• 제목/요약/키워드: Open cup tester

검색결과 47건 처리시간 0.021초

산류(Acids)의 인화점과 최소자연발화온도의 신뢰성 고찰 (Investigation of Reliability of Flash Points and Autoignition Temperatures of Acids)

  • 하동명
    • 한국안전학회지
    • /
    • 제24권2호
    • /
    • pp.42-47
    • /
    • 2009
  • The flash point and the AIT(auto-ignition temperature) are the most important combustible properties used to determine the potential for the fire and explosion hazards of flammable material. In order to know the accuracy of data in MSDS(Material Safety Data Sheet), the flash point of n-acids were measured by using Pensky-Martens closed cup tester(ASTM D93), Setaflash closed cup tester(ASTM D3278), Tag open cup tester(ASTM D1310) and Cleveland open cup tester(ASTM D92). Also, the AIT of n-acids were measured by using ASTM E659-78 tester. The measured the flash points and the AIT were compared with literatures and MSDS in KOSHA. The measured the flash points and the AIT were different from those in literatures and MSDS. Therefore, This paper shows that it is needed to investigate the MSDS compatibility of n-acids for the fire safety objectives.

노말트리데칸의 연소특성치의 적정성 고찰 (The Investigation of Compatibility of Combustible Characteristics for n-Tridecane)

  • 하동명
    • 한국안전학회지
    • /
    • 제27권3호
    • /
    • pp.83-88
    • /
    • 2012
  • For the safe handling of n-tridecane, the lower flash points and AITs(auto-ignition temperatures) by ignition delay time were experimented. Also lower explosion limits by the lower flash points were calculated. The lower flash points of n-tridecane by using closed-cup tester were experimented $92^{\circ}C$ and $96^{\circ}C$. The lower flash points and fire point of n-tridecane by using open cup tester were experimented 100 oC and 103 oC, respectively. This study measured relationship between the AITs and the ignition delay times by using ASTM E659 apparatus for n-tridecane. The experimental AIT of n-tridecane was 223 oC. The calculated lower explosion limit by using measured lower flash point 92 oC for n-tridecane was 0.6 Vol.%.

노말노난올의 연소특성치 측정에 의한 위험성 평가 (Risk Assessment by Means of Measurement of Combustible Characteristics for n-Nonanol)

  • 하동명
    • 한국화재소방학회논문지
    • /
    • 제26권2호
    • /
    • pp.84-89
    • /
    • 2012
  • 노말노난올의 안전한 취급을 위해, 폭발한계는 문헌을 통해 고찰하였고, 인화점과 발화지연시간에 의한 발화온도를 측정하였다. 그 결과, 노말노난올의 폭발하한계는 0.80 Vol.%, 상한계는 6.1 Vol.%를 추천하였고, 하부인화점은 밀폐계에서 $94{\sim}97^{\circ}C$와 개방식에서 $103{\sim}104^{\circ}C$로 측정되었다. ASTM E659-78 장치를 사용하여 자연발화온도와 발화지연시간을 측정하였고, 노말노난올의 최소자연발화온도는 $270^{\circ}C$로 측정되었다.

클리브랜드 개방식 장치를 이용한 이성분계 하부인화점 측정 및 계산 (The Measurement and Calculation of the Lower Flash Points using of Binary Systems Using Cleveland Open Cup Tester)

  • 이성진;하동명
    • 한국안전학회지
    • /
    • 제23권5호
    • /
    • pp.67-72
    • /
    • 2008
  • The lower flash points for the flammable binary systems, 2-propanol+formic acid and 2-propanol+n-butyric acid, were measured by Cleveland open cup tester. The optimization method using van Laar equation and the Raoult's law were used to estimate the lower flash points and were compared with experimentally-derived data. The calculated values based on the optimization method were found to be better than those based on the Raoult's law.

이소프로필 알코올의 화재 및 폭발 특성치의 측정 및 고찰 (The Measurement and Investigation of Fire and Explosion Characteristics of Isopropyl Alcohol)

  • 하동명
    • 한국가스학회지
    • /
    • 제16권3호
    • /
    • pp.8-15
    • /
    • 2012
  • 이소프로필 알코올의 안전한 취급을 위해 $25^{\circ}C$에서 폭발한계를 고찰하였고, 실험장치를 이용하여 하부인화점, 상부인화점, 연소점 그리고 발화지연시간에 의한 발화온도를 측정하였다. 그 결과, 공정의 안전을 위한 이소프로필 알코올의 폭발 하한계는 2.0 vol%이고, 상한계는 12.0 vol%로 문헌을 통해 판단되었다. 하부인화점은 밀폐계에서 $12{\sim}14^{\circ}C$와 개방식에서 $18{\sim}19^{\circ}C$이었고, 상부인화점은 $38^{\circ}C$로 측정되었다. ASTM E659 장치를 사용하여 측정된 최소자연발화온도는 $463^{\circ}C$이었다.

초산부틸의 화재 및 폭발 특성치 측정 및 예측 (Measurement and Prediction of Fire and Explosion Characteristics of n-Butylacetate)

  • 하동명
    • 한국안전학회지
    • /
    • 제32권5호
    • /
    • pp.25-31
    • /
    • 2017
  • The flash point, explosion limits, autoignition temperature(AIT) are important combustible properties which need special concern in the chemical safety process that handle hazardous substances. For the evaluation of the flammable properties of n-butylacetate, this study was investigated the explosion limits of n-butylacetate in the reference data. The flash points, fire points and AIT by the ignition delay time of n-butylacetate were experimented. The lower flash points of n-butylacetate by using the Setaflash and Pensky-Martens closed-cup testers were $24^{\circ}C$ and $26^{\circ}C$, respectively. The flash points of n-butylacetate using the Tag and Cleveland open cup testers are measured $31^{\circ}C$ and $40^{\circ}C$, respectively. And the fire points of n-butylacetate by the Tag and Cleveland open cup testers were measured $32^{\circ}C$ and $41^{\circ}C$. The AIT of n-butylacetate measured by the ASTM 659E tester was measured as $411^{\circ}C$. The lower explosion limit of lower flash point $24^{\circ}C$, which was measured by the Setaflash tester, was calculated to be 1.40 vol%. Also, the upper explosion limit of upper flash point $67^{\circ}C$ the Setaflash tester was calculated to be 12.5 vol%.

크실렌 이성질체의 인화점과 최소자연발화온도의 측정 (Measurement of Flash Points and Autoignition Temperatures for Xylene Isomers)

  • 하동명;이성진
    • 한국가스학회지
    • /
    • 제13권4호
    • /
    • pp.40-45
    • /
    • 2009
  • MSDS 자료의 적정성을 고찰하기 위해 크실렌 이성질체에 대해 Pensky-Martens 밀폐식(ASTM D93), Setaflash 밀폐식(ASTM D3278), Tag 개방식(ASTM D1310), Cleveland 개방식(ASTM D92) 장치 등을 이용하여 인화점을 측정하였으며, 또한 최소자연발화온도는 ASTM E659-78장치를 사용하여 측정하고, 문헌값들과 한국산업안전보건공단의 MSDS 자료와 비교하였다. 그 결과, 측정된 인화점과 최소자연발화온도는 이들과 차이를 나타내어 안전의 목적을 위해 연소특성치 고찰이 필요함을 알 수 있었다.

  • PDF

노말도데칸의 인화점과 최소발화온도 측정에 의한 연소위험성 고찰 (The Investigation of Combustible Hazard by Measurement of Flash Point and Autoignition Temperature of n-Dodecane)

  • 하동명
    • 한국화재소방학회논문지
    • /
    • 제25권2호
    • /
    • pp.120-125
    • /
    • 2011
  • 노말도데칸의 안전한 취급을 위해서 25에서 폭발한계를 고찰하였고, 하부인화점과 발화지연시간에 의한 발화온도를 측정하였다. 공정의 안전을 위해서 노말도데칸의 폭발하한계는 0.60Vol.%, 상한계는 4.7Vol.%를 추천하였고, 하부인화점은 밀폐계에서 $77^{\circ}C$$80^{\circ}C$와 개방식에서 $84{\sim}87^{\circ}C$로 측정되었다. ASTM E659-78 장치를 사용하여 자연발화온도와 발화지연시간을 측정하였고, 최소자연발화온도는 $222^{\circ}C$ 측정되었다.

클리브랜드 개방식 장치를 이용한 2성분계의 인화점 (Flash Points of the Binary Solutions Using Cleveland Open Cup Tester)

  • 하동명;이성진
    • 한국화재소방학회논문지
    • /
    • 제25권1호
    • /
    • pp.57-62
    • /
    • 2011
  • 인화점은 공정안전을 평가할 때 산업공정에서 가연성 액체의 중요한 연소 특성 가운데 하나이다. 본 연구에서는 클리브랜드 개방식 장치를 사용하여 n-propanol + formic acid계와 acetic acid + propionic acid계의 인화점을 측정하였다. 실험값은 Raoult의 법칙과 최적화 기법에 의해 추산된 값과 비교하였다. 그 결과, 최적화 기법에 의한 추산값이 Raoult의 법칙에 의한 추산값 보다 실험값에 더욱 근접하였다.

오토크레졸의 MSDS 연소특성치의 적정성 연구 (A Study on the Appropriateness of the Combustible Properties of MSDS for o-Cresol)

  • 하동명
    • 한국안전학회지
    • /
    • 제30권2호
    • /
    • pp.21-26
    • /
    • 2015
  • For the safe handling of o-cresol, this study was investigated the explosion limits of o-cresol in the reference data. The flash points and AITs(auto-ignition temperatures) by ignition delay time were experimented. The lower flash points of o-cresol by using closed-cup tester were experimented in $77^{\circ}C$ and $80^{\circ}C$. The lower flash points of o-cresol by using open cup tester were experimented in $86^{\circ}C$ and $87^{\circ}C$. This study measured relationship between the AITs and the ignition delay times by using ASTM E659 tester for o-cresol. The AIT of o-cresol was experimented as $495^{\circ}C$. The lower explosion limit(LEL) by the measured the lower flash point for o-cresol was calculated as 1.27 Vol%.