• Title/Summary/Keyword: Operation Ratio

Search Result 2,791, Processing Time 0.031 seconds

Guidline for the Maximum Surgical Blood Order Schedule (MSBOS) for Surgical Operations (수술용 최대혈액신청량(MSBOS)의 설정)

  • Shin, Kyung A;Choi, Jong Tai;Kim, Hyun Soo
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.36 no.2
    • /
    • pp.153-157
    • /
    • 2004
  • The aim of our study is to determine maximum surgical blood order schedule (MSBOS) in each surgical operation through analyzing usage of blood products at Bundang Jesaeng General Hospital. We investigated the amount of transfused red cells for each operation and calculated crossmatching-to-transfusion ratio (C/T ratio) and MSBOS. This was accomplished by referring to the Laboratory Information System program during 1 year from January through December 2003. Coronary artery bypass surgery and decompressive craniectomy showed the highest MSBOS in our hospital. The average C/T ratio was 3.2 and excessive reservations for blood products have been made for many operations. From this study, guidelines for the optimal blood ordering for each surgery were suggested.

  • PDF

Analysis of Maximum Generating Power Drop of PV Module Under the Continuous Artificial Light Irradiation Test Condition (연속 광조사 조건에서의 태양전지모듈의 연간 최대출력 저하율 변화 예측 분석)

  • Kim, Kyungsoo;Yun, Jaeho
    • Current Photovoltaic Research
    • /
    • v.6 no.3
    • /
    • pp.69-73
    • /
    • 2018
  • PV system is consisted with PV module, inverter and BOS(balance of system). To have robustic operation more than 20 years, the expected and guaranteed durability and reliability of products should be met. Almost components of PV system are qualified through IEC standards at test laboratory. But the qualification certificate of product does not ensure long-term nondefective operation. PV module's expected life time is nowadays more than 20 years and annual maximum power degradation ratio would be less than -1%. But the power degradation ratio is basically based on real data more than several years' record. Developing test method for ensuring annual maximum power degradation ratio is very need because there are many new products every month with new materials. In this paper, we have suggested new test method under continuous artificial light irradiation test condition for analyze expected maximum power drop ratio.

ANALYSIS OF HCCI COMBUSTION CHARACTERISTICS BASED ON EXPERIMENTATION AND SIMULATIONS-INFLUENCE OF FUEL OCTANE NUMBER AND INTERNAL EGR ON COMBUSTION

  • Iijima, A.;Yoshida, K.;Shoji, H.;Lee, J.T.
    • International Journal of Automotive Technology
    • /
    • v.8 no.2
    • /
    • pp.137-147
    • /
    • 2007
  • Homogenous Charge Compression Ignition (HCCI) combustion systems can be broadly divided for the process applied to 4-stroke and 2-stroke engines. The former process is often referred to as simply HCCI combustion and the latter process as Active Thermo-Atmosphere Combustion (ATAC). The region of stable engine operation tends to differ greatly between the two processes. In this study, it was shown that the HCCI combustion process of a 4-stroke engine, characterized by the occurrence of autoignition under a high compression ratio, a lean mixture and wide open throttle operation, could be simulated by operating a 2-stroke engine at a higher compression ratio. On that basis, a comparison was made of the combustion characteristics of high-compression-ratio HCCI combustion and ATAC, characterized as autoignited combustion in the presence of a large quantity of residual gas at a low compression ratio and part throttle. The results showed that one major difference between these two combustion processes was their different degrees of susceptibility to the occurrence of cool flame reactions. Compared with high-compression-ratio HCCI combustion, the ignition timing of ATAC tended not to change in relation to different fuel octane numbers. Furthermore, when internal EGR was applied to high-compression-ratio HCCI combustion, it resulted in combustion characteristics resembling ATAC. Specifically, as the internal EGR rate was increased, the ignition timing showed less change in relation to changes in the octane number and the region of stable engine operation also approached that of ATAC.

Comparison of Cognitive Development, and Logical Thinking Formation Levels between Elementary Gifted Students and General Students (초등 영재와 일반 학생의 인지발달 및 논리적 사고력 형성 수준 비교)

  • Lee, Chong-Sup;Yoo, Mi-Hyun
    • Journal of Gifted/Talented Education
    • /
    • v.23 no.3
    • /
    • pp.335-354
    • /
    • 2013
  • The purpose of this study was to investigate cognitive development and logical thinking formation levels of elementary gifted students and to compare with those of elementary regular students. For this purpose, 79 gifted elementary school students and 114 regular elementary school students in Kyunggi Province were participated, and GALT(Group Assessment of Logical Test) was administered to them. The results obtained in this study were as follows. First, the logical thinking scores of elementary gifted students were significantly higher than general students'(p<.05). Comparing the distribution of cognitive development level, elementary gifted students showed higher ratio in formal operation and lower ratio in concrete operation compared to the general students. It was interpreted that the cognitive development of gifted students preceded general students'. Second, analyzing according to the grade of elementary gifted students, logical thinking scores were significantly different between 5th graders and 6th graders(p<.05). Compared to 5th graders, logical thinking and formal operation ratio of 6th gifted graders showed significantly higher. The scores of four logical thinking areas except for conservational logic and correlational logic of 6th gifted graders showed significantly higher than 5th gifted graders'. Both 5th and 6th graders showed the highest formation ratio in combinational logic, and the lowest ratio in correlational logic. Third, logical thinking scores of gifted students according to gender did not show a significant difference(p>.05). The gifted boys reached formal operation more than gifted girls, but stayed more in the concrete operation. There was gender difference in correlational logic. The gifted girls showed significantly higher than gifted boys in correlational logic(p<.05).

The Effect of Learning Cycle Model in Solution Concept on the Cognitive Development for Primary Student (용액 개념의 순환학습이 초등학생의 인지수준발달에 미치는 영향)

  • 최영주;김세경;고영신
    • Journal of Korean Elementary Science Education
    • /
    • v.23 no.4
    • /
    • pp.273-278
    • /
    • 2004
  • According to Piaget, children aged 11 are in the middle of concrete operation period and formal operation period. So, it is necessary to adopt the Learning Cycle Model (LCM) which helps students improve their cognitive development. After determining the test for the Science Concept of Matter (SCOM), the experimental group showed higher average than the comparative group in the post-test. In the sound understanding, the experimental group showed higher ratio than the comparative group. And in the ratio of imperfect, wrong understanding and no response, the experimental group was lower than the comparative group. On the questions that were needed the complicated inquiry, many students of both groups still couldn't find the fundamental cause. In forming the scientific conceptualization, there was a meaningful difference (p < .001) after post-test Analysis of Covariance (ANCOVA) with pre-test result. After determining the test for the Test Inquiry Science Process (TISP), the experimental group showed higher average than the comparative group in the post-test. In the category of basic inquiry process which is needed in concrete operation, there was a meaningful difference (p < .05). In the category of unified inquiry process which is needed in formal operation, they showed no meaningful difference (p > .05). Therefore, applying the LCM to the chapter of 'Solution and Dissolving' is more effective on improving the scientific conceptualization and on helping the concrete operation abilities than the teacher centered learning.

  • PDF

Prediction of practically chargeable cold energy in an ice storage system (빙축열시스템의 실질적인 최대 축열 가능량 예측)

  • Lee, D.-Y.;Kang, B.H.;Kim, M.S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.1
    • /
    • pp.133-146
    • /
    • 1999
  • The charge operation of an ice storage system has been analyzed in this paper. The thermal characteristics of major components of the ice storage system. i.e., the refrigerator and the ice storage tank are evaluated from performance tests on an existing ice storage system. Based on the measured data for thermal characteristics, a simulation is carried out for the charge operation and the effect of the refrigerator size on the system performance is investigated. The results indicate that the larger the refrigerator size for a given storage capacity, the lower the inlet temperature of the ice storage tank so that the lower the efficiency of charge operation. It is also found that there exists an optimal size of the refrigerator with which the ice storage at the end of the charge operation is maximized, but the complete charge is not possible even with the optimally sized refrigerator. This leads to the result that the design capacity of the storage tank should be larger than the required amount of cold energy for the daytime cooling considering the practically chargeable amount of cold energy during the nighttime. Where the cooling load sharing of the storage is 40%, the nominal capacity of an ice storage tank needs to be larger than the required storage amount by 30%.

  • PDF

Temperature characteristics of condenser and evaporator of Air-conditioner applying variable capacity compressor under cooling condition (가변용량 압축기를 적용한 에어컨의 냉방운전 시 응축 및 증발온도 특성)

  • Kwon, Young-Chul;Chun, Chong-Keun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.8 no.6
    • /
    • pp.1325-1331
    • /
    • 2007
  • In order to investigate the cooling capacity of an air-conditioner applying a variable capacity compressor and the temperature characteristics on a condenser and an evaporator, the experiment on the operation characteristics of the air-conditioner was performed along a compressor operation ratio and an indoor/outdoor temperatures, under a cooling operation mode. The system characteristics were measured by the psychrometric calorimeter. The cooling capacity increased with decreasing the outdoor temperature and increasing the indoor temperature. Also, it increased with increasing the compressor operation ratio. The temperature of the condenser was more sensitive for the variation of the outdoor temperature and the temperature of the evaporator was more sensitive for the variation of the indoor temperature. The operation characteristics of the cycle used in this present were also analyzed by a pressure-enthalpy chart.

  • PDF

Water Quality Prediction of the Mankyung Water Shed according to Construction of New Sewage Treatment Facilities (하수처리시설 신설에 따른 QUAL2E모델에 의한 만경수계 수질예측)

  • Chung, Paulgene;Hyun, Mihee;Jung, Jinpil
    • Journal of Korean Society on Water Environment
    • /
    • v.26 no.2
    • /
    • pp.200-207
    • /
    • 2010
  • The sewage treatment plants to be built to improve the water quality of the Mankyung River will total 11, of which combined capacity will reach $39,850m^3/day$, and saying in detail, 5 at Gunsan city, 2 at Iksan city, 1 at Kimje city and 3 at Wanju gun, The scenario for water quality improvement was developed, considering the conditions of plant operation ratio and the accomplishment of the water quality target (BOD 4.4 mg/L, T-P 0.356 mg/L) at the end of the watershed of Mankyung B was predicted, making use of QUAL2E model. As a result of prediction using QUAL2E model based on scenarios with 70% and 100% of operation ratio, respectively, at 11 plants in 2010, the water quality at the watershed of Mankyung B was estimated at 4.322 mg/L which was lower than the target of BOD 4.4 mg/L, indicating the target water quality was achieved, when it comes to 70% of operation ratio, But in case of T-P, it was estimated at 0.565 mg/L, which was higher than the target. When it comes to 100% of operation ratio, T-P also was 0.563 mg/L which exceeded the target, 0.356 mg/L. As indicated above, the effect of water quality improvement appeared very insignificant, which was attributable to the limit of small scale sewage treatment plant in total reduction capacity. Hence, the measures for additional reduction in a bid to achieve the target water quality of T-P at the designated location need to be taken, and the measures to build the Sewage treatment facilities at the place where the pollution is significantly caused by T-P appeared to be required as well.

Analysis of Operation Parameters of Pilot-Scale Packed-Absorption System for Airborne Methyl Ethyl Ketone Control (공기 중 메틸에틸케톤 제어를 위한 Pilot-Scale 흡수 시스템의 운영인자 분석)

  • Jo, Wan-Kuen;Kim, Wang-Tae
    • Journal of Environmental Science International
    • /
    • v.20 no.4
    • /
    • pp.501-509
    • /
    • 2011
  • Unlike many laboratory-scale studies on absorption of organic compounds (VOCs), limited pilot-scale studies have been reported. Accordingly, the present study was carried out to examine operation parameters for the effective control of a hydrophilic VOC (methyl ethyl ketone, MEK) by applying a circular pilot-scale packed-absorption system (inside diameter 37 cm ${\times}$ height 167 cm). The absorption efficiencies of MEK were investigated for three major operation parameters: input concentration, water flow rate, and ratio of gas flow-rate to washing water amount (water-to-gas ratio). The experimental set-up comprised of the flow control system, generation system, recirculation system, packed-absorption system, and outlet system. For three MEK input concentrations (300, 350, and 750 ppm), absorption efficiencies approached near 95% and then, decreased gradually as the operation time increased, thereby suggesting a non-steady state condition. Under these conditions, higher absorption efficiencies were shown for lower input concentration conditions, which were consistent with those of laboratory-scale studies. However, a steady state condition occurred for two input concentration conditions (100 and 200 ppm), and the difference in absorption efficiencies between these two conditions were insignificant. As supported by an established gas-liquid absorption theory, a higher water flow rate exhibited a greater absorption efficiency. Moreover, as same with the laboratory-scale studies, the absorption efficiencies increased as water-to-gas ratios increased. Meanwhile, regardless of water flow rates or water-to-gas ratios, as the operation time of the absorption became longer, the pH of water increased, but the elevation extent was not substantial (maximum pH difference, 1.1).

A Four-Channel Laser Array with Four 10 Gbps Monolithic EAMs Each Integrated with a DBR Laser

  • Sim, Jae-Sik;Kim, Sung-Bock;Kwon, Yong-Hwan;Baek, Yong-Soon;Ryu, Sang-Wan
    • ETRI Journal
    • /
    • v.28 no.4
    • /
    • pp.533-536
    • /
    • 2006
  • A distributed Bragg reflector (DBR) laser and a high speed electroabsorption modulator (EAM) are integrated on the basis of the selective area growth technique. The typical threshold current is 4 to 6 mA, and the side mode suppression ratio is over 40 dB with single mode operation at 1550 nm. The DBR laser exhibits 2.5 to 3.3 mW fiber output power at a laser gain current of 100 mA, and a modulator bias voltage of 0 V. The 3 dB bandwidth is 13 GHz. A 10 Gbps non-return to zero operation with 12 dB extinction ratio is obtained. A four-channel laser array with 100 GHz wavelength spacing was fabricated and its operation at the designed wavelength was confirmed.

  • PDF