• Title/Summary/Keyword: Open column

Search Result 263, Processing Time 0.026 seconds

An Analytical Study for Unbonded Precast Column under Seismic Loading (비부착텐던 프리캐스트 교각의 내진거동에 대한 해석적 연구)

  • Choi, Seung-Won;Kim, Ik-Hyun;Cho, Jae-Yoel;Lee, Do-Keun
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.109-112
    • /
    • 2008
  • It has better seismic performance and construction performance in precast column than in conventional RC column. In this research, seismic performances of precast column are analyzed by OpenSEES. Main variables of analysis are concrete strength, jacking ratio of tendon, amount of tendon and size of segment. As the amount of tendon and jacking ratio are increased, the flexural strength is also increased. And there is very little effect as it varies concrete strength and size of segment. But high initial jacking ratio leads to early yielding of tendon. And it is considered that a size of segment is related on construction problem. And also, strain in core concrete is less than ultimate strain. Consequently, it is considered that the amount of transverse steel will be reduced.

  • PDF

Antioxidant and Antimicrobial Activities of Xanthium sibiricum (창이자의 항산화 활성 및 항균효과)

  • Shin, Sun-Woo;Lee, Jeong-Ho;Soo, Bang-Keuk
    • Korean Journal of Plant Resources
    • /
    • v.25 no.4
    • /
    • pp.372-378
    • /
    • 2012
  • Xanthium sibiricum using extracts antioxidant activity and antimicrobial activity were analyzed and the following results were obtained. Antioxidant activity using DPPH as a VLC column fractionation experiments XS-5 (water fraction of Xanthium sibiricum) concentration in the 500 ${\mu}g/ml$ to 87.53 percent in the highest antioxidant activity was found, VLC fractionation in XS-3-2 (eluted with chloroform/methanol 7~10%) concentration of 500 ${\mu}g/ml$, showed the antioxidant activity of 78.72%. The antioxidant activity measured by PCL XS-1 (n-hexane fraction of Xanthium sibiricum) XS-5 (water fraction of Xanthium sibiricum) and 13.32 nmol open column XS-3-2 (eluted with chloroform/methanol 7~10%) showed antioxidant activity with 14.34 nmol. The antimicrobial activity against Candida albicans XS-2 (methlene chloride fraction fo Xanthium sibiricum) is the concentration of 500 ${\mu}g$/disc 1 mm of the clean zone was formed. XS-3 (ethanol fraction fo Xanthium sibiricum) in the antioxidant activity using DPPH and PCL had higher antibacterial activity was low.

Rational and efficient approach to the preparation of the active fractions of Scutellaria baicalensis (황금(Scutellaria baicalensis) 유효분획물 제조의 합리적이고 효율적인 접근방법)

  • Kim, Doo-Young;Kim, Won Jun;Kim, Jung-Hee;Oh, Sei-Ryang;Ryu, Hyung Won
    • Journal of Applied Biological Chemistry
    • /
    • v.62 no.1
    • /
    • pp.31-38
    • /
    • 2019
  • Scutellaria baicalensis Georgi (Scutellariae Radix) has been widely used as a dietary ingredient and traditional herbal medicine such as diuretic, hyperlipidemia, antibacterial, anti-allergy, anti-inflammatory and anticancer properties. In this study, the isolation of biomarkers or bioactive compounds from complex S. baicalensis extracts represents an essential step for de novo identification and bioactivity assessment. The bioactive fraction consisted of eight compounds which was chromatographed on an analytical high performance liquid chromatography column using two different gradient runs. A simulative replacement of the analytical column with a medium pressure liquid chromatography and open column allowed the determination of gradient profile to allow sufficient separation in the preparative scale. From the optimized method, eight standard compounds have been identified in the fractions. In addition, MS, UV, HRMS detection was provided by ultraperformance liquid chromatographyequadrupole time-of-flight mass spectrometry (UPLC-QTof-MS) of all fractions. Therefore, this scale up procedure was successfully applied to a S. baicalensis extract.

An Experimental Study on Motions of two Pin-jointed Multi-floating Bodies (Pin-joint 연결된 다수 부유체의 운동에 대한 실험적 연구)

  • Lee, Seung-Chul;Bae, Sung-Yong;Goo, Ja-Sam
    • Journal of Power System Engineering
    • /
    • v.20 no.3
    • /
    • pp.5-10
    • /
    • 2016
  • The structure of the variable liquid column oscillator(VLCO) is analogous to that of the tuned liquid column damper used to suppress oscillatory motion in large structures like tall buildings and cargo ships. VLCO is using the technology which absorbs high potential energy made by process of accelerated motions effect of air spring by installation of inner air chamber. So, the application of VLCO can improve the efficiency of energy than that of wave energy converters made in Pelamis Company. In this research, experiments were performed for the models which have two different liquid column sizes. In order to find out the biggest motion response, two major conditions are taken into account. Two conditions are to open(or close) the valves and to differentiate the height of the liquid column.

Experimental capacity of perforated cold-formed steel open sections under compression and bending

  • Orlando, Maurizio;Lavacchini, Giovanni;Ortolani, Barbara;Spinelli, Paolo
    • Steel and Composite Structures
    • /
    • v.24 no.2
    • /
    • pp.201-211
    • /
    • 2017
  • This study evaluates the reliability of present European codes in predicting the collapse load of columns made with perforated cold-formed steel (CFS) profiles under combined axial load and bending. To this aim, a series of experimental tests on slender open-section specimens have been performed at varying load eccentricity. Preliminarily, stub column tests have also been performed to calculate the effective section properties of the investigated profile. By comparison of experimental data with code-specified M-N strength domains, the authors demonstrate that present code formulations may underestimate the collapse load of thin-walled perforated open sections. The study is the first step of a wider experimental and numerical study aimed at better describing strength domains of perforated CFS open sections.

Comparison of the elution patterns for polychlorinated dibenzo-p-dioxins/dibenzofurans (PCDDs/Fs) and dioxin-like polychlorinated biphenyls (PCBs) by manual open columns and automatic parallel LC columns (수동 및 자동화 액체 크로마토그래피 칼럼에 의한 PCDDs/Fs 및 다이옥신과 유사한 PCBs의 용출 패턴 비교)

  • Ahn, Yun Gyong;Shin, Jeoung Hwa;Yoo, Sun Young;Khim, Jeehyeong;Hong, Jongki
    • Analytical Science and Technology
    • /
    • v.18 no.1
    • /
    • pp.13-22
    • /
    • 2005
  • The elution patterns of seventeen 2,3,7,8-substituted PCDDs/Fs and 12 dioxin-like PCBs were studied by both manual open columns and automatic parallel LC columns in cleanup procedure. PCDDs/Fs and non-ortho-PCBs from other mono-ortho-PCBs were separated on automatic LC column, whereas they were not separated on an open manual column. The elution study on two cleanup methods was carried out using the PAR solution of unlabeled congeners and checked the recovery of each congener. Total recoveries of cleanup fractionation were ranged between 61.9 ~ 96.0% for PCDDs/Fs and 70.4 ~ 79.0% for PCBs by manual open columns and 71.8 ~ 104.5% for PCDDs/Fs and 61.3-120.3% for PCBs by automatic parallel LC columns, respectively. Unfortunately, #169-HxCB and 1,2,3,7,8-PeCDD were not separated on DB-5MS capillary column. The ions of 1,2,3,7,8-PeCDD were selected at M/M+2 instead of M+2/M+4 suggested by EPA method 1613. It is possible to discriminate 1,2,3,7,8-PeCDD and PCB #169 in HRGC/HRMS analysis.

Storage Lifetime Improvement of Zr-Ni K1 Delay System (Zr-Ni계 지연관 결합체(K1) 저장수명 향상)

  • Chang, Il-Ho;Back, Seung-Jun;Jung, Eun-Jin;Son, Young-Kap
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.13 no.2
    • /
    • pp.336-341
    • /
    • 2010
  • The burning interruption between the initiator and the delay column in a Zr-Ni K1 delay system used for a K510 fuze occurs with long-time storage. About 10 % failure probability of 15-years stored delay systems shows the failure mode in open literature. This paper shows storage lifetime improvement results for the delay system through changing the single-base delay column into double-base ones and controlling the manufacturing processes especially the initial inclusion of humidity. The double-base delay columns was implemented by inserting one delay column of fast burning rates between the initiator and the previous delay column of slow burning rates. Accelerated aging tests of the delay systems with double-base columns, and then the firing tests were performed to evaluate the improved lifetime. The double-base delay columns shows improved storage lifetime of the delay system through preventing the failure mode.

Research on axial bearing capacity of cold-formed thin-walled steel built-up column with 12-limb-section

  • Wentao Qiao;Yuhuan Wang;Ruifeng Li;Dong Wang;Haiying Zhang
    • Steel and Composite Structures
    • /
    • v.47 no.3
    • /
    • pp.437-450
    • /
    • 2023
  • A half open cross section built-up column, namely cold-formed thin-walled steel built-up column with 12-limbsection (CTSBC-12) is put forward. To deeply reveal the mechanical behaviors of CTSBC-12 under axial compression and put forward its calculation formula of axial bearing capacity, based on the previous axial compression experimental research, the finite element analysis (FEA) is conducted on 9 CTSBC-12 specimens, and then the variable parameter analysis is carried out. The results show the FEA is in good agreement with the experimental research, the ultimate bearing capacity error is within 10%. When the slenderness ratio is more than 96.54, the ultimate bearing capacity of CTSBC-12 decreases rapidly, and the failure mode changes from local buckling to global buckling. With the local buckling failure mode unchanged, the ultimate bearing capacity decreases gradually as the ratio of web height to thickness increases. Three methods are used for calculating the ultimate bearing capacity, the direct strength method of AISI S100-2007 gives result of ultimate axial load which is closest to the test and FEA results. But for simplicity and practicality, a simplified axial bearing capacity formula is proposed, which has better calculation accuracy with the slenderness ratio changing from 30 to 100.

Study of a self-centering beam-column joint with installed tapered steel plate links

  • Liusheng He;Yangchao Ru;Haifeng Bu;Ming Li
    • Structural Engineering and Mechanics
    • /
    • v.87 no.4
    • /
    • pp.391-403
    • /
    • 2023
  • In this study, a new type of self-centering beam-column joint with tapered steel plate links is proposed. Firstly, mechanical property of the basic joint (with the prestressed steel strands only, to provide the self-centering ability) and the combined joint (with both the prestressed steel strands and tapered steel plate links, to provide self-centering and energy dissipation simultaneously) is theoretically analyzed. Then, three joints with different dimensions and combinations of tapered plate links are designed and tested through a series of quasi-static cyclic loading tests. Test results show that a nearly bilinear elastic moment-rotation relationship for the basic joint is obtained. With the addition of tapered steel plate links, typical flag-shape hysteretic curves are obtained, which indicates good self-centering and energy dissipating ability of the combined joint. By installing multiple tapered plate links, stiffness and bearing capacity of the beam-column joint can be enhanced. The theoretical moment-rotation relationships agree well with the test results. A simplified macro model of the proposed joint is developed using OpenSees, which simulates reasonably well its hysteretic behavior.

Headspace Analysis for Residual Hexane in Vegetable Oil

  • Oh, Chang-Hwan;Kwon, Yong-Kwan;Jang, Young-Mi;Lee, Dal-Su;Park, Jong-Sei
    • Food Science and Biotechnology
    • /
    • v.14 no.4
    • /
    • pp.456-460
    • /
    • 2005
  • To enforce the maximum residue limit for residual hexane (0.005 g/kg) in commercially available Korean vegetable oil, convenient and accurate quantification methods were investigated. Using dual surrogate standards, pentane and heptane were dissolved in ethanol, and then added to hexane-tree sunflower oil for setting up the calibration curve. Gas Chromatograph-Flame Ionization Detector with a porous layer open tubular column, indicated good chromatographic separation of hexane from other inhibiting matrix components. The lowest calibration level was $0.5\;{\mu}g/g$, not exceeding a relative standard deviation of 10% (RSD%), and 1.0\;{\mu}g/g$ not exceeding a deviation of 22% RSD% using heptane as an internal standard for the Static headspace analysis by using a headspace auto-sampler and manual injection, respectively. The residual hexane was detected in nine of the samples among 87 vegetable oil samples purchased on the local market.