• Title/Summary/Keyword: Open Type System

Search Result 722, Processing Time 0.031 seconds

Heating Performance of Ground source Heat Pump using Effluent Ground Water (유출지하수 열원 지열히트펌프시스템의 난방성능)

  • Park, Geun-Woo;Lee, Eung-Youl
    • New & Renewable Energy
    • /
    • v.3 no.2 s.10
    • /
    • pp.40-46
    • /
    • 2007
  • Effluent ground water overflow in deep and broad ground space building. Temperature of effluent ground water is in $12{\sim}20^{\circ}...$ annually and the quality of that water is as good as well water. Therefore if the flow rate of effluent ground water is sufficient as source of heat pump, that is good heat source and heat sink of heat pump. Effuent ground water contain the thermal energy of surrounding ground. So this is a new application of ground source heat pump. In this study open type and close type heat pump system using effluent ground water was installed and tested for a church building with large and deep ground space. The effluent flow rate of this building is $800{\sim}1000\;ton/day$. The heat pump capacity is 5RT. The heat pump heating COP was $3.85{\sim}4.68$ for the open type and $3.82{\sim}4.69$ for the close type system. The system heating COP including pump power is $3.0{\sim}3.32$ for the open type and $3.32{\sim}3.84$ for close type system. This performance is up to that of BHE type ground source heat pump.

  • PDF

Operation Characteristics of Open Type Geothermal Heat Pump (개방형 지열 히트펌프 시스템의 운전 특성)

  • Lim, Hyo-Jae;Kong, Hyoung-Jin;Song, Yoon-Seok;Park, Seong-Koo
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.701-706
    • /
    • 2006
  • Groundwater heat pump systems are the oldest of the ground-souce systems and it has various type. Standing column well type are must be located in hard rock geology site and produce sufficient water for the conventional open loop system. These system are indirect type(the building circulating loop and ground water are intercept). Existence of the exchanger the foundation protect water quality to use of open loop. The design of open loop system are concern on the power requirements. An experimental study was analysis the extremely heating operation COP of ground water heat pump system. Operation efficiency of the 50RT systems shows that, COP $2.9{\sim}5.0$ in heating operation. And generally it shows 3.4.

  • PDF

액체로켓용 터빈시스템 설계

  • Choi, Chang-Ho;Kim, Jin-Han;Yang, Soo-Seok;Lee, Dae-Sung
    • Aerospace Engineering and Technology
    • /
    • v.1 no.1
    • /
    • pp.163-172
    • /
    • 2002
  • The turbine system composed of a nozzle and a rotor is used to drive turbopumps while gas passes through the nozzle, potential energy is converted to kinematic energy, which forces the rotor blades to spin. In this study, an aerodynamic design of a turbine system is investigated using compressible fluid dynamic theories with some pre-determined design requirements (i.e.,pressure ratio, rotational speed, required power etc.) obtained from a liquid rocket engine (L.R.E.) system design. For simplicity of a turbine system, impulse-type rotor blades for open type L.R.E. have been chosen. Usually, the open-type turbine system requires low mass flow rate compared to the close-type system. In this study, a partial admission nozzle is adopted to maximize the efficiency of the close-type turbine system. A design methodology of the a turbine system has been introduced. Especially, a partial admission nozzle has been designed by means of simple empirical correlations between efficiency and configuration of the nozzle. Finally, a turbine system design for a 10 ton thrust level of L.R.E is presented.

  • PDF

The Mold Close and Open Control of Injection Molding Machine Using Fuzzy Algorithm

  • Park, Jin-Hyun;Lee, Young-Kwan;Kim, Hun-Mo
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.575-579
    • /
    • 2005
  • In this paper, the development of an IMM(Injection Molding Machine) controller is discussed. Presently, the Mold Close and Open Control Method of a toggle-type IMM is open-loop control. Through the development, a PC based control system was built instead of an existing controller and a closed-loop control replaced the previous control method by using PC based PLC. To control the nonlinear system of toggle type clamping unit, a fuzzy PI control algorithm was selected and it was programmed by an IL(Instruction List) and a LD(Ladder Diagram) on a PC based PLC. The application of fuzzy algorithm as the control method was also considered to change a control object like a mold replacement or an additional apparatus. For the development of an IMM controller, PC based PLC of PCI card type, distributed I/O modules with CANopen and Industrial PC and HMI (Human Machine Interface) software were used.

  • PDF

Characteristics of Open-Loop Current Sensor with Temperature Compensation Circuit (온도보상회로를 부착한 개방형 전류측정기의 특성)

  • Ku, Myung-Hwan;Park, Ju-Gyeong;Cha, Guee-Soo;Kim, Dong-Hui;Choi, Jong-Sik
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.12
    • /
    • pp.8306-8313
    • /
    • 2015
  • Open-type current sensors have been commonly used for DC motor controller, AC variable controller and Uninterruptible Power Supply. Recently they have begun to be used more widely, as the growth of renewable energy and smart-grid in power system. Considering most of the open-type current sensors are imported, developing the core technology needed to produce open-type current sensors is required. This paper describes the development and test results of open-type current sensors. Design of C type magnetic core, selection and test of a Hall sensor, design of current source circuit and signal conditioning circuit are described. 100A class DIP(Dual In-line Package) type and SMD(Surface Mount Devide) type open-type current sensors was made and tested. Test results show that the developed open-type current sensor satisfies the accuracy requirement of 2% and linearity requirement of 2% at 100 A of DC and AC current of 60Hz. Temperature compensation was carried out by using a temperature compensation circuit with NTC(Negative Temperature Coefficient) thermistor and the effect of the temperature compensation are described.

Experimental study on reduction in rain water penetration through industrial windows used for natural ventilation (자연환기용 공장창호의 빗물유입 저감대책에 관한 실험적 연구)

  • Piao, Cheng Xu;Kim, Tae-Hyeung;Ha, Hyun-Chul;Xu, Rong Bin
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.20 no.3
    • /
    • pp.175-183
    • /
    • 2010
  • Windows are widely used for natural ventilation of the various buildings. Especially high level windows as a part of industrial ventilation systems, play a crucial role in natural ventilation. Compared to mechanical ventilation system, natural ventilation has the advantage of lower installation and operating costs. In general, high level windows for industrial buildings have three types; louver type, 45$^{\circ}$ open type and 90$^{\circ}$ open type. Based on previous studies, it was found that the louver type and 45$^{\circ}$ open type are very effective in reducing rainwater penetration, but they did not have enough ventilation efficiencies. Preliminary tests were performed with the various types of windows. It was found that a 90$^{\circ}$ open double layer type window was the best among those which tested in our preliminary tests. Simulated rain was used to estimate the amount of rain penetrated through windows and to observe the paths of rain penetration. Various 90$^{\circ}$ open windows were tested to find the windows with minimum rain penetration and maximum ventilation efficiency.

Design Classification and Development of Pattern Searching Algorithm Based on Pattern Design Elements - With focus on Automatic Pattern Design System for Baseball Uniforms Manufactured under Custom-MTM System - (패턴설계요소기반의 디자인 분류 및 패턴탐색 알고리즘개발 - 맞춤양산형 야구복 자동패턴 설계시스템을 위한 -)

  • Kang, In-Ae;Choi, Kueng-Mi;Jun, Jung-Ill
    • Fashion & Textile Research Journal
    • /
    • v.13 no.5
    • /
    • pp.734-742
    • /
    • 2011
  • This study has been undertaken as a basic research for automatic pattern design for baseball uniforms manufactured under custom-MTM system, propose building up of a system whereby various partial patterns are combined under an automatic design system and develop a multi-combination type pattern searching algorithm which allows development of a various designs. As a result of this, type classification based on pattern design elements includes side, open, collar, facing and panel type. Design have been divided into coarse classification ranging from level 1 to 7 according to pattern design elements, based on a design distribution chart. Out of 7 such levels, 3 major types determining design which are, more specifically, level 1 sleeve type, level 2 open type and level 3 collar type, have been taken and combined to determine a total of 12 types to be used for design classification codes. Respective name of style and patterns have been coded using alphabet and numerals. Totally, pattern searching algorithm of multi-combination type has been developed whereby combination of patterns belonging to a specific style can be retrieved automatically once that style name is designated on the automatic pattern design system.

A Study on the Layout Patterns of Public Schools in Manhattan - Focused on Relationship between Manhattan Grid Plan and Open Space - (뉴욕시 공립학교에 나타난 배치 특성에 관한 연구 - 맨하튼 가로체계와 외부공간의 관계를 중심으로 -)

  • Kim, Pil-Soo;Jeon, You-Chang
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.20 no.2
    • /
    • pp.3-14
    • /
    • 2013
  • The purpose of this study is to analyze patterns of public school building layout types, open space and relationship with communities in the Manhattan grid plan. The study illustrates how building layout patterns of school facilities are influenced by societal demands in the urban grid environment. During the nineteenth century, the Island of Manhattan was transformed into a physical representation of the Cartesian coordinate system via the development of the grid street plan. In order to take advantage of streets as urban space, it is quite important to understand characteristics of communities and open space relationships between buildings and streets. Moreover, the strategic planning of schools' outdoor space vitalizes public streets as a critical community anchor. This research reviews 118 Manhattan public schools and categorizes them by (1) building layout type, (2) site type, (3) circulation and public open space, which are the biggest factors that determine the layout patterns of the public schools in Manhattan. As a result of analysis, the layout patterns are classified into seven types : "ㅡ", "L", "ㄷ", "ㅁ", "H", "T" and "other" type. Of these, "ㅡ" type and "L" type occur most frequently, because these configurations most flexibly fit into the limited grid-locked blocks, the various types of site & topography, and adapt most dynamically to the open spaces created by using avenues and streets. The ultimate objective of this study is to provide a case study for future efforts to plan open spaces for campuses that effectively utilize the streets in proximity.

A Study on Detection Algorithm of Open Phase Fault in Grid-Connected Transformer for PV System (태양광전원 연계용변압기의 결상사고 검출 알고리즘에 관한 연구)

  • Kang, Kab-Seok;Tae, Dong-Hyun;Lee, Hu-Dong;Rho, Dae-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.5
    • /
    • pp.22-33
    • /
    • 2021
  • In the case of open phase faults caused by the disconnection of distribution feeders interconnected to a PV system, many problems can occur depending on the core type and wiring method of the grid-connected transformers. Moreover, open phase faults are difficult to detect because the open phase voltage of the existing protection relay (Open Phase Relay (47)) can be maintained, even though a disconnection fault occurred, depending on the wiring method and the iron core type of the grid-connected transformer for a PV system. Therefore, this paper proposes a novel algorithm to detect open phase faults by comparing the currents and phases between the primary and secondary sides of a grid-connected transformer. In addition, this paper presents the modeling of a distribution system and protection devices for detecting open phase faults using PSCAD/EMTDC S/W, and implements a test protection device for detecting open phase faults based on the above-mentioned modeling. The simulation and test results confirmed that the proposed algorithm is useful for detecting open phase faults according to the wiring method and iron core type of grid-connected transformer for a PV system because operation slope and unbalance rate of the primary current exceed the setting value (30[%]) of the protection device.

An Analysis on the Status of Parks and Open Space Development by Housing Development Plans

  • Lim Won-Hyeon;Kim Yong-Soo
    • Journal of the Korean Institute of Landscape Architecture International Edition
    • /
    • no.2
    • /
    • pp.14-24
    • /
    • 2004
  • This study focused on 15 parks to investigate the actual developmental conditions for preservation type parks and artificial type parks in the 9 residential land development sites managed by the Korea Land Corporation in Daegu and Gyeongsangbukdo area from 1994 to 2002. Emphasis is placed upon the types of land use, park arrangements, park facilities, types of planted trees and landscaping expense, with a view to discovering ways of improving the efficiency of future park development.

  • PDF