• Title/Summary/Keyword: Opening efficiency

Search Result 328, Processing Time 0.035 seconds

The loss coefficient for fluctuating flow through a dominant opening in a building

  • Xu, Haiwei;Yu, Shice;Lou, Wenjuan
    • Wind and Structures
    • /
    • v.24 no.1
    • /
    • pp.79-93
    • /
    • 2017
  • Wind-induced fluctuating internal pressures in a building with a dominant opening can be described by a second-order non-linear differential equation. However, the accuracy and efficiency of the governing equation in predicting internal pressure fluctuations depend upon two ill-defined parameters: inertial coefficient $C_I$ and loss coefficient $C_L$, since $C_I$ determines the un-damped oscillation frequency of an air slug at the opening, while $C_L$ controls the decay ratio of the fluctuating internal pressure. This study particularly focused on the value of loss coefficient and its influence factors including: opening configuration and location, internal volumes, as well as wind speed and approaching flow turbulence. A simplified formula was presented to predict loss coefficient, therefore an approximate relationship between the standard deviation of internal and external pressures can be estimated using Vickery's approach. The study shows that the loss coefficient governs the peak response of the internal pressure spectrum which, in turn, will directly influence the standard deviation of the fluctuating internal pressure. The approaching flow characteristic and opening location have a remarkable effect on the parameter $C_L$.

A Model Experiment on the Basic Efficiency of Midwater Rope Trawl Net (로프 트롤 그물의 기본성능에 관한 모형실험)

  • Yae, Young-Hee;Lee, Byong-Gee
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.29 no.3
    • /
    • pp.200-213
    • /
    • 1993
  • A model experiment on a midwater rope trawl net which is used in the North Pacific to catch alaska pollack is carried out in the circulating tank to examine the basic efficiency of the net. The prototype is the net used by M/S Hanil(1, 179GT, 2, 700PS), a Korean trawler. The model net was made according to the Tauti's Similarity Law of Fishing Gear in 1/100 scale by considering the condition of the tank. To measure the basic efficiency of the standard model net, the vertical opening and width between some points marked on the net were measured, and the hydrodynamic resistance were determined. Then the constructive conditions of the net were varied as follows and the factors were measured again to compare the efficiency of those nets with that of the standard net(A-1 type) front weight multiplied 1.5 times: A-2 type. buoyancy and depressing force multiplied 1.7 times: A-3 type. front weight multiplied 1.5 times on A-3 type: A-4 type. depressors rigged at ground rope: B type. cod-end stuffed with cashmylon wad: C type. The results obtained can be summarized as follows: 1. The vertical opening at the center of head rope was steeply decreased with the flow velocity increasing and the vertical opening H(m) can be expressed in H=1.2v super(-1.2)(v : flow velocity in m/sec). The width of the net varied a little when the flow velocity was over 0.4m/sec, and the width of net mouth showed about 37% of the distance between the fore tips of net pendant. The shape of net mouth was almost a circle at 0.2m/sec and then steeply flatted elliptically with the flow velocity increasing and the area of mouth S(m super(2)) can be expressed in S=(1.65-2.3v)$\times$10 super(-2). The hydrodynamic resistance of the net increased almost linearly with the flow velocity increasing and the resistance R(kg) can be expressed in R=3.2$\times$d/l$\times$abv. where d/l denotes the mean of d(diameter of netting twine) and l(length of a leg in a mesh) from wing tip to the end of bag-net except cod-end on the side pannel, and a denotes the strectched circumference of the net at the fore end of a meshed part and b the stretched length of the whole net from wing tip to the end of cod-end. 2. In the condition-varied nets, the vertical opening of head rope showed some increase in every type net except the C type, and the increase showed the greatest in the B type by 30~54%, whereas it showed decrease in the C type by 5~10%. Variation of the area of net mouth showed almost the same tendency as the vertical opening and the increase showed the greatest in the B type by 20%, whereas it showed decrease in the C type by 12%. Hydrodynamic resistance showed some increase in every type compared with the standard net, and the rate of increase indicated 5~10% in the A-2, A-3 and A-4 type, 22% in the B type and 3% in the C type.

  • PDF

Temperature and Power Generation Characteristics of c-Si G/G Spandrel Window depending on Opening Ratio of PV Module (스팬드럴용 투광형 결정계 PV창호의 셀 간격 개구율에 따른 온도 및 발전성능 해석연구)

  • Yoon, Jong-Ho;Kim, Dong-Su;Oh, Myung-Hwan;Lee, Jae-Beom
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.4
    • /
    • pp.51-58
    • /
    • 2012
  • This study aims to analyze characteristics of Cell surface temperature and generated power performance for improving PV(Photovoltaic) system condition according to the cell opening ratio of transparent crystal PV system at Spandrel of curtain-wall. For this purpose, alternatives were classified for eight different cases that opening ratio of transparent crystal PV system varied from 0% to 70%, which was used by simulation tool, EnergyPlus. As results, it turned out that increasing opening ratio of transparent crystal PV system led higher PV surface temperature, back-sheet type was thus the most advantageous for decreasing surface temperature, annual generating efficiency, and annual accumulated generating power. Consequently, blocking off air space from outside insolation can advantageously keep to be better condition for generated power performance.

Development of Kaplan Type Turbine for Low Head Hydro Resources (저낙차 수자원활용을 위한 카프란수차 개발)

  • Lee, Chul-Hyung;Park, Wan-Soon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2007.05a
    • /
    • pp.1992-1996
    • /
    • 2007
  • The Kaplan turbine model has been tested and analized. The blade angle and the guide vane opening of the turbine model were designed to be varied according to the best combination of guide vane and runner blade opening. When the changes in head and output were comparatively large, the efficincy drop were small, so the efficiency characteristics and stability of the entire operating condition were maintained in good condition. These results showed that the developed model in this study will be suitable for small hydro power stations with large changes in head and load.

  • PDF

Experimental Study for Investigating the Optimum Operating Conditions of a Seawater Ice Machine (해수제빙장치의 최적 운전 조건 탐색을 위한 실험적 연구)

  • Li, H.;Joo, W.J.;Jeong, S.K.
    • Journal of Power System Engineering
    • /
    • v.14 no.5
    • /
    • pp.76-82
    • /
    • 2010
  • This paper investigates the optimum operating conditions to construct total automatic control system with high energy efficiency of a newly developed seawater ice machine. The machine has an electronic expansion valve(EEV) and a variable speed rotating drum with an evaporator installed inside. The coefficient of performance(COP) was used as an index to evaluate energy efficiency of the machine. At first, the opening angle of EEV was adjusted to obtain COP of the machine at a constant speed of the drum. Then, we checked seawater ice product versus opening angles of the EEV. Finally, effect of drum's rotating speed in response to product of seawater ice and seawater ice temperature were considered.

Performance Characteristics of Kaplan Turbine (카프란수차의 성능특성)

  • Lee, C.H.;Ju, Y.C.;Park, W.S.
    • Journal of the Korean Solar Energy Society
    • /
    • v.21 no.1
    • /
    • pp.27-31
    • /
    • 2001
  • The Kaplan turbine model has been tested and analized. The blade angle and the guide vane opening of the turbine model were designed to be varied according to the best combination of guide vane and runner blade opening. When the changes in head and output were comparatively large, the efficiency drop were small, so the efficiency characteristics and stability of the entire operating condition were maintained in good condition. These results showed that the developed model in this study will be suitable for small hydro power stations with large changes in head and load.

  • PDF

Responsive Pneumatic Facade with Adaptive Openings for Natural Ventilation (창호의 개폐조절을 기반으로 한 리스펀시브 뉴메틱 파사드)

  • Lee, Jisun;Lee, Hyunsoo
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.33 no.12
    • /
    • pp.29-39
    • /
    • 2017
  • The building skins are important architectural elements in both functional and aesthetical aspects. This study focuses on developing a responsive facade with autonomous opening and closing behaviors in accordance with environmental conditions and user requirements for natural ventilation for the office building. The pneumatic ETFE panels are applied as the skin materials taking advantage of the efficiency of the inflatable skin of lightness, architectural performance and sustainable material properties. The biomimetic design methodology is taken for its innovative and visionary concept for the facade design. The interpretation of the building facade in analogy to natural organisms delivers functional and aesthetic characters. By exploring the structural movements of the plant pores, the facade control is developed to be autonomous by the parameter values. The facade opening and closing configurations are derived through parametric modeling and visualization programming. Through the application of this study, expected results are to improve user comfort and energy efficiency.

An Experimental Study on Development of the Opening Apparatus for Oil Boom (오일펜스 전개장치 개발에 관한 실험적 연구)

  • Jang Duck-Jong;Na Sun-Chol
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.9 no.1
    • /
    • pp.45-54
    • /
    • 2006
  • The study was to review methods by which a ship can unfold and tow an oil boom by attaching the opening apparatus to an oil boom through experiments. The shape and dimension of the opening apparatus were designed with the measurement value of the towing tension load of the oil boom and the dimension of winch drum of the oil boom installed in the ship considered. For the field experiment to identify the performance of the opening apparatus, opening apparatuses were prepared to have the dimension of $3.0m^2$ and $6.0m^2$ which is 91% and 75% of the calculation value for type B and C respectively. As a result, T(kg), the value of tension in type B oil boom according to the towing speed(v) change when two ships are towed together were proved to be $T=920v^{1.1}\;and\;T=500v^{0.9}$ in case the distance is 100 m and 50 m. Based on the result, the dimension of the opening apparatus for type B and C oil boom was calculated as $3.3m^2$ and $8.0m^2$ respectively. When unfolding and towing by attaching the opening apparatus and 200 m of towing line at both ends of type B and type C oil boom, the maximum width of the opening apparatus was shown as 114 m and 95 m in average(width of opening/total length of oil boom: 33% and 57%) in the towing speed of 1.5 kt. It was evaluated that the opening apparatus could concentrate the spilled oil in a good performance. However as far as the increase rate of oil boom opening width according to the length of the towing line is debatable, the increase rate is remarkably reduced when it is lengthened from 100 m to 150 m and to 200 m although it showed extreme increase of 31% and 40% when the length of the towing line was changed from 50 m to 100 m. Therefore, it is inferred that the towing line should be maintained more or less 100 m to get good spread efficiency of the opening apparatus. Additionally, if the towing speed is faster than 1.5 kt, the opening width was narrowed because of the reduced spread efficiency and the shape of the oil boom can be unstable because of the partial sinking of the oil boom, run over waves, or flap of skirt. Thus the reasonable towing speed can be within 1.5 kt for the operation of the opening apparatus.

  • PDF

Development of a Probabilistic Joint Opening Model using the LTPP Data (LTPP Data를 이용한 확률론적 줄눈폭 예측 모델 개발)

  • Lee, Seung Woo;Chon, Sung Jae;Jeong, Jin Hoon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.4D
    • /
    • pp.593-600
    • /
    • 2006
  • Joint opening of jointed concrete pavement is caused by change in temperature and humidity of adjoined slab. The magnitude of joint opening influences on the load-transfer-efficiency and the behavior of sealant. If temperature or humidity decreases, joint opening increases. Generally maximum joint opening of a given joint is predicted by using AASHTO equation. While different magnitudes of joint opening at the individual joints have been observed in a given pavement section, AASHTO equation is limited to predict average joint opening in a given pavement section. Therefore the AASHTO equation may underestimate maximum joint for the half of joint in a given pavement section. Joints showing larger opening than the designed may experience early joint sealant failure, early faulting. Also unexpected spalling may be followed due to invasion of fine aggregate into the joints after sealant pop-off. In this study, the variation of the joint opening in a given pavement section was investigated based on the LTPP SMP data. Factors affecting on the variation are explored. Finally a probabilistic joint opening model is developed. This model can account for the reliability of the magnitude of joint opening so that the designer can select the ratio of underestimated joint opening.

Analysis on Electricity Consumption Characteristics of Apartments based on Architectural Planning Factors - foused on Households with a total area of 132~165㎡ in Seoul- (공동주택 건축계획요소에 따른 전기 에너지 소비특성 분석 - 서울지역의 40평형(132~165㎡)의 단위세대 전기에너지 사용량을 중심으로 -)

  • Park, So-Yun;Lee, Yun-Jae;Lee, Hyun-Soo
    • KIEAE Journal
    • /
    • v.11 no.5
    • /
    • pp.107-117
    • /
    • 2011
  • This paper aims to analyze architectural planning factors that could contribute to reductions in electricity consumption in the household of apartments, to apply energy saving methods at the design phase. These six architectural planning factors were orientation, building type (flat, tower block), standard floor access type (corridor access type, stair case type, EV hall access type), household location (floor), household opening type (one side opening, right angle opening, two sides opening or three sides opening), and bay on the facade (one bay, two bays, three bays, four bays), and these were derived from literature review. Household electricity consumption data were gathered from 2168 households with a total area of 135~150$m^2$ of 6 apartment complexes over 1000 households in Seoul. The annual characteristics of electricity consumption according to architectural planning factors were analyzed. And, variances between groups with respect to the mean of summer, winter, and annual electricity consumption according to each architectural planning factors were analyzed using ANOVA and t-test. The results showed that an annual electric energy saving of over 1000kWh was facilitated by these planning factors. In addition, high energy efficiency architectural planning factors based on the analysis were as follows: southwest orientation, flat type, corridor access type and staircase type, household loation below the 20th floor, two sides opening and three sides opening, and 2 bays and 3 bays.