• 제목/요약/키워드: Operation Scheme

검색결과 1,987건 처리시간 0.032초

A Special Protection Scheme Against a Local Low-Voltage Problem and Zone 3 Protection in the KEPCO System

  • Yun, Ki-Seob;Lee, Byong-Jun;Song, Hwa-Chang
    • Journal of Electrical Engineering and Technology
    • /
    • 제2권3호
    • /
    • pp.294-299
    • /
    • 2007
  • This paper presents a special protection scheme, which was established in the KEPCO (Korea Electric Power Corporation) system, against a critically low voltage profile in a part of the system after a double-circuit tower outage. Without establishing the scheme, the outage triggers the operation of a zone 3 relay and trips the component. This sequence of events possibly leads to a blackout of the local system. The scheme consists of an inter-substation communication network using PITR (Protective Integrated Transmitter and Receiver) for acquisition of the substations' data, and under-voltage load shedding devices. This paper describes the procedure for determining the load shedding in the scheme and the experiences of the implementation.

DC-DC 컨버터에서 Duty Feedback 을 이용한 새로운 센서리스 제어 기법 (A New Sensorless Control Scheme Using Simple Duty Feedback Technique in DC-DC Converters)

  • 노형주;이동윤;현동석
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 추계학술대회 논문집
    • /
    • pp.115-118
    • /
    • 2001
  • This paper presents a new sensorless control scheme using simple duty signal feedback technique in DC-DC converters. The proposed sensorless control scheme (DFC) has the characteristics that they show the same as operation performance of current mode control by using duty feedback technique without current sensor as well as present better dynamic response performance than conventional sensorless current mode control (SCM) in case that input source is perturbed by step change or DC input source includes the . harmonics. Also, the proposed control scheme has good noise immunity and simple control circuits since they have one feedback loop, and can be applied to all DC-DC converters. The concept and control principles of the proposed control scheme are explained in detail and the validity of the proposed control scheme is verified through several interesting simulated results.

  • PDF

유도형 탄약의 조정날개 구동용 Sensorless BLDC 전동기의 출력 토크 향상을 위한 여자 기법 (Excitation Scheme to Enhance Output Torque of Sensorless BLDC Motor to Drive the Flight Attitude Control Fins of a Guided Artillery Munition)

  • 이태형;김상훈
    • 산업기술연구
    • /
    • 제35권
    • /
    • pp.9-13
    • /
    • 2015
  • In this paper, a new excitation scheme is developed to increase the output torque of the sensorless BLDC(Brushless DC) motor(BLDCM), which drives fins to control the flight attitude of a guided artillery munition. The proposed scheme is based on a 12-step excitation strategy combining two-phase and three-phase excitations. The proposed 12-step excitation scheme can produce more torque than a typical 6-step scheme for the start-up and synchronous operation in the sensorless BLDCM drive. The simulation and experimental results on the sensorless BLDCM drive system to control the fin were verified the validity of the proposed scheme.

  • PDF

배전시스템센서의 순간전압강하 분석 (Analysis of Voltage Sag on Power Distribution System)

  • 오정환;임성정;윤상윤;김재철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 D
    • /
    • pp.954-957
    • /
    • 1997
  • In this paper, we analyze the voltage sag caused by reclosing on electric power distribution system. When a fault is on the electric system, a reclosing operation brings a voltage sag on the feeders which is supplied with a common substation transformer. By analyzing the fault wave-form measured in the field, it is showed that a voltage sag is in proportion to a fault current. Also, we propose an adaptive reclosing scheme. This scheme changes the number of reclosing as a function of the magnitude of a fault voltage and the fault type. As the proposed scheme is compared with conventional scheme in the side of voltage sag and permanent fault, it is verified that the proposed scheme is more effective than conventional scheme.

  • PDF

재폐로방식이 전력용 변압기에 미치는 영향 평가 (Evaluation of Damage from Reclosing Scheme for Power Transfromer)

  • 오정환;윤상윤;임성정;김재철
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제48권3호
    • /
    • pp.177-183
    • /
    • 1999
  • This paper presents how to evaluate the transformer damage caused by reclosing scheme at the distribution substation. We describe a quantitative relationship between the reclosing scheme and the number of fault current flowing through transformer wsing the probability of a reclosing success/failure. The transformer damage from reclosing scheme is presented using a weight function and a damage function. A weight function is associated with the number of reclosing attempts and the reclosing deadtime to consider cumulative stress caused by reclosing scheme. A damage function is associated with a transformer impact ratio and a transformer functional life. In the case study, the transformer damage is simulated for the probability of a reclosing success. And the evaluation of transformer damage using KEPCO's operation data is performed.

  • PDF

Two-Input Max/Min Circuit for Fuzzy Inference System

  • P. Laipasu;A. Chaikla;A. Jaruwanawat;P. Pannil;Lee, T.;V. Riewruja
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.105.3-105
    • /
    • 2001
  • In this paper, a current mode two-input maximum (Max) and minimum (Min) operations scheme, which is a useful building block for analog fuzzy inference systems, is presented. The Max and Min operations are incorporated in the same scheme with parallel processing. The proposed scheme comprises a MOS class AB/B configuration and current mirrors. Its simple structure can provide a high efficiency. The performance of the scheme exhibits a very sharp transfer characteristic and high accuracy. The proposed scheme achieves a high-speed operation and is suitable for real-time systems. The simulation results verifying the performances of the scheme are agreed with the expected values.

  • PDF

Giga Bit급 저전력 synchronous DRAM 구조에 대한 연구 (A study on the low power architecture of multi-giga bit synchronous DRAM's)

  • 유회준;이정우
    • 전자공학회논문지C
    • /
    • 제34C권11호
    • /
    • pp.1-11
    • /
    • 1997
  • The transient current components of the dRAM are analyzed and the sensing current, data path operation current and DC leakage current are revealed to be the major curretn components. It is expected that the supply voltage of less than 1.5V with low VT MOS witll be used in multi-giga bit dRAM. A low voltage dual VT self-timed CMOS logic in which the subthreshold leakage current path is blocked by a large high-VT MOS is proposed. An active signal at each node of the nature speeds up the signal propagation and enables the synchronous DRAM to adopt a fast pipelining scheme. The sensing current can be reduced by adopting 8 bit prefetch scheme with 1.2V VDD. Although the total cycle time for the sequential 8 bit read is the same as that of the 3.3V conventional DRAM, the sensing current is loered to 0.7mA or less than 2.3% of the current of 3.3V conventional DRAM. 4 stage pipeline scheme is used to rduce the power consumption in the 4 giga bit DRAM data path of which length and RC delay amount to 3 cm and 23.3ns, respectively. A simple wave pipeline scheme is used in the data path where 4 sequential data pulses of 5 ns width are concurrently transferred. With the reduction of the supply voltage from 3.3V to 1.2V, the operation current is lowered from 22mA to 2.5mA while the operation speed is enhanced more than 4 times with 6 ns cycle time.

  • PDF

계통연계형 태양광 인버터 병렬운전 상황에서의 단독운전 검출 (Islanding Detection for Grid-connected PV Inverter under Parallel Operation)

  • 조영민;김동균;송승호;최익;이영권;조상윤;최주엽
    • 전력전자학회논문지
    • /
    • 제21권4호
    • /
    • pp.283-289
    • /
    • 2016
  • Islanding protection of a grid-connected photovoltaic (PV) inverter is a key function for standards compliance. Unintentional islanding results in safety hazards, reliability, and many other issues. Therefore, many anti-islanding schemes have been examined. However, existing anti-islanding schemes have poor power quality and non-detection zone issues. Moreover, most schemes have problems that deteriorate the performance of islanding detection under parallel operation. Therefore, this paper proposes a novel anti-islanding scheme that has negligible power quality degradation and has no non-detection zone and islanding detection under a parallel operation. Both simulation and experimental results validate the proposed scheme.

Face Milling에서 Exit Burr의 최소화를 고려한 최적 가공 계획 알고리즘의 개발 (Development of optimal process planning algorithm considered Exit Burr minimization on Face Milling)

  • 김지환;김영진;고성림;김용현;박대흠
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.1816-1819
    • /
    • 2003
  • As a result of milling operation, we expect to have burr at the outward edge of workpiece. Also, it causes undesirable problems such as deburring cost, low quality of machined surface, and bottleneck in manufacturing process. Though it is impossible to totally remove burr in machining, it is necessary to plan a machining process that minimizes the occurrence of burr. In this paper, a scheme is proposed which identifies the tool path of the milling operation with minimum burr. In the previous research, a Burr Expert System was developed where the feature identification, the cutting condition identification, and the analysis on exit burr formation are the key steps in the program. The Burr Expert System predicts which portion of workpiece would have the exit burr in advance so that we can calculate the burr length of each milling operation. Here, the critical angle determines whether the burr analyzed is an exit burr or not. So the burr minimization scheme becomes to minimize the burr with critical angle. By iterating all the possible tool paths in certain milling operation, we can identify the tool path with minimum burr.

  • PDF

기상예보를 고려한 관개용 저수지의 최적 조작 모형(II) -모형의 구성- (Optimal Reservoir Operation Models for Paddy Rice Irrigation with Weather Forecasts (II) -Model Development-)

  • 김병진;박승우
    • 한국농공학회지
    • /
    • 제36권2호
    • /
    • pp.44-55
    • /
    • 1994
  • This paper describes the development of real-time irrigation reservoir operation models that adequately allocate available water resources for paddy rice irrigation. Water requirement deficiency index(WRDI) was proposed as a guide to evaluate the operational performance of release schemes by comparing accumulated differences between daily release requirements for irrigated areas and actual release amounts. Seven reservoir release rules were developed, which are constant release rate method (CRR), mean storage curve method(MSC), frequency analysis method of reservoir storage rate(FAS), storage requirement curve method(SRC), constant optimal storage rate method (COS), ten-day optimal storage rate method(TOS), and release optimization method(ROM). Long-term forecasting reservoir operation model(LFROM) was formulated to find an optimal release scheme which minimizes WRDIs with long-term weather generation. Rainfall sequences, rainfall amount, and evaporation amount throughout the growing season were to be forecasted and the results used as an input for the model. And short-term forecasting reservoir operation model(SFROM) was developed to find an optimal release scheme which minimizes WRDIs with short-term weather forecasts. The model uses rainfall sequences forecasted by the weather service, and uses rainfall and evaporation amounts generated according to rainfall sequences.

  • PDF