• 제목/요약/키워드: Operating Fluid

검색결과 1,006건 처리시간 0.024초

지열 히트펌프에서 운전변수가 냉난방 성능에 미치는 영향에 대한 실험연구 (An Experimental Study on the Effects of Operating Variables on the Cooling and Heating Performance of Geothermal Heat Pump)

  • 장근선;강희정
    • 설비공학논문집
    • /
    • 제23권8호
    • /
    • pp.562-570
    • /
    • 2011
  • In this research, an experimental study is performed to investigate the effects of system operating variables on the cooling and heating characteristics of heat pump system using geothermal heat source and carbon dioxide as a refrigerant. System variables analyzed include compressor frequency, electronic expansion valve opening, refrigerant charge, secondary fluid temperature and flow rate. Results show that optimum refrigerant charge and electronic expansion valve opening position exist at the maximum point of COP curve, and both cooling and heating capacity increase but COPs decrease with the increase of compressor frequency. The change of a secondary fluid temperature leads to variation of overheat area and enthalpy difference in the evaporator and gas cooler. which again results in considerable variations of cooling and heating capacity and COP. In the case of effects of secondary water fluid flow rate, both cooling capacity and COP increase with the increase of secondary flow in evaporator or gas cooler, whereas heating capacity and COP decrease with the increase of flow rate in gas cooler.

스크린메쉬형 VCHP에서 NCG량에 따른 열전달 성능실험 (Influence of NCG Charged Mass on the Thermal Performance of VCHP with Screen Mesh Wick)

  • 박영식;정경택;서정세
    • 설비공학논문집
    • /
    • 제20권10호
    • /
    • pp.689-695
    • /
    • 2008
  • Experimental study has been performed to investigate the influence of non-condensible gas(NCG) charged mass on the thermal performance of a variable conductance heat pipe(VCHP) with screen mesh wick. The VCHP is furnished by screen mesh number 200 for the pipe outer diameter of 12.7mm and the pipe length of 500 mm. The VCHP is filled with water as working fluid of 4.8g and nitrogen as NCG and has evaporator, condenser and adiabatic section, respectively. For the results from experiment, it is found that, for the same charged mass of working fluid, the overall wall temperatures of heat pipe grows up with increasing NCG charged mass. The variation of operating temperature of VCHP reduces with increasing NCG mass. In addition, the profile of axial wall temperature distribution is presented for heat transport capacity of heat pipe, the temperature of cooling water of condenser, inclination angle, and operating temperature.

FRICTION CHARACTERISTICS OF A PAPER-BASED FRICTION MATERIAL

  • Gao, H.;Barber, G.-C.;Chu, H.
    • International Journal of Automotive Technology
    • /
    • 제3권4호
    • /
    • pp.171-176
    • /
    • 2002
  • A bench test set-up is employed to simulate the friction characteristics of a paper-based friction material operating against a steel plate. Dry friction tests are run as well as tests with transmission fluids. Glazed friction material produces a negative coefficient of friction versus sliding velocity (f-v) curve for both dry friction and lubrication with transmission fluids. At low sliding speeds, the coefficient of friction when operating in transmission fluids for glazed friction materials is greater than that under dry friction. An appreciable negative f-v slope occurs at low sliding speeds for glazed friction materials when running with the transmission fluid. The friction material after running in produces a constant f-v curve under dry friction and a negative slope when lubricated with transmission fluid. At low sliding speeds, the coefficient of friction of the run-in friction material is lower than that of the glazed wet material. On the other hand, the run-in friction material has a larger friction coefficient than does the glazed friction material at higher sliding speeds.

원심송풍기 벌류트 내부유동의 수치해석적 연구 (Numerical Study on Flow Field in Centrifugal Fan Volute)

  • 김세진;주원구
    • 한국유체기계학회 논문집
    • /
    • 제1권1호
    • /
    • pp.64-71
    • /
    • 1998
  • The non-uniform pressure generated in the volute generally are propagating upstream. As a result, outlet conditions of rotaing impeller are changed and the performance degrades. The major object of this research is to develop the numerical method which can calculate the effects of impeller and volute flow field interactions. Under the assumption of steady three-dimensional incompressible turbulent flow, the time averaged N-S equations involving $k-{\epsilon}$ turbulent model was solved by the F.V.M. To verify the computational method, the calculations are compared with experimental results published in literature and show satisfactory agreement with them, The three-dimensional flow characteristics within the volute of a centrifugal fan at design and off-design operating points have also been studied.

  • PDF

압전작동기를 이용한 고주파수 젯팅 디스펜서의 성능 특성 (Performance Characteristics of High Frequency Jetting Dispenser Featuring Piezoactuator)

  • 윤보영;구오흥;홍승민;손정우;최승복
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 추계학술대회논문집
    • /
    • pp.595-600
    • /
    • 2007
  • This paper presents a new jetting dispenser driven by a piezoelectric actuator at high operating frequency to provide very small dispensing dot size of adhesive in modern semiconductor packaging processes. After describing the mechanism and operational principle of the dispenser, a mathematical model of the structured system is derived by considering behavior of each component such as piezostack and dispensing needle. In the fluid modeling, a lumped parameter method is applied to model the adhesive whose rheological property is expressed by Bingham model. The governing equations are then derived by integrating the structural model with the fluid model. Based on the proposed model, dispensing performances such as dispensing amount are investigated with respect to various input trajectories.

  • PDF

마이크로 가스터빈의 탈설계 운전 성능특성 (Performance Characteristics for Off-design Operation of Micro Gas Turbines)

  • 김동섭;황성훈
    • 한국유체기계학회 논문집
    • /
    • 제7권3호
    • /
    • pp.39-47
    • /
    • 2004
  • Micro gas turbines are designed with low turbine inlet temperature and pressure ratio. To overcome the efficiency defect of the simple cycle, adoption of the recuperator is an inevitable choice. In addition to the design performance, we should also pay attention to the off-design performance of gas turbines since they usually operate at part-load conditions lot a considerable amount of their lifetime. This study analyzes off-design performance characteristics of micro gas turbines and addresses the importance of the recuperation process doting the part load operation. Comparative analyses have been performed to evaluate the part load performance differences among various design and operating options : simple vs recuperative cycles, single vs two shaft configurations, various operating strategies for the single shaft configuration, and current vs advanced engines. Major finding is that maintaining high turbine exhaust temperature is crucial for efficient operation of micro gas turbines.

바이오 가스를 사용하는 가스터빈 열병합 시스템의 전부하 및 부분부하 운전특성 해석 (A Study on Full and Part Load Operations of a Biogas-fired Gas Turbine Combined Heat and Power System)

  • 강도원;이종준;김동섭;허광범
    • 한국유체기계학회 논문집
    • /
    • 제14권2호
    • /
    • pp.35-40
    • /
    • 2011
  • This study analyzed the influence of firing biogas on the performance and operation of a gas turbine combined heat and power (CHP) system. A reference CHP system designed with natural gas fuel was set up and off-design simulation was made to investigate the impact of firing biogas in the system. Changes in critical operating parameters such as compressor surge margin and turbine blade temperature caused by firing biogas were examined, and a couple of operating schemes to mitigate their changes were simulated. Part load operation of the biogas-fired system was compared with that of natural-gas fired system, and it was found that as long as the two system produce the same electric power output, they exhibit nearly the same heat recovery.

Numerical Prediction of Inlet Recirculation in Pumps

  • Lipej, Andrej;Mitrusevski, Dusko
    • International Journal of Fluid Machinery and Systems
    • /
    • 제9권3호
    • /
    • pp.277-286
    • /
    • 2016
  • The development of heavy-duty process pumps, usually based on various design criteria, depends on the pump's application. The most important criteria are Q-H, efficiency and NPSH characteristics. Cavitation due to inlet recirculation is not often one of the design criteria, although many problems in pump operation appear because of inlet recirculation, when the operation range is from 0.5-0.8 $Q_{opt}$. The present paper shows that steady state CFD analysis of inlet recirculation can give quite good results for the design of new hydraulic shapes, which have been developed to expand operating range and to minimize the harmful influence of recirculation at part load. In this paper, the structures of inlet recirculation are presented, as well as detailed shapes of vortices between the blades for various operating regimes, axial velocity distribution at the impeller inlet, the experimental results of NPSH and efficiency characteristics of an existing and newly designed pump.

케이싱 그루브가 장착된 천음속 축류압축기의 작동 안정성 향상을 위한 수치최적화 (Numerical Optimization of a Transonic Axial Compressor with Casing Grooves for Improvement of Operating Stability)

  • 김진혁;최광진;김광용
    • 한국유체기계학회 논문집
    • /
    • 제14권5호
    • /
    • pp.31-38
    • /
    • 2011
  • Optimization using a hybrid multi-objective evolutionary algorithm coupled with response surface approximation has been performed to improve the performance of a transonic axial compressor with circumferential casing grooves. In order to optimize the operating stability and peak adiabatic efficiency of the compressor with circumferential casing grooves, tip clearance, angle distribution at blade tip and the depth of the circumferential casing grooves are selected as design variables. Three-dimensional Reynolds-averaged Navier-Stokes equations with the shear stress transport turbulence model are discretized by finite volume approximations. The trade-off between two objectives with the interaction of blade and casing treatment is determined and discussed with respect to the representative clusters in the Pareto-optimal solutions compared to the axial compressor without the casing treatment.

유체기구를 이용한 유압계통의 충격치제어에 수탄되는 반응지연에 관한 연구 (A Study on the Associated Response Lag in Shock Control of Hydraulic System Using Fluid Device)

  • 이주성;이계복
    • 대한기계학회논문집B
    • /
    • 제26권11호
    • /
    • pp.1488-1495
    • /
    • 2002
  • The response time represents how fast a system responds to a given disturbance at the system boundary. Flow restricting devices for controlling transients can result in a decrease in the peakm pressure, but may change response time. Response lag in a hydraulic system leads to inefficient working cycle and operator discomfort. The experiments were conducted in order to get information on the parameters which exert appreciable influence on the response time. The experimental apparatu including a hydraulic actuator, orifice and a hydraulic pump was an idealization of a bucket hydraulic shifting system. Experimental results show that the response time depends on operating pressure and flow rate. The effects of orifice type and size on the response time are quantified.