• 제목/요약/키워드: Open-type

검색결과 2,733건 처리시간 0.033초

C형 경골천정 골절에 대한 일리자로브 외고정술 (ILIZAROV FIXATION FOR THE TYPE C TIBIAL PLAFOND FRACTURES)

  • 조헌오;곽경덕;조성도;김병용;오장호
    • 대한족부족관절학회지
    • /
    • 제1권1호
    • /
    • pp.51-58
    • /
    • 1997
  • The purpose of this study is to evalute the efficacy af the Ilizarov external fixation for the surgical treatment. of the tibial plafond fractures. We reviewed retrospectively fourteen cases of tibial plafond fractures with moderate to severe soft. tissue damage, which were fixed with Ilizarov external fixator. Using the AO Muler classification, there were four Type C1 fractures, six Type C2 and four Type C3. In most, of the cases, the ankles were operated on with other associated fractures within a few days after injury. We reduced the fracture indirectly by soft issue taxis and fixed externally across the ankle joint. using the circular external fixator with tensioned wires and ankle hinge. In cases of inadequate closed reduction, we applied limited open reduction and internal fixation. Range of motion exercise began immediately. Postoperative follow-up averaged fourteen months (ranges, 8-30 months). Overall clinical results rated good or excellent in 7 cases, fair in 4 and poor in 3. There were three cases of pin tract infection which were resolved with short-term antibiotics and local care; one delayed wound closure in a patient. whose fracture was associated with Type III open wound; one wound slough in a patient associated with Type II open wound, which was closed later by skin graft; and one osteoarthritis. From this review, we concluded that cross-ankle circular external fixation with tensioned wires with or without. limited open reduction is a reasonable alternative for the treatment of the tibial plafond fractures with severe soft tissue damage.

  • PDF

Wind-induced response of open type hyperbolic-parabolic membrane structures

  • Xu, Junhao;Zhang, Yingying;Zhang, Lanlan;Wu, Meng;Zhou, Yi;Lei, Ke;Zhang, Qilin
    • Structural Engineering and Mechanics
    • /
    • 제76권2호
    • /
    • pp.269-278
    • /
    • 2020
  • In this paper, the mechanical characteristics of the open type hyperbolic-parabolic membrane structure under wind load were investigated. First, the numerical simulation of a typical plane membrane structure was performed based on the Large-Eddy Simulation method. The accuracy of the simulation method was validated by the corresponding wind tunnel test results. Then, the wind load shape coefficients of open type hyperbolic-parabolic membrane structures are obtained from the series of numerical calculations and compared with the recommended values in the "Technical Specification for Membrane Structures (CECS 158: 2015). Finally, the influences of the wind directions and wind speeds on the mean wind pressure distribution of open type hyperbolic-parabolic membrane structures were investigated. This study aims to gain a better understanding of the wind-induced response for this type of structure and be useful to engineers and researchers.

공기조화용 버터플라이 밸브 하류에서의 3차원 유동특성 (Three-Dimensional Flow Characteristics in the Downstream Region of a Butterfly-Type Valve Used in Air-Conditioning Systems)

  • 박상원;이상우
    • 대한기계학회논문집B
    • /
    • 제24권2호
    • /
    • pp.260-269
    • /
    • 2000
  • Oil-film flow visualizations and three-dimensional flow measurements have been conducted in the downstream region of a butterfly-type valve used in air-conditioning systems, with the variation of a disk open angle. The flow visualizations in the flow symmetry plane show that there are a pair of counter-rotating separation/recirculation zones as wall as two jet-like near-wall flows. These flow disturbances are strongly depends on the disk open angle. Based on the flow visualization, a qualitative flow model is suggested in the near-field and downstream region of the valve disk. For a small disk open angle, the mean velocities and turbulent intensities have relatively small values in the near-field of the valve disk, but they do not show uniform distributions even in some downstream region. With an increment of the disk open angle, mean velocity variations and turbulent intensities are greatly increased in the immediate downstream region, but uniform distributions are quickly resumed as departing from the valve disk. The mass flow rate remains nearly constant for the disk open angles less than 30 degrees, meanwhile it strongly depends on the disk open angles between 45 and 75 degrees. The pressure loss is found to be about zero for the disk open angles less than 45 degrees, but is substantially increased for those larger than 75 degrees.

북촌 튼ㅁ자형한옥의 유형연구 (Typomorphological Study on Open-rectangular plan Hanok in the Traditional Urban Housing Neighborhood of Bukchon, Seoul)

  • 송인호
    • 건축역사연구
    • /
    • 제13권4호
    • /
    • pp.125-138
    • /
    • 2004
  • Open-rectangular plan Hanok is one of the major types that compose the urban tissues of Bukchon, a typical traditional residential area in Seoul. Through the comparison of the cadastral map of 1912 and the aerial photograph of 1962, the paper has given the outline of the and the distribution of Open-rectangular plan Hanok at Bukchon. And the paper defines the characteristics of Open-rectangular plan Hanok at Bukchon as followings. First, Open-rectangular plan Hanok at Bukchon is the mutated type of Open-rectangular plan Hanok in Kyong-gi Province. Second, the composition and characteristics of Bakat-chae and outer-courtyard have been changed through the adaptation itself to the compact lots of urban neighborhood. Third, the composition and characteristics of An-chae has not been changed except the inner corner bay, that gives the lights and view to An-bang through the window. And the comparison and observation of four examples, the paper defines the identities of Open-rectangular plan Hanok at Bukchon. The partial transformation comes from the conflicts and adjustments with the structure of alley and the topographical condition of lots.

  • PDF

성격의 선천적 요인(MBTI)과 후천적 요인(PAT)의 관계특성 연구 (A Study On The Relationship Characteristics Between Inborn(Myers-Brigg's Type Indicator: MBTI) and Acquired(Personality Adaptation Type: PAT) Factors of Personality)

  • 오수희
    • 한국사회복지학회:학술대회논문집
    • /
    • 한국사회복지학회 2004년도 춘계학술대회 자료집
    • /
    • pp.757-779
    • /
    • 2004
  • The purpose of study is to provide efficient initial approaches for counseling in social work practice settings. First, it attempts to identify the correlation between the Myers-Brigg's Type Indicator(MBTI), a personality index based on the theory of psychological typology, and Personality Adaptation Types(PAT) models. Second, it attempts to develop a counseling method which can be applied to the initial interview, using the paradigm of door to therapy such as "Open Door", "Target Door", and "Trap Door" based on the PAT theory. The result of the quantitative study showed the correlation between MBTI and PAT as follows: MBTI Extrovert and Feeling(E, F) type was statistically correlated to hysterical PAT. MBTI Extrovert, Intuition and Perceiving(E, N, P) type was statistically correlated to Obsessive-Compulsive PAT. In conclusion, this study finds that when a clinical social worker approaches a client with the client's MBTI personality type and an interventional personality adaptation theory approach such as "Open Door", "Target Door", or "Trap Door", the efficiency of communication is increased significantly.

  • PDF

유출지하수 열원 지열히트펌프시스템의 냉방성능 (Cooling Performance of Ground source Heat Pump using Effluent Ground Water)

  • 박근우;남현규;강병찬
    • 신재생에너지
    • /
    • 제3권4호
    • /
    • pp.47-53
    • /
    • 2007
  • Effluent ground water overflow in deep and broad ground space building. Temperature of effluent ground water is in $12{\sim}20^{\circ}C$ annually and the quality of that water is as good as living water. Therefore if the flow rate of effluent ground water is sufficient as source of heat pump, that is good heat source and heat sink of heat pump. Effluent ground water contain the thermal energy of surrounding ground. So this is a new application of ground source heat pump. In this study open type and close type heat pump system using effluent ground water was installed and tested for a church building with large and deep ground space. The effluent flow rate of this building is $800{\sim}1000ton/day$. The heat pump capacity is 5RT each. The heat pump cooling COP is $4.9{\sim}5.2$ for the open type and $4.9{\sim}5.7$ for close type system. The system cooling COP is $3.2{\sim}4.5$ for open type and $3.8{\sim}4.2$ for close type system. This performance is up to that of BHE type ground source heat pump.

  • PDF

유출지하수 열원 지열히트펌프시스템의 냉방성능 (Cooling Performance of Ground source Heat Pump using Effluent Ground Water)

  • 박근우;남현규;강병찬
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2007년도 추계학술대회 논문집
    • /
    • pp.471-476
    • /
    • 2007
  • Effluent ground water overflow in deep and broad ground space building. Temperature of effluent ground water is in $12{\sim}20^{\circ}C$ annually and the quality of that water is as good as living water. Therefore if the flow rate of effluent ground water is sufficient as source of heat pump, that is good heat source and heat sink of heat pump. Effuent ground water contain the thermal energy of surrounding ground. So this is a new application of ground source heat pump. In this study open type and c lose type heat pump system using effluent ground water was installed and tested for it church building with large and deep ground space. The effluent flow rate of this building is $800{\sim}1000$ ton/day. The heat pump capacity is 5RT each. The heat pump cooling COP is $4.9{\sim}5.2$ for the open type and $4.9{\sim}5.7$ for close type system. The system cooling COP is $3.2{\sim}4.5$ for open type and $3.8{\sim}4.2$for close type system. This performance is up to that of BHE type ground source heat pump.

  • PDF

유출지하수 열원 지열히트펌프시스템의 난방성능 (Heating Performance of Ground source Heat Pump using Effluent Ground Water)

  • 박근우;이응열
    • 신재생에너지
    • /
    • 제3권2호
    • /
    • pp.40-46
    • /
    • 2007
  • Effluent ground water overflow in deep and broad ground space building. Temperature of effluent ground water is in $12{\sim}20^{\circ}...$ annually and the quality of that water is as good as well water. Therefore if the flow rate of effluent ground water is sufficient as source of heat pump, that is good heat source and heat sink of heat pump. Effuent ground water contain the thermal energy of surrounding ground. So this is a new application of ground source heat pump. In this study open type and close type heat pump system using effluent ground water was installed and tested for a church building with large and deep ground space. The effluent flow rate of this building is $800{\sim}1000\;ton/day$. The heat pump capacity is 5RT. The heat pump heating COP was $3.85{\sim}4.68$ for the open type and $3.82{\sim}4.69$ for the close type system. The system heating COP including pump power is $3.0{\sim}3.32$ for the open type and $3.32{\sim}3.84$ for close type system. This performance is up to that of BHE type ground source heat pump.

  • PDF

Open-Short 방식의 임피던스 측정에 의한 분포정수의 보정 (A LOSSY LINE DISTRIBUTED PARAMETERS CALCULATION USING DATA OF OPEN-SHORT IMPEDANCE MEASURING METHOD)

  • ;조기연;변영복;서정일;김은수;김태진
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 F
    • /
    • pp.2553-2555
    • /
    • 1999
  • The paper contains design formulas and an execution algorithm for calculation of distributed parameters as well as wave and impedance parameters of a uniform transmission line using data of the line input impedance measurements by the OPEN-SHORT method. In difference from published before works on the OPEN-SHORT method application for line parameters determination, in which the lines with small losses are considered /1-3/, the obtained formulas allow to calculate parameters of transmission lines with arbitrary losses. It opens new possibilities of the OPEN-SHORT method utilization for development and application of the probe - type lossy dielectric media parameters meters based on transmission lines, including probe-type moisture material meters.

  • PDF

개방형 수치제어기를 이용한 수평암 타입 좌표측정기의 개발 (Development of the Horizontal Arm Type Coordinate Measuring Machine Using Open-Architecture Controller)

  • 김민석;정성종
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1997년도 추계학술대회 논문집
    • /
    • pp.184-187
    • /
    • 1997
  • Coordinate measuring machines(CMMs) are used to obtain the dimensional information with micron accuracy. This paper is concerned with the development of the horizontal arm type coordinate measuring machine using open architecture controller. The coordinate measuring machine considered in this paper consists of three orthogonal axes in the x, y and z directions. Open architecture controller IS used to implement a measuring system which can be fulfill to various needs of endusers of coordinate measuring machines. The open architecture controller presented here is embodied in personal computers. The programs and man-machine interfaces(MM1) are developed for various measuring conditions. Through the computer simulation based on the mathematical models of the coordinate measuring machine, control parameters are optimally tuned.

  • PDF