• Title/Summary/Keyword: Operation Rate

Search Result 5,363, Processing Time 0.034 seconds

The Analytic Analysis of Suppressing Jet Flow at Guide Tube of Circular Irradiation Hole in HANARO (하나로 원형 조사공의 안내관 제트유동 억제에 대한 해석)

  • Park Y. C.;Wu S. I.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2004.03a
    • /
    • pp.214-219
    • /
    • 2004
  • The HANARO, a multi-purpose research reactor of 30 MWth, open-tank-in-pool type, has been under normal operation since its initial criticality in February, 1995. The HANARO is composed of inlet plenum, grid plate, core channel with flow tubes and chimney. The reactor core channel is located at about twelve m (12 m) depth of the reactor pool and cold by the upward flow that the coolant enters the lower inlet of the plenum, rises up through the grid plate and the core channel and exit through the outlet of chimney. A guide tube is extended from the reactor core to the top of the reactor chimney for easily un/loading a target under the reactor normal operation. But active coolant through the core can be Quickly raised up to the top of the chimney through the guide tube by jet flow. This paper is described an analytical analysis to study the flow behavior through the guide tube under reactor normal operation and unloading the target. As results, it was conformed through the analysis results that the flow rate, about fourteen kilogram per second (14 kg/s) suppressed the guide tube jet and met the design cooling flow rate in a circular flow tube, and that the fission moly target cooling flow rate met the minimum flow rate to cool the target.

  • PDF

The relationship of pulmonary arterial shunts and the operative results in tetralogy of Fallot (활로 4징증에서 폐동맥의 상태와 수술성적과의 관계)

  • An, Jae-Ho;Seo, Gyeong-Pil
    • Journal of Chest Surgery
    • /
    • v.17 no.4
    • /
    • pp.644-656
    • /
    • 1984
  • In Tetralogy of Fallot, the most common congenital cyanotic heart disease, the mortality is decreasing continuously with adequate type and timing of operation. At S.N.U.H., 195 patients were operated from January 1982 to December 1983 and 176 patients among them were analysed in the view of pre-operative pulmonary arterial condition measured by cardiac cineangiogram. The most common associated anomaly was PFO and ASD and they did not affect the postoperative course and mortality. The overall mortality rate was 8.5% in 1982 and 6.8% in 1983 but under 2 years of age, the mortality rate was relatively high as 25% in 1982 and 16.7% in 1983, and when transannular patch widening of Right Ventricular Outflow Tract was used, the mortality rate was 12.5% in 1982 and 27.3% in 1983. Preoperative angiographic measurements of the pulmonary arterial status for prediction of the ratio between the Left Ventricular and Right Ventricular peak systolic pressure were calculated retrospectively according to the Blackstones formula, and the predicted value of PRV/LV greater than 0.6 carried apparently high complication and mortality rate as 16.6% M.R. in 1982 and 11.1 % in 1983. Among postoperative complications, c-RBBB occurred most frequently about 50% but did not influenced to mortality, Low Cardiac Output Syndrome was developed in about 40%. If we select the patient who should have the staged operation including shunt operation and choose the type of RVOT relief, we expect the improvement of postoperative clinical results.

  • PDF

Evaluation of Operation Characteristics with Aeration Time in Intermittent Aeration Membrane Bioreactor (간헐포기 MBR공정에서 포기시간에 따른 운전특성 평가)

  • Lim, Bong-Su;Choi, Bong-Cheol
    • Journal of Korean Society on Water Environment
    • /
    • v.21 no.4
    • /
    • pp.353-359
    • /
    • 2005
  • This study was conducted to evaluate the operation characteristics with aeration time in intermittent aeration membrane bioreactor. The BOD removal efficiency rate of this process was over than 97% regardless of aeration on/off time. To get over than 82% of nitrogen removal efficiency rate, aeration off time needs more than 70 minutes in reactor. Specific denitrfication rate was 2.68 mg $NO_3-N/gMv/hr$ in 40/80 min aeration on/off time, was 2.6 times more than 60/60 min, and 1.4 times more than 50/70 min in 6,300 mg/L of MLSS concentration. Specific nitrification rate was 1.96 mg $NH_4-N/gMv/hr$ in 50/70 min, was 1.4 times more than 40/80 min, but it was effectded little upon nitrification. Microbial activity was effected little according to aeration on/off time, oxygen demend was reduced according to aeration off time increased and microbial concentration increased. The longer aeration off time become, the higher Extraceller Pollymeric Substance (EPS), 50/70 min and 40/80 min in aeration on/off time was increased 1.6 times and 2.7 times, respectively more than 60/60 min because of increase of operation pressure.

Application of peak load for industrial water treatment plant design (공업용수 정수장 설계시 첨두부하 적용방안)

  • Kim, Jinkeun;Lee, Heenam;Kim, Dooil;Koo, Jayong;Hyun, Inhwan
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.30 no.3
    • /
    • pp.225-231
    • /
    • 2016
  • Peak load rate(i.e., maximum daily flow/average daily flow) has not been considered for industrial water demand planning in Korea to date, while area unit method based on average daily flow has been applied to decide capacity of industrial water treatment plants(WTPs). Designers of industrial WTPs has assumed that peak load would not exist if operation rate of factories in industrial sites were close to 100%. However, peak load rates were calculated as 1.10~2.53 based on daily water flow from 2009 to 2014 for 9 industrial WTPs which have been operated more than 9 years(9-38 years). Furthermore, average operation rates of 9 industrial WTPs was less than 70% which means current area unit method has tendency to overestimate water demand. Therefore, it is not reasonable to consider peak load for the calculation of water demand under current area unit method application to prevent overestimation. However, for the precise future industrial water demand calculation more precise data gathering for average daily flow and consideration of peak load rate are recommended.

An Empirical Study on the Operation of Cogeneration Generators for Heat Trading in Industrial Complexes

  • Kim, Jaehyun;Kim, Taehyoung;Park, Youngsu;Ham, Kyung Sun
    • Journal of the Korea Society of Computer and Information
    • /
    • v.24 no.3
    • /
    • pp.29-39
    • /
    • 2019
  • In this study, we introduce a model that satisfies energy efficiency and economical efficiency by introducing and demonstrating cogeneration generators in industrial complexes using various actual data collected at the site. The proposed model is composed of three scenarios, ie, full - time operation, scenario operated according to demand, and a fusion type. In this study, the power generation profit and surplus thermal energy are measured according to the operation of the generator, and the thermal energy is traded according to the demand of the customer to calculate the profit and loss including the heat and evaluate the economic efficiency. As a result of the study, it is relatively profitable to reduce the generation of the generator under the condition that the electricity rate is low and the gas rate is high, while the basic charge is not increased. On the contrary, if the electricity rate is high and the gas rate is low, The more you start up, the more profit you can see. These results show that even a cogeneration power plant with a low economic efficiency due to a low "spark spread" has sufficient economic value if it can sell more than a certain amount of heat energy from a nearby customer and adjust the applied power through peak management.

Complications after Senning Operation for TGA with and Wothout VSD (대혈관전위증에서 Senning수술후 합병증에 관한 임상적 고찰)

  • 안재호
    • Journal of Chest Surgery
    • /
    • v.26 no.8
    • /
    • pp.595-603
    • /
    • 1993
  • We analysed 60 consecutive patients who got Senning operation for transposition of the great arteries [TGA] with or without ventricular septal defects [VSD]. There were 41 simple TGA [group I] and 19 TGA with VSD [Group II], the operative mortality was 20 % [in group I 4.9 %, group II 52.6 %]. Among the survivors [n=48], the mean follow-up period was 7 years [range, 1 year to 13.5 years] and the actuarial survival rate at 13 years were 95 % in group I and 42 % in group II. Preoperative high left ventricular pressure and high pulmonary arterial pressure affected the surviving [p<0.01]. There occurred various type of arrhythmia like junctional rhythm, first degree atrioventricular [AV] block, sick sinus syndrome and complete AV block, and we inserted 2 permanent pacemakers for these patients. The incidence of arrhythmia were 28.2 % [11/39] in group I and 55.6 % [5/9] in group II, and the actuarial freedom from arrhythmia at 13 years after operation was 66 % [71 % in group I, 44 % in group II]. Increased aortic cross clamping time had affected the development of arrhythmia [p<0.05] which meant the complexity of the operation. The total incidence of left ventricular outflow tract obstruction [LVOTO] was 31.3 % [15/48], but only 3 patients [6.25 %] showed the significant gradient requiring reoperation. The pulmonary venous pathway obstruction [PVO] were found in 3 patients, all in group I, and among them only one required the reoperation. The estimated freedom from PVO was 89 % at 13 years [87 % in group I, 100 % in group II], but we couldn`t find any significant systemic venous obstruction in our series. There occurred 27.1 % [13/48] mild degree tricuspid valve regurgitation without necessary surgical correction. We experienced 14.6 % [7/48] reoperation rate: 3 residual VSD, 3 LVOTO, 1 PVO, 3 atrial baffle leakage. For this high incidence of complication rate after Senning operation and high mortality in TGA with VSD, We do not use this kind of surgical modality any more and do the Jatene operation for all the TGA patients since several years ago.

  • PDF

Study on the Public Food Waste Recycling Facility Operation (II) - Focusing on Improvement Plan - (음식물류폐기물 공공 자원화시설 운영에 관한 연구 (II) - 개선방안을 중심으로 -)

  • Hong, Yong-Pyo;Kim, Ung-Yong;Shin, Hyun-Gon
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.24 no.1
    • /
    • pp.51-57
    • /
    • 2016
  • This study is conducted to find out the problems of the public food waste recycling facility operation and its improvement. In order to save the national budget by analyzing plans to expand including operation rate for the food waste recycling facility, the alternative ways are suggested. The result can be as follows: Policy switch is required not only to save budget and stable disposal of food waste but also to promote resource recycling rather than expanding public facilities. In order to change the policy for stable and eco-friendly disposal of food waste, it is necessary to adopt semipublic system that prevent the decline of the rate of operation of private resource recycling facility. Furthermore, it is required to prepare both qualified technologies of public resource recycling and the ways of profitability secure.

Study on The Qptimization of Operating Conditions of batch-type Grain Dryer (평면식 건조기의 적정작업조건 설정에 관한 연구)

  • 박경규;정창주
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.16 no.4
    • /
    • pp.3600-3610
    • /
    • 1974
  • Experimental work of batch-type dryer was conducted to develop its optimurm operating conditions by analyzing the major factors which affect the drying performance. A laboratory batch-type dryer was constructed and tested for various levels of heated-air rates, and depths of grain deposit. Tong-il rice variety having the initial moisture content of approximaely 23 per cent in wet basis was used for the experiment. The criteria selected for establishing the optimum operating condition were the drying performance rate, the thermal efficiency, and the operational cost of the dryer. The results of the study are summarized as follows: 1. The performance rate of dryer for a specific operating condition was defined as total amount of material dried per hour when the moisture content of grains in the upperlayer reaches to 16 per cent in wet basis. The optimum operating conditions as viewed in the rate of drying performance could be justified by functional realtionship between the depth of grain deposit and air flow rate. In other words, there was a definite depth of grain deposit for a given air-rate which make the dryer performance maximum. The optimum grain depth for the batch-type dryer with 3.3㎡ loading area and with the attached axial fan was about 35cm. 2. The thermal efficiency for the dryer was evaluated by the ratio of the latent heat required to evaporate the grain moisture to the heat input required to raise the ambient air-temperature to 40 degree centigrade. The optimum operating condition as viewed in term of thermal efficiency analyzed was that grater depth and lower air flow-rate may be desirable. This condition is contracted with the optimum condition as viewed by the dryer performance rate. 3. The annual operating cost of batch-type dryer was analyzed for different annual hour of use and for different operation condition. The optimum condition as viewed in terms of operating cost was almost identical to one as viewed in terms of dryer performance rate. Therefore, the most economical use of batch-type dryer for the same annual operating hours can be obtained when the dryer operated in the condition of maximum dryer performance rate. Increasing the annual operating hour may be desirable to cut down the dryer operation cost, since the annual hour of dryer use is much sensitive to the operating cost than any peractical conditions of dryer operation. 4. The most desirable operational condition as justified by combining all the criteria, dryer performance rate, thermal efficiency and annual operating cost, could be concluded to operate the dryer in the condition of maximum performance rate. The condition in general is identical to the lowest operation cost for a given annual operating hour.

  • PDF

Implementation and data operations of the robot workcell using the fieldbus (필드버스를 이용한 로봇웍셀의 구현과 자료운용)

  • 박세웅;김동준;김대원;이호길
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.1249-1252
    • /
    • 1996
  • With the expansion of research and development for the CIM and the IMS, the importance of introducing the communication network is being increased. This paper presents an implementation of robot workcell by using Fieldbus and investigates data operation of the robot workcell. Through experiments, the operations of periodic and real-time data, and non-periodic real-time data are studied. Also, the relationship between the network transmission rate and the monitoring results from the sensor is analyzed.

  • PDF