• Title/Summary/Keyword: Open loop response

Search Result 92, Processing Time 0.018 seconds

A study on characteristics of High Efficiency and Wideband Microstrip Band Pass Filter for Wireless Data Communication (무선데이터 통신을 위한 고효율 광대역 마이크로스트립 대역통과 필터 특성에 관한 연구)

  • Lee, Young-Hun;Song, Sung-Hae;Park, Won-Woo;Lee, Sang-Jae
    • Journal of IKEEE
    • /
    • v.12 no.4
    • /
    • pp.225-233
    • /
    • 2008
  • This paper presents a compact, low insertion loss, sharp rejection and wide band microstrip band pass filter that is composed rectangular loop resonator and step-impedance-open-stub(SIOS) for wireless data communication. The SIOS can be reduce length about 30% more than general 0.25${\lambda}$ stub. And stubs can have the advantage of tuning impedance magnitude. In order to demonstrate agrement of this paper prove, the optimized wide band pass filters are realized and experimented. A transmission line model used to calculate the frequency response of the new filters shows good agreement with measurements. The filter with perturbation stubs has four poles at rejection band, the poles are excited 3.610GHz, 4.265GHz at low frequency band, 8.494GHz, 9.056GHz at high frequency band. And the filter has 3dB fractional bandwidth of 57%(3.695GHz), an insertion loss of better than 0.37dB from 4.549GHz to 8.244GHz, and two rejection of greater than 30dB within 237MHz(4.312GHz${\sim}$ 4.549GHz) at low frequency band, 234MHz(8.244GHz-8.491GHz) at high frequency band.

  • PDF

A New PMU (parametric measurement unit) Design with Differential Difference Amplifier (차동 차이 증폭기를 이용한 새로운 파라메터 측정기 (PMU) 설계)

  • An, Kyung-Chan;Kang, Hee-Jin;Park, Chang-Bum;Lim, Shin-Il
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.21 no.1
    • /
    • pp.61-70
    • /
    • 2016
  • This paper describes a new PMU(parametric measurement unit) design technique for automatic test equipment(ATE). Only one DDA(differential difference amplifier) is used to force the test signals to DUT(device under test), while conventional design uses two or more amplifiers to force test signals. Since the proposed technique does not need extra amplifiers in feedback path, the proposed PMU inherently guarantees stable operation. Moreover, to measure the response signals from DUT, proposed technique also adopted only one DDA amplifier as an IA(instrument amplifier), while conventional IA uses 3 amplifiers and several resistors. The DDA adopted two rail-to-rail differential input stages to handle full-range differential signals. Gain enhancement technique is used in folded-cascode type DDA to get open loop gain of 100 dB. Proposed PMU design enables accurate and stable operation with smaller hardware and lower power consumption. This PMU is implemented with 0.18 um CMOS process and supply voltage is 1.8 V. Input ranges for each force mode are 0.25~1.55 V at voltage force and 0.9~0.935 V at current force mode.