• 제목/요약/키워드: Operating Status

검색결과 974건 처리시간 0.028초

차단기 감시제어용 디지털 시스템에 관한 연구 (A Study on the Digital System for Supervisory Control of the Circuit Breakers)

  • 이성환
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제52권3호
    • /
    • pp.143-150
    • /
    • 2003
  • In this paper, we developed the window based monitoring system. This system offers the analysis of accidents in the power plants, the operating status of relays and the historical data with which the experts can offer the idea about the operation of the power system. And we can also monitor the status of the ACB and relay at a long distance by means of the function of communication in the digital protective relay itself. By means of the above functions, we developed the system, which is run after the diagnosis and maintenance of the electrical machines and an amount of data are realized by graphical method fitting the operating convenience of the users.

60GHz Wi-Fi 현황 및 전망 (Current Status and Prospects of 60 GHz Wi-Fi (WiGig))

  • 김항석;최새솔;송영근
    • 전자통신동향분석
    • /
    • 제33권2호
    • /
    • pp.30-38
    • /
    • 2018
  • Wi-Fi is a technology that has become an essential part of our lives, and not simply a convenience. Wi-Fi is mainly used indoors and is evolving in terms of an increase in the transmission speed and expanded coverage. 802.11ac Wi-Fi, operating at 5 GHz, and 802.11ad Wi-Fi, operating at 60 GHz, were standardized in the same year, 2012, as a gigabit-transmission speed Wi-Fi technology. In this article, we examine the current status of the Wi-Fi market trends and present the possibility of the development of 60 GHz Wi-Fi and future market prospects.

볼베어링으로 지지된 회전축의 이상상태 진단을 위한 진단전문가 시스템의 개발 (Development of Diagnostic Expert System for Rotating Machinery Failure Diagnosis)

  • 유송민;김영진;박상신
    • 한국정밀공학회지
    • /
    • 제15권11호
    • /
    • pp.218-226
    • /
    • 1998
  • In this study a neural network based expert system designed to diagnose operating status of a rotating spindle system supported by ball bearings was introduced. In order to facilitate practical failure situations, five exemplary abnormal status was fabricated. Out of several possible data source locations, seven most effective spots were chosen and proven to be the most successful in predicting single and multiple abnormalities. Increased signal strength was measured around where abnormality was embedded. Signal mea-surement locations producing high prediction rate were also classified. Even though multiple abnormalities were hard to be decoupled into their individual causes, proposed diagnostic system was somewhat effective in predicting such cases under certain combination of sensor locations. Among several abnormal operating conditions, highest prediction rate can be expected when signal is spoiled by the failure or damage in outer race. Proposed diagnostic system was again proven to be the most effective system in analyzing and ranking the importance of data sources.

  • PDF

Mobile IP 세대를 대비한 VMware 기반의 바이러스 Test bed (Virus Test bed using VMware in Preparation for the Mobile IP Generation)

  • 김홍일
    • 한국산업정보학회논문지
    • /
    • 제14권1호
    • /
    • pp.56-63
    • /
    • 2009
  • Mobile IP 단말기들에 탑재되는 운영체제는 일반적인 PC에서 탑재되는 운영체제와는 달리 확실한 독점체제가 확립되지 않은 상태이다. 따라서 당분간 Mobile IP 단말기에 운영되는 운영체제는 다양한 종류의 운영체제가 사용될 것으로 추정된다. 이러한 환경은 운영체제에 상관없이 변종되는 바이러스들에 매우 취약한 환경이며, 개별 단말기에서 사용되는 운영체제가 다양하기 때문에 이들 바이러스를 효율적으로 검출하여 치료하는 기술 개발을 매우 난해하게 한다. 본 논문에서는 VMware를 이용하여 다양한 운영체제에서 변종 바이러스를 테스팅할 수 있는 시스템을 설계하고 구현하였다. 또한 이를 실제 Mobile 환경에서 운영하기 위한 Prototype 시스템을 구축하였다.

Development of Advanced Annunciator System for Nuclear Power Plants

  • Hong, Jin-Hyuk;Park, Seong-Soo;Chang, Soon-Heung
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1995년도 추계학술발표회논문집(1)
    • /
    • pp.185-190
    • /
    • 1995
  • Conventional alarm system has many difficulties in the operator's identifying the plant status during special situations such as design basis accidents. To solve the shortcomings, an on-line alarm annunciator system, called dynamic alarm console (DAC), was developed. In the DAC, a signal is generated as alarm by the use of an adaptive setpoint check strategy based on operating mode, and time delay technique is used not to generate nuisance alarms. After alarm generation, if activated alarm is a level precursor alarm or a consequencial alarm, it would be suppressed, and the residual alarms go through dynamic prioritization which provide the alarms with pertinent priorities to the current operating mode. Dynamic prioritization is achieved by going through the system- and mode-oriented prioritization. The DAC has the alarm hierarchical structure based on the physical and functional importance of alarms. Therefore the operator can perceive alarm impacts on the safety or performance of the plant with the alarm propagation from equipment level to plant functional level. In order to provide the operator with the most possible cause of the event and quick cognition of the plant status even without recognizing the individual alarms, reactor trip status tree (RTST) was developed. The DAC and the RTST have been simulated with on-line data obtained from the full-scope simulator for several abnormal cases. The results indicated that the system can provide the operator with useful and compact information fur the earlier termination and mitigation of an abnormal state.

  • PDF

스마트TV를 활용한 지능형 생산현황판 개발에 관한 연구 (A study on development of the intelligent production status boards using Smart TV)

  • 조용욱;심진범
    • 대한안전경영과학회지
    • /
    • 제14권3호
    • /
    • pp.277-282
    • /
    • 2012
  • A Smart TV device is either a television set with integrated internet capabilities or a set-top box for television that offers more advanced computing ability and connectivity than a contemporary basic television set. In recent years, there has been a popularity rose up on Smart TV (Smart Television) usage at home. This paper present the intelligent production status boards using features and functions of smart TV in shop floor. With the proposed status boards, we can reduce installation and operating costs of the existing production status boards. In addition, This article present the system that can line monitoring without equipments as CC TV.

군병원 수술부의 건축적 특성에 관한 연구 - 통합병원의 이용실태를 중심으로 - (A Study on the Architectural Characteristics of the Operating Department in Army Hospitals - Focused on the Utilization of A.F.M.H. -)

  • 권오봉;박재승
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제5권9호
    • /
    • pp.61-68
    • /
    • 1999
  • The purpose of this study was to get the design guidelines of the operating department in army hospital. New A.F.M.H. is now under construction but army hospital's characteristics are not reflected. This research is accomplished through an understanding of the characteristics of operating department in army hospitals by analyzing the plans and behavior survey of some A.F.M.H. This study attempts to examine the current status of domestic army medical center and to establish the design guideline of the operating department of the army hospitals.

  • PDF

초기 운전점 선정을 통한 배전계통 최적 재구성에 관한 연구 (A study of Optimal Reconfiguration in Distribution Power System using Initial Operating Point)

  • 서규석;김정년;백영식
    • 전기학회논문지
    • /
    • 제56권3호
    • /
    • pp.451-456
    • /
    • 2007
  • This paper presents a problem that reconfigure distribution power system using branch exchange method. Optimal reconfiguration problem calculates line loss, voltage condition about system states of all situations that become different according to line On/off status, and search for optimum composition of these. However, result is difficult to be calculated fast. Because radiated operation condition of system is satisfied using many connection and sectionalize switches in the distribution power system. Therefore, in this paper, optimization method for reducing system total loss and satisfying operating condition of radial and constraints condition of voltage is proposed using the fastest branch exchange. And optimal solution at branch exchange algorithm can be wrong estimated to local optimal solution according to initial operating state. Considering this particular, an initial operating point algorithm is added and this paper showed that optimal solution arrives at global optimal solution.