Evaluation of the Aging Life of the Rubber Pad in Power Window Switch

  • Kang, Yong Kyu;Choi, Byung Ik;Woo, Chang Su;Kim, Wan Doo
    • Elastomers and Composites
    • /
    • v.54 no.4
    • /
    • pp.351-358
    • /
    • 2019
  • To evaluate the aging of a rubber pad in power window switch which is the part of a vehicle, the accelerated thermal aging test of rubber pad material is performed. Finite element analysis was performed using the nonlinear material constants of the rubber pad to calculate the operating force, and the Arrhenius relationship was derived from the aging temperature and time. The aging test was performed at 150, 180, 210, or 240 ℃ for 1 to 60 days. When the operating force of the rubber pad is changed by 10% from the initial value, the service life is expected to be 113 years, which is much longer than the life of the vehicle. This indicates that the aging life of the rubber pad is sufficiently safe and the operating force of the rubber pad during the life of the vehicle (20 years) was decreased by approximately 8.4%. By examining the correlation between the shear elastic modulus and operating force calculated from finite element analysis under each aging test condition, the changes in the operating force of the rubber pad and the shear elastic modulus showed good linear relationship. The aging life could be predicted by the change in shear elastic modulus and a process for predicting the aging life of automotive power window switch rubber pad parts is described herein.

Evaluation of Piping Failure Probability of Reactor Coolant System in Kori Unit 1 Considering Stress Corrosion Cracking (응력부식균열을 고려한 고리 1호기 원자로냉각재계통의 배관 파손확률 평가)

  • Park, Jeong Soon;Choi, Young Hwan;Park, Jae Hak
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.6 no.1
    • /
    • pp.43-49
    • /
    • 2010
  • The piping failure probability of the reactor coolant system in Kori unit 1 was evaluated considering stress corrosion cracking. The P-PIE program (Probabilistic Piping Integrity Evaluation Program) developed in this study was used in the analysis. The effect of some variables such as oxygen concentration during start up and steady state operation, and operating temperature, which are related with stress corrosion cracking, on the piping failure probabilities was investigated. The effects of leak detection capability, the size of big leak, piping loops, and reactor types on the piping failure probability were also investigated. The results show that (1) LOCA (loss of coolant accident) probability of Kori unit 1 is extremely low, (2) leak probability is sensitive to oxygen concentration during steady state operation and operating temperature, while not sensitive to the oxygen concentration during start up, and (3) the piping thickness and operating temperature play important roles in the leak probabilities of the cold leg in 4 reactor types having same inner diameter.

  • PDF

Models for Measurement of Efficiency of Free Flight Separation Assurance (자유비행 분리보증 효율성 측정모델 연구)

  • Lee, Dae-Yong;Young, Kang-Ja
    • Journal of Advanced Navigation Technology
    • /
    • v.15 no.6
    • /
    • pp.977-985
    • /
    • 2011
  • Airborne separation assurance is a key requirement for Free Flight Airspace operations, This paper study the feasibility of airborne separation assurance for free flight Airspaces operations by evaluating the efficiency measurement models. Three qualitatively different methods are utilized; one based Ground and Air conflict probability model, other based Dynamic Density model. the other based Direct operating cost model. The evaluation is Direct Operating Cost model and Two metrics are utilized for the efficiency measurements; airborne separation assurance performed quite well in the Free Flight evaluation; (1) 2 scenario of the conflict situations are resolved; (2) The MD-80 flight peformed separation assurance and efficiency, Not only appling for geometric method algorithm is more efficiently than potential method, but also the most efficiently geometric combined method.

An evaluation of local waters productivity by operating types (운영형태별 수도사업 생산성 평가)

  • Kim, Shang-Moon;Lee, Ik-Gyu
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.3
    • /
    • pp.325-334
    • /
    • 2011
  • Market Environment around water work industry is rapidly changing. ISO, International Organization for Standardization, announced the international water work service standard for comparison and evaluation between nations and businesses. And developed countries in water work are introducing market principle for growth of nation's water industry and reinforcement of its competitiveness. Also, some local governments entrusted their water utilities for improvement of competitiveness of water work. However, as some failure cases from overseas came out with emphasis, there are many refuting perspective about entrusted operation achievements of domestic water market. Hence, this paper evaluated competitiveness of domestic local water utilities from the perspective of productivity. After evaluating productivity using Malmquist productivity index, the authors compared and analyzed whether there is a difference of productivity between two different operating types by using Mann-Whitney test. As a result of analysis, it has shown that local water utilities achieved higher productivity at entrusted operation type rather than direct operation type. The local water utilities which chose entrusted operation had increased the productivity 13.9% on total factor productivity(TFP) during experimenting period, while the local water utilities which chose direct operation had increased 0.2%. The background of achieving this high productivity in entrusted operation was analyzed as a result of the higher technological effectiveness of a special water company. The result of this study can be referred when local government needs to decide on what operating types they will use.

Flow Field Design and Stack Performance Evaluation of the Thin Plate Separator for High Temperature Polymer Electrolyte Membrane Fuel Cell (고온 고분자전해질 연료전지 박판형 분리판의 유로 설계 및 스택 성능 평가)

  • KIM, JI-HONG;KIM, MINJIN;KIM, JINSOO
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.29 no.5
    • /
    • pp.442-449
    • /
    • 2018
  • Research on High temperature polymer electrolyte fuel cell (HT-PEMFC) has actively been conducted all over the world. Since the HT-PEMFC can be operated at a high temperature of $120-180^{\circ}C$ using phosphoric acid-doped polybenzimidazole (PBI) electrolyte membrane, it has considerable advantages over conventional PEMFC in terms of operating conditions and system efficiency. However, If the thermal distribution is not uniform in the stack unit, degradation due to local reaction and deterioration of lifetime are difficult to prevent. The thin plate separator reduces the volume of the fuel cell stack and improves heat transfer, consequently, enhancing the cooling effect. In this paper, a large area flow field of thin plate separator for HT-PEMFC is designed and sub-stack is fabricated. We have studied stack performance evaluation under various operating conditions and it has been verified that the proposed design can achieve acceptable stack performance at a wide operating range.

An Experimental Study on the Establishment of Optimum Operating Conditions in Sand Flux Apparatus for High-Quality Recycled Sand Manufacture (고품질 순환모래 제조를 위한 샌드플럭스 장치의 최적 운전조건 설정에 관한 실험적 연구)

  • Lee, Jong-suk;Lim, Hyun-Ung;Kim, Jae-Hwan;Lee, Do-Heun;Lee, Sang-Soo;Song, Ha-Young
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2007.11a
    • /
    • pp.23-26
    • /
    • 2007
  • In this study, recently it is urgently required that demolition waste concrete has to be recycled on the construction because urban development is accelerated and redevelopment project is rapidly expanded, production quantity of construction and demolition waste concrete is being increased. On the other hand, it has to be solved urgently the unbalance of demand and supply about the fine aggregate because the sea sand is restricted by exhaustion of river sand and intensification of environment influence evaluation. Therefore, the purpose of the study was to show the performance of the apparatus developed by the study and to propose the direction of the optimum operating conditions by having an experimental and positive evaluation about quality of recycled sand produced to develop a separating and selecting device of impurities for recycling of construction wastes which can have a bigger improvement of economical efficiency, productivity, environmental property and quality through a basic property of matter of recycled sand by each operating condition of sand flux in comparison with the existing production system of recycled sand.

  • PDF

Study on performance evaluation of a francis turbine (프란시스 수차의 성능평가에 관한 연구)

  • Ko, Jaemyoung;Kim, Youngjoon;Cho, Yong
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.207.1-207.1
    • /
    • 2011
  • The performance of a francis turbine is studied by applying a new performance evaluation tester. the performance of a francis turbine is predicted under several operating conditions and the prediction results are compared with model test data. As a result, it is demonstrated that the present method can predict the performance of a francis turbine with high accuracy and has usefullness as an engineering tool on the performance of hydraulic turbines.

  • PDF

Economic evaluation on heating systems of apartment complex (공동주택단지 난방시스템들에 대한 경제성 평가)

  • 조금남;윤승호;김원배
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.10 no.6
    • /
    • pp.773-783
    • /
    • 1998
  • The heating system for apartment complex may be classified as old systems including central system with steam boiler(S1), gas engine driven heat pump system(S2), system using waste heat(S3) and new systems including mechanical vapor re-compression system with flashing heat exchangers(S4), system using methanol(S5), system using metal hydride (S6). The purpose of the present study is to suggest optimal heating system by technically, economically and environmentally evaluating old and new heating systems of apartment complex from 500 to 3,000 households. Economic evaluation based on the technical evaluation results which estimated heat transfer area of heat exchangers and capacity of equipments was estimated initial investment cost, annual operating cost and relative payback period by considering annual increasing rates of energy cost and interest. Environmental evaluation provided annual generation rate of carbon dioxide. Initial investment cost was cheap in the order of S6, S5, S3, S2, S4, S1, annual operating cost was cheap in the order of S1, S2, S4, S5 and relative payback period was short in the order of S6, S5, S2, S3 and S4. Relative payback period was within 8 years for all scenarios of 3,000 households, and was increased as annual increasing rates of energy cost and interest were increased. As transportation pipe length was increased twice, payback period was increased by 1.4~2.6 time. The effect of temperatures of waste gas and waste water on the relative payback period was small within 0.8 years. The annual generation rate of carbon dioxide was big in the order of S4, S2 and S1. S4 was the most economic system among whole scenarios when S1 was replaced with other scenarios.

  • PDF

Lifetime Assessment for Oil-Paper Insulation using Thermal and Electrical Multiple Degradation

  • Kim, Jeongtae;Kim, Woobin;Park, Hung-Sok;Kang, Ji-Won
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.2
    • /
    • pp.840-845
    • /
    • 2017
  • In this paper, in order to investigate the lifetime of oil-paper insulation, specimens were artificially aged with thermal and electrical multiple stresses. Accelerated ageing factors and equivalent operating years for each aging temperatures were derived from results of tensile strengths for the aged paper specimens. Also, the evaluation for the multi-stress aged specimens were carried out through the measurement of impulse breakdown voltage at high temperature of $85^{\circ}C$. The lifetimes of the oil-paper insulations were calculated with the value of 66.7 for 1.0 mm thickness specimens and 69.7 for 1.25 mm thickness specimens throughout the analysis of impulse BD voltages using equivalent operating years, which means that dielectric strengths would not be severely decreased until the mechanical lifetime limit. Therefore, for the lifetime evaluation of the oil-paper insulation, thermal aging would be considered as a dominant factor whereas electrical degradation would be less effective.