• Title/Summary/Keyword: Opening height

Search Result 216, Processing Time 0.02 seconds

A radiographic study of temporomandibular joints in skeletal class III malocclusion (골격성 III급 부정교합자의 측두하악관절에 관한 방사선학적 연구)

  • Kim Sung-Eun;Kim Jae-Duk
    • Imaging Science in Dentistry
    • /
    • v.33 no.2
    • /
    • pp.85-90
    • /
    • 2003
  • Purpose : To investigate the differences between the position of the mandibular condyles in temporomandibular joints of patients presenting with normal occlusion and skeletal class III malocclusion. Materials and Methods: Forty-two subjects with normal occlusion and thirty-seven subjects exhibiting skeletal class III malocclusion prior to orthodontic treatment were included in the study. Transcranial radiographs of each subject were taken at centric occlusion and 1 inch mouth opening. The positional relationship between the mandibular condyles with articular fossae and articular eminences at two positional states were evaluated and analyzed statistically. Results: The mandibular condyles of the skeletal class III malocclusion group were found to be located more anteriorly from the center of the articular fossae compared to the normal occlusion group in centric occlusion. The mandibular condyles of the skeletal Class III malocclusion group were located more superiorly from the middle of articular height than those of the normal occlusion group in centric occlusion. However, these differences were not statistically significant. At 1 inch mouth opening, the mandibular condyles of the skeletal class III malocclusion group were placed more posteriorly from the articular eminences than those of the normal occlusion group. The mean angle of the articular eminence posterior slope were 56.51 ° ± 6.29° in the normal occlusion group and 60.37° ± 6.26° in the skeletal Class III malocclusion group. Conclusions: The mandibular condyles of the skeletal Class III malocclusion group were placed more anteriorly at centric occlusion and more posteriorly at 1 inch mouth opening when compared with those of the normal occlusion group.

  • PDF

Spray Pattern Analysis for a Centrifugal Fertilizer Distributor with Two Shutter Holes (두 개의 셔터 구멍이 적용된 원심식 비료 살포기의 살포패턴 분석)

  • Hwang, Seok-Joon;Park, Jeong-Hyeon;Lee, Ju-Yeon;Kim, Ki-Duck;Shin, Beom-Soo;Nam, Ju-Seok
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.18 no.10
    • /
    • pp.8-19
    • /
    • 2019
  • In this study, the spray pattern of a centrifugal fertilizer distributor with two shutter holes was analyzed and an effective driving width that satisfies proper spray uniformity was derived. The centrifugal fertilizer distributor was mounted on a tractor with a rated power of 23.7 kW and static and dynamic spray pattern tests were performed according to the standard procedure proposed by the American Society of Agricultural and Biological Engineers Standard ASAE S341.5. The height of the fertilizer distributor was 80 cm from the ground and the PTO (power take-off) shaft speed of the tractor was fixed at 540 rpm. The fertilizer scattered in space was collected using 275 evenly spaced collectors at shutter opening ratios of 25%, 50%, 75%, and 100%. The spray pattern was analyzed via the amount of sprayed fertilizer at each collector location and the coefficient of variation was used as an indicator of spray uniformity. Using the analyzed spray pattern, the effective driving width that satisfied less than 15% of the coefficient of variation was derived for different tractor driving patterns (race track mode, back and forth mode). From the results, spray uniformity increased as the shutter opening ratio decreased. The largest effective driving width was 8 m at a shutter opening ratio of 25% for both driving patterns.

A radiographical study on the changes in height of grafting materials after sinus lift: a comparison between two types of xenogenic materials

  • Hieu, Pham-Duong;Chung, Jin-Hyung;Yim, Sung-Bin;Hong, Ki-Seok
    • Journal of Periodontal and Implant Science
    • /
    • v.40 no.1
    • /
    • pp.25-32
    • /
    • 2010
  • Purpose: The performance of implant surgery in the posterior maxilla often poses a challenge due to insufficient available bone. Sinus floor elevation was developed to increase the needed vertical height to overcome this problem. However, grafting materials used for the sinus lift technique eventually show resorption. The present study radiographically compared and evaluated the changes in height of the grafting materials after carrying out maxillary sinus elevation with a window opening procedure. This study also evaluated the difference between two xenogenic bone materials when being used for the sinus lifting procedure. Methods: Twenty-one patients were recruited for this study and underwent a sinus lift procedure. All sites were treated with either bovine bone (Bio-$Oss^{(R)}$) with platelet-rich plasma (PRP) or bovine bone (OCS-$B^{(R)}$)/PRP. A total of 69 implants were placed equally 6-8 months after the sinus lift. All sites were clinically and radiographically evaluated right after the implant surgery, 7-12 months, 13-24 months, and 25-48 months after their prosthetic loading. Results: Changes of implant length/bone length with time showed a statistically significant decreasing tendency (P<0.05). There was no significant change in the Bio-$Oss^{(R)}$ group (P>0.05). In contrast, the OCS-$B^{(R)}$ group showed a significant decrease with time (P<0.05). However, no significant difference was observed between the two groups (P>0.05). Conclusions: The results showed that there was significant reduction in comparison with data right after placement, after 7 to 12 months, 13 to 24 months, and over 25 months; however, reduction rates between each period have shown to be without significance. No significant difference in height change was observed between the Bio-$Oss^{(R)}$ and the OCS-$B^{(R)}$ groups.

Model Test on the Opening Efficiency of the Midwater Pair Trawl Net (쌍끌이 중층망의 전개성능에 대한 모형실험)

  • 김정문;김진건
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.36 no.2
    • /
    • pp.73-88
    • /
    • 2000
  • A series of analysis and experiment on the fishing gear and method of the existing midwater pair trawl net with 12,800mm of maximum mesh size is carried out to determine the most effective shape factor. As the first step of this study, the fishing gear and method for the existing net are analyzed to solve problems, such as being low of the net height by increasing the towing speed, twist of net pendant and twine, suspension of float between knots of mesh. etc. Standing on these results, the existing net are modified by very effective shape based on the theory and technology designing the fishing gear. Also, the model experiment is carried out to determine the most effective shape factor of the modified net in the circulation water channel. The obtained results can be summarized as follows : 1. On the length of net pendants(No.2 and No.3) connected with side line, opening efficiency of net with length 8.0cm of net pendant is the greatest and in the order of 11.5cm, 15.0cm. 2. On the number of the net pendant, opening efficiency of net with 4 lines of net pendant is the greatest and in the order of 3 lines, 2 lines. Center part of side panel is pushed out backward, and the pushed length is increasing by increasing flow speed. 3. On the sinking force, opening efficiency of the net is increasing by increasing sinking force. And opening efficiency shows almost the same when sinking force is greater about 1.5 times than that of the existing net in case of the net with 3 lines of net pendant, and about 1.6 ~ 1.7 times than that of the existing net in case of the net with 2 lines.

  • PDF

Research of the Development of a Height-adjustable light-shelf based on an Open and Closed Concept - Focusing on the light-shelf Performance Evaluation Depending on the External Illumination- (개폐 개념의 높이 조절이 가능한 광선반 개발 연구 - 외부조도에 따른 광선반 성능평가 중심으로)

  • Kim, Surin;Lee, Heangwoo;Song, Seonkjae;Kim, Yongseong
    • KIEAE Journal
    • /
    • v.17 no.3
    • /
    • pp.83-90
    • /
    • 2017
  • Purpose: With the increase in the energy consumption in the building sector, many studies have recently been conducted to address this issue. Due to its efficiency, diverse studies on a light-shelf, which is a natural lighting system, are in progress. However, there has been no research on the external illumination that determines the performance of a light-shelf. Therefore, the present study aimed to prepare the external illumination standard for securing the lighting performance of a light-shelf through the light-shelf performance evaluation based on a 1:1 scale testbed, and to suggest a height-adjustable light-shelf based on an open and closed concept for the case in which the lighting performance of the light-shelf significantly deteriorates, by collecting the external illumination. Method: In this study, a 1:1 scale testbed was established for performance evaluation, and the external illumination standard for securing the performance of the light-shelf was prepared by comparing the lighting performance of the light-shelf depending on the open and closed condition of the light-shelf and the external illumination. Result: 1) In this study, a light-shelf that can be opened or closed depending on the external illumination was suggested. As a result, the prospect right can be secured by creating the condition where there is no light-shelf installation by moving the light-shelf to the top of the window when the lighting performance is not secured. 2) In the summer solstice, the external illuminations appropriate for lighting energy reduction were more than 75,000 lx and 60,000 lx for the light-shelf width of 0.3 m and 0.6 m, respectively. 3) In the intermediate period, the external illumination appropriate for lighting energy reduction was 60,000 lx. In the winter solstice, making the condition where there is no light-shelf installation by closing the light-shelf would be appropriate. 4) Based on the aforementioned results, the external illumination standard for the opening and closing of the height-adjustable light-shelf based on an open and closed concept suggested in this study was 60,000 lx, and the light-shelf with a width of 0.6 m would be advantageous for lighting energy reduction.

Experimental Study on the Fire Extinguishing Characteristics of Water Mist System (미분무수 소화설비의 소화특성 실험)

  • Hwang, Won-Jun;Kim, Hwang-Jin;Oh, Kyu-Hyung;Lee, Sung-Eun
    • Fire Science and Engineering
    • /
    • v.23 no.2
    • /
    • pp.78-84
    • /
    • 2009
  • We carried out fire extinguishing experiments with three kinds of water mist nozzle system. Fire extinguishing experiment according to installed nozzle height and fuel pan location was done. And fire extinguishing performance was compared with plain water and foam agent mixed solution. Water mist nozzle height was varied with 4m, 3.5m and 3m and position of fuel fan was varied 0.5m and 1m from the center of water mist nozzle. Foam agent that used in this experiment is 3% type of AFFF (Aqueous Film Forming Foam) solution. Experimental result showed the door opening effect was little. Fire extinguishing performance of foam agent mixture water mist was better than the plain water mist only.

The Observation of Fatigue Striations for Aluminum Alloy by Atomic Force Microscope(AFM) (원자력 현미경(AFM)에 의한 알루미늄 합금의 피로 스트라이에이션 관찰)

  • Choe, Seong-Jong;Gwon, Jae-Do
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.24 no.4 s.175
    • /
    • pp.955-962
    • /
    • 2000
  • Scanning Probe Microscope (SPM) such as Scanning Tunneling Microscope (STM) and Atomic Force Microscope (AFM) was shown to be the powerful tool for nano-scale characterization of a fracture surface . AFM was used to study cross sectional profiles and dimensions of fatigue striations in 2017-T351 aluminum alloy. Their widths (SW) and heights (SH) were measured from the cross sectional profiles of three-dimension AFM images. The following results that will be helpful to understand the fatigue crack growth mechanism were obtained. (1) Coincidence of the crack growth rate with the striation width was found down to the growth rate of 10-5 mm/cycle. (2) The relation of SH=0.085(SW)1.2 was obtained. (3) The ratio of the striation height to its width SH/SW did not depend on the stress intensity factor range K and the stress ratio R. (4) Not only the SW but also the SH changed linearly with the crack tip opening displacement (CTOD) when plotted in log-log scale. From these results, the applicability of the AFM to nano-fractography is discussed.

Numerical Evaluation of Hemming Defects Found on Automotive Door Panels (유한요소해석에 의한 자동차 도어패널의 헤밍 결함 평가)

  • Seo, O.S;Jeon, K.Y;Rhie, C.H;Kim, H.Y
    • Transactions of Materials Processing
    • /
    • v.24 no.4
    • /
    • pp.280-286
    • /
    • 2015
  • Hemming is used to connect two sheet metal components by folding the edge of an outer panel around an inner panel to create a smooth edge. The minimization of hemming defects is critical to the final quality of automobile products because hemming is one of the last operations during fabrication. Designing the hemmed part is not easy and is influenced by the geometry of the bent part. Therefore, the main problem for automotive parts is dimensional accuracy since formed products often deviate geometrically due to large springback. Few numerical approaches using 3-dimensional finite element model have been applied to hemming due to the small element size which is needed to properly capture the bending behavior of the sheet around small die corner and the comparatively big size of automotive opening parts, such as doors, hoods and deck lids. The current study concentrates on the 3-dimensional numerical simulation of hemming for an automotive door. The relationship between the design parameters of the hemming operation and the height difference defect is shown. Quality improvement of the automotive door can be increased through the study of model parameters.

Three-Dimensional Flow and Aerodynamic Loss Downstream of Turbine Rotor Blade with a Cutback Cavity Squealer Tip (터빈 동익 컷백스퀼러팁 하류에서의 3차원 유동 및 압력손실)

  • Kim, Seon-Ung;Lee, Sang-Woo
    • The KSFM Journal of Fluid Machinery
    • /
    • v.14 no.1
    • /
    • pp.48-54
    • /
    • 2011
  • The effect of channel cutback on three-dimensional flow fields and aerodynamic losses downstream of a cavity squealer tip has been investigated in a turbine rotor cascade for the squealer rim height-to-chord ratio and tip gap height-to-chord ratio of $h_{st}/c$ = 5.51% and h/c = 2.0% respectively. The cutback length-to-camber ratio is changed to be $CB/c_c$ = 0.0, 0.1, 0.2 and 0.3. The results show that longer cutback delivers not only stronger secondary flow but also higher aerodynamic loss in the tip leakage vortex region, meanwhile it leads to lower aerodynamic loss in the passage vortex region. The discharge of cavity fluid through the cutback opening provides a beneficial effect in the reduction of aerodynamic loss, whereas there also exists a side effect of aerodynamic loss increase due to local wider tip gap near the trailing edge. With increasing $CB/c_c$ from 0.0 to 0.3, the aerodynamic loss coefficient mass-averaged all over the measurement plane tends to increase slightly.

Remodeling Project of the 'Yeonsinae' Catholic Church (연신내 성당 리모델링 구축 프로젝트)

  • Bae, Kang-Hee;Lee, Hyok-Jun
    • Proceedings of the Korean Institute of Interior Design Conference
    • /
    • 2006.05a
    • /
    • pp.53-54
    • /
    • 2006
  • Recently with increasing interest in the operation of life cycle, building remodeling business is spreading like a fashion. Keeping pace with the trend, the present project carried out the remodeling of an existing neighborhood facility into a religious facility based on the concepts of remodeling, reform and renovation. Basic requirements were overcoming spatial limitations, solving structural problems, meeting various functional needs, and securing a spatial size, and the project designed the interior of the building according to these requirements suggested by the owner. To overcome the low floor height of the existing space, the main sanctuary on the 1st floor had the ceiling in the form of a slant and installed indirect lighting into the resulting gaps, maximizing the depth and width of the space visually. The subsidiary sanctuary on the first basement was finished with red bricks, forming an arch using the bricks, to create religious atmosphere. However, considering the low floor height as in the 1st floor and the ceiling even lowered by the arch structure, the arch was formed threefold and the radius of the curvature of the arch was enlarged to secure a spacious feeling. The outer appearance was finished with granite on existing structure to save the cost of construction. In addition to the use of the finishing material, the structure of the arch and the frame of the opening part and the finishing of the walls were expressed with uneven surface in order to avoid the plainness of the appearance.

  • PDF