• 제목/요약/키워드: Open Building

검색결과 1,045건 처리시간 0.04초

통일신라시대 주택의 평면유형 분석 - 경주 신라왕경 발굴유구를 중심으로 - (A Study on the Plane Type of House in Unified Silla Period - Focused on the Capital Remains of Silla in Gyeongju -)

  • 이정미
    • 한국주거학회논문집
    • /
    • 제26권6호
    • /
    • pp.139-146
    • /
    • 2015
  • In this study, the plane type of main building relics of unified Silla period house site which excavated in Gyeongju city after 1990s was classified and the architectural characteristic of them was investigated. The chronology of building relics in Silla capital city site was mostly known as 8-9th century, and by standard of column arrangement, the plane types of them could be classified as grid type, front veranda-grid type, outer column type. The outstanding characteristic of plane is wide span and open front veranda. In most relics the span were over 4 meters, and inner foundations for small post and strip foundation were found between columns. The front veranda added type buildings were composited of enclosed main room and open front veranda, and column arrangement of them dose not fall into line in most case. Thus it thought that the structures of enclosed main room and open front veranda were independent. The interior space of enclosed main room were divided two rooms by partition wall in some case. In this case, one room is enclosed by wall, and the other room has open front side. This plane is considered for the pleasant life in cold winter and hot summer.

패시브환기외피의 통기 및 열성능에 관한 실험적 연구 (An Experimental Study on Ventilation and Thermal Performance of Passive Ventilation Building Envelopes)

  • 윤성환;이태철;강정식
    • 설비공학논문집
    • /
    • 제23권11호
    • /
    • pp.711-717
    • /
    • 2011
  • In this study, 5 types of PVS(Passive ventilation system) units are made and experimented its ventilation performance, thermal performance according to open rate and hole diameter of perforated aluminum plane. Results are as follows. 1) The ventilation performance increases approximately 50~70% according by the open rate of PVS increasing. Also, the ventilation performance increases about 2%~12% according by the hole diameter of PVS increasing. 2) In winter temperature/pressure condition(in : $20^{\circ}C$, out : $-2^{\circ}C/{\Delta}P$ : 0.2~5.0Pa) the temperature of inflow air decreases according by the open rate of PVS increasing. Heat gain performance decreases 10.1%, 25.6% when open rate increases 3) In the same condition, Heat gain performance decreases 18.3%, 18.8% according by the hole diameter of PVS increasing.

딥러닝 기반 BIM(Building Information Modeling) 벽체 하위 유형 자동 분류 통한 정합성 검증에 관한 연구 (Using Deep Learning for automated classification of wall subtypes for semantic integrity checking of Building Information Models)

  • 정래규;구본상;유영수
    • 한국BIM학회 논문집
    • /
    • 제9권4호
    • /
    • pp.31-40
    • /
    • 2019
  • With Building Information Modeling(BIM) becoming the de facto standard for data sharing in the AEC industry, additional needs have increased to ensure the data integrity of BIM models themselves. Although the Industry Foundation Classes provide an open and neutral data format, its generalized schema leaves it open to data loss and misclassifications This research applied deep learning to automatically classify BIM elements and thus check the integrity of BIM-to-IFC mappings. Multi-view CNN(MVCC) and PointNet, which are two deep learning models customized to learn and classify in 3 dimensional non-euclidean spaces, were used. The analysis was restricted to classifying subtypes of architectural walls. MVCNN resulted in the highest performance, with ACC and F1 score of 0.95 and 0.94. MVCNN unitizes images from multiple perspectives of an element, and was thus able to learn the nuanced differences of wall subtypes. PointNet, on the other hand, lost many of the detailed features as it uses a sample of the point clouds and perceived only the 'skeleton' of the given walls.

실내공적공간의 공공성에 관한 연구 (A Study on Public Needs for Privately Owned Public Space)

  • 윤지혜;김정곤
    • 한국실내디자인학회논문집
    • /
    • 제15권5호
    • /
    • pp.157-166
    • /
    • 2006
  • Recently, it appears several counterproposals about desirable figures of urban architecture. All of them proposes 'publicity' with cohernt tendency. The reason why it concentrates quantitative expansion of city without united design by urban plannar is that neglect quality values of city. As a solution of poor environment, there cue out the various efforts, about problem of each building, problem of city space, problem of laws and so forth. The reason why necessity of public space was embossed in that architecture extend the activity of citizen and make up the city space. But, each building pursues the private interest, so it is difficult to secure a public space with a high hand. Thus, architecture law has been revised in 1991 and bring the system of open space to match up the publicity and the private interest. Actually, western country brought it and obtained excellent results. While quantity of open space have increased since 1991, a lot of problems revealed in real usage and quality. By means of problem's solution, this study focus on the diversion of recognition for necessity of various open space. In result, on the occasion of approach and openess, except for several building, most glass a facade and the pedestrian can approach easily. Moreover, office buildings near the subway station connected with their low floor. So, the office buildings give openess to pedestrian and a people can approach easily to the buildings. On the occasion of amenity, most have bank and lobby on the first floor and have facilities on the underground floor. It leave open. But the reason why they have bank and lobby is that the space is dry and boring(without elements of nature and rest space). Hence, to make a space full of vitality, it have to plan various design elements and facilities. First of all, plan of indoor public space have to make up facility for the public interest. This study is basic investigation for necessity of indoor public space and through the survey of office buildings, it analyze the character of plan and find out the method of publicity's realization.

오픈마켓에서 신뢰가치성이 구매의도에 미치는 영향: 신뢰와 불신을 중심으로 (The Effect of Trustworthiness on Purchase Intention in Open Markets: Focusing on Trust and Distrust)

  • 최슬비;안현철;곽기영
    • 한국정보시스템학회지:정보시스템연구
    • /
    • 제26권1호
    • /
    • pp.171-188
    • /
    • 2017
  • Purpose This study investigates the effects of trust and distrust on intention to purchase in open market, based on the idea that trust and distrust can co-exist. Specifically, this study approached the effects of trust and distrust of the open market on the intention to purchase from a two-dimensional perspective, and examined trustworthiness as the antecedents of trust and distrust. Design/Methodology/Approach In this study, we conducted a questionnaire survey on consumers who have actually purchased a product from open markets in Korea for two months. As a result, 141 users are chosen for the sample. We apply PLS (Partial Least Squares) structural equation modeling (SEM) to verify our theoretical model using the software application SmartPLS 3.0. Findings First, trust in open market positively affects intention to purchase, whereas distrust in open market negatively affects intention to purchase. Second, the three antecedents of trust (i.e. three factors constituting trustworthiness such as ability, benevolence and integrity) affect trust in open market. Third, integrity negatively affects distrust in open market. Since integrity plays an important role in building both trust and distrust in open market, the operators of open market should pay attention to managing their integrity.

PIV 풍동실험을 통한 공장건물의 자연환기 향상 연구 (Improvement of Natural Ventilation in a Factory Building Using PIV Technique)

  • 강종훈;이상준
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2005년도 추계학술대회 논문집
    • /
    • pp.46-49
    • /
    • 2005
  • Vents at outer walls of a large factory building are very important for natural ventilation. But, if a full-open vent is used, rain comes through the vents. We tried to utilize the natural ventilation effectively using a louver. A 1/120 scale-down building model was placed inside an atmospheric boundary layer simulated in a wind tunnel test section. The effect of louver angle on the ventilation flow inside the factory building was investigated experimentally. Instantaneous velocity fields inside the building model were measured using a 2-frame PIV system with varying the louver angles ($\theta=20^{\circ},\;40^{\circ},\;60^{\circ}$). For the case of $\theta=60^{\circ}$, as the incoming flow into the factory building increases, the inside velocity distribution becomes uniformly.

  • PDF