• 제목/요약/키워드: Operation control

검색결과 9,547건 처리시간 0.031초

승용차의 부분부하제어를 위한 스크류형 과급기 개발 (Development of a Screw Type Super-Charger for Part Load Control of Passenger Car)

  • 배재일;배신철
    • 대한기계학회논문집B
    • /
    • 제27권10호
    • /
    • pp.1427-1434
    • /
    • 2003
  • Turbo- or Super-charging has been used to boost engine power for Gasoline- and Diesel Engine since beginning of 20th century. So far turbo-charger has enjoyed a high reputation in the charging field for its technical advantages such as no demand of operation power from engine and an excellent charging effect in a static operation at mid- and high engine speed. A mechanically driven super-charger, however, is now popular due to the high engine power at quick change of the driving mode - high engine torque even at low engine speed. Since super-charger needs operation power from engine, it is difficult to improve its relatively higher fuel consumption than that of turbo-charger. This negative point is still an obstacle to the wide use of supercharger. Super-charger using screw-type compressor will fulfill the purpose to reduce fuel consumption by minimizing operation power owing to no charge at idling or part load driving condition. This study aims to develop power control concept to achieve the minimization of operation power. A screw type super-charger was modified in design partially and installed with an internal bypass valve and a bypass tube to control charging pressure at part load. The various control concepts show a possibility to reduce operation power of super-charger.

가변 지속시간을 갖는 이벤트 기반 원격제어 (Event Based Tele-Operation with Variable Holding Time)

  • 박준영;박장현
    • 한국정밀공학회지
    • /
    • 제19권12호
    • /
    • pp.70-77
    • /
    • 2002
  • Necessity of the tole-operation has been increased in many fields. Since the Internet is inexpensive and available all over the world, it is a strong candidate for the transmission media of the tole-operation. However, the Internet has random time delays that may cause instability in the system especially if the tole -operation is bilateral. In the past few years many attempts have been made to overcome the random time delay, So far, they are still insufficient in terms of performance. The ‘Variable holding time’ is introduced to improve the performance of the ‘Event based tole-operation’ which controls a system with a non-time action reference. By holding each event for proper time, the system can quickly respond and be stabilized. The proper holding time should be selected based on the characteristics of the task that the system performs. The factors that reflect those characteristics are investigated. The fuzzy logic is employed to obtain the proper holding time for each event while the tole-operation system is in operation. The experimental results presented in this paper verify effectiveness of the proposed method.

A Study on the Routing of Onboard Oriented Control System by Operation Scenario

  • Baek, Jong-Hyen;Kim, Yong-Gyu;Song, Yong-Soo;Oh, Se-Chan;Shin, Dong-Ho
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제2권4호
    • /
    • pp.473-477
    • /
    • 2013
  • The railway developed countries in Europe, Japan such as ERTMS Regional, FFB, COMBAT, it is the stage of development or testing the train control system for the signal system of branch interval of low density. Similar to the signal system used by the mainline and branch sections of low density domestic portions not suitable in terms of maintenance operational efficiency in accordance with the installation and operation in many cases. Therefore these low-density branch railway lines required that oriented train control system of wireless communication to improve the operation efficiency and line side equipment controlled on board the train. In this paper, We was published a route on setting is the operation of the new on-board oriented train control system for controlling a line converter of the train so that it is possible to improve the operational efficiency of the branch of the low density.

안벽크레인 시뮬레이터 원격운전 시스템 개발 (Development of a Remote Operation System for a Quay Crane Simulator)

  • 강성호;이상진;추영열
    • 제어로봇시스템학회논문지
    • /
    • 제21권4호
    • /
    • pp.385-390
    • /
    • 2015
  • Quay cranes are considered core equipment for container terminal operation. However, unmanned operation systems have not as yet been announced due to the technological difficulties of implementation. In this paper, we developed a wireless controller to control a quay crane simulator remotely and conducted its performance test, a first step toward unmanned operation of quay cranes. The communication delay of a developed wireless controller was about 9.4ms on average while that of existing wired controllers was about 5.6ms. The same functions were implemented and tested on a smart phone where the average communication delay was 7.3ms. In addition, to apply the developed system into a real environment, we proposed a network architecture based on IEEE 802.11ac and carried out its performance evaluation. When the distance between two nodes was 50m apart, the throughputs of the TCP (Transmission Control Protocol) and UDP (User Datagram Protocol) were 57Mbps and 189Mbps, respectively. The communication delay of the control data was 9.1ms through the TCP channel. These results reveal the proper working of remote quay crane operation if we adopt the IEEE 802.11ac network.

계통연계형 풍력, 태양광 및 축전지 하이브리드 시스템의 출력제어 및 동특성 해석 (Power Control and Dynamic Performance Analysis of a Grid-Interactive Wind/PV/BESS Hybrid System)

  • 김슬기;전진홍;조창희;안종보
    • 전기학회논문지
    • /
    • 제56권2호
    • /
    • pp.317-324
    • /
    • 2007
  • Most conventional hybrid systems using renewable energy sources have been applied for stand-alone operation, but Utility-interface may be an useful and viable option for hybrid systems. Grid-connected operation may have benefits such as reduced losses in power system distribution, utility support in demand side management, and peak load shaving. This paper addresses power control and dynamic performance of a grid-connected PV/wind/BESS hybrid system. At all times the PV way and the wind turbine are individually controlled to generate the maximum energy from given weather conditions. The battery energy storage system (BESS) charges or discharges the battery depending on energy gap between grid invertger generation and production from the PV and wind system. The BESS should be also controlled without too frequently repeated shifts in operation mode, charging or discharging. The grid inverter regulates the generated power injection into the grid. Different control schemes of the grid inverter are presented for different operation modes, which include normal operation, power dispatching, and power smoothing. Simulation results demonstrate that the effectiveness of the proposed power control schemes for the grid-interactive hybrid system.

OVERVIEW OF KSTAR INTEGRATED CONTROL SYSTEM

  • Park, Mi-Kyung;Kim, Kuk-Hee;Lee, Tae-Gu;Kim, Myung-Kyu;Hong, Jae-Sic;Baek, Sul-Hee;Lee, Sang-Il;Park, Jin-Seop;Chu, Yong;Kim, Young-Ok;Hahn, Sang-Hee;Oh, Yeong-Kook;Bak, Joo-Shik
    • Nuclear Engineering and Technology
    • /
    • 제40권6호
    • /
    • pp.451-458
    • /
    • 2008
  • After more than 10 years construction, KSTAR (Korea Superconducting Tokamak Advanced Research) had finally completed its assembly in June 2007, and then achieved the goal of first-plasma in July 2008 through the four month's commissioning. KSTAR was constructed with fully superconducting magnets with material of $Nb_3Sn$ and NbTi, and their operation temperatures are maintained below 4.5K by the help of Helium Refrigerator System. During the first-plasma operation, plasmas of maximum current of 133kA and maximum pulse width of 865ms were obtained. The KSTAR Integrated Control System (KICS) has successfully fulfilled its missions of surveillance, device operation, machine protection interlock, and data acquisition and management. These and more were all KSTAR commissioning requirements. For reliable and safe operation of KSTAR, 17 local control systems were developed. Those systems must be integrated into the logically single control system, and operate regardless of their platforms and location installed. In order to meet these requirements, KICS was developed as a network-based distributed system and adopted a new framework, named as EPICS (Experimental Physics and Industrial Control System). Also, KICS has some features in KSTAR operation. It performs not only 24 hour continuous plant operation, but the shot-based real-time feedback control by exchanging the initiatives of operation between a central controller and a plasma control system in accordance with the operation sequence. For the diagnosis and analysis of plasma, 11 types of diagnostic system were implemented in KSTAR, and the acquired data from them were archived using MDSpius (Model Driven System), which is widely used in data management of fusion control systems. This paper will cover the design and implementation of the KSTAR integrated control system and the data management and visualization systems. Commissioning results will be introduced in brief.

고정폐색 열차제어시스템 속도제어코드 설계에 관한 연구 (Study on the Speed Control Code Design for Fixed Block TCS)

  • 이강미;신경호;신덕호;이재호
    • 한국철도학회논문집
    • /
    • 제15권1호
    • /
    • pp.37-41
    • /
    • 2012
  • 경부고속철도는 운영환경(차량,구배,곡선,시설물 등)에 따라 궤도회로를 여러 개의폐색으로 분할하여 운행하는 고정폐색방식의 열차제어시스템으로 운행된다. 고정폐색방식 열차제어시스템은 선행열차의 점유폐색을 기준으로 진입/진출폐색속도, 목표거리, 감속도와 같은 운행정보를 차상열차제어장치로 전송하여 연속적으로 열차를 제어하는 방식으로, 경부고속철도 열차제어시스템은 열차가 해당 폐색의 진입/진출속도를 초과할 경우, 비상제동명령을 내려 열차의 안전한 운행을 보장한다. 본 논문에서는 안전한 운행을 위해 폐색에 할당되는 속도제어코드의 생성원리를 분석하여, 최고운행속도와 운행차량특성에 따른 속도제어코드를 도출하고, 도출된 속도제어코드에 따른 운행시격 분석을 통해 열차 운행효율을 분석하였다. 이와 같은 연구는 기존 고속철도의 증속 및 신규 고속철도 열차제어시스템 설계 자료로 활용될 수 있다.

퍼지제어모형을 이용한 다목적 댐의 홍수조절모형 (II) - 과거홍수사상에 대한 적용 - (Multipurpose Dam Operation Models for Flood Control Using Fuzzy Control Technique ( II ) - Simulation of Historical Flood Events -)

  • 심재현;김지태;조원철;김진영
    • 한국방재학회 논문집
    • /
    • 제4권1호
    • /
    • pp.41-50
    • /
    • 2004
  • 본 연구에서는 퍼지제어기법을 이용한 홍수조절 모형의 적용성을 파악하기 위해 한강수계 단일댐에 적용하였다. 개발된 모형들의 홍수조절능력을 비교하기 위해 1984, 1990, 1995년 대홍수 발생시 실제 운영실적과 본 연구에서 개발된 모형들의 가상운영결과를 비교하였다. 본 연구에서 개발한 3개 모형은 모두 실제 적용성을 고려하여 댐의 수위와 유입량이라는 2가지 정보량으로부터 방류량을 결정토록 하였으며, 최대방류량 역시 댐 설계시 기준인 허용최대방류량을 초과하지 않도록 하였다. 각 홍수사상에 대해 적용한 결과 기존의 댐 운영결과에 비해 홍수위를 낮출 수 있으면서도 하류부의 피해 최소화에도 적절한 것으로 나타나 퍼지제어모형의 적용성을 확인할 수 있었다.

Five-level Inverter for Excitation Control of SRM Drive

  • Oh, Seok-Gyu;Park, Sung-Jun;Ahn, Jin-Woo
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • 제11B권3호
    • /
    • pp.64-69
    • /
    • 2001
  • Energy recovery in the regenerative region is very important when SRM is used in traction drive, This is to reduce en-ergy loss during mechanical braking and/or to have a high efficiency drive during braking To control excitation voltage in motor operation and regenerative voltage in the generator operation in the SRM multi-level voltage control is effective The paper sug-gests multi-level inverter which is useful for motoring and regenerative operation in SRM

국내 발전소 보일러용 분산제어시스템 운전 화면 구성 (Composition of operation window in a domestic boiler distributed control system)

  • 신만수;변승현;박두용
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 D
    • /
    • pp.2027-2029
    • /
    • 2001
  • In this paper, we are trying to think over operation window of application to a domestic boiler distributed control system. The detailed contents are a plant system overview, and operation window overview, difficulty in changing control system, vision.

  • PDF