• 제목/요약/키워드: Operating limit

검색결과 519건 처리시간 0.026초

가솔린 예혼합 압축 착화 엔진의 농후 한계에서 연소와 노킹 특성 (Knocking and Combustion Characteristics at Rich Limit of Gasoline HCCI Engine)

  • 염기태;장진영;배충식
    • 한국자동차공학회논문집
    • /
    • 제14권6호
    • /
    • pp.9-16
    • /
    • 2006
  • Variable valve timing is one of the attractive ways to control homogeneous charge compression ignition (HCCI) engine. Hot internal residual gas which can be controlled by variable valve timing(VVT) device, makes fuel evaporated easily, and ignition timing advanced. Regular gasoline was used as main fuel and di-methyl ether(DME) was used as ignition promoter in this research. HCCI engine operating range is limited by high combustion peak pressure and engine noise. High combustion pressure can damage the engine during operation. To avoid engine damage, the rich limits have to define using various methods. Peak combustion pressure, rate of cylinder pressure rise was considered to determine rich limit of engine operating range. Knock probability was correlated with the rate of cylinder pressure rise as well as the peak combustion pressure.

吸氣冷却-蒸氣噴射 가스터빈 사이클에 관한 열역학적 연구 (A Thermodynamic Study on Suction Cooling-Steam Injected Gas Turbine Cycle)

  • 박종구;양옥룡
    • 대한기계학회논문집
    • /
    • 제16권1호
    • /
    • pp.77-86
    • /
    • 1992
  • 본 연구에서는 사이클은 터빈 출구로 부터 배출되는 폐열을 최대한 회수하여 얻은 증기를 연소기내에 분사시킴으로써 부가적인 압축기 및 비출력의 상향을 기할수 있다.아울러 폐열이용 암모니아 흡수기 냉동기를 구동하여 압축기 입구 온도를 낮 춤에 의해 열효율 및 비출력의 증대는 물론 대기온도 변화에 따른 기관 성능의 변동을 감소시킬 수 있다.

345kV 고장전류 저감을 위한 한류리액터 설치시 차단기 TRV(근거리 고장시) 검토 (A Study on the TRV(SLF) of Circuit Breakers According to Install Current Limit Reactors)

  • 박흥석;곽주식;주형준;유희영;한상옥
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 A
    • /
    • pp.371-373
    • /
    • 2005
  • An enhancement for a transmission and substation equipment in power system make the system impedance to be lower. In principle, if the system impedance become low, system stability will be better, but the fault current become very higher. It is a very big problem for CB operating. As a fact of CB operating performance, high amplitude of the fault current may cause CB operation failure because of exceeding standard value in TRV. So we simulated TRV by using the EMTP. Generally there are two types of TRV in actual power system. One is short line fault, the other is bus terminal fault. In this paper, we simulated the TRv at short line fault as installed current limit reactors to reduce fault current in 345kV ultra-high voltage system. Short line fault is caused from single line fault in transmission line.

  • PDF

하이브리드 유전 알고리즘을 이용한 시간제약이 있는 군수 드론 및 수송 UGV 혼합배송 문제 연구 (Study on Delivery of Military Drones and Transport UGVs with Time Constraints Using Hybrid Genetic Algorithms)

  • 이정훈;김수환
    • 한국군사과학기술학회지
    • /
    • 제25권4호
    • /
    • pp.425-433
    • /
    • 2022
  • This paper studies the method of delivering munitions using both drones and UGVs that are developing along with the 4th Industrial Revolution. While drones are more mobile than UGVs, their loading capacity is small, and UGVs have relatively less mobility than drones, but their loading capacity is better. Therefore, by simultaneously operating these two delivery means, each other's shortcomings may be compensated. In addition, on actual battlefields, time constraints are an important factor in delivering munitions. Therefore, assuming an actual battlefield environment with a time limit, we establish delivery routes that minimize delivery time by operating both drones and UGVs with different capacities and speeds. If the delivery is not completed within the time limit, penalties are imposed. We devised the hybrid genetic algorithm to find solutions to the proposed model, and as results of the experiment, we showed the algorithm we presented solved the actual size problems in a short time.

Improvement in Efficiency and Operating Range of Centrifugal Blower Stage for Sewage Aeration Blower

  • Hiradate, Kiyotaka;Kanno, Toshio;Nishida, Hideo;Shinkawa, Yasushi;Joukou, Satoshi
    • International Journal of Fluid Machinery and Systems
    • /
    • 제3권4호
    • /
    • pp.379-385
    • /
    • 2010
  • We developed a high-efficiency, wide-operating-range centrifugal blower stage to meet the demand for reduced total energy-consumption in sewage treatment plants. We improved the efficiency of the two-dimensional impeller using a shape optimization tool and one-dimensional performance prediction tool. A limit of the throat deceleration ratio was set to maintain the stall-margin of the impeller. The low solidity vaned diffuser and return channel were designed using a sensitivity analysis with orthogonal arrays and three-dimensional steady flow simulations. The low solidity diffuser was designed in order to improve the performance in the low-flow-rate region. The return channel was designed so that the total pressure loss in the return channel was minimized. Model tests of both the conventional and optimized blower stages were carried out, and the efficiency and operating range of both stages were compared. The optimized blower stage improved in stage efficiency by 3% and in operating range by 5% compared with the conventional blower stage.

Economic Dispatch Using Hybrid Particle Swarm Optimization with Prohibited Operating Zones and Ramp Rate Limit Constraints

  • Prabakaran, S.;Senthilkuma, V.;Baskar, G.
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권4호
    • /
    • pp.1441-1452
    • /
    • 2015
  • This paper proposes a new Hybrid Particle Swarm Optimization (HPSO) method that integrates the Evolutionary Programming (EP) and Particle Swarm Optimization (PSO) techniques. The proposed method is applied to solve Economic Dispatch(ED) problems considering prohibited operating zones, ramp rate limits, capacity limits and power balance constraints. In the proposed HPSO method, the best features of both EP and PSO are exploited, and it is capable of finding the most optimal solution for the non-linear optimization problems. For validating the proposed method, it has been tested on the standard three, six, fifteen and twenty unit test systems. The numerical results show that the proposed HPSO method is well suitable for solving non-linear economic dispatch problems, and it outperforms the EP, PSO and other modern metaheuristic optimization methods reported in the recent literatures.

독립형 태양광 인버터의 병렬 운전 기법 (Parallel operating technique for the stand alone PV PCS)

  • 정구인;권정민
    • 한국태양에너지학회 논문집
    • /
    • 제35권6호
    • /
    • pp.9-15
    • /
    • 2015
  • In this paper, a parallel operating technique for the stand alone photovoltaic (PV) power conditioning system (PCS) is proposed. The proposed parallel operating technique can increase the power rating of the system easily. Also, it provide three-phase connection function. The proposed technique does not separated master and slave system. Also, it does not use the separated synchronization line. Therefore, the PCS can supply continuous power even if one of the PCS breaks down. This technique is composed of a phase locked loop (PLL) control, droop control, current limit control and etc. Experimental result obtained on 2-kW prototype to verify the proposed technique.

Analysis of V2V Broadcast Performance Limit for WAVE Communication Systems Using Two-Ray Path Loss Model

  • Song, Yoo-Seung;Choi, Hyun-Kyun
    • ETRI Journal
    • /
    • 제39권2호
    • /
    • pp.213-221
    • /
    • 2017
  • The advent of wireless access in vehicular environments (WAVE) technology has improved the intelligence of transportation systems and enabled generic traffic problems to be solved automatically. Based on the IEEE 802.11p standard for vehicle-to-anything (V2X) communications, WAVE provides wireless links with latencies less than 100 ms to vehicles operating at speeds up to 200 km/h. To date, most research has been based on field test results. In contrast, this paper presents a numerical analysis of the V2X broadcast throughput limit using a path loss model. First, the maximum throughput and minimum delay limit were obtained from the MAC frame format of IEEE 802.11p. Second, the packet error probability was derived for additive white Gaussian noise and fading channel conditions. Finally, the maximum throughput limit of the system was derived from the packet error rate using a two-ray path loss model for a typical highway topology. The throughput was analyzed for each data rate, which allowed the performance at the different data rates to be compared. The analysis method can be easily applied to different topologies by substituting an appropriate target path loss model.

기계적 접점을 이용한 FCL의 동작 특성 (Operational Characteristics of the FCL Using the Mechanical Contact in the Power System)

  • 정병익;최효상
    • 전기학회논문지
    • /
    • 제65권5호
    • /
    • pp.878-882
    • /
    • 2016
  • These days, SFCLs are being developed in order to limit fault current. However, the superconducting elements that limit the fault current have such problems as capacity increase and require auxiliary devices including cooling device. If devices that comprise the current power network can withstand fault current for at least one cycle, it is possible to limit the fault current with current limiting elements by bypassing it on the fault line. In this study, the fault current limiter was configured with current transformer, vacuum interrupter, and current limiting element. Through the experience, it was confirmed that the fault current was limited within one cycle. The superconducting element, as a current limiting element, limited the fault current by 80 % within one cycle from fault occurrence, and the passive element limited it more than 95 %. Also, through the comparison between resistance curve and power consumption curve, it was confirmed that the current limiting element using a passive element was more stable than the superconducting element that required capacity increase and other auxiliary devices. It was considered that the FCL proposed in this study could limit fault current stably within one cycle from fault occurrence by using the existing power technologies such as fault current detection and solenoid valve operating circuit.

원자로 운전을 위한 압력/온도 한계곡선의 설정 (Generation of Pressure/Temperature Limit Curve for Reactor Operation)

  • 정명조;박윤원
    • 전산구조공학
    • /
    • 제10권4호
    • /
    • pp.155-164
    • /
    • 1997
  • 핵분열로 인한 고온, 고압의 냉각수를 유지하는 원자로 용기는 원자로의 냉각 또는 가열시 압력에 의한 응력과 함께 열응력이 가해지고 원자로 벽의 온도변화에 따라 파괴인성치가 변화하기 때문에 임의의 결함이 존재할 경우 건전성 확보가 쉽지 않다. 따라서 가상결함이 성장하지 않도록 압력과 온도를 조정하면서 냉각 및 가열시킬 필요가 있다. 본 연구에서는 원자로 운전 중 냉각 및 가열시 안전하게 운전하기 위한 압력/온도 한계곡선을 구하는 절차에 필요한 이론을 조사하였고 이의 도출을 위한 해석과정을 전산화하였다. 국내원전 중 가장 오래된 고리 1호기에 대한 압력/온도 한계곡선을 다양한 냉각 및 가열률에 따라 설정하였고 이들 결과를 검토하였다.

  • PDF