• Title/Summary/Keyword: Operating Status

Search Result 957, Processing Time 0.034 seconds

A Study on the Digital System for Supervisory Control of the Circuit Breakers (차단기 감시제어용 디지털 시스템에 관한 연구)

  • 이성환
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.52 no.3
    • /
    • pp.143-150
    • /
    • 2003
  • In this paper, we developed the window based monitoring system. This system offers the analysis of accidents in the power plants, the operating status of relays and the historical data with which the experts can offer the idea about the operation of the power system. And we can also monitor the status of the ACB and relay at a long distance by means of the function of communication in the digital protective relay itself. By means of the above functions, we developed the system, which is run after the diagnosis and maintenance of the electrical machines and an amount of data are realized by graphical method fitting the operating convenience of the users.

Current Status and Prospects of 60 GHz Wi-Fi (WiGig) (60GHz Wi-Fi 현황 및 전망)

  • Kim, H.S.;Choi, S.S.;Song, Y.K.
    • Electronics and Telecommunications Trends
    • /
    • v.33 no.2
    • /
    • pp.30-38
    • /
    • 2018
  • Wi-Fi is a technology that has become an essential part of our lives, and not simply a convenience. Wi-Fi is mainly used indoors and is evolving in terms of an increase in the transmission speed and expanded coverage. 802.11ac Wi-Fi, operating at 5 GHz, and 802.11ad Wi-Fi, operating at 60 GHz, were standardized in the same year, 2012, as a gigabit-transmission speed Wi-Fi technology. In this article, we examine the current status of the Wi-Fi market trends and present the possibility of the development of 60 GHz Wi-Fi and future market prospects.

Development of Diagnostic Expert System for Rotating Machinery Failure Diagnosis (볼베어링으로 지지된 회전축의 이상상태 진단을 위한 진단전문가 시스템의 개발)

  • 유송민;김영진;박상신
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.15 no.11
    • /
    • pp.218-226
    • /
    • 1998
  • In this study a neural network based expert system designed to diagnose operating status of a rotating spindle system supported by ball bearings was introduced. In order to facilitate practical failure situations, five exemplary abnormal status was fabricated. Out of several possible data source locations, seven most effective spots were chosen and proven to be the most successful in predicting single and multiple abnormalities. Increased signal strength was measured around where abnormality was embedded. Signal mea-surement locations producing high prediction rate were also classified. Even though multiple abnormalities were hard to be decoupled into their individual causes, proposed diagnostic system was somewhat effective in predicting such cases under certain combination of sensor locations. Among several abnormal operating conditions, highest prediction rate can be expected when signal is spoiled by the failure or damage in outer race. Proposed diagnostic system was again proven to be the most effective system in analyzing and ranking the importance of data sources.

  • PDF

Virus Test bed using VMware in Preparation for the Mobile IP Generation (Mobile IP 세대를 대비한 VMware 기반의 바이러스 Test bed)

  • Kim, Hong-Il
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.14 no.1
    • /
    • pp.56-63
    • /
    • 2009
  • Contrast operating system installed on traditional PC, operating system installed to mobile IP host is a status not to be established a definite monopoly system. Accordingly, for the time being, it is expected that operating system operated in mobile IP host will be used various operating systems. Regardless of operating system, this condition is a very vulnerable to modified virus. Because operating system used in an individual host is very diverse, It makes technical development to cure complicated in detection efficiently these virus. In this thesis, By using VMware under the various operating system, I designed and implemented system which is able to test a modified virus. Also I implemented prototype system to operate under the real mobile condition.

Development of Advanced Annunciator System for Nuclear Power Plants

  • Hong, Jin-Hyuk;Park, Seong-Soo;Chang, Soon-Heung
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1995.10a
    • /
    • pp.185-190
    • /
    • 1995
  • Conventional alarm system has many difficulties in the operator's identifying the plant status during special situations such as design basis accidents. To solve the shortcomings, an on-line alarm annunciator system, called dynamic alarm console (DAC), was developed. In the DAC, a signal is generated as alarm by the use of an adaptive setpoint check strategy based on operating mode, and time delay technique is used not to generate nuisance alarms. After alarm generation, if activated alarm is a level precursor alarm or a consequencial alarm, it would be suppressed, and the residual alarms go through dynamic prioritization which provide the alarms with pertinent priorities to the current operating mode. Dynamic prioritization is achieved by going through the system- and mode-oriented prioritization. The DAC has the alarm hierarchical structure based on the physical and functional importance of alarms. Therefore the operator can perceive alarm impacts on the safety or performance of the plant with the alarm propagation from equipment level to plant functional level. In order to provide the operator with the most possible cause of the event and quick cognition of the plant status even without recognizing the individual alarms, reactor trip status tree (RTST) was developed. The DAC and the RTST have been simulated with on-line data obtained from the full-scope simulator for several abnormal cases. The results indicated that the system can provide the operator with useful and compact information fur the earlier termination and mitigation of an abnormal state.

  • PDF

A study on development of the intelligent production status boards using Smart TV (스마트TV를 활용한 지능형 생산현황판 개발에 관한 연구)

  • Cho, Yong-Wook;Sim, Jin-Bum
    • Journal of the Korea Safety Management & Science
    • /
    • v.14 no.3
    • /
    • pp.277-282
    • /
    • 2012
  • A Smart TV device is either a television set with integrated internet capabilities or a set-top box for television that offers more advanced computing ability and connectivity than a contemporary basic television set. In recent years, there has been a popularity rose up on Smart TV (Smart Television) usage at home. This paper present the intelligent production status boards using features and functions of smart TV in shop floor. With the proposed status boards, we can reduce installation and operating costs of the existing production status boards. In addition, This article present the system that can line monitoring without equipments as CC TV.

A Study on the Architectural Characteristics of the Operating Department in Army Hospitals - Focused on the Utilization of A.F.M.H. - (군병원 수술부의 건축적 특성에 관한 연구 - 통합병원의 이용실태를 중심으로 -)

  • Kweon, Oh-Bong;Park, Jae-Seung
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.5 no.9
    • /
    • pp.61-68
    • /
    • 1999
  • The purpose of this study was to get the design guidelines of the operating department in army hospital. New A.F.M.H. is now under construction but army hospital's characteristics are not reflected. This research is accomplished through an understanding of the characteristics of operating department in army hospitals by analyzing the plans and behavior survey of some A.F.M.H. This study attempts to examine the current status of domestic army medical center and to establish the design guideline of the operating department of the army hospitals.

  • PDF

A study of Optimal Reconfiguration in Distribution Power System using Initial Operating Point (초기 운전점 선정을 통한 배전계통 최적 재구성에 관한 연구)

  • Seo, Gyu-Seok;Kim, Jung-Nyun;Baek, Young-Sik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.3
    • /
    • pp.451-456
    • /
    • 2007
  • This paper presents a problem that reconfigure distribution power system using branch exchange method. Optimal reconfiguration problem calculates line loss, voltage condition about system states of all situations that become different according to line On/off status, and search for optimum composition of these. However, result is difficult to be calculated fast. Because radiated operation condition of system is satisfied using many connection and sectionalize switches in the distribution power system. Therefore, in this paper, optimization method for reducing system total loss and satisfying operating condition of radial and constraints condition of voltage is proposed using the fastest branch exchange. And optimal solution at branch exchange algorithm can be wrong estimated to local optimal solution according to initial operating state. Considering this particular, an initial operating point algorithm is added and this paper showed that optimal solution arrives at global optimal solution.