• Title/Summary/Keyword: One Scan Method

Search Result 297, Processing Time 0.028 seconds

Development of Tomographic Scan Method for Industrial Plants (산업공정반응기의 감마선 전산 단층촬영기술 개발)

  • Kim, Jong-Bum;Jung, Sung-Hee;Moon, Jin-Ho;Kwon, Taek-Yong;Cho, Gyu-Seong
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.30 no.1
    • /
    • pp.20-30
    • /
    • 2010
  • In this paper, a new tomographic scan method with fixed installed detectors and rotating source from gamma projector was presented to diagnose the industrial plants which were impossible to be examined by conventional tomographic systems. Weight matrix calculation method which was suitable for volumetric detector and statistical iterative reconstruction method were applied for reconstructing the simulation and experimental data. Monte Carlo simulations had been performed for two kinds of phantoms. Lab scale experiment with a same condition as one of phantoms, had been carried out. Simulation results showed that reconstruction from photopeak counting measurement gave the better results than from the gross counting measurement although photopeak counting measurement had large statistical errors. Experimental data showed the similar result as Monte Carlo simulation. Those results appeared to be promising for industrial tomographic applications, especially for petrochemical industries.

Is $^{201}Tl-^{99m}Tc$-Subtraction Scan an Accurate Diagnostic Method to Detect Parathyroid Mass? ($^{201}Tl/^{99m}Tc$ 감영스캔으로 부갑상선종괴를 얼마나 찾을 수 있는가?)

  • Yang, Hyung-In;Kim, Deog-Yoon;Kim, Kwang-Won;Choi, Young-Kil
    • The Korean Journal of Nuclear Medicine
    • /
    • v.28 no.1
    • /
    • pp.31-36
    • /
    • 1994
  • We studied 65 patients with hypercalcemia who had heed performed $^{201}Tl/^{99m}Tc$ subtraction scan, 21 of them were confirmed as parathyroid tumor (19 adenoma, 2 carcinoma). The diagnostic sensitivity of $^{201}Tl/^{99m}Tc$ subfraction scan for detecting parathyroid mass was 90.5%, specificity was 97.6%, ultrasonography was 80.6%, 58.8%, respectively. The causes of two false negative cases were relatively small size ($1.5{\times}1{\times}0.8cm$) compared to remainig cases and poor thallium uptake due to cystic necrosis of parathyroid adenoma. The one false positive case was non-functioning thyroid nodule. $^{201}Tl/^{99m}Tc$ subtraction scan was simple, effective diagnostic tool and superior to ultrasonography for evaluating the parathyroid mass with high sensitivity and specificity.

  • PDF

TFSCAN 검색 프로그램 TFSCAN의 개발

  • Lee, Byung-Uk;Park, Kie-Jung;Kim, Ki-Bong;Park, Wan;Park, Yong-Ha
    • Microbiology and Biotechnology Letters
    • /
    • v.24 no.3
    • /
    • pp.371-375
    • /
    • 1996
  • TFD is a transcription factor database which consists of short functional DNA sequences called as signals and their references. SIGNAL SCAN, developed by Dan S. Prestridge, is used to determine what signals of TFD may exist in a DNA sequence. This program searches TFD database by using a simple algorithm for character string comparison. We developed TFSCAN that aims at searching for signals in an input DNA sequence more efficently than SIGNAL SCAN. Our algorithms consist of two parts, one constructs an automata by scanning sequences of rFD, the other searches for signals through this automata. Searching for signal-related references is radically improved in time by using an indexing method. Usage of TFSCAN is very simple and its output is obvious. We developed and installed a TFSCAN input form and a CGI program in GINet Web server, to use TFSCAN. The algorithm applying automata showed drastical results in improvement of computing time. This approach may apply to recognizing several biological patterns. We have been developing our algorithm to optimize the automata and to search more sensitively for signals.

  • PDF

A study on procedure for classifying male muscular lower body somatotype from general anthropometric database

  • Lee, Minji;Chun, Jongsuk
    • The Research Journal of the Costume Culture
    • /
    • v.21 no.4
    • /
    • pp.585-595
    • /
    • 2013
  • The most researches developing pattern of compression style sportswear were targeted at the live model that has muscular body build. The purpose of this study was developing a method for classifying men's lower body types in terms of muscular body build. The 3D human body scan data and body measurements of 30s of Size Korea were analyzed. The subjects (n=203) were men between the ages of 30 and 39 years. Men's muscular body build was classified with two key dimensions, thigh girth and calf girth. The subjects were divided into four groups. From each group, average subjects (n=42) whose height and weight were close to the mean value ($mean{\pm}1/2$ S.D.) were selected. 42 subjects were divided up as four groups. Group I (n=7) was thigh and calf developed body type. Group II (n=9) was thigh developed body type. Group III (n=11) was calf developed body type. Group IV (n=15) was thigh and calf undeveloped body type. Four groups had distinct different at widths (n=4), depths (n=4), and girths (n=9) dimensions. The results showed that the muscular men in their 30s could be defined by thigh and calf girths. The thigh developed muscular men had thigh girth over 60cm and the calf developed muscular men had calf girth over 38cm. From each group one representative was selected by 3D body scan figure.

A study on the compensation of misfiring by the method of ramp address voltage in AC PDP (AC PDP의 경사형 Address 전압 인가 방식에 의한 오방전 보상에 관한 연구)

  • Kim, J.Y.;Lee, S.J.;Kwon, B.D.;Kim, D.H.;Lee, H.J.;Park, J.H.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.05a
    • /
    • pp.149-152
    • /
    • 2002
  • If the ambient temperature rises for AC PDP, some of the discharge cells are turned off because of the misfiring during address period. Particularly, the misfiring of the 'last scan line is more serious than that of the first. In order to compensate the misfiring in such that case, different addressing voltage is applied at each cell such as progressively increasing pulse voltage instead of constant one. As a result, the addressing time and discharge charge of the last scan line have become similar to those of the first scan line and the phenomenon of misfiring has disappeared.

  • PDF

A Study on the Improvement for Medical Service Using Video Promotion Materials for PET/CT Scans (PET/CT 검사에서 동영상 홍보물을 통한 의료서비스 향상에 관한 연구)

  • Kim, Woo Hyun;Kim, Jung Seon;Ko, Hyun Soo;Sung, Ji Hye;Lee, Jeoung Eun
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.1
    • /
    • pp.30-35
    • /
    • 2013
  • Purpose: One of the current services, providing information to the patients and their guardians by using promotion materials induces positive responses and contributes to the improvement of the hospital reliability. Therefore, the objective of this study is to evaluate the effectiveness of audio visual materials, one of the means of promotion, as a way to give accurate medical information to resolve patient's curiosity about purpose and procedure of their examination and deplete complains about waiting which attributes negative effect to service quality assessment. Materials and Methods: 60 patients(mean age $53.97{\pm}12.24$, male : female = 26 : 34) who had $^{18}F-FDG PET/CT$ scan from July 2012 to August 2012 in Seoul Asan Medical Center were referred to the study. All of the patients having PET/CT scan were asked to watch an informative video material before the injection of radiopharmaceutical ($^{18}F-FDG$) and to fill in a questionnaire. Results: As a result of analyzing the contents of questionnaire, 52% of 60 patients had PET/CT scan for the first time and 72.4% of the patients read the PET/CT guidebook offered from their outpatient department or inpatient wards before their scan. After we searched the level of previous knowledge of the purpose and method of PET/CT scan, the patients answered 25.1% "know well", 34% "not sure", 40.9% "don't know" respectively. And 84.7% of the patients answered that watching the PET/CT guide video before the injection helps understanding what exam they were having and 15.3% of the patients did not. For the question asking ever the patients have experienced using our homepage or smart phone QR code to see the guide video before they visit out PET center, only 3.3% of them answered "yes". Lastly, the patients answered 60.1% "yes", 31.4% "so so" and 8.5% "no" respectively for the question asking whether watching the video makes the patients to fill the waiting time short. Conclusion: It is found that understanding of objective and method of the PET/CT scan and level of satisfaction was improved after the patients watched the guide video whether they had PET/CT scan before and read the PET/CT guidebook or not. Also, watching the video was effective for the reduction of perceptible waiting time. But while displaying the PET/CT guide video is useful for providing information about the scan and shortening the waiting time as one of the medical service, utilization of service was actually very poor because of the passive promotion and indifference of the patients about their examination. Therefore, from now on, it is necessary to construct the healthcare system which can be offered to more patients through the active promotion.

  • PDF

A study on design of instantaneous field of view of rosette scanning infrared seeker (로젯 주사 적외선 탐색기의 순시 시계 설계에 관한 연구)

  • 장성갑;홍현기;한성현;최종수
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.35S no.7
    • /
    • pp.86-94
    • /
    • 1998
  • The rosette-scan seeker is a device mounted on the infrared guided missile. It offers the positions and iamges of target to missiles servo system by scanning a space about target in rosette pattern with a single detector. An instantaneous field of view (IFOV), which is a diameter of a detector moving along the path of the rosette pattern, has the property that its smaller size provide the less interference of background signals and detector noise. If its size is too small to voer the total field of view (TFOV), however, it produces the invisible regions in the TFOV. In this case, the invisible regions cause the performance of the seeker to deteriorate. For full scan-coverage, it is necessary to design the small IFOV without the invisible regions in the TFOV, as possible. In this paper, we propose the new method of designing the smaller IFOV than the conventional method and verify full coverage of the scanned region. By comparing the nose equivalent flux density (NEFD) of the proposed method with the that of the conventional one, we confirm that the former is better than the latter in terms of performance.

  • PDF

A 3D Foot Scanner Using Mirrors and Single Camera (거울 및 단일 카메라를 이용한 3차원 발 스캐너)

  • Chung, Seong-Youb;Park, Sang-Kun
    • Korean Journal of Computational Design and Engineering
    • /
    • v.16 no.1
    • /
    • pp.11-20
    • /
    • 2011
  • A structured beam laser is often used to scan object and make 3D model. Multiple cameras are inevitable to see occluded areas, which is the main reason of the high price of the scanner. In this paper, a low cost 3D foot scanner is developed using one camera and two mirrors. The camera and two mirrors are located below and above the foot, respectively. Occluded area, which is the top of the foot, is reflected by the mirrors. Then the camera measures 3D point data of the bottom and top of the foot at the same time. Then, the whole foot model is reconstructed after symmetrical transformation of the data reflected by mirrors. The reliability of the scan data depends on the accuracy of the parameters between the camera and the laser. A calibration method is also proposed and verified by experiments. The results of the experiments show that the worst errors of the system are 2 mm along x, y, and z directions.

Development of On-line Wrinkle Measurement System Using Machine Vision (머신 비젼을 이용한 실시간 링클 측정 시스템 개발)

  • Shin, Dong-Keun;To, Hoang-Minh;Ko, Sung-Lim
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.32 no.3
    • /
    • pp.274-279
    • /
    • 2008
  • Roll to roll (R2R) manufacturing process, also known as 'web processing', has been tried for producing electronic devices on a flexible plastic or metal foil. To increase the performance and productivity the R2R process, effective control and on-line supervision for web quality becomes very important. Wrinkle is one of the defects, which is incurred due to compressive stresses. A system for on-line measurement of wrinkle is developed using area scan camera and machine vision laser. The 2D image, obtained by area scan camera, is produced by Gaussian regression method to characterize the wrinkle on a transparent web. The experiment proves that 0.3mm wrinkle height can be measured successfully with 74fps.

3D Reconstruction of Urban Building using Laser range finder and CCD camera

  • Kim B. S.;Park Y. M.;Lee K. H.
    • Proceedings of the KSRS Conference
    • /
    • 2004.10a
    • /
    • pp.128-131
    • /
    • 2004
  • In this paper, we describe reconstructed 3D-urban modeling techniques for laser scanner and CCD camera system, which are loading on the vehicle. We use two laser scanners, the one is horizon scanner and the other is vertical scanner. Horizon scanner acquires the horizon data of building for localization. Vertical scan data are main information for constructing a building. We compared extraction of edge aerial image with laser scan data. This method is able to correct the cumulative error of self-localization. Then we remove obstacles of 3D-reconstructed building. Real-texture information that is acquired with CCD camera is mapped by 3D-depth information. 3D building of urban is reconstructed to 3D-virtual world. These techniques apply to city plan. 3D-environment game. movie background. unmanned-patrol etc.

  • PDF