• 제목/요약/키워드: Operation Condition

검색결과 4,081건 처리시간 0.033초

Analysis, Design, and Implementation of a Soft-Switched Active-Clamped Forward Converter with a Current-Doubler Rectifier

  • Jang, Paul;Kim, Hye-Jin;Cho, Bo-Hyung
    • Journal of Power Electronics
    • /
    • 제16권3호
    • /
    • pp.894-904
    • /
    • 2016
  • This study examines the zero-voltage switching (ZVS) operation of an active-clamped forward converter (ACFC) with a current-doubler rectifier (CDR). The ZVS condition can be obtained with a much smaller leakage inductance compared to that of a conventional ACFC. Due to the significantly reduced leakage inductance, the design is optimized and the circulating loss is reduced. The operation of the ACFC with a CDR is analyzed, and a detailed ZVS analysis is conducted on the basis of a steady-state analysis. From the results, a design consideration for ZVS improvement is presented. Loss analyses of the converters shows that enhanced soft-switching contributes to an efficiency improvement under light-load condition. Experimental results from a 100-W (5-V/20-A) prototype verify that the ACFC with a CDR can attain ZVS across an extended load range of loads and achieve a higher efficiency than conventional ACFCs.

하나로 핵연료 시험장치의 주냉각수 계통 상온기능시험 (The Cold Function Test of a Main Cooling Water System for a Nuclear Fuel Test Loop Installed in HANARO)

  • 박용철;이용섭;지대영
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.2505-2510
    • /
    • 2008
  • A nuclear fuel test loop (after below, FTL) is installed in IR1 of an irradiation hole in HANARO for testing neutron irradiation characteristics and thermo hydraulic characteristics of a fuel loaded in a light water power reactor or a heavy water power reactor. When HANARO is normally operated, the fuel loaded in the irradiation hole has a nuclear reaction heat generated by a neutron irradiation. To remove the generated heat and to maintain an operation condition of the test fuel, a main cooling water system (MCWS) is installed in the OPS of the FTL. This paper describes the cold function test results of the MCWS. It was confirmed through the test results that the system met the design requirements under a cold operation condition.

  • PDF

연속 광조사 조건에서의 태양전지모듈의 연간 최대출력 저하율 변화 예측 분석 (Analysis of Maximum Generating Power Drop of PV Module Under the Continuous Artificial Light Irradiation Test Condition)

  • 김경수;윤재호
    • Current Photovoltaic Research
    • /
    • 제6권3호
    • /
    • pp.69-73
    • /
    • 2018
  • PV system is consisted with PV module, inverter and BOS(balance of system). To have robustic operation more than 20 years, the expected and guaranteed durability and reliability of products should be met. Almost components of PV system are qualified through IEC standards at test laboratory. But the qualification certificate of product does not ensure long-term nondefective operation. PV module's expected life time is nowadays more than 20 years and annual maximum power degradation ratio would be less than -1%. But the power degradation ratio is basically based on real data more than several years' record. Developing test method for ensuring annual maximum power degradation ratio is very need because there are many new products every month with new materials. In this paper, we have suggested new test method under continuous artificial light irradiation test condition for analyze expected maximum power drop ratio.

Real-time Tool Condition Monitoring for Machining Operations

  • Kim, Yon-Soo
    • 산업공학
    • /
    • 제7권3호
    • /
    • pp.155-168
    • /
    • 1994
  • In computer integrated manufacturing environment, tool management plays an important role in controlling tool performance for machining operations. Knowledge of tool behavior during the cutting process and effective tool-behavior prediction contribute to controlling machine costs by avioding production delays and off-target parts due to tool failure. The purpose of this paper is to review and develop the tool condition monitoring scheme for drilling operation to assure a fast corrective response to minimize the damage if tool failures occur. If one desires to maximize system through-put and product quality as well as tooling resources, within an economic environment, real-time tool sensing system and information processing system can be coupled to provide the necessary information for the effective tool management. The example is demonstrated as to drilling operation when the aluminum composites are drilled with carbide-tipped HSS drill bits. The example above is limited to the situation that the tool failure mode of drill bits is wear.

  • PDF

전압원 멀티레벨 컨버터 밸브 시험회로 연구 (Voltage source multilevel module converter valve test circuit research)

  • 원진;이진희;정택선;백승택
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2014년도 전력전자학술대회 논문집
    • /
    • pp.79-80
    • /
    • 2014
  • Voltage source multilevel module converter attracts more and more attention recently. The core component of the voltage source multilevel module converter is the valve based on IGBT. So the test circuit for the valve is very important, reliable test method can guarantee the converter valve design meet the operation requirement. This paper analyzes the valve voltage and current stress during the operation, and according to IEC standard test requirement, object, condition, introduces a kind of test circuit. Finally, through the simulation model, to verify the test circuit can provide the proper test condition for the voltage source multilevel module converter valve.

  • PDF

A Study on the Influence of Navigational Environment on Mariner's Behavior for Collision Avoidance

  • Park, Jung-Sun;Yea, Byeong-Deok
    • 한국항해항만학회지
    • /
    • 제32권2호
    • /
    • pp.127-132
    • /
    • 2008
  • The safety degree of navigation for collision avoidance is closely related with the combination between mariner's behavior and navigational environment. The condition of navigational environment is mainly decided by navigable waters, ship traffic, rule of road, sea state, weather and so on. Especially, the condition of navigable waters and ship traffic in navigational environment are ones of the important factors to attain safe navigation when mariners are underway and crossing, head on or overtaking situation. Thus this paper is to analyze the characteristics of mariner's behavior for collision avoidance caused by ship traffic and navigable waters by analyzing the contents of questionnaire and the results of international collaborative research. As a result, it can be concluded that the density of ship traffic and the area of navigable waters affect mariner's ship handling for collision avoidance.

전기에너지주택의 유동적인 실험환경을 고려한 가전기기 제어 시뮬레이션 방안에 관한 연구 (A Study on the Control Simulation Method of Home Appliances Considering the Flexible Experimental Condition of All-Electrified Houses)

  • 황성욱;김강식;나환선;조병옥
    • 한국기계기술학회지
    • /
    • 제13권1호
    • /
    • pp.57-64
    • /
    • 2011
  • Recently, all-electrified houses have constructed and some tasks are being carried out to monitor energy consumption patterns. The energy monitoring includes various elements such as temperature, pressure, water flow, $CO_2$, and electricity. In this monitoring, electricity consumption is one of the essential factors because the performance and energy saving levels are described by this physical quantity. This quantity depends on materials, structure, operation of the house, which operation means consumer's life style and usage patterns of home appliances furthermore. Firstly, this paper shows a control simulation method which were developed a few years ago. And some different methods are proposed considering flexible experimental condition.

Clearance Variation Effects on Micro Wave Rotor Operation

  • Okamoto, Koji;Yamaguchi, Kazuo
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2008년 영문 학술대회
    • /
    • pp.855-861
    • /
    • 2008
  • Micro wave rotor is expected to improve the performance of micro gas turbines drastically. In the present study, a micro wave rotor test rig was designed and built for micro gas turbines of 1-10 kW output range, and its test runs were carried out with cold air flow. In the previous experiments, the leakage loss had large influence on its operating condition. Therefore, abradable coating was applied on the end walls to achieve the operation with zero clearance for leakage reduction and its improvement on the operating condition is discussed in this study.

  • PDF

철도운영회사의 모니터 제도 운영 현황 및 개선 방향 (Present condition and Improvement of Citizen Monitor System of Railway Operation Companies)

  • 한우진;박정수
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 추계학술대회 논문집
    • /
    • pp.770-775
    • /
    • 2008
  • Currently most domestic passenger railway transportation companies are operating citizen monitor system. The citizen monitor is the system to grasp the passengers' inconvenience and proposals in depth and to collect improvement methods based on those. But the present citizen monitor system has little difference from general complaint processing system, so it is necessary to improve to correspond its original purpose. Therefore in this paper, based on my citizen monitor experience of many years and literature investigation, I will summarize present condition of the operation of citizen monitor system, grasp its problems and propose improvement point of citizen monitor system. By these improvement, the effectiveness of citizen monitor system per expense will increase, and ultimately it can be contributed to public relations and service advancement of railway operating companies.

  • PDF

전류형 Z-Source 컨버터를 이용한 새로운 LED 전류 밸런싱 기법 (New LED Current Balancing Scheme Using C-Fed Z-Source Converter)

  • 홍다헌;차헌녕
    • 전력전자학회논문지
    • /
    • 제26권1호
    • /
    • pp.9-15
    • /
    • 2021
  • In multi-string light-emitting diode (LED) driver system, current balancing is crucial because the brightness of LED is directly related to its forward current. This paper presents a novel LED current balancing topology using current-fed Z-source converter. With the proposed structure, currents flowing through two LED strings are automatically balanced owing to the charge-balance condition on capacitors. Operation of the proposed converter is simple and the proposed converter uses only one active switch and one diode. Moreover, low-side gate driving can be used to operate the active switch. To verify the operation of the proposed LED current balancing converter, a prototype is built and tested with different numbers of LEDs.