A Study on Coagulant Feeding Control of the Water Treatment Plant Using Intelligent Algorithms (지능알고리즘에 의한 정수장 약품주입제어에 관한 연구)

  • 김용열;강이석
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.9 no.1
    • /
    • pp.57-62
    • /
    • 2003
  • It is difficult to determine the feeding rate of coagulant in the water treatment plant, due to nonlinearity, multivariables and slow response characteristics etc. To deal with this difficulty, the genetic-fuzzy system genetic-equation system and the neural network system were used in determining the feeding rate of the coagulant. Fuzzy system and neural network system are excellently robust in multivariables and nonlinear problems. but fuzzy system is difficult to construct the fuzzy parameter such as the rule table and the membership function. Therefore we made the genetic-fuzzy system by the fusion of genetic algorithms and fuzzy system, and also made the feeding rate equation by genetic algorithms. To train fuzzy system, equation parameter and neural network system, the actual operation data of the water treatment plant was used. We determined optimized feeding rates of coagulant by the fuzzy system, the equation and the neural network and also compared them with the feeding rates of the actual operation data.

OVERALL LINK ANALYSIS ON HRIT AND LRIT IN COMS

  • Park Durk-Jong;Hyun Dae-Wan;Kang Chi-Ho;Ahn Sang-Il;Kim Eun-Kyu
    • Proceedings of the KSRS Conference
    • /
    • 2005.10a
    • /
    • pp.98-100
    • /
    • 2005
  • This paper describes link analysis on the processed data, HRIT (High Rate Information Transmission) and LRIT (Low Rate Information Transmission), for the preliminary design of interface between COMS (Communication, Ocean and Meteorological Satellite) and ground station. At the MODAC (MeteorologicaVOcean Data Application Center), the processed data are transmitted to user station via COMS with normalization and calibration by pre-processing of MI (Meteorological Imager) data. Due to consider satellite as radio relay, overall analysis containing uplink and downlink is needed. Specific link parameters can be obtained with using the outcomes of SRR (System Requirement Review) which was held on 13-14 June 2005, in Toulouse. From the relation between overall link margin and output power of HPA (High Power Amplifier) of MODAC, it is shown that even though the minimum power related with COMS receiving power range is transmitted at MODAC, the obtained link margin of HRIT could be above 3 dB at user station which antenna elevation angle is 10 degree.

  • PDF

The Performance & Operation Analysis of a Plate Type Reformet for 2 kW Class MCFC Stack (2 kW급 MCFC용 평편형 개질기 운전결과)

  • Seo, Hal-Kung;Ahn, Kyo-Sang;Lim, Hee-Chun;Lee, Sang-Deuk
    • Journal of Hydrogen and New Energy
    • /
    • v.13 no.2
    • /
    • pp.159-167
    • /
    • 2002
  • The operation results of the 2kW class plate type reformer, which has several advantages compared with the tubular burner type reformer, are analyzed. This plate type reformer is composed of six combustion chambers and five reforming chambers by turns. The methane conversion rate at 1.6 absolute pressure is about 84%, which is reasonably similar to theoretical value, 85.3%. Though the abrupt interruption was made just by the carbon deposition during heating the fuel line to combustion chambers around 200 hours operation, the overall steady state operation is more than 450 hours. These operation results show the verification of long run performance and the possibility of direct connection between plate reformer and fuel cell stack.

EXTENSION OF OPERATIONAL LIFE-TIME OF WWER-440/213 TYPE UNITS AT PAKS NUCLEAR POWER PLANT

  • Katona, Tamas Janos;Ratkai, Sandor
    • Nuclear Engineering and Technology
    • /
    • v.40 no.4
    • /
    • pp.269-276
    • /
    • 2008
  • Operational license of WWER-440/213 units at Paks NPP, Hungary is limited to the design lifetime of 30 years. Prolongation by additional 20 years of the operational lifetime is feasible. Moreover, enhancement of the reactor thermal power by 8% will increase both the net power output and the competitiveness of the plant. Paks NPP is a pioneer considering the power up-rate and preparation of long-term operation of WWER-440/213 design. Systematic preparatory work for long-term operation of Paks NPP has been started in 2000. A regulatory framework and a comprehensive engineering practice have been developed. According to the authors view, creation of a gapless engineering system via consequent application of best practices, and feed-back of experiences together with proper consideration of WWER-440/V213 features are the decisive elements of ensuring the safety of long-term operation. That systematic engineering approach is in the focus of recent paper. Key elements of justification and measures for ensuring the safety of long-term operation of Paks NPP WWER-440/213 units are identified and discussed. These are the assessment of plant condition and review of adequacy of ageing management programmes, also the review, validation and reconstitution of time limited ageing analyses as core tasks of licence renewal.

A Study on the Performance Characteristics of an Absorption Chiller for Variable Cooling Water Flow Rate at Partial Load Conditions (흡수식 냉온수기의 부분부하에 따른 냉각수 변유량시 성능특성에 관한 연구)

  • 박찬우;조현철;강용태
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.1
    • /
    • pp.26-33
    • /
    • 2004
  • In general, an absorption chiller or heat pump is operated under the constant cooling water flow rate condition even though the system works with a partial load. The objective of this paper is to study the effect of the cooling water flow rates and the temperature of cooling water on the system performance to find the energy saving methode for the partial load operation of the double effect $H_2O$/LiBr absorption chiller. It is found that the performance of the system is sensitive to the temperature of cooling water than the cooling water flow rate, so the decrease of the performance due to reducing the cooling water flow rate can be overcome with the reduction of the cooling water temperature by 1$^{\circ}C$. The flow rate of the cooling water flow rate ranges from 50% to 100% of the flow rate at normal conditions with a partial load. It is also found that the operation cost of the cooling water pump and the cooling tower can be reduced by 23%.

Determination of the Optimum Feed Rate by a Surface Roughness Model in a Face Milling Operation (표면노조 모델을 이용한 졍면밀링에서의 최적 이송속도 선정)

  • Baek, Dae-Kyun;Ko, Tae-Jo;Kim, Hee-Sool
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.20 no.8
    • /
    • pp.2508-2515
    • /
    • 1996
  • Determination of an optimal feed rate is valuable in the sense of the precision and efficient machining. In this regard, a new surface roughness model for the face milling operation that considered the radial and axal runouts of the inserts in the cutter body was developed. The validity of the model was proved through the cutting experiments, and the model is able to predict the real machined surface roughness exactly with the information of the insert runouts and the cutting conditions. From the estimated surface roughness value, the maximum feed rate that obtains a maximum naterial removal rate under the given surface roughness constraint can be selected by using a bisection method. Therefore, this mehod for optimizing the feed rate can be well applied to the using a bisection method. Therefore, this method for optimizing the feed rate can be well applied to the using selsction of the cutting condition during the NC data generation in CAM.

Power-Efficient Rate Allocation of Wireless Access Networks with Sleep-Operation Management for Multihoming Services

  • Lee, Joohyung;Yun, Seonghwa;Oh, Hyeontaek;Newaz, S.H. Shah;Choi, Seong Gon;Choi, Jun Kyun
    • Journal of Communications and Networks
    • /
    • v.18 no.4
    • /
    • pp.619-628
    • /
    • 2016
  • This paper describes a theoretical framework for rate allocation to maximize the power efficiency of overall heterogeneous wireless networks whose users are assumed to have multihoming capabilities. Therefore, the paper first presents a power consumption model considering the circuit power and radio transmission power of each wireless network. Using this model, two novel power efficient rate allocation schemes (PERAS) for multihoming services are proposed. In this paper, the convex optimization problem for maximizing the power efficiency over wireless networks is formulated and solved while guaranteeing the required quality of service (QoS). Here, both constant bit rate and variable bit rate services are considered. Furthermore, we extend our theoretical framework by considering the sleep-operation management of wireless networks. The performance results obtained from numerical analysis reveal that the two proposed schemes offer superior performance over the existing rate allocation schemes for multihoming services and guarantee the required QoS.

Effects of Secondary Left-sided Portal Hypertension on the Radical Operation Rate and Prognosis in Patients with Pancreatic Cancer

  • Zhang, Shuo;Wen, Dong-Qing;Kong, Ya-Lin;Li, Ya-Li;Zhang, Hong-Yi
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.5
    • /
    • pp.2239-2244
    • /
    • 2014
  • Objective: To investigate the effects of secondary left-sided portal hypertension (LSPH) on the radical operation rate of patients with pancreatic cancer and systemically evaluate the prognosis of patients with LSPH secondary to pancreatic cancer after radical surgery. Materials and Methods: The data of patients with pancreatic cancer who underwent laparotomy over a 15-year period in Department of Hepatobiliary Surgery of Chinese PLA Air Force General Hospital from Jan. 1, 1997, to Jun. 30, 2012 was retrospectively reviewed. Results: A total of 362 patients with pancreatic cancer after laparotomy were selected, including 73 with LSPH and 289 without LSPH. Thirty-five patients with LSPH (47.9%) and 147 without non-LSPH (50.9%) respectively underwent radical operations. No significant difference was found between these two groups regarding the total resection rate and stratified radical resection rate according to different pathological types and cancer locations. The mean and median survival time of patients after radical operation in LSPH group were $13.9{\pm}1.3$ months and 14.8 months, respectively, while those in non-LSPH group were $22.6{\pm}1.4$ months and 18.4 months, respectively(P<0.05). Conclusions: Radical operations for pancreatic cancer and secondary LSPH are safe and effective. Because high-grade malignancy and poor prognosis are closely associated, the decision for radical surgery should be made more meticulously for the patients with pancreatic cancer.

Experimental Studies on Induced Traumatic Pericarditis and Myocarditis in Ruminants (반추수(反芻獸)의 창상성심낭심근염(創傷性心囊心筋炎)에 관(關)한 실험적연구(實驗的硏究))

  • Cheong, C.K.;Nam, T.C.;Seung, J.K.;Oak, J.W.
    • Korean Journal of Veterinary Research
    • /
    • v.20 no.2
    • /
    • pp.127-134
    • /
    • 1980
  • This study was performed to obtain an accurate methods of diagnosis in early stage of traumatic pericarditis and myocarditis in ruminants. Korean native goats were used as experimental animal and traumatic pericarditis and myocarditis were induced by surgical intervention. The changes in clinical signs, hematological values, blood enzymes and electrocardigrams were observed for 14 days after operation. The results obtained were as follows: 1. Body temperature in experimental group of induced traumatic pericarditis and myocarditis was slightly increased than control group that was rumenotomized. Heart rate was increased in both groups but the increased rate was noticed remarkably in experimental group. There was no change in respiratory rate in experimental and control group. 2. Total leucocytes counts and neutrophil percentage maintained higher level after operation and lymphocytes percentage noticed reversed proportion to neutrophil in both groups. 3. Serum total protein concentration and alkaline phosphatase activities after operation showed a little lower levels than these values prior to operation. Serum glutamic oxaloacetic transaminase and lactic dehydrogenase activities in control group showed slight increase through all the experimental period, while in experimental group these activities were markedly elevated and an increase in serum lactic dehydrogenase activities was more remarkable comparing to serum glutamic oxaloacetic transaminase. 4. Electrocardiograms in control group did not show any abnormalities except for slight increase in heart rate. In experimental group the amplitude of QRS complex was increased in duration of experimental period. The transference from QRS complex to T wave was uncertain and S-T segment moved upward obliquely through electrical zero line.

  • PDF

Biological Fixation of $CO_2$ by Chlorella sp. HA-1 in a Semi-Continuous and Series Reactor System

  • LEE JAE-YOUNG;KWON TAE-SOON;BAEK KITAE;YANG JI-WON
    • Journal of Microbiology and Biotechnology
    • /
    • v.15 no.3
    • /
    • pp.461-465
    • /
    • 2005
  • Characteristics of biological $CO_2$ fixation by Chlorella sp. HA-1 were investigated in a semi-continuous and series reactor system using an internally illuminated photobioreactor to overcome shortcomings of physicochemical technologies such as adsorption and membrane separation. High $CO_2$ fixation rate was achieved in the semi-continuous reactor system, in which the dilution ratios of the culture medium were controlled. The average $CO_2$ fixation rate was maintained almost constantly when the dilution ratio increased by 0.1 increment from the initial value of 0.5. The total removal efficiency of $CO_2$ was enhanced by employing a series reactor system. The average $CO_2$ fixation rate increased until 4.013 g $CO_2\;day^{-1}$ in a series operation of four reactors, compared to 0.986 g $CO_2\;day^{-1}$ in a batch operation mode. The total $CO_2$ fixation rate was proportional to the number of reactors used in the series reactor system. In the series reactor system of semi-continuous operation, a large amount of $CO_2$ was removed continuously for 30 days. These results showed that the present reactor systems are efficient and economically feasible for a biological $CO_2$ fixation.