• 제목/요약/키워드: One-bottle adhesives

검색결과 14건 처리시간 0.025초

A study on the compatibility between one-bottle dentin adhesives and composite resins using micro-shear bond strength

  • Song, Minju;Shin, Yooseok;Park, Jeong-Won;Roh, Byoung-Duck
    • Restorative Dentistry and Endodontics
    • /
    • 제40권1호
    • /
    • pp.30-36
    • /
    • 2015
  • Objectives: This study was performed to determine whether the combined use of one-bottle self-etch adhesives and composite resins from same manufacturers have better bond strengths than combinations of adhesive and resins from different manufacturers. Materials and Methods: 25 experimental micro-shear bond test groups were made from combinations of five dentin adhesives and five composite resins with extracted human molars stored in saline for 24 hr. Testing was performed using the wire-loop method and a universal testing machine. Bond strength data was statistically analyzed using two way analysis of variance (ANOVA) and Tukey's post hoc test. Results: Two way ANOVA revealed significant differences for the factors of dentin adhesives and composite resins, and significant interaction effect (p < 0.001). All combinations with Xeno V (Dentsply De Trey) and Clearfil $S^3$ Bond (Kuraray Dental) adhesives showed no significant differences in micro-shear bond strength, but other adhesives showed significant differences depending on the composite resin (p < 0.05). Contrary to the other adhesives, Xeno V and BondForce (Tokuyama Dental) had higher bond strengths with the same manufacturer's composite resin than other manufacturer's composite resin. Conclusions: Not all combinations of adhesive and composite resin by same manufacturers failed to show significantly higher bond strengths than mixed manufacturer combinations.

수종의 One-bottle 상아질 결합제의 전단 결합 강도에 관한 연구 (THE STUDY ON SHEAR BOND STRENGTHS OF VARIOUS ONE-BOTTLE DENTIN ADHESIVES)

  • 오소희;김종수;권순원
    • 대한소아치과학회지
    • /
    • 제28권4호
    • /
    • pp.553-565
    • /
    • 2001
  • 새로운 상아질 결합제인 5세대 상아질 결합제는 산 부식, 전 처치, 그리고 접착의 복잡한 과정을 줄여줌으로써 시술 과정이 간단하고 시간이 단축되며 시술 도중의 오염에 대한 가능성을 줄여준다는 점에서 유용성이 부각되고 있다. One-bottle 상아질 결합제에 관한 기존의 연구들이 아세톤, 에탄올 등의 용매를 포함하는 상아질 결합제를 중심으로 이루어져 본 실험에서는 water-based 상아질 결합제를 우치(牛齒)의 상아질에 적용하여 얻어지는 상아질 결합력을 전단 결합 강도 측정과 주사 전자현미경 관찰을 통해 다음과 같은 결론을 얻었다. 1. 전단결합강도의 측정결과 II군 IV군, I군, III군의 순서로 II군에서 다소 높은 전단강도를 보였으나, 모든 군들간에는 유의 차가 없었다(p>0.05). 2. 주사 전자 현미경 소견에서 II군과 IV군에서 서로 유사한 양상의 잘 형성된 혼화층이 관찰되었으며 레진 테그의 측방 가지 또한 다수 관찰할 수 있었다.

  • PDF

상아질 접착제의 미세누출과 변연부 혼화층 (MICROLEAKAGE AND MARGINAL HYBRID LAYER OF DENTIN ADHESIVES)

  • 조영곤;김영관;안종모
    • Restorative Dentistry and Endodontics
    • /
    • 제27권1호
    • /
    • pp.34-43
    • /
    • 2002
  • The purpose of this study was to compare microleakage and marginal hybrid layer in class V restorations using two one-bottle adhesives and one self-etching adhesive. Class V cavity preparations with occlusal margins in enamel and gingival margins in dentin were pre-pared on buccal and lingual surfaces of 30 extracted human molar teeth. Prepared teeth were randomly divided into three treatment groups (n=30) and restored with three adhesives and composites: Single Bond/Filtek Z-250 (Group 1), Prime&BondNT/Esthet.X (Group 2), UniFil Bond/UniFil F (Group 3). For microleakage, samples were stored in room temperature water for 24 hours, thermocycled stained with 2% methylene blue dye, sectioned into halves, scored and analysed using Mann-whitney test and Wilcoxon signed rank sum test. For marginal hybrid layer, samples were sectioned into halves, treated with 10% phosphoric acid for 5 seconds, stored in 5% NaOCL solution for 24 hours, dried and gold coated. Occlusal and gingival margins of each sample were inspected under SEM. The results of this study were as follows ; 1. Microleakage at the occlusal margins was not evident in group 1 and group 2, but it showed in group 3 (p<0.05). 2. Microleakage in group 1 and group 3 was significantly lower than in group 2 at gingival margins (p<0.05). 3. Microleakage at gingival margins was greater than at occlusal margins in group 1 and group 2, but microleakage at occlusal margins was greater than at gingival margins in group 3 (p<0.05). 4. In group 1 and group 2, no gaps at occlusal margins showed. But gaps showed in group 3. Occlusal margins were free from a hybrid layer in all groups 5. The thickness of the marginal hybrid layers was 2.5~5 $\mu\textrm{m}$ thick in group 5 $\mu\textrm{m}$ thick in group 2 and 1.5 $\mu\textrm{m}$ thick in group 3. 6 There was no corelation between microleakage and thickness of marginal hybrid layer. In coclusion, the effect of dentin adhesives on microleakge in class V composite restorations was excellent when one-bottle adhesives were applied on enamel margin, and it was good when a self-etching adhesive was applied on dentinal margin. There was no corelation between microleakage and thickness of marginal hybrid layer.

One-Bottle 상아질 결합제의 유치 상아질에 대한 전단 결합 강도에 관한 연구 (SHEAR BOND STRENGTH OF "ONE-BOTTLE ADHESIVE" SYSTEM IN PRIMARY DENTIN.)

  • 김종빈;김종수
    • 대한소아치과학회지
    • /
    • 제27권3호
    • /
    • pp.444-456
    • /
    • 2000
  • 치아 교환시기에 발거된 치관이 건전한 유구치 상아질 표면을 One-Bottle 상아질 결합제인 Primer & Bond NT(DeTrey/Dentsply, Konstanz, Germany)와 Single Bond(3M Co. U.S.A.) 그리고 대조군으로 Scotchbond Multipurpose System(3M Co. U.S.A.)를 이용하여 각 제조자의 지침에 따라 처리하여 레진을 충전하고 광중합하였다. 1. 전단 결합 강도의 측정결과 Primer & Bond NT군인 1군, Single Bond군인 2군, 그리고 대조군으로 사용된Scotchbond Multipurpose System군인 3군의 순서로 1군에서 다소 높은 전단 결합 강도를 보였으나, 모든 군들간에는 통계적 유의차가 없었다(p>.05). 2. 주사 전자현미경 소견에서 1군 2군에서 서로 유사한 양상의 잘 형성된 혼화층이 관찰되었으며, 레진 테그와 측방 가지 또한 다수 관찰되었다. 반면 3군에서는 혼화층이나 측방가지의 형성이 1, 2군에 비해 다소 미약한 양상을 보였다.

  • PDF

Effect of rewetting agent on dentinal microtensile bond strength

  • Kang, Hee-Young;Cho, Young-Gon
    • 대한치과보존학회:학술대회논문집
    • /
    • 대한치과보존학회 2003년도 제120회 추계학술대회 제 5차 한ㆍ일 치과보존학회 공동학술대회
    • /
    • pp.568-568
    • /
    • 2003
  • I. Objectives This study investigated the effect of rewetting agent on dentinal microtensile bond strengths(${\mu}TBS$), using one bottle adhesives. II. Materials and Methods Non caries human molars were sectioned to exposed the superficial dentin surfaces, etched 15 seconds using 32% phosphoric acid and 10 seconds rinsed. Samples were randomly divided into two groups according to adhesives (Single Bond, One-Step) used. Each group were subdivided into five groups by different dentin surface treatment:15 second dry(D), blot dry(BD) or 15 second dry and rewetted with distrilled water(DW), Gluma Desensitizer(GD) and Aqua-Prep(AP) during 30 second, respectively.(omitted)

  • PDF

상아질접착제와 열순환에 따른 유동성 레진의 전단결합강도 비교 연구 (A COMPARATIVE STUDY OF SHEAR BOND STRENGTH OF FLOWABLE RESIN ASSOCIATED WITH DENTIN ADHESIVE SYSTEMS WITH THERMOCYCLING EFFECT)

  • 남기영
    • 대한치과보철학회지
    • /
    • 제44권4호
    • /
    • pp.383-393
    • /
    • 2006
  • Statement of problem : Limited research on flowable resin has been undertaken on its application directly on dentin associated with the adhesive systems. Purpose : This study was to evaluate the shear bond strengh and fracture aspect of flowable resin on human dentin with various types of dentin bonding adhesives with thermo cycling effect. Materials and methods: Filtek-Flow(3M ESPE, USA) was used as flowable resin and Eighty human molars were randomly divided into 4 groups : three dentin bonding adhesives (Scotchbond-Multipurpose : 3-step contentional system, One-Step : One-bottle system. Prompt L-Pop : All-in-one, self-etching primer) and 32% etching treatment without bonding adhesive as a control group. For evaluating their durability of bonding, each group was subdivided : storaging in the water at 37$^{\circ}C$(24 hours) and thermocycling (0$^{\circ}C$-55$^{\circ}C$, 30 seconds intervals, 1000 cycle). Shear bond strength tests were performed and resin-dentin interface and fracture mode were observed. Results were analysed by one-way ANOVA and Scheffe's multiple range test. Results and Conclusion : 1. At 0 cycle, the mean shear bond strength of One-Step exhibited the highest value of all groups(p<0.05), and there were no significant differences between Prompt L-Pop and Scotchbond-Multipurpose, Scotchbond-Multipurpose and control(p>0.05). After 1000 thermocycling, One-Step exhibited higher value than other groups(p<0.05), and there were no significant differences among other groups (p>0.05). 2. The shear bond strength of each group was significantly decreased after thermocycling except Scotchbond-Multipurpose (p>0.05). 3. The most common failure mode was adhesive type and mixed type, next in order.

IRM 임시수복이 상아질 접착제의 변연 미세누출에 미치는 영향 (THE INFLUENCE OF IRM TEMPORARY RESTORATIONS ON MARGINAL MICROLEAKAGE OF DENTIN ADHESIVES)

  • 조영곤;김현경;이영곤
    • Restorative Dentistry and Endodontics
    • /
    • 제28권1호
    • /
    • pp.1-10
    • /
    • 2003
  • This study investigated the influence of IRM on marginal microleakage of 5th generation adhesives. Class V cavities with gingival margins in dentin were prepared on both buccal and lingual surfaces of 60 extract-ed human molar teeth. Prepared teeth were randomly divided into six groups. Group 1 and 4 received no temporary restoration with IRM. Group 2 and 5 were covered with IRM mixed at P/L ratio(10g/1g). Group 3 and 6 were covered with IRM mixed at P/L ratio(10g/2g). The temporary restorations were removed mechanically with an ultrasonic scaler after one-week storage in distilled water. The cavities were restored using one of two adhesives and composites ; Single Bond/Filtek Z 250(Croup 1, 2 and 3), UniFil Bond/UniFil F(Group 4, 5 and 6). Following one day storage in distilled water, the restored teeth were thermocycled for 500 cycles(between $5^{\circ}C{\;}and{\;}55^{\circ}C$) and immersed in 2 % methylene blue for dye penetration testing. The results were analysed using Kruskal-Wallis Test, Mann-Whitney and Wilcoxon signed ranked test at a significance level of 0.05. The results of this study were as follows 1. Ranking of mean microleakage scores at the enamel margins was Group 10.05) 4. At the dentin margins, the microleakage of the group not pretreated with IRM was lower than that of the group pretreated with IRM. And the microleakage of UniFil Bond was lower than that of Single Bond. 5. Compared with microleakages between the enamel and dentin margins of each groups, Group 1, 2, 3, 4, 5 and 6 at dentin margin were higher microleakage than those at enamel margin. There were significant difference between enamel and dentin microleakage of Group 2 and 3(p<0.05).

수종의 단일병 접착제의 적용 시간 연장이 건조 상아질의 미세인장 결합강도에 미치는 영향 (EFFECT OF INCREASING APPLICATION TIME OF SINGLE BOTTLE ADHESIVES TO MICROTENSILE BOND STRENGTH OF DRIED DENTIN)

  • 김학근;김동준;황윤찬;오원만;황인남
    • Restorative Dentistry and Endodontics
    • /
    • 제30권6호
    • /
    • pp.435-441
    • /
    • 2005
  • 본 연구는 친수성 용매가 함유되어 있는 3종의 단일병 접착제의 적용 시간을 증가시켰을 때, 건조 상아질에 대한 재습윤의 효과가 있는지를 미세인장 결합강도의 측정을 통해 알아보고자 시행하였다. 실험대상은 최근에 발거한 상하악의 대구치로, 교합면 1/3부위의 치질을 치아 장축에 수직으로 절단하여 상아질을 노출시킨 후, $32\%$인산 (Unietch, Bisco Inc., Schaumburg, IL, USA)으로 15초간 산부식 하고 수세하였다. 치아는 무작위로 S군 (Single Bond), O군 (One-Step), P군 (Prime & Bond NT)으로 분류하였고, 각 군은 다시 3군 (W: 상아질 표면의 남아있는 과잉의 물을 수분에 적신 거즈를 이용하여 제거한 후, 즉시 단일병 접착제를 적용하고 광중합, D : 30초간 건조 한 후 즉시 단일병 접착제를 적용하고 광중합, 30: 30초간 건조 한 후 단일병 접착제를 30초간 적용하고 광중합)으로 소 분류하였다. 접착제 도포 후, 복합레진을 축조하고 접착계면이 $1mm^2$가 되도록 절단하여 각 군당 20개의 표본을 사용하여 미세인장 결합강도를 측정하였다. 5군,0군의 30초 적용군 (S-30, O-30)은 건조군 (S-D, O-D)보다 높은 미세인장 결합강도를 보였으며, S-30군의 경우 S-D군보다 통계학적으로 유의성 있게 높았다 (P<0.05). 하지만, P군의 30초 적용군 (P-30)은 건조군 (P-D)에 비해 미세인장 결합강도가 통계학적으로 유의성 있게 감소하였다 (P<0.05).

Micro-shear bond strength of resin-bonding systems to cervical enamel.

  • Shimada, Y.;Kikushima, D.;Iwamoto, N.;Shimura, R.;Ide, T.;Nakaoki, Y.;Tagami, J.
    • 대한치과보존학회:학술대회논문집
    • /
    • 대한치과보존학회 2001년도 추계학술대회(제116회) 및 13회 Workshop 제3회 한ㆍ일 치과보존학회 공동학술대회 초록집
    • /
    • pp.560.1-560
    • /
    • 2001
  • To evaluate the micro-shear bond strength of current adhesive systems to cervical and mid-coronal enamel. Materials and Two commercially available resin adhesives were investigated; a self-etching primer system(Clearfil SE Bond, Kyraray) and a one-bottle adhesive system(Single Bond, 3M) intended for use with the total-etch wet-bonding technique were employed. Two regions of enamel, cervical and mid-coronal regions, were chosen from the buccal surface of extracted molars and were then bonded with each adhesive system and submitted to the micro-shear bond test.(중략)

  • PDF

All-in-one adhesive를 이용한 치면열구전색술식이 전색재의 미세누출에 미치는 영향에 대한 연구 (THE EFFECT OF SEALING PROCEDURE USING ALL-IN-ONE ADHESIVE ON MICROLEAKAGE OF PIT AND FISSURE SEALANT)

  • 윤희훈;이재천;김정욱;김종철;한세현;이상훈
    • 대한소아치과학회지
    • /
    • 제31권3호
    • /
    • pp.486-494
    • /
    • 2004
  • 본 연구는 all-in-one adhesive를 사용하여 전색하는 술식을 통상적인 탈회 술식 및 single-bottle 결합제를 이용하여 전색하는 술식과 비교하여 법랑질과 전색재 사이의 미세누출의 차이를 알아보고자 하는 것이다. 75개의 제3대구치를 5군으로 나누어 1군을 대조군으로 하여 only Etching(1군), $Adper^{TM}$ Single $Bond^{TM}$(2군), $Adper^{TM}\;Prompt^{TM}$ L-Pop(3군), Ad-bond(4군), One-up bond F(5군)로 처리한 후 전색재 도포 후 열순환을 시 행한 뒤 미세누출도를 검사하여 다음과 같은 결론을 얻었다. 1. All-in-one adhesive를 사용한 3, 4, 5군은 1군에 비해 유의성 있게 높은 평균미세누출도를 보였다(p<0.05). 2. 가장 낮은 평균미세누출도는 2군(0.14)에서 보였고 1군(1.05), 3군(1.65), 4군(2.85), 5군(3.05) 순으로 증가하였다. 3. All-in-one adhesive를 사용한 3, 4, 5군중에서 3군은 4, 5군에 비해 통계적으로 유의성 있게 낮은 평균미세누출 도를 보여주었지만(p<0.05) 1군과 2군에 비해 유의성 있게 높은 평균값을 보여주었다(p<0.05). 4. 4군과 5군 사이의 평균미세누출도는 통계적으로 유의성 있는 차이를 보이지 않았다(p>0.05). 5. 주사전자현미경관찰결과 all-in-one adhesive를 사용한 3, 4, 5군은 1, 2군에 비해 레진돌기가 짧고 불규칙하게 관찰되었다.

  • PDF