• 제목/요약/키워드: Opening efficiency

검색결과 328건 처리시간 0.028초

The loss coefficient for fluctuating flow through a dominant opening in a building

  • Xu, Haiwei;Yu, Shice;Lou, Wenjuan
    • Wind and Structures
    • /
    • 제24권1호
    • /
    • pp.79-93
    • /
    • 2017
  • Wind-induced fluctuating internal pressures in a building with a dominant opening can be described by a second-order non-linear differential equation. However, the accuracy and efficiency of the governing equation in predicting internal pressure fluctuations depend upon two ill-defined parameters: inertial coefficient $C_I$ and loss coefficient $C_L$, since $C_I$ determines the un-damped oscillation frequency of an air slug at the opening, while $C_L$ controls the decay ratio of the fluctuating internal pressure. This study particularly focused on the value of loss coefficient and its influence factors including: opening configuration and location, internal volumes, as well as wind speed and approaching flow turbulence. A simplified formula was presented to predict loss coefficient, therefore an approximate relationship between the standard deviation of internal and external pressures can be estimated using Vickery's approach. The study shows that the loss coefficient governs the peak response of the internal pressure spectrum which, in turn, will directly influence the standard deviation of the fluctuating internal pressure. The approaching flow characteristic and opening location have a remarkable effect on the parameter $C_L$.

로프 트롤 그물의 기본성능에 관한 모형실험 (A Model Experiment on the Basic Efficiency of Midwater Rope Trawl Net)

  • 예영희;이병기
    • 수산해양기술연구
    • /
    • 제29권3호
    • /
    • pp.200-213
    • /
    • 1993
  • A model experiment on a midwater rope trawl net which is used in the North Pacific to catch alaska pollack is carried out in the circulating tank to examine the basic efficiency of the net. The prototype is the net used by M/S Hanil(1, 179GT, 2, 700PS), a Korean trawler. The model net was made according to the Tauti's Similarity Law of Fishing Gear in 1/100 scale by considering the condition of the tank. To measure the basic efficiency of the standard model net, the vertical opening and width between some points marked on the net were measured, and the hydrodynamic resistance were determined. Then the constructive conditions of the net were varied as follows and the factors were measured again to compare the efficiency of those nets with that of the standard net(A-1 type) front weight multiplied 1.5 times: A-2 type. buoyancy and depressing force multiplied 1.7 times: A-3 type. front weight multiplied 1.5 times on A-3 type: A-4 type. depressors rigged at ground rope: B type. cod-end stuffed with cashmylon wad: C type. The results obtained can be summarized as follows: 1. The vertical opening at the center of head rope was steeply decreased with the flow velocity increasing and the vertical opening H(m) can be expressed in H=1.2v super(-1.2)(v : flow velocity in m/sec). The width of the net varied a little when the flow velocity was over 0.4m/sec, and the width of net mouth showed about 37% of the distance between the fore tips of net pendant. The shape of net mouth was almost a circle at 0.2m/sec and then steeply flatted elliptically with the flow velocity increasing and the area of mouth S(m super(2)) can be expressed in S=(1.65-2.3v)$\times$10 super(-2). The hydrodynamic resistance of the net increased almost linearly with the flow velocity increasing and the resistance R(kg) can be expressed in R=3.2$\times$d/l$\times$abv. where d/l denotes the mean of d(diameter of netting twine) and l(length of a leg in a mesh) from wing tip to the end of bag-net except cod-end on the side pannel, and a denotes the strectched circumference of the net at the fore end of a meshed part and b the stretched length of the whole net from wing tip to the end of cod-end. 2. In the condition-varied nets, the vertical opening of head rope showed some increase in every type net except the C type, and the increase showed the greatest in the B type by 30~54%, whereas it showed decrease in the C type by 5~10%. Variation of the area of net mouth showed almost the same tendency as the vertical opening and the increase showed the greatest in the B type by 20%, whereas it showed decrease in the C type by 12%. Hydrodynamic resistance showed some increase in every type compared with the standard net, and the rate of increase indicated 5~10% in the A-2, A-3 and A-4 type, 22% in the B type and 3% in the C type.

  • PDF

스팬드럴용 투광형 결정계 PV창호의 셀 간격 개구율에 따른 온도 및 발전성능 해석연구 (Temperature and Power Generation Characteristics of c-Si G/G Spandrel Window depending on Opening Ratio of PV Module)

  • 윤종호;김동수;오명환;이재범
    • 한국태양에너지학회 논문집
    • /
    • 제32권4호
    • /
    • pp.51-58
    • /
    • 2012
  • This study aims to analyze characteristics of Cell surface temperature and generated power performance for improving PV(Photovoltaic) system condition according to the cell opening ratio of transparent crystal PV system at Spandrel of curtain-wall. For this purpose, alternatives were classified for eight different cases that opening ratio of transparent crystal PV system varied from 0% to 70%, which was used by simulation tool, EnergyPlus. As results, it turned out that increasing opening ratio of transparent crystal PV system led higher PV surface temperature, back-sheet type was thus the most advantageous for decreasing surface temperature, annual generating efficiency, and annual accumulated generating power. Consequently, blocking off air space from outside insolation can advantageously keep to be better condition for generated power performance.

저낙차 수자원활용을 위한 카프란수차 개발 (Development of Kaplan Type Turbine for Low Head Hydro Resources)

  • 이철형;박완순
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2007년도 학술발표회 논문집
    • /
    • pp.1992-1996
    • /
    • 2007
  • The Kaplan turbine model has been tested and analized. The blade angle and the guide vane opening of the turbine model were designed to be varied according to the best combination of guide vane and runner blade opening. When the changes in head and output were comparatively large, the efficincy drop were small, so the efficiency characteristics and stability of the entire operating condition were maintained in good condition. These results showed that the developed model in this study will be suitable for small hydro power stations with large changes in head and load.

  • PDF

해수제빙장치의 최적 운전 조건 탐색을 위한 실험적 연구 (Experimental Study for Investigating the Optimum Operating Conditions of a Seawater Ice Machine)

  • 이화;주우진;정석권
    • 동력기계공학회지
    • /
    • 제14권5호
    • /
    • pp.76-82
    • /
    • 2010
  • This paper investigates the optimum operating conditions to construct total automatic control system with high energy efficiency of a newly developed seawater ice machine. The machine has an electronic expansion valve(EEV) and a variable speed rotating drum with an evaporator installed inside. The coefficient of performance(COP) was used as an index to evaluate energy efficiency of the machine. At first, the opening angle of EEV was adjusted to obtain COP of the machine at a constant speed of the drum. Then, we checked seawater ice product versus opening angles of the EEV. Finally, effect of drum's rotating speed in response to product of seawater ice and seawater ice temperature were considered.

카프란수차의 성능특성 (Performance Characteristics of Kaplan Turbine)

  • 이철형;주영철;박완순
    • 한국태양에너지학회 논문집
    • /
    • 제21권1호
    • /
    • pp.27-31
    • /
    • 2001
  • The Kaplan turbine model has been tested and analized. The blade angle and the guide vane opening of the turbine model were designed to be varied according to the best combination of guide vane and runner blade opening. When the changes in head and output were comparatively large, the efficiency drop were small, so the efficiency characteristics and stability of the entire operating condition were maintained in good condition. These results showed that the developed model in this study will be suitable for small hydro power stations with large changes in head and load.

  • PDF

창호의 개폐조절을 기반으로 한 리스펀시브 뉴메틱 파사드 (Responsive Pneumatic Facade with Adaptive Openings for Natural Ventilation)

  • 이지선;이현수
    • 대한건축학회논문집:계획계
    • /
    • 제33권12호
    • /
    • pp.29-39
    • /
    • 2017
  • The building skins are important architectural elements in both functional and aesthetical aspects. This study focuses on developing a responsive facade with autonomous opening and closing behaviors in accordance with environmental conditions and user requirements for natural ventilation for the office building. The pneumatic ETFE panels are applied as the skin materials taking advantage of the efficiency of the inflatable skin of lightness, architectural performance and sustainable material properties. The biomimetic design methodology is taken for its innovative and visionary concept for the facade design. The interpretation of the building facade in analogy to natural organisms delivers functional and aesthetic characters. By exploring the structural movements of the plant pores, the facade control is developed to be autonomous by the parameter values. The facade opening and closing configurations are derived through parametric modeling and visualization programming. Through the application of this study, expected results are to improve user comfort and energy efficiency.

오일펜스 전개장치 개발에 관한 실험적 연구 (An Experimental Study on Development of the Opening Apparatus for Oil Boom)

  • 장덕종;나선철
    • 한국해양환경ㆍ에너지학회지
    • /
    • 제9권1호
    • /
    • pp.45-54
    • /
    • 2006
  • 오일펜스에 전개 장치를 부착하여 1척의 선박이 오일펜스를 예인전장할 수 있는 방안을 실험을 통해 검토한 것으로, 실험에 사용된 전개장치의 형태와 규모는 오일펜스에 마치는 예인 저항을 측정한 결과와 선박에 설치된 오일펜스 윈치 드럼의 크기를 고려하여 설계하였다. 전개장치의 성능 조사를 위한 현장 실험은 B형과 C형 오일펜스를 대상으로 계산 값의 약 91%와 75% 수준인 $3.0m^2$$6.0m^2$ 규모의 전개 장치를 제작하여 수행하였다. 그 결과,2척의 선박을 예인하였을 때, 예인 속도(v) 변화에 따른 B형 오일펜스의 장력 값, T(kg)는 양 선박간의 거리가 100m와 50m일 경우 $T=920v^{1.1},\;T=500v^{0.9}$로 나타났으며, 이를 근거로 계산된 B형 및 C형 오일펜스용 전개 장치 하나의 규모는 $3.3m^2$$8.0m^2$였다. B형 및 C형 오일펜스 양끝에 전개 장치와 예인줄 200m를 부착하여 예인전장하였을 때 오일펜스 개구부의 최고 폭은 예인 속도 1.5 kt에서 평균 약 114m와 95m(개구부 폭/오일펜스 전체 길이: 33%와 57%)를 나타내 전개장치가 유출유를 충분히 포집할 수 있는 전개 성능을 보인 것으로 평가되었다. 그러나 예인줄 길이 변화에 따른 오일펜스 개구부 폭의 증가율은 예인줄 길이가 50m에서 100m로 늘어났을 때 약 31%와 40% 정도로 크게 높아지지만, 예인줄이 100m에서 150m, 200m로 길어질수록 증가율이 크게 둔화되어 100m내외로 예인줄을 유지하는 것이 합리적이라고 판단된다. 또한 예인 속도가 1.5 kt 이상일 경우 모든 오일펜스에서 전개 성능이 저하되어 개구부 폭이 감소하였고, 오일펜스 일부분이 침강하거나 월파, 스커트 날림 현상 등 오일펜스의 전장 형상이 불안정해져 전개 장치 운용에 합리적인 예인 속도는 1.5 kt 이내로 볼 수 있다.

  • PDF

LTPP Data를 이용한 확률론적 줄눈폭 예측 모델 개발 (Development of a Probabilistic Joint Opening Model using the LTPP Data)

  • 이승우;전성재;정진훈
    • 대한토목학회논문집
    • /
    • 제26권4D호
    • /
    • pp.593-600
    • /
    • 2006
  • 줄눈 콘크리트포장의 줄눈폭의 크기는 인접한 슬래브의 온습도 변화에 따른 체적변형에 기인하여 발생하고 인접 슬래브 간 하중 전달율에 영향을 미치며 줄눈채움재의 설계를 위한 중요한 인자이다. 슬래브의 온도가 하강하거나 습도가 감소하면 줄눈폭은 증가며 일반적으로 최대 줄눈폭은 AASHTO Guide에서 제안된 식을 사용하여 예측하고 있다. 동일한 포장 구역 내에서도 각각의 줄눈별로 발생되는 줄눈폭의 크기가 상당한 차이를 보이고 있는 반면, AASHTO 줄눈폭 예측식은 동일 포장 구역 내에서는 각 줄눈들에서 동일한 줄눈폭이 발생한다는 가정을 갖고 개발되었다. 이러한 가정은 AASHTO 줄눈폭 예측식이 임의 포장구역 내에서의 줄눈폭의 평균값에 대한 예측만을 가능하게 하여 상당부분의 줄눈에 대해서는 과소평가를 초래한다는 단점을 갖게 한다. 이로인해 최대 줄눈폭이 과소평가된 줄눈에서는 줄눈채움재가 조기파손하고, 하중 전달율이 불량하여 단차가 발생할 소지가 높고, 수분의 하부침투 및 세골제등이 줄눈폭 사이에 침입하여 스폴링을 유발할 가능성이 높아진다. 이러한 파손들은 포장 설계시 고려되지 않기 때문에 계획된 포장 수명이 도달하기 전에 포장공용성이 저하되게 한다는 문제점이 있다. 본 연구에선 다양한 줄눈콘크리트포장의 줄눈폭 모니터링 데이터를 포함하고 있는 LTPP SMP Data를 이용하여 임의 포장 내에서의 최대 줄눈폭의 크기가 어떤 분포양상을 나타내는지 고찰하고 줄눈폭이 과소평가되는 비율을 포장설계자가 선택할 수 있도록 하는 확률론적 줄눈폭 예측 모델을 개발하였다.

공동주택 건축계획요소에 따른 전기 에너지 소비특성 분석 - 서울지역의 40평형(132~165㎡)의 단위세대 전기에너지 사용량을 중심으로 - (Analysis on Electricity Consumption Characteristics of Apartments based on Architectural Planning Factors - foused on Households with a total area of 132~165㎡ in Seoul-)

  • 박소윤;이윤재;이현수
    • KIEAE Journal
    • /
    • 제11권5호
    • /
    • pp.107-117
    • /
    • 2011
  • This paper aims to analyze architectural planning factors that could contribute to reductions in electricity consumption in the household of apartments, to apply energy saving methods at the design phase. These six architectural planning factors were orientation, building type (flat, tower block), standard floor access type (corridor access type, stair case type, EV hall access type), household location (floor), household opening type (one side opening, right angle opening, two sides opening or three sides opening), and bay on the facade (one bay, two bays, three bays, four bays), and these were derived from literature review. Household electricity consumption data were gathered from 2168 households with a total area of 135~150$m^2$ of 6 apartment complexes over 1000 households in Seoul. The annual characteristics of electricity consumption according to architectural planning factors were analyzed. And, variances between groups with respect to the mean of summer, winter, and annual electricity consumption according to each architectural planning factors were analyzed using ANOVA and t-test. The results showed that an annual electric energy saving of over 1000kWh was facilitated by these planning factors. In addition, high energy efficiency architectural planning factors based on the analysis were as follows: southwest orientation, flat type, corridor access type and staircase type, household loation below the 20th floor, two sides opening and three sides opening, and 2 bays and 3 bays.