• 제목/요약/키워드: Onset time method

검색결과 188건 처리시간 0.038초

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF

식물생장촉진 Bacillus sp. SB19 균주의 케일 처리에 대한 가뭄 스트레스 완화 효과 (Mitigation Effect of Drought Stress by Plant Growth-promoting Bacterium Bacillus sp. SB19 on Kale Seedlings in Greenhouse)

  • 김다연;이상엽;김정준;한지희
    • 한국유기농업학회지
    • /
    • 제24권4호
    • /
    • pp.833-847
    • /
    • 2016
  • 가뭄은 농작물의 생산성을 저해하는 주요 원인 중 하나이며, 잎을 먹는 쌈채류의 경우 물 부족 스트레스에 더 치명적일 수 있다. 본 연구는 케일 유묘에 대한 식물생육촉진 균주(PGPB)의 가뭄 내성 효과를 알아보기 위해 수행되었다. 쌈채류의 토양 및 근권 토양으로부 터 형태학적으로 구분되는 146개의 콜로니를 분리하고 온실 생물검정을 통해 케일 생육촉진이 우수한 균주 SB19를 최종 선발하였다. SB19 균주는 케일 재배 토양으로부터 분리하였으며 16S rRNA 유전자 염기서열 분석 결과 Bacillus sp.로 확인되었다. Bacillus sp. SB19 균주를 처리한 케일에 7일 간 수분 부족 스트레스를 유도하고 7일째에 가뭄 피해 조사 후 모든 처리구에 1회 관수하였다. 이후 다시 7일 간 수분 부족 스트레스를 주어 14일째에 케일의 내건성 증진 여부를 조사하였다. 가뭄 조건 7일째에 $10^6$$10^7cell\;mL^{-1}$ 농도의 SB19 균주를 처리한 케일에서 무처리와 비교하여 가뭄 스트레스 경감 효과를 보였다. 7일째에 모든 처리구에 관수 후 다시 가뭄 스트레스를 주었을 때에도 $10^6$$10^7cell\;mL^{-1}$ 농도의 SB19 균주 처리구에서 무처리구와 비교하여 가뭄 피해 경감 효과가 있었으며, 7일째와 14일째 모두에서 $10^7cell\;mL^{-1}$ 농도의 SB19 균주 처리구에서 가뭄 피해의 완화 정도가 가장 효과적인 것으로 나타났다. $10^6cell\;mL^{-1}$ SB19 균주 처리구에서는 물 부족으로 인한 잎의 노화가 $10^7cell\;mL^{-1}$ 농도 처리구에 비해 빠르게 발생하였다. 본 연구 결과를 바탕으로 유용 미생물과 식물의 상호작용이 식물의 물 이용률을 증진시키는 중요한 역할을 하고 약한 가뭄 조건에서 쌈채류의 품질을 향상시킬 수 있는 방안이 될 수 있을 것이라고 예측한다. 즉, 미생물학적인 환경 스트레스 극복 방법으로서의 가치를 뒷받침하는 것이라 할 수 있다.

복잡한 흉막강내 공간차지병소의 흉강경적 흉막 유착박리술 및 박피술 (Video-Assisted Thoracoscopic Pleural Adhesiotomy and Decortication for Complicated Pleural Space Occupying Lesions)

  • 조민섭;조덕곤;문석환;문영규;강철웅;조규도;조건현
    • Journal of Chest Surgery
    • /
    • 제42권3호
    • /
    • pp.350-354
    • /
    • 2009
  • 배경: 복잡한 흉막강내 공간차지병소(complicated pleural space occupying lesions, SOL)의 치료는 그 병의 진행정도와 상태에 따라 흉막천자, 폐쇄식흉강삽관술, 섬유소용해제의 주입, 그리고 흉강경이나 개흉술을 이용한 수술적 치료 등이 선택될 수 있다. 특히 비디오 흉강경 수술이 발달함에 따라 개흉술의 단점을 극복하여 보다 적극적으로 비디오 흉강경을 이용한 수술(VATS)을 시행하여 좋은 결과를 보고하고 있다. 이에 저자들은 비디오 흉강경을 이용한 흉막 유착박리술과 박피술의 유용성과 조기수술의 효과에 대해 알아보고자 의무기록과 방사선 기록을 후향적으로 조사, 분석하였다. 대상 및 방법: 1996년 5월부터 2006년 4월까지 complicated plerual SOL 환자 64명(평균연령 $41.8{\pm}19.8$세)에서 시행한 65예의 VATS 흉막 박피술과 흉막 유착박리 술을 분석하였다. 결과 분석을 위해 수술후 단순흉부방사선 소견을 임의로 4군(Class)으로 나누었다. Class I: no or minimal pleural lesion, class II: blunting of costophrenic angle and mild pleural thickening, class III: elevated diaphgram or persistent lung collapse, class IV complicated or recurrent effusion. 결과: 수술전 환자들은 진단적, 치료적 시술로 41예에서 흉막천자술, 10예에서 pigtail catheter 삽입술, 11예에서 폐쇄식흉강삽관술, 그리고 10예에서 섬유소용해제 주입을 받았다. 증상발현 후부터 수술까지의 기간이(증상발현기간)평균 18.4일이었고, 심각한 합병증이나 사망예는 없었다. 수술결과 Class I 28예, II 13예, III 19예, IV 5예였으며, 증상발현기간과 수술시간과의 관계에서 통계적으로 유의한 차이를 보였다. 또한 증상발현기간 18일을 기준으로 조기수술군과 지연수술군으로 나누어 비교하면 단순흉부방사선 소견 class별로 빈도수에서 두군간에 유의한 차이를 보였다. 결론: 비디오 흉강경을 이용한 흉막 유착제거 술과 박피술은 Complicated pleural SOL 치료를 위한 안전하고 효과적인 방법이고, 보다 좋은 결과를 위해서 조기에 적극적인 수술이 필요하다.

반복성 복통증 환아의 역학적 특징에 관한 조사 (A Study on Epidemiologic Characteristics of Recurrent Abdominal Pain in Elementary School Children)

  • 오상현;양은석;박상기;박영봉;박종;박상학;문경래
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • 제2권1호
    • /
    • pp.21-29
    • /
    • 1999
  • 목 적: 학동기 소아들의 반복성 복통의 발생빈도, 임상증상, 의료기관 이용양상, 선택기준 및 관련된 요인을 조사하여 반복성 복통 환아의 특징, 증상의 발현 및 유지에 영향을 줄 수 있는 요인을 알아보고, 반복성 복통 환아의 의료기관 이용양상과 문제점을 파악하여 향후 치료를 위한 기초 자료를 제공하고자 실시하였다. 방 법: 1998년 6월 광주시내 초등학교 학부모 1417명을 대상으로 반복성 복통의 발생빈도, 임상증상, 의료기관 이용양상을 알아보기 위하여 설문조사를 실시하였다. 결 과: 1) 총응답자는 1417명, 남자 715명, 여자 702명이었고, 남녀비 1.02:1 평균나이는 10.3세였다. 2) 반복성 복통증의 발생 빈도는 18.9%이었다. 남자는 18.4%, 여자는 19.2%였다. 복통의 지속시간은 10분 이내가 68.5%였다. 3) 정확한 진단을 받지 못한 경우가 62.5%였고, 66.3%가 치료를 받았고, 67.5%가 치료시 증상 호전을 보였다. 민간요법을 실시한 경우도 66%를 차지하였다. 4) 치료 의료기관은 소아과 35.2%로 많았으나, 약국 및 내과의 이용률도 30%정도를 차지하였다. 연령이 증가함에 따라 소아과 이용률이 감소하고 내과의 이용율이증가하였다. 의료기관의 선택기준은 거리의 근접성이 36.3%로 가장 많았고, 의료인의 친절도, 치료의 질 순이었다. 5) 동반증상은 55.5%에서 있었고, 두통이 30.9%로 가장 많았고, 흉통, 현기증, 구토 순이었고, 동반 증상이 없는 경우도 44.5%였다. 6) 반복성 복통의 발생시기는 하루 중 식후가 35.3%로 가장 많았고, 식사전, 수업중 순이었다. 주내 변동은 월요일이 21.4%로 가장 많았으며, 점차 감소하여 토요일이 가장 낮았다. 7) 복통의 발생부위는 배꼽주위가 38%로 가장 많았고, 심와부 등 중앙부에 위치하였으며, 통증의 성격은 작열통이 36.9%로 가장 많았다. 결 론: 반복성 복통 환아는 대부분 정확한 진단을 받지 못하고, 전문적인 치료없이 대증적인 치료 및 민간요법이 많이 시행되고 있었다. 연령이 증가함에 따라 소아과 이외의 타과의 이용률이 증가하였다. 반복성 복통에 대한 올바른 이해와 함께 정확한 진단 및 전문적인 의료기관의 선택이 필요하고 이에 대한 홍보 및 대응책이 필요하다.

  • PDF

급성 상행대동맥 박리증 수술에서 액와동맥 삽관술의 역할 (The Role of Axillary Artery Cannulation in Surgery for Type A Acute Aortic Dissection)

  • 유지훈;박계현;박표원;이영탁;김관민;성기익;양희철
    • Journal of Chest Surgery
    • /
    • 제36권5호
    • /
    • pp.343-347
    • /
    • 2003
  • 배경: 급성 상행대동맥박리증 수술 시 대퇴동맥이 동맥삽관 장소로 주로 이용되어 왔으나 최근 관류 장애 및 역행성 색전증의 발생 위험이 적은 액와동맥삽관이 증가하고 있다. 이에 기존의 대퇴동맥 삽관술과 액와동맥 삽관술을 이용한 수술성적을 비교하여 액와동맥 삽관술의 안전성과 유용성을 고찰하고자 하였다. 대상 및 방법: 1995년 10월부터 2001년 9월까지 급성 상행대동맥박리증으로 수술을 받은 71명을 대상으로 의무기록을 후향적으로 검토하여 수슬 전의 상태, 수술범위 및 방법, 수술 후 경과를 분석하였다. 대퇴동맥삽관은 40명으로 평균 연령은 57세, 액와동맥삽관은 31명으로 평균 56세였다. 결과: 액와동맥군의 평균 체외순환시간과 순환정지시간은 각각 207분과 39분으로 대퇴동맥군의 263분과 49분보다 의미있게 짧았고(p<0.05), 수술 후 입원기간 역시 액와동맥군에서 15일로 대퇴동맥군의 35일에 비하여 의미있게 단축되었다(p<0.05). 수술 후 사망률(액와동맥군 6.5%, 대퇴동맥군 10%)과 영구적 신경계 합병증 발생률(액와동맥군 3.2%, 대퇴동맥군 2.5%)은 의미있는 차이를 보이지 않았으나 일시적 신경계 합병증의 발생률은 액와동맥군에서 12.9%, 대퇴동맥군에서 25%로 의미있는 차이를 보였다(p<0.05). 대퇴동맥군 중 2명의 환자에서 수술 중 대동맥궁 분지의 관류 부전이 발견되어 삽관 위치의 변경이 필요하였다. 액와동맥 삽관에 따른 합병증으로는 1명의 환자가 정중신경 손상을 경험하였다. 결론: 급성 상행대동맥박리증 수술에서 액와동맥 삽관은 뇌허혈시간의 단축과 이에 따른 수술 후 신경계 합병증의 발생률을 낮추는 데 기여하는 안전한 술식으로 판단된다. 또한, 이에 따라 대동맥궁에 내피 손상부위가 있는 환자에 대하여 보다 적극적이고 광범위한 수술 적용을 가능하게 한 것으로 판단된다.

응급실로 내원한 천식환자들의 임상적 특성 (Clinical Characteristics of Asthmatic Patients Who Visited Emergency Room)

  • 서정경;이소라;이상엽;이상화;조재연;심재정;인광호;강경호;유세화
    • Tuberculosis and Respiratory Diseases
    • /
    • 제44권2호
    • /
    • pp.290-297
    • /
    • 1997
  • 연구배경 : 기관지천식은 가역성 기도폐쇄, 기관지 과민증 및 기도점막의 염증성 변화가 특징인 호흡기 질환으로 적절한 치료가 질병의 예후에 중요한 영향을 미치며, 최근 천식의 발생기전 및 병태생리에 대한 연구가 활발히 진행되고 천식치료에도 많은 발전이 이루어지고 있음에도 불구하고, 오히려 전세계적으로 기관지천식의 유병률 및 사망률, 천식발작으로 인한 응급실 내원빈도는 증가하는 추세이다. 응급실 내원 환자의 과거력상 응급실 내원빈도가 많을수록 천식치료에 문제점이 있고 예후도 나쁘다는 보고가 있어, 응급실로 내원한 천식환자들의 임상적 특성의 분류가 치료 계획, 환자 교육과 관리 및 예후 예측에도 도움이 될것으로 사료되어 저자들은 천식발작으로 응급실로 내원한 환자들을 대상으로 연구를 시행하였다. 방 법 : 1년간 응급실에 기관지 천식발작으로 내원한 103명의 환자를 대상으로 과거력 및 천식 발작후 응급실 내원전까지의 상황등을 문진하였고 응급실 내원당시 최대 호기말 유속, 동맥혈 가스분석, 흉부 X선등을 시행하여 환자의 상태를 분석하였으며 입원 여부, 입원기간, 외래 추적관찰여부등으로 응급실로 내원한 천식환자들의 임상적 특성 및 예후를 조사하였다. 결 과 : 대상환자는 총 103명으로 남자 47명(45.6%), 여자 56명(54.4%) 이었고 평균 연령은 48.6세, 연령분포 50대가 27.2%로 가장 높았다. 천식진단후 1~5년사이의 환자가 42명 (40.8%)으로 가장 많았고, 과거력상 48명(46.6%)이 천식발작으로 응급실 내원 경험이 있었으며 2회이상 응급실 내원경력이 있는 환자는 27명(26.3%)이었고 내원환자중 79명(76.7%)이 교감신경항전 흡입제를, 48명(46.6%)이 부신피질 호르몬 흡입제를 사용한 적이 있었으나 그중 56%만이 적절한 흡입방법을 구사하였다. 응급실 내원경위는 환자 스스로 내원한 경우가 68명(66%)으로 가장 높았고, 월별 응급실 내원빈도률 살펴보면 12월과 5월에 가장 높았으며, 응급실 내원시간별로 보면 낮시간(오전 8시~오후 4시)이 53.4%로 가장 많았다. 천식악화요인으로는 상기도 감염(56.3%), 치료 중지(15.5%), 불완전한 치료(11.7%)가 주요 원인이었고 천식발작시작에서 응급실 도착까지 평균시간은 14.2시간이었고 천식발작후 79명(76.7%)이 교감신경 항진 흡입제를 사용하였으며 사용횟수는 평균 6.4회였다. 내원시 측정한 최대 호기유속은 펑균 166.7L/min, 내원시와 과거 최대호기유속 또는 예상 최대호기유속 의비는 평균 43.2%였다. 동맥혈 가스분석 검사상 고탄산가스혈증을 보인 환자는 총 50명으로 이중 7명(14%)만이 인공환기를 시행하여 비교적 좋은 예후를 보였고 내원환자중 17명(16.5%)은 응급실에서 치료후 내원 24시간내 귀가하였고 80명(77.7%)은 일반 병동에, 6명(5.8%)은 중환자실에 입원하여 치료를 받았으며 평균 입원일수는 11.2일이었다. 예후는 좋은편으로 총환자 모두 사망없이 회복되었고 외래 추적관찰은 59명(57%)에서 가능하였으며 증상소실후 천식정도를 분석한 결과 64.9%가 경미한 천식으로 나타났다. 결 론 : 응급실에 내원한 천식환자들은 주로 경미한 천식이 상기도 감염등에 의해 악화된 경우가 많았고 치료예후는 비교적 양호하였으나 퇴원후 적절한 천식치료를 받는 경우는 많지 않았다.

  • PDF

심장 수술 후 심방세동 발생의 예측 인자로서 혈중 BNP 농도 (Plasma Levels of Brain Natriuretic Peptide Predict Postoperative Atrial Fibrillation in Patients Undergoing Heart Surgery)

  • 권진태;정태은;이장훈;이동협
    • Journal of Chest Surgery
    • /
    • 제40권6호
    • /
    • pp.407-413
    • /
    • 2007
  • 배경: 혈중 BNP 농도가 심방세동 발생과 관련 있다는 여러 보고가 있다. 본 연구의 목적은 혈중 BNP 농도가 술 후 심방세동의 발생에 유용한 예견인자인지 알아보고 술 후 BNP 수치의 변화와 심방세동 발생시기 및 심방세동이 정상 동율동으로 돌아오는 시기를 알아보고자 하였다. 대상 및 방법: 2005년 1월 1일부터 2006년 2월 28일까지 개심술을 받은 환자 중 심방부정맥의 병력이 없는 82명의 환자를 대상으로 하였다. 혈중 BNP 농도 측정을 위한 혈액 채취는 술 전부터 술 후 7일째까지 매일 하였다. 술 후 심전도 검사는 퇴원 전까지 매일 시행하였다. 결과: 환자는 술 후 심방세동 발생 유무에 따라 두 군으로 나누었다. 술 후 심방세동은 26명(31.7%)에서 발생하였다. 심방세동 없는 군과 발생군 사이에 나이, 성별, 술 전 좌심실 구혈률, 고혈압, 좌심실 비대, 베타 차단제 복용 유무에 대해 통계학적인 의미 있는 차이는 없었다. 판막 수술을 받은 환자에서 술 후 심방세동의 발생이 많았다(39.3% vs 76.9%, p=0.002). 술 전 좌심방 크기는 심방세동 발생군에서 의미 있게 컸다($43.8{\pm}10.3 m$ vs $49.8{\pm}11.5 mm$, p=0.029). 술 전 혈중 BNP 농도는 심방세동 발생군에서 의미 있게 높았다($144.1{\pm}20.8 pg/mL$ vs $267.5{\pm}68 pg/mL$, p=0.034). 심방세동군에서 술 후 BNP 수치는 술 후 3일째 가장 높았고 심방세동 발생은 술 후 3일 이내가 가장 많이 발생하였고 술 후 일주일 이내 대부분 정상 동율동으로 돌아왔다. 결론: 혈중 BNP 농도의 증가는 심장 수술 후 심방세동 발생을 예측하는 데 유용한 인자이다. 심방세동 발생의 위험인자가 있는 경우 술 후 적극적으로 예방적 항부정맥제 사용을 고려해야 한다.