• Title/Summary/Keyword: Operation Regulation

Search Result 704, Processing Time 0.031 seconds

Case Study of the Manless Operation of Urban Transit (도시철도 무인운전에 대한 사례분석 연구)

  • Lee, Young-Hoon;Cho, Bong-Kwan
    • Proceedings of the KSR Conference
    • /
    • 2011.05a
    • /
    • pp.1014-1022
    • /
    • 2011
  • Urban transit operation is to manipulate the vehicle or train of urban transit to be operated on the basis of the installations such as track, power, communication, signaling and so on. It can be performed by manual or automated, or manned or manless operation considering its system built, operation efficiency, safety, etc. Because of the heavy impact directly to the safety of passenger transport, it has been managed strictly by the Regulation for Train Operation of Urban Transit according to Urban Transit Act. However, the present regulation has been basis of the manual operation mainly, it is crossing beyond the limitation of application to the manless operation which is being introduced moment to moment. It is needed increasingly to revise the regulation for the manless operation which is close at hand now. In this paper, we examined and analysed the cases of manless operation of urban transit planed within the country such as Busan 4th Line, Shinbundang Line, Busan-Kimhae Line, etc. based on the present regulation, and proposed the review of considerations to reflec the manless operation to the regulation to be revised.

  • PDF

Decentralized Vehicle-to-Grid Design for Frequency Regulation within Price-based Operation

  • Kim, Seung Wan;Jin, Young Gyu;Song, Yong Hyun;Yoon, Yong Tae
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.3
    • /
    • pp.1335-1341
    • /
    • 2015
  • The utilization of electric vehicles has been suggested to support the frequency regulation of power system. Assuming that an intermediate aggregator exists, this study suggests a decentralized vehicle-to-grid operation scheme in which each vehicle-to-grid aggregator can behave independently of the power system operator. To implement this type of decentralized operation, this study adopts a price-based operation that has been proposed by many researches as an alternative operation scheme for the power system. In this environment, each vehicle-to-grid aggregator can determine its participation in vehicle-to-grid service in consideration of its residual energy of aggregated system and real-time market price. Consequently, the main purpose of this study is to verify whether or not the vehicle-to-grid power can effectively support the current frequency regulation function within the price-based operation scheme. Specifically, a frequency regulation method is proposed based on the real-time price signal, and a feedback controller for battery management is designed for decentralized vehicle-to-grid operation.

Development and Application of Operation Methods of Battery Energy Storage System for Frequency Regulation (주파수조정용 배터리 에너지저장장치 운전방법의 개발과 적용)

  • Lim, Geon-Pyo;Park, Doo-Yong
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.64 no.2
    • /
    • pp.57-61
    • /
    • 2015
  • Current research and development efforts and other projects for energy storage systems (ESS) have recently been gaining attention. This is due to the many applications where ESS, particularly batteries, can be used. Among these are peak shaving, frequency regulation, and stabilization of renewable energy output. KEPCO has completed the construction and demonstration of a 4-MW battery energy storage system (BESS) located in Jeju City to verify its practicability in the power grid. KEPCO Research Institute has also been developing technology for the commercialization of BESS, and has been conducting a trial run of a 52-MW ESS (28MW + 24MW of Seo-Anseong and Shin-Yongin substations) constructed in 2014 for frequency regulation. This paper discusses the development of operation methods, as well as an operation user interface, for the safe operation and monitoring of BESS used for frequency regulation in a power system. Included are operation and simulation methods for various normal and transient frequency situations that can be experienced by a power system. Also discussed are the results obtained after applying these methods to the 4-MW BESS and the 52-MW ESS, both used for frequency regulation. The technology in this paper will be applied to 500MW ESS for frequency regulation of KEPCO by 2017. It is expected that this technology helps a safe and reliable operation and control of ESS for frequency regulation through its continuous upgrade.

DC Bus Voltage Regulation With Six-Step Operation in Maritime DC Power System (식스 스텝 운전을 이용한 선박용 DC 전력 시스템의 직류단 전압 제어)

  • Yun, Jonghun;Son, Young-Kwang;Sul, Seung-Ki
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.26 no.4
    • /
    • pp.263-270
    • /
    • 2021
  • Active AC/DC converters with PWM operation are utilized to regulate rectified DC bus voltage of a permanent magnet synchronous generator in the maritime DC power system. A DC bus voltage regulation strategy that exploits the six-step operation is proposed in this study. Compared with that of the PWM operation, switching loss of the converter can be significantly reduced under the six-step operation. Moreover, conduction loss can also be reduced due to the high modulation index and reduced flux-weakening current of the six-step operation. A controller is used for the proposed DC bus voltage regulation strategy to verify its validity with the simulation and experimental setup. The simulation and the experimental test results showed that the converter loss reduces to a maximum of 70% and 19%, respectively.

Development of Generic Train Operation Model Based on Korean Urban Transit Regulations

  • Lee, Young-Hoon
    • International Journal of Railway
    • /
    • v.4 no.4
    • /
    • pp.81-85
    • /
    • 2011
  • This paper discusses the development of a generic train operation model from a set of Korean Urban Transit Regulations such as Regulation for Train Operation of Urban Transit, Regulation for Safety Requirements of Urban Transit and so on. It is to communicate with various stakeholders on urban transit system, and to elicit copious requirements in performance of the urban transit train operation based on the model.

  • PDF

A Study on the Driving Regulation of the Urban Railway Electric Multiple Units with Block Systems (폐색방식에 따른 도시철도차량 운전기준에 관한 연구)

  • Cheon, Y.S.;Ahn, S.H.;Chung, K.W.;Kim, C.S.;Chung, J.D.;Chung, N.K.
    • Proceedings of the KSR Conference
    • /
    • 2009.05a
    • /
    • pp.707-712
    • /
    • 2009
  • Block system has been used to protect trains from occupying the same section of track at the same time so that only one train is permitted in each block at a time. Domestic driving regulations on the block system is divided into two classifications, such as regular block and substitute block. If it is impossible to use this regulation, the block applied method can be applied. However, domestic urban railway administrator has established his own operation rule within the regulation. Therefore, in order to assure continuous safety of train in operation, it is necessary to strengthen the regulation as can cope with the various block systems. In this study, domestic urban railway administration's own rules are examined and the appropriate driving regulation on the block system is proposed.

  • PDF

Development of Operation and Control Technology of Energy Storage System for Frequency Regulation and Operation by Grid Connected Automatic Control (주파수조정용 에너지저장장치 운전제어 기술의 개발과 계통연계 자동제어 운전)

  • Lim, Geon-Pyo;Choi, Yo-Han;Im, Ji-Hoon
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.65 no.4
    • /
    • pp.235-241
    • /
    • 2016
  • Grid-connected, large-capacity energy storage systems (ESS) can be used for peak load supply, frequency regulation, and renewable energy output smoothing. In order to confirm the capability of battery ESS to provide such services, 4MW/ 8MWh battery ESS demonstration facility was built in the Jocheon substation on Jeju Island. The frequency regulation technology developed for the Jocheon demonstration facility then became the basis for the 28MW and 24MW frequency regulation ESS facilities installed in 2014 at the Seo-Anseong and Shin-Yongin substations, respectively. The operation control systems at these two facilities were continuously improved, and their successful commercialization led to the construction of additional ESS facilities all over Korea in 2015. In seven (7) locations nationwide (e.g., Shin-Gimje and Shin-Gyeryeong), a total of 184 MW of ESS had been commercialized in 2016. The trial run for the new ESS facilities had been completed between April and May in 2016. In this paper, results of the trial run from each of the ESS facilities are presented. The results obtained from the Seo-Anseong and Shin-Yongin substations during a transient event by a nuclear power plant trip are also presented in this paper. The results show that the frequency regulation battery ESS facilities were able to quickly respond to the transient event and trial run of ESS is necessary before it is commercialized.

A Study on the Reclosing Operation of Distribution System considering the ESS (ESS를 고려한 배전계통 재폐로 동작에 관한 연구)

  • Seo, Hun-Chul;Kim, Chul-Hwan;Rhee, Sang-Bong
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.583-584
    • /
    • 2015
  • Energy Storage System(ESS) can be used as several purposes such as uninterruptible power supply (UPS), frequency regulation, maximum load cut, and etc. This paper analyzes and simulates the reclosing operation in distribution system with ESS for frequency regulation and maximum load cut. To solve the effect from ESS, two sequences in reclosing process are added to conventional reclosing. The modelings and simulations of reclosing operation using EMTP/ATPDraw are performed.

  • PDF

A Study on Operation Method of Power Distribution System Integrated with Dispersed Generation System (분산형전원이 도입된 복합배전계통의 운용방안에 대한 고찰)

  • Kim, Jae-Eon;Jo, Seong-Hyeon
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.6
    • /
    • pp.692-698
    • /
    • 1999
  • This paper analyzes the effect of DGS(Dispersed Generation System) on the voltage regulation of the traditional distribution system of which the voltage is controlled by the bank LDC(Line Drop Compensator). Through the simulation results for 22.9kV class distribution system with DGSs, some general relationships among the operating power factor and introduction limit of DGS, and the sending-end reference voltage determined by internal setting coefficients of the LDC are derived. Those relationships are that the introduction limit of DGS increases as the power factor of DGS goes from lagging to leading and also as the allowance of the sending-end reference voltage increases. From the relationships, a operation method of the power distribution system integrated with DGSs is proposed from the view point of the operating power factor of DGS and new voltage regulation method.

  • PDF

A Study on Improvement of the Interface Control of NPP Construction and Operation Activities

  • Chung, Ku-Young;Lee, Woo-Ho;Lee, Jae-Hun
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 2005.05a
    • /
    • pp.1221-1222
    • /
    • 2005
  • Interface control activities during the nuclear power plant (NPP) construction and operation have been reviewed for enhancing the safety of NPP. The primary focus of the study is given on analysis of lessons learned from the recent significant events of Korean Standard Nuclear Power plant (KSNP), such as a series of break-off of thermal sleeves at YGN 5 & 6 and radioactivity leak at YGN 5, in respect of interface control. Based on the results of the analysis, this study recommends measures for the improvement of interface control among utility and technical supporting organizations (TSO), and suggests new regulatory systems, such as reporting of safety significant non-conformances, to effectively verify the adequacy of interface control activities during construction and operation of NPPs.

  • PDF