• Title/Summary/Keyword: Open Area

Search Result 2,427, Processing Time 0.033 seconds

Study on the Assessment of Closed Trails at National Parks in the Baekdudaegan Mountains, South Korea

  • Kim, In-Kyu;Lee, Joon-Woo;Cho, Woo
    • Korean Journal of Environment and Ecology
    • /
    • v.29 no.1
    • /
    • pp.21-28
    • /
    • 2015
  • This study examined the habitat status of wild birds at closed-trails and the control group of opened-trails in the national park of the Baekdudaegan mountains. After evaluating each area based on this, it's aimed at being utilized as basic data for future national park management and opening of trails. Upon field investigations and analyzing existing literary materials, it was found that there were a total of 76 bird species living around the trails. Among them, it was confirmed that 60 species can breeding and 10 species are protected by law. Upon assessing the scores of each area according to the evaluation standards of this study, Area I had 7 scores, area II had 13 scores, area III had 5 scores, and area IV had 16 scores, showing that the control group open-trail area IV between Jeongryeongchi and Seongsamjae had the highest score, and that area III of Wolyeongdae~Chotdaebong~Daeyasan~Miljae~Wolyeongdae had the lowest score. Evaluation of closed-trail according to wild bird species (Avifauna) was attempted in this study, but there were more bird species living in open-trails, while also having higher evaluation scores. Therefore, if opening trail is needed in the future due to excessive desires of visitors or inevitable social demands, it is judged that various environmental factors including mammals highly affected by people should be evaluated to open up the sector with the lowest score. Also, it is judged that through methods such as reservation systems, the number of visitors should be controlled or night-time hikes should be prohibited so that nocturnal wildlife can freely use the trails.

On the Problems of EMC Test Site and EMC Antennas (EMC 측정 시험장과 EMC 안테나에 관한 문제점)

  • Kim, Ki-Chai
    • Journal of The Institute of Information and Telecommunication Facilities Engineering
    • /
    • v.2 no.1
    • /
    • pp.78-87
    • /
    • 2003
  • One of the most difficult and important problems associated with radiated electromagnetic emissions from digital devices are the determination of antenna factor and site acceptability of an open area test site. This paper presents the problems of the open area test site and EMC antennas far measuring electromagnetic interferences radiated from the equipements. It seems desirable that the antenna factor of EMC antennas be revised to the antenna factor with zero reflection presented in this paper for accurate measurements.

  • PDF

Transmasseteric Approach for Open Reduction and Internal Fixation of Mandible Subcondylar Fracture (깨물근을 통한 하악골 관절돌기하부골절의 관혈적 정복 및 내고정술)

  • Kim, Hak-Soo;Kim, Seong-Eun
    • Archives of Plastic Surgery
    • /
    • v.37 no.2
    • /
    • pp.161-168
    • /
    • 2010
  • Purpose: Surgical approaches to the condylar neck and subcondyle area can cause some morbidity such as, facial nerve injury, time-consuming nature and external scar etc. So many surgeons hesitate using open reduction and internal fixation for the treatment of subcondylar fractures. We report open reduction and internal fixation of subcondylar fractures in 13 adult patients via transmasseteric approach. Methods: From 2007 to 2009, 13 adults with subcondylar fracture of mandible were treated with open reduction and internal fixation via transmasseteric approach. A preauricular incision was extended downwards in a curvilinear fashion in the cervicomastoid skin crease. Skin flap was elevated above the SMAS layer. Masseter muscle was splitted at the anteroinferior edge of the parotid gland. After the fracture was reduced, fixed with appropriate plates and screws. All operation were performed under general anesthesia. Results: Mean follow-up period was 13.3 months. There were no signs and symptoms of facial nerve injury, difficulty in mouth opening, or malocclusion. Dissection time was roughly within 30 minutes. Conclusion: Transmasseteric open reduction and internal fixation of mandible subcondylar fracture can be performed with excellent visualization, and inconspicuous scar. It also offers swift access to the subcondylar area while substatially reducing the risk to the facial nerve and eliminating the complications associated with transparotid approaches.

Measure and Analysis of Open-Close Frequency of Mouth and Eyes for Sleepiness Decision (졸음 판단을 위한 눈과 입의 개폐 빈도수 측정 및 분석)

  • Sung, Jae-Kyung;Choi, In-Ho;Park, Sang-Min;Kim, Yong-Guk
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.14 no.3
    • /
    • pp.89-97
    • /
    • 2014
  • In this paper, we propose real-time program that measure open-close frequency of mouth and eyes to detect drowsiness of a driver. This program detects a face to the CCD camera image using OpenCV library. Then that extracts each area using CDF for eye detection and Active Contour for mouth detection based on detected face. This system measures each frequency of Open-Close using extracted area data of eyes and mouth. We propose foundation technique how to perform sleepiness decision of users based on measurement data.

A Study on the Characteristics of an Unit Plan for a Tower Type Super-High-Rise-Residence (탑상형 초고층 주거건축의 단위평면 특성에 관한 연구 - 외기접합 면수별 공간구성 특성을 중심으로 -)

  • 이용광
    • Korean Institute of Interior Design Journal
    • /
    • v.13 no.5
    • /
    • pp.90-97
    • /
    • 2004
  • The purpose of this study is to grasp the spatial characteristic of the unit plan for a Super-High-Rise-Residence. This study is focused on the open air contact sides for a tower type Super-High-Rise-Residence. A tower type Super-High-Rise-Residence which has open air contacts from 1 to 3.5 sides differed in spatial characteristics of the unit plan for other apartment units. The current study analyzed 188 unit plans for the size of 40 pyong or larger in Seoul and the metropolitan areas which have been built since 1990. Open air contact side was classified as under 2 sides, 2 sides, and over 2 sides. The unit plan which belong to each open air contact side was Investigated according to the location of public area, the relationship between livingroom and master bedroom, and a method of entry to the master bedroom. The results of this study are as follow: According to increase open air contact sides is changed the location of public area in unit plan from an typical arrangement to various arrangement. Also the relationship between livingroom and master bedroom becomes loose and in a method of entry to the master bedroom increase an indirect approach through other room.

Banner Control Automation System Using YOLO and OpenCV (YOLO와 OpenCV기술을 활용한 현수막 단속 자동화 시스템 방안)

  • Dukwoen Kim;Jihoon Lee
    • Journal of the Semiconductor & Display Technology
    • /
    • v.22 no.4
    • /
    • pp.48-52
    • /
    • 2023
  • From the past to the present, banners are consistently used as effective advertising means. In the case of Korea, there are frequent situations in which hidden advertisements are installed. As a result, such hidden advertisement materials may damage urban aesthetics and moreover, incur unnecessary manpower consumption and waste of money. The proposed method classifies the detected banners into good banner and bad banner. The classification results are based on whether the relevant banners are installed in compliance with legal guidelines. In the process, YOLO and Open Computer Vision library are used to determine from various perspectives whether banners in CCTV images comply with the guidelines. YOLO is used to detect the banner area in CCTV images, and OpenCV is used to detect the color values in the area for color comparison. If a banner is detected in the video, the proposed method calculates the location of the banner and the distance from the designated bulletin to determine whether it was installed within the designated location, and then compares whether the color used in the banner is complied with local government guidelines.

  • PDF

Study on change of Climate Environment at Waterfront in Busan - About Haeundae and Gwanganli - (부산해안지역 워터프런트의 기후환경변화 연구 - 해운대, 광안리를 대상으로 -)

  • Doe, Geun-Young;Park, Soo-Yong
    • Journal of Navigation and Port Research
    • /
    • v.34 no.1
    • /
    • pp.65-70
    • /
    • 2010
  • Recently, the number of design for open-spaces at waterfront, such as open-air restaurant and cafeteria, has been increasing to provide openness and natural environment of waterfront. However, when planning open-air restaurant and cafeteria, it is essential to investigate the climate characteristic of waterfront, especially wind environment, since the waterfront has a special quality of climate like low-temperature and strong wind which differs from downtown or inland. In this study, wind environments of Haeundae, Suyoungman, and Gwanganli, the famous waterfronts in Busan, were investigated for design of open-air restaurants and open cafeterias. The main results were as follows. 1) the waterfront area of Haeundae, Suyoungman, and Gwanganli is suitable for open-air restaurant and open cafeterias; and 2) the appropriate period for open space in this area is from the end of March to November.

Variation of Manning's Coefficient due to Vegetation in Open Channel (개수로내 식생에 의한 Manning계수의 변화)

  • Kwon, Kab-Keun;Kim, Hyung-Seok;Yoon, Sung-Bum
    • 한국방재학회:학술대회논문집
    • /
    • 2008.02a
    • /
    • pp.401-404
    • /
    • 2008
  • The vegetation in the surrounding area of river is a primary factor to increase water level during flood. The influence of vegetation on the river flow in a bank has been investigated by using a hydraulic experiment. For a hydraulic experiment square-shaped piers are used as a model of unsubmerged rigid vegetation in a open channel. For fully developed uniform flows, the water elevation of the experiment was measured as varying the interval of piers and the porosity which presents the fraction of water flowing area in the cross-sectional area. The Manning's roughness coefficient, which implicates energy losses due to the vegetation, was obtained by using the experimental data. As a result, the energy losses were varied when the distance of piers and the porosity of area were changed, and the Manning's coefficient increased nonlinearly when a water elevation increased.

  • PDF

Flow Analysis of the Oxidizer Manifold for a Liquid Rocket Combustor using OpenFOAM (OpenFOAM을 이용한 액체 로켓 연소기의 산화제 매니폴드 내 유동 해석)

  • Joh, Mi-Ok;Han, Sang-Hoon;Kim, Seong-Ku;Choi, Hwan-Seok
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.40 no.9
    • /
    • pp.781-788
    • /
    • 2012
  • Flow in the oxidizer manifold of a liquid rocket combustor has been analysed using an open source CFD toolbox, OpenFOAM. The applicability of OpenFOAM to the problems with complex geometries involving porous media zones for simulating the pressure drop induced by the injectors has been evaluated by performing turbulent, incompressible steady-state flow analysis. The usefulness and applicable area of the OpenFOAM as a design evaluation and analysis tool will be confirmed and enlarged by further evaluation with various computational cases representing major physical phenomena in rocket combustion devices.

Impact Assessment of the Damage by a Pool Fire in Yard Storage Facilities of a Container Terminal (컨테이너 터미널 옥외저장소에서의 액면화재에 대한 피해영향 평가)

  • Hwang, Man Woong;Lee, Ik Mo;Hwang, Yong Woo;Chun, Young Woo
    • Journal of Korean Society of Disaster and Security
    • /
    • v.9 no.2
    • /
    • pp.33-42
    • /
    • 2016
  • Domestic harbor yard storage facilities are a place specifically located in a container terminal for import and export of packaged dangerous goods, and due to the recent relaxed criteria for the secured open area, concerns for the extended damage upon accidents are increasing. In this study, the impact of damages by radiant heat was analyzed through a simulation of a pool fire caused by the leakage of flammable liquids from a tank container. As a result, it was analyzed that the distance of radiant heat according to threshold damage levels was beyond the current criteria of the secured open area, and the structural damage of adjacent containers could happen within a very short time if they were exposed to the early pool fire continuously. It is considered that this study will be helpful in preparing the proper criteria for the secured open area between yard storage facilities in a container terminal.