• Title/Summary/Keyword: One-incision

Search Result 345, Processing Time 0.028 seconds

Orbital Floor Reconstruction Using Endoscope and Selected Urethral Balloon Catheter (내시경과 선택적 도뇨관 풍선을 이용한 안와하벽복원술)

  • Choi, Hwan-Jun;Lee, Joo-Chul;Lee, Hyung-Gyo;Kim, Jun-Hyuk
    • Archives of Plastic Surgery
    • /
    • v.38 no.1
    • /
    • pp.35-42
    • /
    • 2011
  • Purpose: Blow-out fractures can be reduced using various methods. The orbital reconstruction technique using a balloon under endoscopic control has advantages over other methods. However, this method has some problems too, such as postoperative follow-up, management of the balloon catheter, and reduction of the posterior orbital floor. Thus, we developed a simple, effective method for orbital floor reduction that involves molding and shaping the antral balloon catheter. Methods: A 0, 30, or $70^{\circ}$, 4-mm endoscope was placed though a two-point, 5-mm maxillary antrostomy. The balloon catheter is placed directly at the orbital apex to reconstruct the anterior shelf (spherical shape), while it is turned in a U-shape towards the anterior maxilla for the posterior shelf (elliptical shape). Orbital floor defects, compound or comminuted fractures are reconstructed with alloplastic materials through an open lid incision under the endoscopic control. Results: This technique was applied to ten patients with orbital floor fractures: five anterior shelf and five posterior shelf fracture, respectively. Four of the patients had zygomatico-orbital fractures, while the rest had isolated orbital floor fractures. Two patients were given porous polyethylene implants Synpor$^{(R)}$) and three underwent reconstruction with a resorbable mesh plate. No complication associated with this technique was identified. Conclusion: The freestyle placement and selection of a urinary balloon catheter under endoscopic control and the preoperative estimation of the volume enhanced the stabilization of the orbital contour. This method improves the adaptation of the orbital floor without the risk of injuring the surrounding orbital contents, dissecting blindly, or using sharp traction. One drawback of this method is the patient's discomfort from the catheter during treatment.

Face Reconstruction Using Lateral Intercostal Artery Perforator-Based Adipofascial Free Flap

  • Jeong, Jae Hoon;Hong, Jin Myung;Imanishi, Nobuaki;Lee, Yoonho;Chang, Hak
    • Archives of Plastic Surgery
    • /
    • v.41 no.1
    • /
    • pp.50-56
    • /
    • 2014
  • Background The aim of this study was to determine the efficacy of lateral intercostal artery perforator-based adipofascial free flaps for facial reconstruction in patients with facial soft tissue deficiency. Methods We conducted a retrospective study of five consecutive patients diagnosed with facial soft tissue deficiency who underwent operations between July 2006 and November 2011. Flap design included the area containing the perforators. A linear incision was made along the rib, which had the main intercostal pedicle. First, we dissected below Scarpa's fascia as the dorsal limit of the flap. Then, the adipofascial flap was elevated from the medial to the lateral side, including the perforator that pierces the serratus anterior muscle after emerging from the lateral intercostal artery. After confirming the location of the perforator, pedicle dissection was performed dorsally. Results Dominant perforators were located on the sixth to eighth intercostal space, and more than four perforators were found in fresh-cadaver angiography. In the clinical case series, the seventh or eighth intercostal artery perforators were used for the free flaps. The mean diameter of the pedicle artery was 1.36 mm, and the mean pedicle length was 61.4 mm. There was one case of partial fat necrosis. No severe complications occurred. Conclusions This is the first study of facial contour reconstruction using lateral intercostal artery perforator-based adipofascial free flaps. The use of this type of flap was effective and can be considered a good alternative for restoring facial symmetry in patients with severe facial soft tissue deficiency.

Orthodromic Transfer of the Temporalis Muscle in Incomplete Facial Nerve Palsy

  • Aum, Jae Ho;Kang, Dong Hee;Oh, Sang Ah;Gu, Ja Hea
    • Archives of Plastic Surgery
    • /
    • v.40 no.4
    • /
    • pp.348-352
    • /
    • 2013
  • Background Temporalis muscle transfer produces prompt surgical results with a one-stage operation in facial palsy patients. The orthodromic method is surgically simple, and the vector of muscle action is similar to the temporalis muscle action direction. This article describes transferring temporalis muscle insertion to reconstruct incomplete facial nerve palsy patients. Methods Between August 2009 and November 2011, 6 unilateral incomplete facial nerve palsy patients underwent surgery for orthodromic temporalis muscle transfer. A preauricular incision was performed to expose the mandibular coronoid process. Using a saw, the coronoid process was transected. Three strips of the fascia lata were anchored to the muscle of the nasolabial fold through subcutaneous tunneling. The tension of the strips was adjusted by observing the shape of the nasolabial fold. When optimal tension was achieved, the temporalis muscle was sutured to the strips. The surgical results were assessed by comparing pre- and postoperative photographs. Three independent observers evaluated the photographs. Results The symmetry of the mouth corner was improved in the resting state, and movement of the oral commissure was enhanced in facial animation after surgery. Conclusions The orthodromic transfer of temporalis muscle technique can produce prompt results by applying the natural temporalis muscle vector. This technique preserves residual facial nerve function in incomplete facial nerve palsy patients and produces satisfying cosmetic outcomes without malar muscle bulging, which often occurs in the turn-over technique.

Technological Trend of Endoscopic Robots (내시경 로봇의 기술동향)

  • Kim, Min Young;Cho, Hyungsuck
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.20 no.3
    • /
    • pp.345-355
    • /
    • 2014
  • Since the beginning of the 21st century, emergence of innovative technologies in robotic and telepresence surgery has revolutionized minimally access surgery and continually has advanced them till recent years. One of such surgeries is endoscopic surgery, in which endoscope and endoscopic instruments are inserted into the body through small incision or natural openings, surgical operations being carried out by a laparoscopic procedure. Due to a vast amount of developments in this technology, this review article describes only a technological state-of-the arts and trend of endoscopic robots, being further limited to the aspects of key components, their functional requirements and operational procedure in surgery. In particular, it first describes technological limitations in developments of key components and then focuses on the description of the performance required for their functions, which include position control, tracking, navigation, and manipulation of the flexible endoscope body and its end effector as well, and so on. In spite of these rapid developments in functional components, endoscopic surgical robots should be much smaller, less expensive, easier to operate, and should seamlessly integrate emerging technologies for their intelligent vision and dexterous hands not only from the points of the view of surgical, ergonomic but also from safety. We believe that in these respects a medical robotic technology related to endoscopic surgery continues to be revolutionized in the near future, sufficient enough to replace almost all kinds of current endoscopic surgery. This issue remains to be addressed elsewhere in some other review articles.

Experimental Study for Nerve Regeneration Using Tubes Filled with Autogenous Skeletal Muscle in a Gap of Rabbit Sciatic Nerves (백색 가토 좌골 신경의 신경 결손부위에서 자가 골격근 충진 도관을 이용한 신경재생 연구)

  • Lee, Jun-Mo;Shin, Sung-Jin;Seo, Jeong-Hwan;Song, Chang-Ho
    • Archives of Reconstructive Microsurgery
    • /
    • v.12 no.1
    • /
    • pp.1-12
    • /
    • 2003
  • The bridging of nerve gaps is still one of the major problems in peripheral nerve surgery. To evaluate the role of silicon tube in nerve regeneration, gaps were made by resection of tibial components of sciatic nerves of twenty-five New Zealand rabbits. The gaps were divided into five groups. In group I, the tibial components of sciatic nerves were isolated and the incision immediately closed. In group II, 1-cm segments of the nerve were removed and the silicon tubes filled with autogenous skeletal muscle were sutured in place. In group III, 1-cm segments of the nerve were removed and the silicon tubes filled without muscle were sutured in place. In group IV, 2-cm segments of the nerve were removed and the silicon tubes filled with autogenous skeletal muscle were sutured in place. In group V, 2-cm segments of the nerve were removed and the silicon tubes filled without muscle were sutured in place. At 16th week, the eletromyography, the light and transmission electron microscopy were performed. Nerve conduction study stimulating sciatic nerve proximal to the lesion and recording at gastrocnemius muscle showed that the compound muscle action potentials of the group II with 1 cm nerve defect filled with muscle were higher amplitudes than the group III without muscle. Compound muscle action potentials of the group IV with 2 cm defect filled with muscle showed similar results in comparison with the group V. The light and transmission electron microscpy showed that a good morphological pattern of nerve regeneration in 1 cm gap than 2 cm and in gap with muscle than gap without muscle.

  • PDF

Correction of Distal Interphalangeal Joint Extension Lag Using Spiral Oblique Retinacular Ligament Reconstruction (나선빗인대 재건을 이용한 원위지관절 신전장애의 교정)

  • Moon, Kyung Hwan;Kim, Jin Soo;Lee, Dong Chul;Ki, Sae Hwi;Roh, Si Young;Yang, Jae Won
    • Archives of Plastic Surgery
    • /
    • v.33 no.4
    • /
    • pp.480-484
    • /
    • 2006
  • Purpose: A lot of surgical techniques were tried to correct extension lag of distal interphalangeal joint. Spiral oblique retinacular ligament reconstruction is the one of correction techniques. Methods: From January 2004 to January 2005, a total of 13 extension lag of distal interphalangeal joint corrections were performed using spiral oblique retinacular ligament reconstruction for 11 patients. After dorsal incision exposing from base of distal phalanx to proximal phalanx, the new ligament(half of lateral band or graft tendon) lies distally at the dorsum of the distal phalanx and passes volarly and proximally along the side of the middle phalanx and anterior and obliquely across the front of the proximal interphalangeal joint to the opposite side of the digit at the proximal phalanx. Results: 5 of 6 mallet finger deformities and 7 swan neck deformities were corrected, which were both extension lag of distal interphalangeal joint and hyperextension of proximal interphalangeal joint. Conclusion: As a result, spiral oblique retinacular ligament reconstruction is an effective and recommendable method for correction of mallet finger deformity and swan neck deformity.

Vaginal Reconstruction with Laparoscopic-perineal Rectosigmoid Colpopoiesis in Mayer-Rokitansky-Kuster-Hauser Syndrome: A Case Report (Mayer-Rokitansky-Kuster-Hauser 증후군 환자에서 회음부 복강경하 직결장질성형술을 이용한 질의 재건: 증례보고)

  • Bae, Sung-Gun;Lee, Sang-Yun;Cho, Byung-Chae;Choi, Kyu-Seok
    • Archives of Plastic Surgery
    • /
    • v.38 no.3
    • /
    • pp.333-337
    • /
    • 2011
  • Purpose: Various operations have been proposed to compensate for congenital absence of the vagina using ileal or colonic interposition. These methods involve laparotomy, which shows postoperative complications such as long scar and delayed recovery. One case of neovagina reconstruction with laparoscopic rectosigmoid colpopoiesis in Mayer-Rokitansky-Kuster-Hauser syndrome is presented to avoid laparotomic complications. Methods: Laparoscopic surgery was performed in a 27-year-old MRKH syndrome patient. After a cruciate incision, blunt dissection through two-finger wide space was created between the bladder and the rectum. A 14-cm rectosigmoid segment vascularized by a branch of sigmoid artery was isolated by laparoscopy. The distal end was sutured with vaginal vestibule mucosa. A continuity of intestine was restored by circular end-to-end proximate curved intraluminal stapler CDH29$^{(R)}$ through perineal opening. Results: Total operation time was 4 hr 15 min. Normal walking and ingestion were possible within 3 days and 4 days after surgery. The hospital stay was 7 days and the patient was followed up for 6 months. The neovaginal introitus was wide enough for inserting two fingers, and there has been no narrowing of the neovagina on palpation as confirmed by vaginogram. The patient had functional self-lubricating neovagina without excessive mucous production or the need for routine dilation or unnoticeable scar. Conclusion: The successful result of this laparoscopic vaginal reconstruction technique with rectosigmoid segment suggests that this technique can be considered for the option of vaginal reconstruction in girls with the MRKH syndrome.

Methylene Blue Dye-Induced Skin Necrosis in Immediate Breast Reconstruction: Evaluation and Management

  • Lee, Ji Hwan;Chang, Choong Hyun;Park, Chan Heun;Kim, June-Kyu
    • Archives of Plastic Surgery
    • /
    • v.41 no.3
    • /
    • pp.258-263
    • /
    • 2014
  • Background For early breast cancer patients, skin-sparing mastectomy or nipple-sparing mastectomy with sentinel lymph node biopsy has become the mainstream treatment for immediate breast reconstruction in possible cases. However, a few cases of skin necrosis caused by methylene blue dye (MBD) used for sentinel lymph node localization have been reported. Methods Immediate breast reconstruction using a silicone implant was performed on 35 breasts of 34 patients after mastectomy. For sentinel lymph node localization, 1% MBD (3 mL) was injected into the subareolar area. The operation site was inspected in the postoperative evaluation. Results Six cases of immediate breast reconstruction using implants were complicated by methylene blue dye. One case of local infection was improved by conservative treatment. In two cases, partial necrosis and wound dehiscence of the incision areas were observed; thus, debridement and closure were performed. Of the three cases of wide skin necrosis, two cases underwent removal of the dead tissue and implants, followed by primary closure. In the other case, the breast implant was salvaged using latissimus dorsi musculocutaneous flap reconstruction. Conclusions The complications were caused by MBD toxicity, which aggravated blood disturbance and skin tension after implant insertion. When planning immediate breast reconstruction using silicone implants, complications of MBD should be discussed in detail prior to surgery, and appropriate management in the event of complications is required.

Correction of Problematic Hypospadias with Dartos Fascia-Reinforced Flap and Slanted Incision of Fistula

  • Choi, Dong Sik;Lee, Jeong Woo;Yang, Jung Dug;Chung, Ho Yun;Cho, Byung Chae;Byun, Jin Suk;Choi, Kang Young
    • Archives of Plastic Surgery
    • /
    • v.40 no.6
    • /
    • pp.766-772
    • /
    • 2013
  • Background Hypospadias is the most common congenital malformation of the male urinary tract, wherein the urethral opening is located proximal to the normal site. Tubularized incised-plate urethroplasty reconstruction, and its efficacy, remains controversial due to the high recurrence rate. This study aimed to evaluate the results of dartos fascia-reinforced flap surgery in hypospadias patients with previous operative complications. Methods Nine patients (mean age, 12 years) who had previous one- or two-stage repair with TIP urethroplasty and suffered from urethrocutaneous fistulas or fissures as complications, underwent dartos fascia-reinforced flap surgery in our clinic between January 2010 and December 2012. The mean postoperative follow-up period was 6 months. Results Among the 9 patients, 7 had complete correction. In all the patients, the maximum uroflow angle was > $45^{\circ}$. No patient complained of an unnatural urinating position. The patients and parents gave very high satisfaction scores (4.7 points) with regard to the appearance of the outer genitalia. Conclusion The dartos fascia-reinforced flap could be a useful and reliable option for complications of hypospadias repair or fissure with the prepuce preserved, given that histological aspects vary and that the possibility of recurrence in the glanular region is high.

Emergency Surgical Management of Traumatic Cardiac Injury in Single Institution for Three Years

  • Joo, Seok;Ma, Dae Sung;Jeon, Yang Bin;Hyun, Sung Youl
    • Journal of Trauma and Injury
    • /
    • v.30 no.4
    • /
    • pp.166-172
    • /
    • 2017
  • Purpose: Thoracic traumas represent 10-15% of all traumas and are responsible for 25% of all trauma mortalities. Traumatic cardiac injury (TCI) is one of the major causes of death in trauma patients, rarely present in living patients who are transferred to the hospital. TCI is a challenge for trauma surgeons as it provides a short therapeutic window and the management is often dictated by the underlying mechanism and hemodynamic status. This study is to describe our experiences about emergency cardiac surgery in TCI. Methods: This is a retrospective clinical analysis of patients who had undergone emergency cardiac surgery in our trauma center from January 2014 to December 2016. Demographics, physiologic data, mechanism of injuries, the timing of surgical interventions, surgical approaches and outcomes were reviewed. Results: The number of trauma patients who arrived at our hospital during the study period was 9,501. Among them, 884 had chest injuries, 434 patients were evaluated to have over 3 abbreviated injury scale (AIS) about the chest. Cardiac surgeries were performed in 18 patients, and 13 (72.2%) of them were male. The median age was 47.0 years (quartiles 35.0, 55.3). Eleven patients (61.1%) had penetrating traumas. Prehospital cardiopulmonary resuscitations (CPR) were performed in 4 patients (22.2%). All of them had undergone emergency department thoracotomy (EDT), and they were transferred to the operating room for definitive repair of the cardiac injury, but all of them expired in the intensive care unit. Most commonly performed surgical incision was median sternotomy (n=13, 72.2%). The majority site of injury was right ventricle (n=11, 61.1%). The mortality rate was 22.2% (n=4). Conclusions: This study suggests that penetrating cardiac injuries are more often than blunt cardiac injury in TCI, and the majority site of injury is right ventricle. Also, it suggests prehospital CPR and EDT are significantly responsible for high mortality in TCI.