser, chiller, analyzer and heater for regeneration reaction. The minimum fluidizing velocity of the continuous system was 0.0088 m/s and the solid circulation rate measured was $10.3kg/m^2{\cdot}s$ at 1.05 m/s velocity of the solid injection nozzle. The $CO_2$ concentration of the simulated gas was about 10 vol% in dry basis. Reaction temperature in carbonator and regenerator were maintained about $70^{\circ}C$ and $200^{\circ}C$, respectively. Differential pressures, which were maintained in carbonator and regenerator, were about $415mmH_2O$ and $350mmH_2O$, respectively. In order to find out reaction characteristics of dry sorbents, several experiments were performed according to various experimental conditions such as $H_2O$ content(7.28~19.66%) in feed gas, velocity (0.053~0.103 m/s) of simulated gas, temperature($60{\sim}80^{\circ}C$) of a carbonator, temperature($150{\sim}200^{\circ}C$) of a regenerator and solid circulation rate($7.0{\sim}10.3kg/m^2{\cdot}s$). The respective data of operating variables were saved and analyzed after maintaining one hour in a stable manner. As a result of continuous operation, $CO_2$ removal tended to increase by increasing $H_2O$ content in feed gas, temperature of a regenerator and solid circulation rate and to decrease by increasing temperature of a carbonator and gas velocity in a carbonator.

Korea's Optimal Basket Exchange Rate : Thoughts on the Proper Operation of the Market Average Rate Regime (우리나라의 적정(適正)바스켓환율(換率) : 시장평균환율제도(市場平均換率制度)의 운용기준(運用基準) 모색(模索))

  • Oum, Bong-sung
    • KDI Journal of Economic Policy
    • /
    • v.12 no.1
    • /
    • pp.111-125
    • /
    • 1990
  • For the last several years, considerable criticism has been leveled against Korea's exchange rate management. While Korea was designated a currency manipulator by the U.S., domestically it is often complained that the won/dollar rate did not adequately reflect changes in Korea's export competitiveness and fluctuations in the exchange rates of major currencies. In view of this situation, Korea changed its exchange regime at the beginning of March this year from the dual currency basket system to a more flexible one, called a "market average rate regime". Under this new regime, the won rate is determined in the exchange market based upon the supply of and demand for foreign exchange and is allowed to freely fluctuate each day within a + 0.4 % range. This paper, first, seeks to evaluate Korea's exchange rate management under the dual basket regime of the 1980s, and then to construct an optimal currency basket for the won which could provide a proper indicator for exchange market intervention under the new market average rate regime. The analysis of fluctuations in the real effective exchange rate (REER) of the won indicates that the won rates in the 1980s failed not only to offset changes in relative prices between home and trading partner countries, but also to properly respond to variations in major exchange rates as further evidenced by sizable fluctuations in the nominal effective rates of the won. In other words, the currency basket regime which was adopted in 1980 for the stabilization of the REER of the won has not been operated properly, mainly because authorities often resorted to policy considerations in determining the won's rate. In the second part of the paper, an optimal currency basket for Korea is constructed, designed to minimize the fluctuations in the REER of the won without including policy considerations as a factor. It is recognized, however, that both domestic and foreign price data are not available immediately for the calculation of the REER. For this problem, the approach suggested by Lipschitz (1980) is followed, in which optimal weights for currencies in the basket are determined based upon the past correlation between price and exchange rates. When the optimal basket is applied to Korea since the mid-80s, it is found that the REER of the won could have been much more stable than it actually was. We also argue for the use of variable weights rather than fixed ones, which would be determined by the changing relationship between exchange rates and relative prices. The optimal basket, and the optimal basket exchange rate based on that basket, could provide an important medium- or long-term reference for proper exchange market intervention under the market average rate regime, together with other factors, such as developments in the current account balance and changes in productivity.

  • PDF